934 resultados para capacitive cooling
Resumo:
The demands in production and associate costs at power generation through non renewable resources are increasing at an alarming rate. Solar energy is one of the renewable resource that has the potential to minimize this increase. Utilization of solar energy have been concentrated mainly on heating application. The use of solar energy in cooling systems in building would benefit greatly achieving the goal of non-renewable energy minimization. The approaches of solar energy heating system research done by initiation such as University of Wisconsin at Madison and building heat flow model research conducted by Oklahoma State University can be used to develop and optimize solar cooling building system. The research uses two approaches to develop a Graphical User Interface (GUI) software for an integrated solar absorption cooling building model, which is capable of simulating and optimizing the absorption cooling system using solar energy as the main energy source to drive the cycle. The software was then put through a number of litmus test to verify its integrity. The litmus test was conducted on various building cooling system data sets of similar applications around the world. The output obtained from the software developed were identical with established experimental results from the data sets used. Software developed by other research are catered for advanced users. The software developed by this research is not only reliable in its code integrity but also through its integrated approach which is catered for new entry users. Hence, this dissertation aims to correctly model a complete building with the absorption cooling system in appropriate climate as a cost effective alternative to conventional vapor compression system.
Resumo:
The effects of Si and cooling rate are investigated for their effect on the mechanical properties and microstructure. Three alloys were chosen with varying C and Si contents and an attempt to keep the remainder of the elements present constant. Within each heat, three test blocks were poured. Two blocks had chills – one with a fluid flowing through it to cool it (active chill) and one without the fluid (passive) – and the third block did not have a chill. Cooling curves were gathered and analyzed. The mechanical properties of the castings were correlated to the microstructure, cooling rate and Si content of each block. It was found that an increase in Si content increased the yield stress, tensile strength and hardness but decreased the impact toughness, elongation and Young’s modulus. The fast cooling rates produced by the chills caused a high nodule count in the castings along with a fine ferrite grain size and a high degree of nodularity. The fine microstructures, in turn, increased the strength and ductile to brittle transition temperature (DBTT) of the castings. The fast cooling rate was not adequate to overcome the dramatic increase in DBTT that is caused by the addition of Si.
Resumo:
Inductive-capacitive (LC) resonant circuit sensors are low-cost, wireless, durable, simple to fabricate and battery-less. Consequently, they are well suited to sensing applications in harsh environments or in situations where large numbers of sensors are needed. They are also advantageous in applications where access to the sensor is limited or impossible or when sensors are needed on a disposable basis. Due to their many advantages, LC sensors have been used for sensing a variety of parameters including humidity, temperature, chemical concentrations, pH, stress/pressure, strain, food quality and even biological growth. However, current versions of the LC sensor technology are limited to sensing only one parameter. The purpose of this work is to develop new types of LC sensor systems that are simpler to fabricate (hence lower cost) or capable of monitoring multiple parameters simultaneously. One design presented in this work, referred to as the multi-element LC sensor, is able to measure multiple parameters simultaneously using a second capacitive element. Compared to conventional LC sensors, this design can sense multiple parameters with a higher detection range than two independent sensors while maintaining the same overall sensor footprint. In addition, the two-element sensor does not suffer from interference issues normally encountered while implementing two LC sensors in close proximity. Another design, the single-spiral inductive-capacitive sensor, utilizes the parasitic capacitance of a coil or spring structure to form a single layer LC resonant circuit. Unlike conventional LC sensors, this design is truly planar, thus simplifying its fabrication process and reducing sensor cost. Due to the simplicity of this sensor layout it will be easier and more cost-effective for embedding in common building or packaging materials during manufacturing processes, thereby adding functionality to current products (such as drywall sheets) while having a minor impact on overall unit cost. These modifications to the LC sensor design significantly improve the functionality and commercial feasibility of this technology, especially for applications where a large array of sensors or multiple sensing parameters are required.
