990 resultados para Single lung ventilation
Resumo:
This paper presents an analysis of the performance of a baseband multiple-input single-output (MISO) time reversal ultra-wideband system (TR-UWB) incorporating a symbol spaced decision feedback equalizer (DFE). A semi-analytical performance analysis based on a Gaussian approach is considered, which matched well with simulation results, even for the DFE case. The channel model adopted is based on the IEEE 802.15.3a model, considering correlated shadowing across antenna elements. In order to provide a more realistic analysis, channel estimation errors are considered for the design of the TR filter. A guideline for the choice of equalizer length is provided. The results show that the system`s performance improves with an increase in the number of transmit antennas and when a symbol spaced equalizer is used with a relatively small number of taps compared to the number of resolvable paths in the channel impulse response. Moreover, it is possible to conclude that due to the time reversal scheme, the error propagation in the DFE does not play a role in the system`s performance.
Resumo:
This work considers the open-loop control problem of steering a two-level quantum system from any initial to any final condition. The model of this system evolves on the state space X = SU(2), having two inputs that correspond to the complex amplitude of a resonant laser field. A symmetry preserving flat output is constructed using a fully geometric construction and quaternion computations. Simulation results of this flatness-based open-loop control are provided.
Resumo:
Hub-and-spoke networks are widely studied in the area of location theory. They arise in several contexts, including passenger airlines, postal and parcel delivery, and computer and telecommunication networks. Hub location problems usually involve three simultaneous decisions to be made: the optimal number of hub nodes, their locations and the allocation of the non-hub nodes to the hubs. In the uncapacitated single allocation hub location problem (USAHLP) hub nodes have no capacity constraints and non-hub nodes must be assigned to only one hub. In this paper, we propose three variants of a simple and efficient multi-start tabu search heuristic as well as a two-stage integrated tabu search heuristic to solve this problem. With multi-start heuristics, several different initial solutions are constructed and then improved by tabu search, while in the two-stage integrated heuristic tabu search is applied to improve both the locational and allocational part of the problem. Computational experiments using typical benchmark problems (Civil Aeronautics Board (CAB) and Australian Post (AP) data sets) as well as new and modified instances show that our approaches consistently return the optimal or best-known results in very short CPU times, thus allowing the possibility of efficiently solving larger instances of the USAHLP than those found in the literature. We also report the integer optimal solutions for all 80 CAB data set instances and the 12 AP instances up to 100 nodes, as well as for the corresponding new generated AP instances with reduced fixed costs. Published by Elsevier Ltd.
Resumo:
In previous studies, we presented main strategies for suspending the rotor of a mixed-flow type (centrifugal and axial) ventricular assist device (VAD), originally presented by the Institute Dante Pazzanese of Cardiology (IDPC), Brazil. Magnetic suspension is achieved by the use of a magnetic bearing architecture in which the active control is executed in only one degree of freedom, in the axial direction of the rotor. Remaining degrees of freedom, excepting the rotation, are restricted only by the attraction force between pairs of permanent magnets. This study is part of a joint project in development by IDPC and Escola Politecnica of Sao Paulo University, Brazil. This article shows advances in that project, presenting two promising solutions for magnetic bearings. One solution uses hybrid cores as electromagnetic actuators, that is, cores that combine iron and permanent magnets. The other solution uses actuators, also of hybrid type, but with the magnetic circuit closed by an iron core. After preliminary analysis, a pump prototype has been developed for each solution and has been tested. For each prototype, a brushless DC motor has been developed as the rotor driver. Each solution was evaluated by in vitro experiments and guidelines are extracted for future improvements. Tests have shown good results and demonstrated that one solution is not isolated from the other. One complements the other for the development of a single-axis-controlled, hybrid-type magnetic bearing for a mixed-flow type VAD.
