872 resultados para Validation of test results
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. To use the Pediatric Rheumatology International Trials Organization (PRINTO) core set of outcome measures to develop a validated definition of improvement for the evaluation of response to therapy in juvenile systemic lupus erythematosus (SLE).Methods. Thirty-seven experienced pediatric rheumatologists from 27 countries, each of whom had specific experience in the assessment of juvenile SLE patients, achieved consensus on 128 patient profiles as being clinically improved or not improved. Using the physicians' consensus ratings as the gold standard measure, the chi-square, sensitivity, specificity, false-positive and false-negative rates, area under the receiver operating characteristic curve, and kappa level of agreement for 597 candidate definitions of improvement were calculated. Only definitions with a kappa value greater than 0.7 were retained. The top definitions were selected based on the product of the content validity score multiplied by its kappa statistic.Results. The definition of improvement with the highest final score was at least 50% improvement from baseline in any 2 of the 5 core set measures, with no more than 1 of the remaining worsening by more than 30%.Conclusion. PRINTO proposes a valid and reproducible definition of improvement that reflects well the consensus rating of experienced clinicians and that incorporates clinically meaningful change in core set measures in a composite end point for the evaluation of global response to therapy in patients with juvenile SLE. The definition is now proposed for use in juvenile SLE clinical trials and may help physicians to decide whether a child with SLE responded adequately to therapy.
Resumo:
STUDY OBJECTIVE: To validate hysteroscopic view with histology in cases of endometrial hyperplasia and cancer in patients with abnormal uterine bleeding (AUB)DESIGN: Retrospective study.(Canadian Task Force classification II-3).SETTING: University teaching hospitals in Rio de Janeiro and São Paulo, and private office in Rio de Janeiro.PATIENTS: Four thousand and fifty-four patients with AUB in whom hysteroscopic views were complete and the histologic result was conclusive.INTERVENTION: Four thousand and fifty-four office hysteroscopies with complete views and conclusive histologic results. The material for histologic examination was obtained through biopsy of the lesion in an outpatient unit or through the resection of the entire lesion in patients who underwent surgery. Histology was considered the gold standard and compared with the hysteroscopic view.MEASUREMENTS AND MAIN RESULTS: In the histology of the 4054 examinations, 613 (15.2%) were endometrial hyperplasia, and 105 (2.6%) were endometrial cancer. The most frequent hysteroscopic finding was endometrial polyps (31.2%). In endometrial hyperplasia, the sensitivity of the hysteroscopic view was 56.3% (95% CI 52.21-60.2%), specificity was 89.1% (95% CI 88.0%-90.1%), positive predictive value (PPV) was 48.0% (95% CI 44.3%-51.7%), negative predictive value (NPV) was 92.0% (95% Cl 90.1%-92.9%), and accuracy was 72.7% (95% CI 70.7%-74.7%). Accuracy was defined as the proportion of correct results among the hysteroscopic examinations. In endometrial cancer, the sensitivity of the hysteroscopic view was 80.0% (95% Cl 71.1%-87.2%), specificity was 99.5% (95% CI 99.2%-99.7%), PPV was 81.5% (95% Cl 72.7%-88.5%), NPV was 99.5% (95% CI 99.2%-99.7%), and accuracy was 89.8% (95% CI, 85.9%-93.6%). In the 814 patients (20.0%) in whom the hysteroscopic view was normal, there were no false negatives for endometrial cancer; however, there were 37 (4.5%) false negatives for endometrial hyperplasia. In the histologic cases of endometrial cancer, 101 (96.2%) hysteroscopic views were compatible with cancer or hyperplasia (80.0% and 16.2%, respectively). Ninety-seven out of 103 hysteroscopic views with cancer findings (94.2%) had histologic diagnosis of cancer or hyperplasia (81.5% and 12.6%, respectively).CONCLUSION: It seems that even in face of good validity of hysteroscopic view for endometrial hyperplasia and cancer, histologic study is mandatory in the presence of any lesion as the hysteroscopic view cannot completely replace the histologic study in patients with AUB. (C) 2006 AAGL. All rights reserved.
Resumo:
The objective of the present study was to develop and apply the direct immunohistochemistry (D-IHC) assay to search for turkey coronavirus (TCoV) antigens in formalin-fixed embedded-paraffin tissues by the use of biotin-labeled polyclonal antibody. Twenty-eight-day-old embryonated turkey eggs (n = 50) were inoculated with TCoV-purified virus, and 3 d after inoculation, sections from ileum, ileum-cecal junction, and ceca were harvested, fixed in neutral formalin, and embedded in paraffin blocks and used as positive control. In addition, a total of 100 field samples from ileum, ileum-cecal junction, and ceca, collected from 30 to 45-d-old turkeys poults experiencing an outbreak of acute enteritis, were used to search for TCoV by the same D-IHC. All results were compared with those obtained by conventional RT-PCR and indirect fluorescent antibody assay (IFA) for all tested samples. Turkey coronavirus was detected in experimentally infected embryo tissues and also in field samples in 100% of ileum-cecal junction and ceca by the 3 detection procedures. With IFA as a reference assay, sensitivity and specificity of D-IHC were 98 and 58%, whereas sensitivity and specificity of reverse transcription-PCR were 96 and 66%, calculated from the total of tested samples from experimental infection. Each of the examined procedures was highly specific (D-IHC, 93%; RT-PCR, 90%), sensitive (D-IHC, 85%; RT-PCR, 86%), and agreement of both D-IHC and RT-PCR was 99 and 100%, respectively, compared with IFA results obtained from all the field samples. These findings demonstrated the utility of D-IHC for direct detection of TCoV from field samples and considering the sensitivity and specificity found here, can be used as an alternative technique.
