994 resultados para Toluidine blue test
Resumo:
The purpose of this study was to quantify the sagittal angular displacement of the head (cranio-cervical flexion) for the five incremental stages of the cranio-cervical flexion test (CCFT). Range of cranio-cervical flexion during the CCFT was measured using a digital imaging method in 20 healthy volunteer subjects. The intra- and inter-rater reliability of the digital imaging technique for the assessment of this movement were also examined. The results of this study demonstrated a linear relationship between the incremental pressure targets of the CCFT and the percentages of full range cranio-cervical flexion range of motion (ROM) measured in the supine lying position of the test using a digital imaging technique. A mean of 22.9% full range cranio-cervical flexion was used to reach the first pressure target of the CCFT followed by linear increments up to 76.6% for the last stage of the test. An increasing amount of cranio-cervical flexion ROM was used to achieve the five successive stages of the CCFT reflecting an increasing contractile demand on the deep cervical flexor muscles. Excellent inter-rater (ICC = 0.994) and intra-rater reliability (ICC = 0.988-0.998) were demonstrated for the angular measurements using this digital imaging technique. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
The Test of Mouse Proficiency (TOMP) was developed to assist occupational therapists and education professionals assess computer mouse competency skills in children from preschool to upper primary (elementary) school age. The preliminary reliability and validity of TOMP are reported in this paper. Methods used to examine the internal consistency, test-retest reliability, and criterion- and construct-related validity of the test are elaborated. In the continuing process of test refinement, these preliminary studies support to varying degrees the reliability and validity of TOMP. Recommendations for further validation of the assessment are discussed along with indications for potential clinical application.
Resumo:
The volume of the primary (PCS) and secondary (SCS) circulatory system in the Atlantic cod Gadus morhua was determined using a modified dye dilution technique. Cod (N=10) were chronically cannulated in the second afferent branchial artery with PE-50 tubing. Evans Blue dye was bound to harvested fish plasma at a concentration of 1 mg dye ml(-1) plasma, and injected at a concentration of 1 mg kg(-1) body mass. Serial sampling from the cannula produced a dye dilution curve, which could be described by a double exponential decay equation. Curve analysis enabled the calculation of the primary circulatory and total distribution volume. The difference between these volumes is assumed to be the volume of the SCS. From the dilution curve, it was also possible to calculate flow rates between and within the systems. The results of these experiments suggest a plasma volume in the PCS of 3.42+/-0.89 ml 100 g(-1) body mass, and in the SCS of 1.68+/-0.35 ml 100 g(-1) body mass (mean +/- S.D.) or approximately 50% that of the PCS. Flow rates to the SCS were calculated as 2.7% of the resting cardiac output. There was an allometric relationship between body mass and blood volumes. Increasing condition factor showed a tendency towards smaller blood volumes of the PCS, expressed as percentage body mass, but this was not evident for the volume of the SCS.
Resumo:
The large eyes and well-developed visual system of billfishes suggest that vision is an important sense for the detection and interception of prey and lures. Investigations of visual abilities in these large pelagic fishes are difficult, however anatomical studies of billfish eyes and retinas allow prediction of a number of visual capabilities. From the density of ganglion cells in the blue marlin (Makaira nigricans) retina, visual acuities of less than 10 cycles per degree were derived, a surprisingly low visual resolution given the absolute size of the marlin eye. Cone photoreceptors, on the other hand, were present in high densities, resulting in a presumed summation of cones to ganglion cells at a ratio of 40:1, even in the area of best vision. The optical sensitivity of the marlin eye was high owing to the large dimensions of the cone photoreceptors. These results indicate that the marlin eye is specifically adapted to cope with the low light levels encountered during diving. Since the marlin is likely to use its vision at depth, it is suggested that this line of research could help estimate the limits of vertical distribution based on light level.