Resumo:
OBJECTIVES: The purpose of this study is to evaluate the effects of crossclamping the ascending aorta in acute type A aortic dissection during the cooling phase for deep hypothermic arrest on early clinical outcome. METHODS: The records of 275 consecutive patients who underwent surgery for acute type A aortic dissection were reviewed. Ten patients have been excluded. Overall, 265 patients who underwent surgery under deep hypothermia and circulatory arrest in the "open technique" were divided retrospectively into two groups: those who underwent surgery with crossclamping of the ascending aorta during the cooling phase at the begin of the procedure (group 1, n = 191; 72.1 %) and those in whom the aorta was not clamped (group 2, n = 74; 27.9 %). RESULTS: Preoperative characteristics were similar in both groups. In group 1, femoral artery cannulation, composite graft repair, and aortic arch replacement were significantly more frequent. In-hospital mortality was 15.2 % in group 1 and 17.6 % in group 2 (P = not significant). Neurologic deficits were observed in 9.4% in group 1 and in 10.8% in group 2 (= not significant). There were no significant differences in clinical outcome between the two groups of patients. CONCLUSIONS: This study demonstrates that both options, aortic crossclamping or noclamping, may be used during the induction of deep hypothermia to repair acute type A aortic dissections with similar early clinical outcome. For the selection of the most appropriate technique, we recommend case by case evaluation, weighing the potential risks and benefits of aortic crossclamping.
Resumo:
Rapid changes in atmospheric methane (CH4), temperature and precipitation are documented by Greenland ice core data both for glacial times (the so called Dansgaard-Oeschger (D-O) events) as well as for a cooling event in the early Holocene (the 8.2 kyr event). The onsets of D-O warm events are paralleled by abrupt increases in CH4 by up to 250 ppb in a few decades. Vice versa, the 8.2 kyr event is accompanied by an intermittent decrease in CH4 of about 80 ppb over 150 yr. The abrupt CH4 changes are thought to mainly originate from source emission variations in tropical and boreal wet ecosystems, but complex process oriented bottom-up model estimates of the changes in these ecosystems during rapid climate changes are still missing. Here we present simulations of CH4 emissions from northern peatlands with the LPJ-Bern dynamic global vegetation model. The model represents CH4 production and oxidation in soils and transport by ebullition, through plant aerenchyma, and by diffusion. Parameters are tuned to represent site emission data as well as inversion-based estimates of northern wetland emissions. The model is forced with climate input data from freshwater hosing experiments using the NCAR CSM1.4 climate model to simulate an abrupt cooling event. A concentration reduction of ~10 ppb is simulated per degree K change of mean northern hemispheric surface temperature in peatlands. Peatland emissions are equally sensitive to both changes in temperature and in precipitation. If simulated changes are taken as an analogy to the 8.2 kyr event, boreal peatland emissions alone could only explain 23 of the 80 ppb decline in atmospheric methane concentration. This points to a significant contribution to source changes from low latitude and tropical wetlands to this event.
