918 resultados para angular speed
Resumo:
Objective: To compare the effects of the treadmill training with partial body-weight support (TPBWS) and Proprioceptive Neuromuscular Facilitation (PNF) method on gait of subjects with chronic stroke. Design: Quasi-experimental study. Setting: Laboratorial research. Participants: Twenty-three subjects (13 men and 10 women), with a mean age of 56,7 ± 8,0 years and a mean time since the onset of the stroke of 27,7 ± 20,3 months, and able to walk with personal assistance or assistive devices. Interventions: Two experimental groups underwent gait training based on PNF method (PNF group, n=11) or using the TPBWS - Gait Trainer System 2, Biodex, USA (TPBWS group, n=12), for three weekly sessions, during four weeks. Measures: Evaluation of motor function - using the Stroke Rehabilitation Assessment of Movement (STREAM) and the motor subscale of the Functional Independence Measure (motor FIM) -, and kinematic gait analyze with the Qualisys System (Qualisys Medical AB, Gothenburg, Sweden) were carried out before and after the interventions. Results: Increases in the STREAM scores (F=49.189, P<0.001) and in motor FIM scores (F=7.093, P=0.016), as well as improvement in symmetry ratio (F=7.729, P=0.012) were observed for both groups. Speed, stride length and double-support time showed no change after training. Differences between groups were observed only for the maximum ankle dorsiflexion over the swing phase (F=6.046, P=0.024), which showed an increase for the PNF group. Other angular parameters remain unchanged. Conclusion: Improvement in motor function and in gait symmetry was observed for both groups, suggesting similarity of interventions. The cost-effectiveness of each treatment should be considered for your choice
Resumo:
In this paper, an experimental set-up which differs from the traditional ones is established in order to determine the moment of inertia of a right circular cone. Its angular variation and inertia ellipsoid are determined by means of an experimental study. In addition, a system that allows for the evaluation of the angular acceleration and torque through electric current or frequency measurement is utilized.
Resumo:
Background: The gait automaticity loss difficults realization of concurrent activities - Dual Task (DT). In these situations, individuals with Parkinson`s disease (PD) show a significant reduction in gait velocity and stride length, as strides variability and asymmetry increased, factors predisposing to falls. However, recent studies have shown that training involving DT may cause subsequent improvements in gait variables with DT in individuals with PD. The treadmill use was adopted by this study, by promoting greater regularity in step and enhance training. Objective:To investigate immediate effects of gait training associated with cognitive tasks on gait in individuals with PD. Methods: Twenty-two volunteers were randomly divided into two groups: control group (n = 11), who performed gait training on a treadmill for 20 minutes, and the experimental group (n = 11), who performed treadmill gait training for 20 minutes associated with cognitive tasks of verbal fluency, memory, and spatial planning. Participants were evaluated in phase on of antiparkinsonian medication as the demographic, clinical and anthropometric (identification form), cognitive status (Montreal Cognitive Assessment - MoCA), executive function (Frontal Assessment Battery), level of physical disability (Hoehn and Yahr Modified), motor and functional status (Unified Rating Scale for Parkinson`s Disease - UPDRS), and kinematics (Qualisys Motion Capture System). Results: There were not differences between groups, but both showed improvement after the intervention. The control group had an increase in velocity (p = 0.008), stride length (p = 0.04), step length (p = 0.02) and decreased double support time(p = 0.03). The experimental group showed an increase in speed (p = 0.002), stride length (p = 0.008), step length (p = 0.02) and cadence (p = 0.01), as well as a decrease in the width stride (p = 0.001) and total support time (p = 0.02). As the angular variables, the experimental group had a significant increase in the initial contact angle of ankle (p = 0.01). Conclusion: The gait training combined with cognitive activities didn`t provide significant improvements in gait variables with DT, but this study was the first to demonstrate that gait training on treadmill as simple task minimized the negative interference of DT in PD
Resumo:
The industry's interest in having a greater control of the deformations caused by welding is due to the geometric and dimensional tolerances been more and more precise in the project specifications, motivating the manufacturing engineering to develop stable processes and to ensure routine production. Aiming at it, the main goal of this present work is to analyze how much routine situations used in automatic aluminum welding can influence on the angular deformations of this material. Using the alloy AA 5052 H34, and the automatic welding in pulsed GMAW process, three types of weaving were applied throughout the length of the weld, in butt joints assembled without groove and with 60 degrees single-V-groove, arranged transversely as well as longitudinally to the rolling direction of the plate. The measurement of the deformations was made by a three-dimensional equipment, before and after the welding, in three distinct regions in the specimens. The profile of the weld bead was the main factor for the different types of deformations found, as revealed by macrographical analysis. The 60 degrees single-V-groove had higher amplitudes of deformations as the joint without groove. The torch oscillation wasn't a variable of statistically significant influence on this amplitudes.
Resumo:
Over the years, grinding has been considered one of the most important manufacturing processes. Grinding is a high precision process, and the loss of a single workpiece in this stage of the production is unacceptable, fir the value added to the material is very high due to many processes it has already undergone prior to grinding. This study aims to contribute toward the development of an experimental methodology whereby the pressure and speed of the air layer produced by the high rotation of the grinding wheel is evaluated with and without baffles, i.e., in an optimized grinding operation and in a traditional one. Tests were also carried out with steel samples to check the difference in grinding wheel wear with and without the use of baffles.