Resumo:
Recent behavioural experiments have shown that birds use ultraviolet (UV)-reflective and fluorescent plumage as cues in mate choice. It remains controversial, however, whether such UV signals play a special role in sexual communication, or whether they are part of general plumage coloration. We use a comparative approach to test for a general association between sexual signalling and either UV-reflective or fluorescent plumage. Among the species surveyed, 72% have UV colours and there is a significant positive association between UV reflectance and courtship displays. Among parrots (Psittaciformes), 68% of surveyed species have fluorescent plumage, and again there is a strong positive association between courtship displays and fluorescence. These associations are not artefacts of the plumage used in courtship displays, being generally more 'colourful' because there is no association between display and colours lacking UV reflectance or fluorescence. Equally, these associations are not phylogenetic artefacts because all results remain unchanged when families or genera, rather than species, are used as independent data points. We also find that, in parrots, fluorescent plumage is usually found adjacent to UV-reflective plumage. Using a simple visual model to examine one parrot, the budgerigar Melopsittacus undulatus, we show that the juxtaposition of UV-reflective and fluorescent plumage leads to a 25-fold increase in chromatic contrast to the budgerigar's visual system. Taken together, these results suggest that signals based on UV contrast are of special importance in the context of active sexual displays. We review briefly six hypotheses on why this may be the case: suitability for short-range signalling; high contrast with backgrounds; invisibility to predators; exploitation of pre-existing sensory biases; advertisement of feather structure; and amplification of behavioural signals.
Resumo:
This paper reports a study that explored a new construct: climate of fear. We hypothesised that climate of fear would vary across work sites within organisations, but not across organisations. This is in contrast a to measures of organisational culture, which were expected to vary both within and across organisations. To test our hypotheses, we developed a new 13-item measure of perceived fear in organisations and tested it in 20 sites across two organisations (N = 209). Culture variables measured were innovative leadership culture, and communication culture. Results were that climate of fear did vary across sites in both organisations, while differences across organisations were not significant, as we anticipated. Organisational culture, however, varied between the organisations, and within one of the organisations. The climate of fear scale exhibited acceptable psychometric properties.
Resumo:
Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F-V/F-M ratio is used.
Resumo:
This study compares the performance of the Quickscreen and Default protocols of the ILO-96 Otodynamics Analyzer in recording transient evoked otoacoustic emissions (TEOAEs) from adults using clinical decision analysis. Data were collected from 25 males (mean age = 29.0 years, SD = 6.8) and 35 females (mean age = 28.1 years, SD = 9.6). The results showed that the mean signal-to-noise ratios obtained from the Quickscreen were significantly greater than those from the Default protocol at 1,2, and 4 kHz. The comparison of the performance of the two protocols, based on the results using receiver operating characteristics curves, revealed a higher performance of the Quickscreen than the Default protocol at 1 and 4 kHz but not at 2 kHz. In view of the enhanced performance of the Quickscreen over the Default protocol in general, the routine use of the Default protocol for testing adults in audiology clinics should be reconsidered.