Resumo:
Ar-40/Ar-39 total gas and plateau dates from muscovite and biotite in the southern Black Hills, South Dakota, provide evidence for a period of Middle Proterozoic slow cooling. Early Proterozoic (1600-1650 Ma) mica dates were obtained from metasedimentary rocks located in a synformal structure between the Harney Peak and Bear Mountain domes and also south of Bear Mountain. Metamorphic rocks from the dome areas and undeformed samples of the similar to 1710 Ma Harney Peak Granite (HPG) yield Middle Proterozoic mica dates (similar to 1270-1500 Ma). Two samples collected between the synform and Bear Mountain dome yield intermediate total gas mica dates of similar to 1550 Ma. We suggest two end-member interpretations to explain the map pattern of cooling ages: (1) subhorizontal slow cooling of an area which exhibits variation in mica Ar retention intervals or (2) mild folding of a Middle Proterozoic (similar to 1500 Ma) similar to 300 degrees C isotherm. According to the second interpretation, the preservation of older dates between the domes may reflect reactivation of a preexisting synformal structure (and downwarping of relatively cold rocks) during a period of approximately east-west contraction and slow uplift during the Middle Proterozoic. The mica data, together with hornblende data from the Black Hills published elsewhere, indicate that the ambient country-rock temperature at the 3-4 kbar depth of emplacement of the HPG was between 350 degrees C and 500 degrees C, suggesting that the average upper crustal geothermal gradient was 25 degrees-40 degrees C/km prior to intrusion. The thermochronologic data suggest HPG emplacement was followed by a similar to 200 m.y. period of stability and tectonic quiescence with little uplift. We propose that crust thickened during the Early Proterozoic was uplifted and erosionally(?) thinned prior to similar to 1710 Ma and that the HPG magma was emplaced into isostatically stable crust of relatively normal thickness. We speculate that uplift and crustal thinning prior to HPG intrusion was the result of differential thinning of the subcrustal lithosphere beneath the Black Hills. If so, this process would have also caused an increase in mantle heat flux across the Moho and triggered vapor-absent melting of biotite to produce the HPG magma. This scenario for posttectonic granite generation is supported, in part, by the fact that in the whole of the Black Hills, the HPG is spatially associated with the deepest exposed Early Proterozoic country rock.
Resumo:
Two Proterozoic terranes with different metamorphic histories are distinguished from geological mapping in southwestern Wedel Jarlsberg Land: a northern greenschist facies terrane and a southern amphibolite facies terrane which has been overprinted by greenschist facies metamorphism. To better characterize the tectonothermal history of these terranes we have obtained new Ar-40/Ar-39 mineral dates from this area. A muscovite separate from the northern terrane yielded a Caledonian plateau age of 432 +/- 7 Ma. The southern terrane yielded significantly older Ar-40/Ar-39 ages with three muscovite plateau dates of 584 +/- 14 Ma, 575 +/- 15 Ma, and 459 +/- 9 Ma, a 484 +/- 5 Ma biotite plateau date, and a 616 +/- 17 Ma hornblende plateau date. The oldest thermochronological dates are over 300 Ma younger than the age of amphibolite facies metamorphism and therefore probably do not represent uplift-related cooling. Instead, the Vendian dates correlate well with a regionally widespread magmatic and metamorphic/thermal resetting event recognized within Caledonian complexes of northwestern Spitsbergen and Nordaustlandet. The apparent Ordovician dates are interpreted to represent partial resetting, suggesting that late Caledonian greenschist facies overprinting of the southern terrane was of variable intensity.
Resumo:
Liquid–vapour homogenisation temperatures of fluid inclusions in stalagmites are used for quantitative temperature reconstructions in paleoclimate research. Specifically for this application, we have developed a novel heating/cooling stage that can be operated with large stalagmite sections of up to 17 × 35 mm2 to simplify and improve the chronological reconstruction of paleotemperature time-series. The stage is designed for use of an oil immersion objective and a high-NA condenser front lens to obtain high-resolution images for bubble radius measurements. The temperature accuracy of the stage is better than ± 0.1 °C with a precision (reproducibility) of ± 0.02 °C.
Resumo:
The abrupt Northern Hemispheric warming at the end of the twentieth century has been attributed to an enhanced greenhouse effect. Yet Greenland and surrounding subpolar North Atlantic remained anomalously cold in 1970s to early 1990s. Here we reconstructed robust Greenland temperature records (North Greenland Ice Core Project and Greenland Ice Sheet Project 2) over the past 2100 years using argon and nitrogen isotopes in air trapped within ice cores and show that this cold anomaly was part of a recursive pattern of antiphase Greenland temperature responses to solar variability with a possible multidecadal lag. We hypothesize that high solar activity during the modern solar maximum (approximately 1950s–1980s) resulted in a cooling over Greenland and surrounding subpolar North Atlantic through the slowdown of Atlantic Meridional Overturning Circulation with atmospheric feedback processes.
