943 resultados para Standard alimentary


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for the direct determination of Se in nutritionally relevant foods by graphite furnace atomic absorption spectrometry. Tungsten/rhodium carbide coating on the integrated platform of a transversely heated graphite atomizer or W coating with co-injection of Pd(NO3)(2) were used as a permanent modifiers. Samples and reference solutions were spiked with 500 mu g L-1 As and absorbance variations due to changes in experimental conditions were minimized. For 20 mu L aqueous analytical solutions delivered into the graphite tube, analytical curves in the 5.0-40 mu g L-1 with good linear correlation were established. Pyrolysis and atomization temperatures were evaluated using pyrolysis and atomization curves, respectively. The optimized heating program (temperature, ramp time, hold time) of the graphite tube of the Perkin-Elmer SIMAA 6000 atomic absorption spectrometer was: dry steps (110 degrees C, 5 s, 10 s; 130 degrees C, 15 s, 15 s); air-assisted pyrolysis step (600 degrees C, 20 s, 40 s; 20 degrees C, 1 s, 40 s); pyrolysis step (1300 degrees C, 10 s, 20 s); atomization step (2100 degrees C, 0 s, 4 s); clean step (2550 degrees C, 1 s, 5 s). The method was applied for Se determination in coconut water, coconut milk, soybean milk, cow milk, tomato juice, mango juice, grape juice and drinking water samples and four standard reference materials and results were in agreement at 95% confidence level. The lifetime of the tube was 500 firings and the relative standard deviations of measurements of typical samples containing 25 mu gL(-1) Se were 3.0% and 6.0% (n = 12) with and without internal standardization, respectively. The limits of detection were in the 0.35 mu g L-1-0.7 mu g Se L-1 range. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values were in the 98-109% range. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The code STATFLUX, implementing a new and simple statistical procedure for the calculation of transfer coefficients in radionuclide transport to animals and plants, is proposed. The method is based on the general multiple-compartment model, which uses a system of linear equations involving geometrical volume considerations. Flow parameters were estimated by employing two different least-squares procedures: Derivative and Gauss-Marquardt methods, with the available experimental data of radionuclide concentrations as the input functions of time. The solution of the inverse problem, which relates a given set of flow parameter with the time evolution of concentration functions, is achieved via a Monte Carlo Simulation procedure.Program summaryTitle of program: STATFLUXCatalogue identifier: ADYS_v1_0Program summary URL: http://cpc.cs.qub.ac.uk/summaries/ADYS_v1_0Program obtainable from: CPC Program Library, Queen's University of Belfast, N. IrelandLicensing provisions: noneComputer for which the program is designed and others on which it has been tested: Micro-computer with Intel Pentium III, 3.0 GHzInstallation: Laboratory of Linear Accelerator, Department of Experimental Physics, University of São Paulo, BrazilOperating system: Windows 2000 and Windows XPProgramming language used: Fortran-77 as implemented in Microsoft Fortran 4.0. NOTE: Microsoft Fortran includes non-standard features which are used in this program. Standard Fortran compilers such as, g77, f77, ifort and NAG95, are not able to compile the code and therefore it has not been possible for the CPC Program Library to test the program.Memory, required to execute with typical data: 8 Mbytes of RAM memory and 100 MB of Hard disk memoryNo. of bits in a word: 16No. of lines in distributed program, including test data, etc.: 6912No. of bytes in distributed Program, including test data, etc.: 229 541Distribution format: tar.gzNature of the physical problem: the investigation of transport mechanisms for radioactive substances, through environmental pathways, is very important for radiological protection of populations. One such pathway, associated with the food chain, is the grass-animal-man sequence. The distribution of trace elements in humans and laboratory animals has been intensively studied over the past 60 years [R.C. Pendlenton, C.W. Mays, R.D. Lloyd, A.L. Brooks, Differential accumulation of iodine-131 from local fallout in people and milk, Health Phys. 9 (1963) 1253-1262]. In addition, investigations on the incidence of cancer in humans, and a possible causal relationship to radioactive fallout, have been undertaken [E.S. Weiss, M.L. Rallison, W.T. London, W.T. Carlyle Thompson, Thyroid nodularity in southwestern Utah school children exposed