993 resultados para Violin with chamber orchestra


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heavy-ion collisions are a powerful tool to study hot and dense QCD matter, the so-called Quark Gluon Plasma (QGP). Since heavy quarks (charm and beauty) are dominantly produced in the early stages of the collision, they experience the complete evolution of the system. Measurements of electrons from heavy-flavour hadron decay is one possible way to study the interaction of these particles with the QGP. With ALICE at LHC, electrons can be identified with high efficiency and purity. A strong suppression of heavy-flavour decay electrons has been observed at high $p_{m T}$ in Pb-Pb collisions at 2.76 TeV. Measurements in p-Pb collisions are crucial to understand cold nuclear matter effects on heavy-flavour production in heavy-ion collisions. The spectrum of electrons from the decays of hadrons containing charm and beauty was measured in p-Pb collisions at $\\sqrt = 5.02$ TeV. The heavy flavour decay electrons were measured by using the Time Projection Chamber (TPC) and the Electromagnetic Calorimeter (EMCal) detectors from ALICE in the transverse-momentum range $2 < p_ < 20$ GeV/c. The measurements were done in two different data set: minimum bias collisions and data using the EMCal trigger. The non-heavy flavour electron background was removed using an invariant mass method. The results are compatible with one ($R_ \\approx$ 1) and the cold nuclear matter effects in p-Pb collisions are small for the electrons from heavy-flavour hadron decays.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on the latter is very low, and some concerns still remain about its long-term safety. The present article reviews the published literature on the outcomes after PRL implantation in order to provide a general overview and evaluate its real potential as a surgical refractive option.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One folio-sized leaf containing a handwritten table with information about student boarders in Cambridge residences listing the names of the heads of families, student names, the annual rent of chambers, the board per week, and a total amount.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

From the Introduction. The study of the European Court of Justice’s (ECJ) case law of the regarding the Area of Freedom Security and Justice (AFSJ) is fascinating in many ways.1 First, almost the totality of the relevant case law is extremely recent, thereby marking the first ‘foundational’ steps in this field of law. This is the result of the fact that the AFSJ was set up by the Treaty of Amsterdam in 1997 and only entered into force in May 1999.2 Second, as the AFSJ is a new field of EU competence, it sets afresh all the fundamental questions – both political and legal – triggered by European integration, namely in terms of: a) distribution of powers between the Union and its member states, b) attribution of competences between the various EU Institutions, c) direct effect and supremacy of EU rules, d) scope of competence of the ECJ, and e) measure of the protection given to fundamental rights. The above questions beg for answers which should take into account both the extremely sensible fields of law upon which the AFSJ is anchored, and the EU’s highly inconvenient three-pillar institutional framework.3 Third, and as a consequence of the above, the vast majority of the ECJ’s judgments relating to the AFSJ are a) delivered by the Full Court or, at least, the Grand Chamber, b) with the intervention of great many member states and c) often obscure in content. This is due to the fact that the Court is called upon to set the foundational rules in a new field of EU law, often trying to accommodate divergent considerations, not all of which are strictly legal.4 Fourth, the case law of the Court relating to the AFSJ, touches upon a vast variety of topics which are not necessarily related to one another. This is why it is essential to limit the scope of this study. The content of, and steering for, the AFSJ were given by the Tampere European Council, in October 1999. According to the Tampere Conclusions, the AFSJ should consist of four key elements: a) a common immigration and asylum policy, b) judicial cooperation in both civil and penal matters, c) action against criminality and d) external action of the EU in all the above fields. Moreover, the AFSJ is to a large extent based on the Schengen acquis. The latter has been ‘communautarised’5 by the Treaty of Amsterdam and further ‘ventilated’ between the first and third pillars by decisions 1999/435 and 1999/436.6 Judicial cooperation in civil matters, mainly by means of international conventions (such as the Rome Convention of 1981 on the law applicable to contractual obligations) and regulations (such as (EC) 44/20017 and (EC) 1348/20008) also form part of the AFSJ. However, the relevant case law of the ECJ will not be examined in the present contribution.9 Similarly, the judgments of the Court delivered in the course of Article 226 EC proceedings against member states, will be omitted.10 Even after setting aside the above case law and notwithstanding the fact that the AFSJ only dates as far back as May 1999, the judgments of the ECJ are numerous. A simple (if not simplistic) categorisation may be between, on the one hand, judgments which concern the institutional setting of the AFSJ (para. 2) and, on the other, judgments which are related to some substantive AFSJ policy (para. 3).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acc. originally for orchestra.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pl. no. 4.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pl. no. 5203-104.