Resumo:
BACKGROUND Therapeutic hypothermia following hypoxic ischaemic encephalopathy in term infants was introduced into Switzerland in 2005. Initial documentation of perinatal and resuscitation details was poor and neuromonitoring insufficient. In 2011, a National Asphyxia and Cooling Register was introduced. AIMS To compare management of cooled infants before and after introduction of the register concerning documentation, neuromonitoring, cooling methods and evaluation of temperature variability between cooling methods. STUDY DESIGN Data of cooled infants before the register was in place (first time period: 2005-2010) and afterwards (second time period: 2011-2012) was collected with a case report form. RESULTS 150 infants were cooled during the first time period and 97 during the second time period. Most infants were cooled passively or passively with gel packs during both time periods (82% in 2005-2010 vs 70% in 2011-2012), however more infants were cooled actively during the second time period (18% versus 30%). Overall there was a significant reduction in temperature variability (p < 0.001) comparing the two time periods. A significantly higher proportion of temperature measurements within target temperature range (72% versus 77%, p < 0.001), fewer temperature measurements above (24% versus 7%, p < 0.001) and more temperatures below target range (4% versus 16%, p < 0.001) were recorded during the second time period. Neuromonitoring improved after introduction of the cooling register. CONCLUSION Management of infants with HIE improved since introducing the register. Temperature variability was reduced, more temperature measurements in the target range and fewer temperature measurements above target range were observed. Neuromonitoring has improved, however imaging should be performed more often.
Resumo:
Evaporative cooling systems continue to be associated with outbreaks of Legionnaires’ disease despite widely available maintenance guidelines intended to reduce these outbreaks. Yet, the guidelines vary widely regarding the recommendations that are made to maintain evaporative cooling systems and it is unclear whether guidelines were in place or, if they were, whether they were being followed when the outbreaks of Legionnaires’ disease occurred. Thus, this study was designed to conduct two systematic reviews of (1) evaporative cooling system maintenance guidelines; and (2) published Legionnaires’ disease outbreaks. For each maintenance guideline identified in the systematic review, recommended maintenance practices were abstracted and similarities and/or differences in the reported recommendations were assessed. Following the systematic review of outbreak investigations that meet the inclusion criteria established for the study, information about the state of the evaporative cooling system during the outbreak investigation was abstracted to summarize, when reported, which maintenance practices were implemented. As expected, the recommended maintenance procedures varied greatly across the guidelines and were not always specific. Overall, the outbreak investigations tended to report similar maintenance issues that were unclear in the maintenance guidelines. Generally, these maintenance issues were biocide use, microbiological testing, frequency of general inspections, and protocols and frequency of total system cleanings. The role in which non-standardized and generalized maintenance guidelines plays in the continued association between Legionnaires’ disease and evaporative cooling systems is still not fully understood. However, this study suggests that more specific and standardized maintenance guidelines, that have been scientifically established to be effective in controlling Legionella bacteria, are needed and then these guidelines must be properly implemented in order to help reduce further Legionnaires’ disease outbreaks associated with evaporative cooling systems.^
Resumo:
About 34 million years ago, Earth's climate shifted from a relatively ice-free world to one with glacial conditions on Antarctica characterized by substantial ice sheets. How Earth's temperature changed during this climate transition remains poorly understood, and evidence for Northern Hemisphere polar ice is controversial. Here, we report proxy records of sea surface temperatures from multiple ocean localities and show that the high-latitude temperature decrease was substantial and heterogeneous. High-latitude (45 degrees to 70 degrees in both hemispheres) temperatures before the climate transition were ~20°C and cooled an average of ~5°C. Our results, combined with ocean and ice-sheet model simulations and benthic oxygen isotope records, indicate that Northern Hemisphere glaciation was not required to accommodate the magnitude of continental ice growth during this time.