to fallout radiation, Amer. J. Public Health 61 (1971) 241-249; M.L. Rallison, B.M. Dobyns, F.R. Keating, J.E. Rall, F.H. Tyler, Thyroid diseases in children, Amer. J. Med. 56 (1974) 457-463; J.L. Lyon, M.R. Klauber, J.W. Gardner, K.S. Udall, Childhood leukemia associated with fallout from nuclear testing, N. Engl. J. Med. 300 (1979) 397-402]. From the pathways of entry of radionuclides in the human (or animal) body, ingestion is the most important because it is closely related to life-long alimentary (or dietary) habits. Those radionuclides which are able to enter the living cells by either metabolic or other processes give rise to localized doses which can be very high. The evaluation of these internally localized doses is of paramount importance for the assessment of radiobiological risks and radiological protection. The time behavior of trace concentration in organs is the principal input for prediction of internal doses after acute or chronic exposure. The General Multiple-Compartment Model (GMCM) is the powerful and more accepted method for biokinetical studies, which allows the calculation of concentration of trace elements in organs as a function of time, when the flow parameters of the model are known. However, few biokinetics data exist in the literature, and the determination of flow and transfer parameters by statistical fitting for each system is an open problem.Restriction on the complexity of the problem: This version of the code works with the constant volume approximation, which is valid for many situations where the biological half-live of a trace is lower than the volume rise time. Another restriction is related to the central flux model. The model considered in the code assumes that exist one central compartment (e.g., blood), that connect the flow with all compartments, and the flow between other compartments is not included.Typical running time: Depends on the choice for calculations. Using the Derivative Method the time is very short (a few minutes) for any number of compartments considered. When the Gauss-Marquardt iterative method is used the calculation time can be approximately 5-6 hours when similar to 15 compartments are considered. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the production of a charged-heavy-lepton pair considering the minimal supersymmetric standard model. We show that the cross section for the process pp --> gg --> l+l- is enhanced for large values of the ratio between the two-Higgs-doublet vacuum expectation values, in comparison with the standard model result. The gluon fusion mechanism is the most important contribution to the lepton pair production for M(l) > 50 GeV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bismuth was evaluated as an internal standard for the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru as a permanent modifier with co-injection of Pd/Mg(NO3)(2). The correlation coefficient of the graph plotted from the non-nalized absorbance signals of Bi versus Pb was r=0.989. Matrix effects were evaluated by analyzing the slope ratios between the analytical curve, and analytical curves obtained from Pb additions in red and white wine vinegar obtained from reference solutions prepared in 0.2% (v/v) HNO3, samples. The calculated ratios were around 1.04 and 1.02 for analytical curves established applying an internal standard and 1.3 and 1.5 for analvtical curves without. Analytical curves in the 2.5-15 pg L-1 Pb concentration interval were established using the ratio Pb absorbance to Bi absorbance versus analvte concentration, and typical linear correlations of r=0.999 were obtained. The proposed method was applied for direct determination of Pb in 18 commercial vinegar samples and the Pb concentration varied from 2.6 to 31 pg L-1. Results were in agreement at a 95% confidence level (paired t-test) with those obtained for digested samples. Recoveries of Pb added to vinegars varied from 96 to 108% with and from 72 to 86% without an internal standard. Two water standard reference materials diluted in vinegar sample were also analyzed and results were in agreement with certified values at a 95% confidence level. The characteristic mass was 40 pg Pb and the useful lifetime of the tube was around 1600 firings. The limit of detection was 0.3 mu g L-1 and the relative standard deviation was <= 3.8% and <= 8.3% (n = 12) for a sample containing, 10 mu L-1 Pb with and without internal standard, respectively. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Usually referral letters are the only means of communication between general practitioners and specialists in the health area. However, they are inadequate if important basic data are omitted. The aim of this study was to compare the content of standard and non-standard letters. A total of 1956 files from the Oral Medicine Service were consecutively evaluated (March 1996 to September 2000). Key items were considered for analysis and the results were stored in a database using the Epinfo 6.04 program. The X-2 test (a=0.05) was applied to the results. of the 1956 files examined, 34% (662) had a referral letter, 31% of them being standard letters and 69% non-standard letters. Most standard letters (87%) were from professionals of public health institutions. Most percent discrepancies between standard and non-standard letters were observed for patient address (14.90 vs 1.32%), patient age (54.81 vs 9.47%), chief complaint (32.21 vs 8.37%), fundamental lesion (29.33 vs 13.66%), and symptoms (27.81 vs 15.42%,,). Statistically significant differences were observed for patient age, professional referring the patient, chief complaint, and site of the lesion. The quality and quantity of the information differed significantly between the two types of letters. The standard letters were more complete and contained information commonly absent in the non-standard letters. We suggest the use of standard letters for improving the quality of communication among professionals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluoroindate glasses of the following compositions: (40-x)InF3-20ZnF(2)-16BaF(2)-20SrF(2)-2GdF(3)-2NaF-xTmF(3) with x = 1,3 mol% were prepared in a dry box under an argon atmosphere. The absorption spectra at room temperature in the spectral range 350-2200 nm were obtained. The spectra obtained for each sample had similar absorption and only the amplitude of the different bands changed as the concentration of Tm3+. The experimental oscillator strengths were determined from the areas under the absorption bands. Using the standard and modified Judd-Ofelt theory, intensity parameters Ohm(lambda) (lambda = 2,4,6) and (lambda = 2,3,4,5,6), respectively for f-f transitions of Tm3+ ions as well as transition probabilities, branching ratios and radiative lifetimes for each band were determined. The results are compared with those of other glasses described in the literature. (C) 1999 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article discusses the development of a test bench and a methodology for the study of composite resin abrasive wear. To evaluate the operation of the test bench and to compare the proposed methodology with other existing ones, a study was made of the five composites most commonly used by dentists.The one-way ANOVA method and the Tukey test were used to statistically analyze the results by multiple comparisons of the groups of resins tested. Using the proposed methodology, these resins were classified in an increasing order of abrasive wear strength, as follows: Charisma (the lowest abrasive wear strength), Tetric, TPH, Herculite and Z-100 (the highest abrasive wear strength) (P < 0.05). In comparison to other methodologies, the results of the proposed methodology presented the lowest coefficient of variation. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation of the microscopic generalized interacting boson model (GIBM) Hamiltonian, deduced from the general microscopic nuclear Hamiltonian via the collective O-A-1 invariant microscopic Hamiltonian of the general restricted dynamics model (RDM) in the case of central multipole and multipole-Gauss type effective NN-potential is briefly discussed. The GIBM version, which includes all sixth-order terms in the expansion of the collective part of the NN-potential, has been obtained. This GIBM Hamiltonian contains additional terms compared with the standard (sd-boson) interacting boson model (IBM). The microscopic expressions for the standard IBM Hamiltonian parameters in terms of the employed effective NN-potential parameters have also been obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To determine whether plasma protein concentrations were altered in ponies with alimentary laminitis.Animals-12 adult ponies.Procedure-Acute laminitis was induced in 6 ponies by oral administration of carbohydrate (85% corn starch, 15% wood flour); the other 6 ponies were used as controls. A physical examination was performed and blood samples were collected immediately before and 4, 8, 12, 24, and 28 hours after administration of carbohydrate. Plasma protein concentrations were determined by means of sodium dodecyl sulphate-polyacrylamide gel electrophoresis.Results-19 plasma proteins ranging from a molecular weight of 24,000 to a molecular weight of 350,000 were identified in all 12 ponies. Plasma concentrations of proteins