Resumo:
The world tendency is the increase of the productivity and the production of pieces more and more sophisticated, with high degree of geometric and dimensional tolerances, with good surface finish and low cost. Rectification is responsible for the final finish in the machining process of a material. However, damages generated in this production phase affect all the resources used in the previous processes. Great part of the problems happennig in the rectification process is due to the enormous temperature generated in this activity because of the machining conditions. The dive speed, which is directly related to the productivity, is considered responsible for the damages that occur during rectification, limiting its values to those that do not cause such damages. In this work, through the variation of the dive speed in the process of cylindrical grinding of type ABNT D6 steel, rationalizing the application of two cutting fluids and using a CBN (cubic boron nitrate) abrasive wheel with vitrified blond, the influence of the dive speed on the surface damages of hardened steels was evaluated. The results allowed to say that the dive speed, associated to an efficient cooling and lubrication, didn't provoke thermal damages (including heated zones, cracks and tension stresses) to the material. Residual stresses and the roughness of rectified materials presented a correlation with the machining conditions. The work concluded that it is possible to increase the productivity without provoking damages in the rectified components.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Power performance evaluation of an electric home fan with triac-based automatic speed control system
Resumo:
In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.
Resumo:
Based on analyses of high-speed video recordings of cloud-to-ground lightning in Brazil and the USA, the characteristics of positive cloud-to-ground (+CG) leaders are presented. The high frame rates permitted the average, 2-dimensional speeds of development along the paths of the channels to be resolved with good accuracy. The values range from 0.3 to 6.0 x 10(5) ms(-1) with a mean of 2.7 x 10(5) ms(-1). Contrary to what is usually assumed, downward +CG leader speeds are similar to downward -CG leader speeds. Our observations also show that the speeds tend to increase by a factor of 1.1 to 6.5 as they approach the ground. The presence of short duration, recoil leaders (RLs) during the development of positive leaders reveal a highly branched structure that is not usually recorded when using conventional photographic and video cameras. The existence of the RLs may help to explain observations of UHF-VHF radiation during the development of +CG flashes.
Resumo:
A novel single-phase voltage source rectifier capable to achieve High-Power-Factor (HPF) for variable speed refrigeration system application, is proposed in this paper. The proposed system is composed by a single-phase high-power-factor boost rectifier, with two cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the EEC61000-3-2 standards. The digital controller for the output stage has been developed using a conventional voltage-frequency control (scalar V/f control), and a simplified stator oriented Vector control, in order to verify the feasibility and performance of the proposed digital controls for continuous temperature control applied at a refrigerator prototype.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to evaluate the effect of unilateral angular misfit of 100 Km on stress distribution of implant-supported single crowns with ceramic veneering and gold framework by three-dimensional finite element analysis. Two three-dimensional models representing a maxillary section of premolar region were constructed: group 1 (control)-crown completely adapted to the implant and group 2-crown with unilateral angular misfit of 100 Km. A vertical force of 100 N was applied on 2 centric points of the crown. The von Mises stress was used as an analysis criterion. The stress values and distribution in the main maps (204.4 MPa for group 1 and 205.0 MPa for group 2) and in the other structures (aesthetic veneering, framework, retention screw, implant, and bone tissue) were similar for both groups. The highest stress values were observed between the first and second threads of the retention screw. Considering the bone tissue, the highest stress values were exhibited in the peri-implant cortical bone. The unilateral angular misfit of 100 Km did not influence the stress distribution on the implant-supported prosthesis under static loading.
Resumo:
Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796
Resumo:
Objective: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.Methods: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc).Results: Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric.Conclusions: All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.
Resumo:
A distalização dos molares superiores constitui um desafio na correção da má oclusão de Classe II em tratamentos sem extrações dentárias e sem avanço mandibular. Há uma procura por dispositivos que substituam a tração extrabucal (AEB) e que não exijam demasiada colaboração do paciente, o que estimula os ortodontistas a testarem métodos alternativos aos relatados na literatura. Dentre estes, destacam-se os aparelhos Pêndulo e Pendex de Hilgers. OBJETIVO: a realização desta pesquisa teve o intuito de avaliar, mediante a cefalometria, os efeitos do aparelho Pendex aplicado no final da dentadura mista e na dentadura permanente. METODOLOGIA: a amostra constou de 14 pacientes com má oclusão de Classe II bilateral, com média de idade de 11 anos e 3 meses. Foram tomadas duas telerradiografias em norma lateral, uma correspondente ao início do tratamento e outra aproximadamente 5 meses após sua finalização, quando a relação dos molares encontrava-se sobrecorrigida. RESULTADOS: após a determinação e mensuração das grandezas cefalométricas lineares e angulares e análise estatística (Teste t de Student), pode-se concluir que os efeitos do aparelho Pendex foram predominantemente ortodônticos: distalização da coroa dos primeiros molares permanentes numa velocidade média de 0,8 mm/mês e vestibularização dos incisivos superiores com aumento do trespasse horizontal. CONCLUSÃO: assim sendo, quando há indicação para distalização dos molares, cumpre-se fazer uma análise dos fatores envolvidos, a fim de eleger, com prudência, a solução terapêutica mais adequada às exigências individuais e profissionais.