955 resultados para Six van Vromade, P. H.


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Commissioning studies of the CMS hadron calorimeter have identified sporadic uncharacteristic noise and a small number of malfunctioning calorimeter channels. Algorithms have been developed to identify and address these problems in the data. The methods have been tested on cosmic ray muon data, calorimeter noise data, and single beam data collected with CMS in 2008. The noise rejection algorithms can be applied to LHC collision data at the trigger level or in the offline analysis. The application of the algorithms at the trigger level is shown to remove 90% of noise events with fake missing transverse energy above 100 GeV, which is sufficient for the CMS physics trigger operation. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 μm, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12 000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers. Using a large sample of cosmic muon events collected by CMS in 2008, the field in the steel of the barrel yoke has been determined with a precision of 3 to 8% depending on the location. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a broad range of muon momenta, and were found to be in good agreement with expectations from Monte Carlo simulation. The relative momentum resolution for muons crossing the barrel part of the detector is better than 1% at 10 GeV/c and is about 8% at 500 GeV/c, the latter being only a factor of two worse than expected with ideal alignment conditions. Muon charge misassignment ranges from less than 0.01% at 10GeV/c to about 1% at 500 GeV/c. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A measurement of the underlying activity in scattering processes with pT scale in the GeV region is performed in proton-proton collisions at √ = 0.9 TeV, using data collected by the CMS experiment at the LHC. Charged particle production is studied with reference to the direction of a leading object, either a charged particle or a set of charged particles forming a jet. Predictions of several QCD-inspired models as implemented in PYTHIA are compared, after full detector simulation, to the data. The models generally predict too little production of charged particles with pseudorapidity {pipe}η{pipe} < 2, pT > 0.5 GeV/c, and azimuthal direction transverse to that of the leading object. © 2010 CERN for benefit of the CMS collaboration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The production of J/ψ mesons is studied in pp collisions at √s = 7 TeV with the CMS experiment at the LHC. The measurement is based on a dimuon sample corresponding to an integrated luminosity of 314 nb-1. The J/ψ differential cross section is determined, as a function of the J/ψ transverse momentum, in three rapidity ranges. A fit to the decay length distribution is used to separate the prompt from the non-prompt (b hadron to J/ψ) component. Integrated over J/ψ transverse momentum from 6.5 to 30 GeV/c and over rapidity in the range {pipe}y{pipe} < 2.4, the measured cross sections, times the dimuon decay branching fraction, are 70.9 ± 2.1(stat.) ± 3.0(syst.) ± 7.8(luminosity) nb for prompt J/ψ mesons assuming unpolarized production and 26.0 ± 1.4(stat.) ± 1.6(syst.) ± 2.9(luminosity) nb for J/ψ mesons from b-hadron decays. © CERN for the benefit of the CMS collaboration 2011.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

First measurements of dihadron correlations for charged particles are presented for central PbPb collisions at a nucleon-nucleon center-of-mass energy of 2.76TeV over a broad range in relative pseudorapidity (Δν) and the full range of relative azimuthal angle (Δø). The data were collected with the CMS detector, at the LHC. A broadening of the away-side (Δø y≈ π) azimuthal correlation is observed at all Δν, as compared to the measurements in pp collisions. Furthermore, long-range dihadron correlations in Δν are observed for particles with similar ø values. This phenomenon, also known as the \ridge, persists up to at least jΔνj = 4. For particles with transverse momenta (pT) of 2-4 GeV/c, the ridge is found to be most prominent when these particles are correlated with particles of pT = 2-6 GeV/c, and to be much reduced when paired with particles of pT = 10-12 GeV/c. Copyright CERN.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurements of inclusive W and Z boson production cross sections in pp collisions at √s = 7 TeV are presented, based on 2.9 pb-1 of data recorded by the CMS detector at the LHC. The measurements, performed in the electron and muon decay channels, are combined to give σ(pp → WX) × B(W → l?) = 9.95 ± 0.07 (stat.) ± 0.28 (syst.) ± 1.09 (lumi.) nb and σ(pp → ZX) × B(Z → l +l-) = 0.931 ± 0.026 (stat.) ± 0.023 (syst.) ± 0.102 (lumi.) nb, where l stands for either e or μ. Theoretical predictions, calculated at the next-to-next-to-leading order in QCD using recent parton distribution functions, are in agreement with the measured cross sections. Ratios of cross sections, which incur an experimental systematic uncertainty of less than 4%, are also reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Drell-Yan differential cross section is measured in pp collisions at √ s = 7TeV, from a data sample collected with the CMS detector at the LHC, corresponding to an integrated luminosity of 36 pb-1. The cross section measurement, normalized to the measured cross section in the Z region, is reported for both the dimuon and dielectron channels in the dilepton invariant mass range 15{600 GeV. The normalized cross section values are quoted both in the full phase space and within the detector acceptance. The effect of final state radiation is also identified. The results are found to agree with theoretical predictions. Copyright CERN.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The charged particle transverse momentum (pT) spectra are presented for pp collisions at √s = 0:9 and 7TeV. The data samples were collected with the CMS detector at the LHC and correspond to integrated luminosities of 231 μb-1 and 2.96 pb-1, respectively. Calorimeter-based high-transverse-energy triggers are employed to enhance the statistical reach of the high-pT measurements. The results are compared with leading and next-toleading order QCD and with an empirical scaling of measurements at different collision energies using the scaling variable xT - 2pT=ps over the pT range up to 136 GeV/c. Using a combination of xT scaling and direct interpolation at fixed pT, a reference transverse momentum spectrum at √s = 2:76TeV is constructed, which can be used for studying high-pT particle suppression in the dense QCD medium produced in heavy-ion collisions at that centre-of-mass energy. Copyright CERN.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Results are reported from a search for physics beyond the standard model in proton-proton collisions at a center-of-mass energy of 7TeV, focusing on the signature with a single, isolated, high-transverse-momentum lepton (electron or muon), energetic jets, and large missing transverse momentum. The data sample comprises an integrated luminosity of 36 pb-1, recorded by the CMS experiment at the LHC. The search is motivated by models of new physics, including supersymmetry. The observed event yields are consistent with standard model backgrounds predicted using control samples obtained from the data. The characteristics of the event sample are consistent with those expected for the production of tt̄ and W+jets events. The results are interpreted in terms of limits on the parameter space for the constrained minimal supersymmetric extension of the standard model.