with molecular weights of 350,000 (fibrinogen), 130,000 (ceruloplasmin), 118,000 (c-reactive protein), 67,000 (alpha(1)-antitrypsin I), 65,000 (alpha(1)-antitrypsin II), 50,000 (haptoglobulin), and 45,000 (acid glycoprotein) were significantly increased in ponies with laminitis, compared with concentrations in control ponies.Conclusion-Changes in plasma protein concentrations are detectable within 4 hours after the onset of alimentary laminitis in ponies.Clinical Relevance-Measurement of plasma protein concentrations may be useful in monitoring the progression of laminitis in ponies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of using internal standardization (IS) to correct for interferences in hydride generation with in situ trapping in graphite furnace was evaluated. Arsenic was chosen as internal standard for Sb determination and Ir was used as permanent modifier. Fluctuations in the main parameters that affect the analytical results were minimized by IS and an effective contribution was verified in the studies of liquid phase interferences. Cobalt and Ni2+ were selected to illustrate the potential use of IS on the correction of interference by transition metals. The application of IS allows the Sb determination in samples containing up to 20-fold higher concentration of the Co2+ and Ni2+ when compared to the procedure without IS. The relative standard deviation of measurements varied from 0.3% to 0.7% and from 1.1% to 3.2% with and without IS, respectively. Recoveries within 92% and 107% of spiked aqueous solution containing Sb(III) and Sb(V) were found. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The need for standardization of the measured blow count number N-spt into a normalized reference energy value is now fully recognized. The present paper extends the existing theoretical approach using the wave propagation theory as framework and introduces an analysis for large displacements enabling the influence of rod length in the measured N-spt values to be quantified. The study is based on both calibration chamber and field tests. Energy measurements are monitored in two different positions: below the anvil and above the sampler. Both experimental and numerical results demonstrate that whereas the energy delivered into the rod stem is expressed as a ratio of the theoretical free-fall energy of the hammer, the effective sampler energy is a function of the hammer height of fall, sampler permanent penetration, and weight of both hammer and rods. Influence of rod length is twofold and produces opposite effects: wave energy losses increase with increasing rod length and in a long rod composition the gain in potential energy from rod weight is significant and may partially compensate measured energy losses. Based on this revised approach, an analytical solution is proposed to calculate the energy delivered to the sampler and efficiency coefficients are suggested to account for energy losses during the energy transference process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated if overfed rats present morphological and histochemical muscle adaptation similar to normally fed, both submitted to two different weekly frequencies of training. Thirty male Wistar rats were fed either with standard chow (SCO) or with hypercaloric diet (HCO). They were subdivided into six subgroups: sedentary (SCO and HCO), trained twice/week (SC2 and HC2) and trained five times/week (SC5 and HC5). The trained groups swam 60 min/day, during 10 weeks. Twenty four hours after the last training, samples of Gastrocnemius were excised and stained with HE, NADH-TR and m-ATPase, and the capillary density was calculated. Total heart mass (HM) and the mass of atrium (AM), left (LV) and right (RV) ventricles were excised and weighted. The comparisons were made by ANOVA and by Covariance analysis, adjusting the variables by body weight. The results showed that the HCO achieved higher BM, however, absolute HM did not differ post training. Irrespective of the diet, rats that were trained twice a week presented significantly greater increase in the AM. In general, the SC5 and HC5 groups showed higher HM, LV, RV, proportion of oxidative fibres and capillary density, compared to the sedentary and twice week trained groups. A higher proportion of injuries (splitting) was noted in the HC2 and HC5 compared to SC2 and SC5. These results indicate that the frequency of training influenced the skeletal and heart adaptation and larger changes were observed in the 5x/week group, which ingested the standard diet. The 5x/week training groups also presented large amount of muscle fibres damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)