Resumo:
It was studied the trapezius muscle and serratus anterior muscle in 24 male volunteers using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes, during the execution of four different modalities of military press exercises with open grip. The results showed that TS acted significantly in the modalities standing and sitting press behind neck, while SI acted in all the modalities, i.e., standing and sitting press behind neck and forward, justifying their inclusion as basic exercises for physical conditioning programmes.
Resumo:
Based on the lack of electromyographic researches on sport and programmes of physical conditioning, we can say that it is necessary to reexamine some exercises routinely used in the programmes of physical conditioning. Thus, the trapezius and serratus anterior muscles were studied electromyographically so that we could evaluate the validity in some ways of execution of the frontal-lateral cross, dumbbells exercises for the development of these muscles. We analyzed 24 male volunteers, 18 to 25 years old, using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For the execution of the exercise it was used a supine bench, a straight board and two bars of 40 cm made of light wood. The results showed that TS acted preferentially in standing modality and in the inclined supine modality, however with activity levels that do not justify its inclusion in physical fitness programmes.
Resumo:
The trapezius and serratus anterior muscles were studied in four modalities of rowing exercises executed with two grips, middle and closed, in comparison with the four different modalities of frontal-lateral cross, dumbbells exercise. It was used 24 male volunteers, 18 to 25 years old using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. The results showed that TS acted in a higher significant way in all the modalities of rowing than in the supine lateral raise, inclined supine lateral raise and reverse supine lateral raise, dumbbells exercises, and demonstrated no standing frontal-lateral cross, dumbbells. The SI acted more significantly difference among all the execution modalities of rowing and the inclined supine lateral raise, dumbbells exercises than in all the rowing exercises; even though the activity levels do not make us suggest them as an excellent group of exercises for the development of this muscle.
Resumo:
Because the lack of textbooks based on electromyographic studies in the area of exercises for physical conditioning, the authors proposed to study the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles during the execution of four different modalities of rowing exercises with middle grip in 24 male volunteers, 18 to 25 years old. For the recordings, it was used a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For the movements, a supine bench and a 120 cm-long bar made of low weight wood were used. The results showed that TS acted significantly in upright, sitting and inclined rowing, justifying its inclusion in physical conditioning programmes, while SI, in spite of acting preferentially in upright and sitting rowing, presented activity levels which do not justify its inclusion.
Resumo:
The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.
Resumo:
Because the lack of specialized textbooks, the select of basic exercises for physical conditioning programmes is based on empirical knowledge. This fact led the authors to propose the study on electromyographic activity of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with closed grip in three different modalities. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a long bar made of light wood was used. TS acted significantly in the three different modalities, that is, upright, sitting and bent over, while SI acted preferentially in upright and sitting rowing exercises, justifying their inclusion as basic exercises in physical conditioning programmes.
Resumo:
Because the lack of specialized textbooks on the select and indication of basic exercises for physical conditioning programmes, an electromyographic study of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with middle and closed grip in three different modalities, upright, sitting and bent over was performed. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a supine bench, a straight board and a 1,20 m-long bar made of light wood were used. The results showed that TS acted preferentially with closed grip sitting and bent over modalities, and presented no difference among the grips for upright rowing. SI acted preferentially with closed grip in all modalities, however, with activity levels that do not justify its indication for physical conditioning programmes.
Resumo:
The action potential level for shoulder muscles deltoid-anterior portion (DA) and pectoralis major-clavicular portion (PMC) determined by four different modalities of execution of rowing exercises, each one with two different grips, was recorded. These were compared with the action potential level determined for the same muscles by four different modalities of execution of the frontal-lateral cross, dumbbells exercises. Twenty-four male volunteers were examined using a 2 channel TECA TE4 electromyograph and Hewlett Packard surface electrodes. The statistic analysis showed significant (p<0,05) superiority for all the frontal-lateral cross, dumbbells exercises in comparison to all rowing exercises for the PMC, for the DA this generalized supremacy was not observed.
Resumo:
A simple, sensitive and accurate spectrophotometric method was developed for the assay of gatifloxacin in raw material and tablets. Validation of the method yielded good results concerning range, linearity, precision and accuracy. The absorbance was measured at 287 nm for gatifloxacin tablet solutions. The linearity range was found to be 4.0-14.0 μg/mL for gatifloxacin. It was also found that the excipients in the commercial tablets did not interfere with the method.
Resumo:
A simple and reproducible method was developed for the assay of lomefloxacin in tablets. The excipients in the commercial tablet preparation did not interfere with the assay. Beer's law is obeyed in the range 2.0-9.0 μg.mL-1 at λmax 280 nm. The molar absorptivity was calculated. Six triplicate analyses of solutions containing six different concentrations of the examined drug were carried out and gave a mean correlation coefficient 0.9997. The proposed method was applied to the determination of the examined drug in coated tablet and the results demonstrated that the method is equally accurate, precise and reproducible as the official methods.