Resumo:
mais consumida no país, e proscrita pela Lei n° 11.343 de 23 de agosto de 2006 (chamada de “nova lei de droga”), onde todos os isômeros, sais, éteres e ésteres do ∆9-Tetrahidrocannabinol (THC), princípio ativo, foram proscritos. O método utilizado pela Polícia Civil do Estado do Espírito Santo para a identificação de cannabinóides é o teste colorimétrico, por meio de solução básica de Salt Fast Blue B, o qual apresenta resultados falsos negativos e falsos positivos. A técnica de espectrometria de massas de altíssima resolução e exatidão de massas (ESI(-)FTICR MS), permite detectar os principais cannabinóides na forma de molécula desprotonada, íon [M-H]-. Alguns íons que podem ser identificados são: [CBN - H]- de m/z 309 (CBN = cannabinol); [THC - H]- de m/z 313 (THC = tetrahidrocannabinol) e [CBD - H]- de m/z 313; [CBC - H]- de m/z 327 (CBC = cannabicromeno); [CBEA - H]- de m/z 345 (CBEA = ácido cannabielsóico); [CBNA - H]- de m/z 353 (CBNA = ácido cannabinólico); [THCA - H]- de m/z 357 (THCA = ácido tetrahidrocannabinólico); [8α, 11-Bis-hydroxy-∆9-THC-A - H]- de m/z 389); [∆9-THCA +C2H2O - H]- de m/z 357; e dímeros com m/z de 637, 653, 673, 681, 685 e 717. Foram encontrados adulterantes identificados como [M + N + H]+ : 491; [2M + N + H]+ : 819 e [3M + N + H]+ : 1147, onde M = OTHC (328Da C21H28O3) e N = Nicotina (162Da C10H14N2), além de lidocaína e cocaína. Ainda foram identificados alguns noncannabinóides como Cannflavino A e B e ácidos graxos como palmítico, oleico, linolênico e gama-linolênico nos extratos de sementes de Cannabis. Este estudo tem o objetivo de identificar o perfil químico de amostras de maconha, apreendidas pela Polícia Civil do Estado do Espírito Santo, por ESI(±)-FT-ICR MS.
Resumo:
This article combines both international practice and analytical contributions into a systematic and synthetic presentation of the evolution of peace operations from their modern inception in 1948 to the present. It seeks to serve a didactic purpose in proposing a basic structure for Brazilian scholars' burgeoning debate on peace operations and intervention, rather than a definitive characterization of blue helmet practice. Peace operations' progression is traced through five analytical "generations," each adding a crucial factor distinguishing it from its predecessors. Each generation is placed in relation to changes in the nature of conflict and in the interpretation of the foundational principles of peace operations, and links to broader theoretical issues in International Relations are made explicit at each stage.
Resumo:
Foi aplicada uma versão reduzida do "Face-Hand Test", o FHT-R, em 91 pessoas com 65 anos ou mais em uma amostra ao acaso de idosos vivendo na comunidade (São Paulo, Brasil), com objetivo de testar a habilidade do instrumento em detectar as síndromes psicorgânicas. Os escores do FHT-R foram comparados com as avaliações de um psiquiatra utilizando uma entrevista semi-estruturada, a "Clinical Interview Schedule". Cinco pessoas foram consideradas como sendo portadoras de distúrbios psicorgânicos e 86 como não sendo portadoras de tais distúrbios. No ponto de corte 0/1 os coeficientes de validação obtidos foram: sensibilidade 60%, especificidade 94%, valor prognóstico positivo 38%, valor prognóstico negativo 98%, e taxa de classificação incorreta 8%. A utilização do Teste em pesquisas epidemiológicas é discutida no corpo do trabalho.
Resumo:
This paper studies the application of commercial biocides to old maritime pine timber structures (Pinus pinaster Ait.) that have previously been impregnated with other products. A method was developed in the laboratory to be used in situ to determine the impregnation depth achieved by a new generation biocide product applied to timber from an old building. This timber had once been treated with an unknown product difficult to characterize without extensive analysis. The test was initially developed in laboratory conditions and later tested on elements of the roof structure of an 18th century building. In both cases the results were promising and mutually consistent with penetration depths for some treatments reaching 2.0 cm. The application in situ proved the tests viability and simplicity of execution giving a clear indication on the feasibility of possible re-treatments.
Resumo:
This article reports on a-Si:H-based low-leakage blue-enhanced photodiodes for dual-screen x-ray imaging detectors. Doped nanocrystalline silicon was incorporated in both the n- and p-type regions to reduce absorption losses for light incoming from the top and bottom screens. The photodiode exhibits a dark current density of 900 pA/cm(2) and an external quantum efficiency up to 90% at a reverse bias of 5 V. In the case of illumination through the tailored p-layer, the quantum efficiency of 60% at a 400 nm wavelength is almost double that for the conventional a-Si:H n-i-p photodiode.