Resumo:
This paper analyzes the complexity-performance trade-off of several heuristic near-optimum multiuser detection (MuD) approaches applied to the uplink of synchronous single/multiple-input multiple-output multicarrier code division multiple access (S/MIMO MC-CDMA) systems. Genetic algorithm (GA), short term tabu search (STTS) and reactive tabu search (RTS), simulated annealing (SA), particle swarm optimization (PSO), and 1-opt local search (1-LS) heuristic multiuser detection algorithms (Heur-MuDs) are analyzed in details, using a single-objective antenna-diversity-aided optimization approach. Monte- Carlo simulations show that, after convergence, the performances reached by all near-optimum Heur-MuDs are similar. However, the computational complexities may differ substantially, depending on the system operation conditions. Their complexities are carefully analyzed in order to obtain a general complexity-performance framework comparison and to show that unitary Hamming distance search MuD (uH-ds) approaches (1-LS, SA, RTS and STTS) reach the best convergence rates, and among them, the 1-LS-MuD provides the best trade-off between implementation complexity and bit error rate (BER) performance.
Resumo:
This paper addresses the single machine scheduling problem with a common due date aiming to minimize earliness and tardiness penalties. Due to its complexity, most of the previous studies in the literature deal with this problem using heuristics and metaheuristics approaches. With the intention of contributing to the study of this problem, a branch-and-bound algorithm is proposed. Lower bounds and pruning rules that exploit properties of the problem are introduced. The proposed approach is examined through a computational comparative study with 280 problems involving different due date scenarios. In addition, the values of optimal solutions for small problems from a known benchmark are provided.
Resumo:
This work discusses a 4D lung reconstruction method from unsynchronized MR sequential images. The lung, differently from the heart, does not have its own muscles, turning impossible to see its real movements. The visualization of the lung in motion is an actual topic of research in medicine. CT (Computerized Tomography) can obtain spatio-temporal images of the heart by synchronizing with electrocardiographic waves. The FOV of the heart is small when compared to the lung`s FOV. The lung`s movement is not periodic and is susceptible to variations in the degree of respiration. Compared to CT, MR (Magnetic Resonance) imaging involves longer acquisition times and it is not possible to obtain instantaneous 3D images of the lung. For each slice, only one temporal sequence of 2D images can be obtained. However, methods using MR are preferable because they do not involve radiation. In this paper, based on unsynchronized MR images of the lung an animated B-Repsolid model of the lung is created. The 3D animation represents the lung`s motion associated to one selected sequence of MR images. The proposed method can be divided in two parts. First, the lung`s silhouettes moving in time are extracted by detecting the presence of a respiratory pattern on 2D spatio-temporal MR images. This approach enables us to determine the lung`s silhouette for every frame, even on frames with obscure edges. The sequence of extracted lung`s silhouettes are unsynchronized sagittal and coronal silhouettes. Using our algorithm it is possible to reconstruct a 3D lung starting from a silhouette of any type (coronal or sagittal) selected from any instant in time. A wire-frame model of the lung is created by composing coronal and sagittal planar silhouettes representing cross-sections. The silhouette composition is severely underconstrained. Many wire-frame models can be created from the observed sequences of silhouettes in time. Finally, a B-Rep solid model is created using a meshing algorithm. Using the B-Rep solid model the volume in time for the right and left lungs were calculated. It was possible to recognize several characteristics of the 3D real right and left lungs in the shaded model. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
We demonstrate anisotropic etching of single-layer graphene by thermally activated nickel nanoparticles. Using this technique, we obtain sub-10-nm nanoribbons and other graphene nanostructures with edges aligned along a single crystallographic direction. We observe a new catalytic channeling behavior, whereby etched cuts do not intersect, resulting in continuously connected geometries. Raman spectroscopy and electronic measurements show that the quality of the graphene is resilient under the etching conditions, indicating that this method may serve as a powerful technique to produce graphene nanocircuits with well-defined crystallographic edges.
Resumo:
The aim of this work is the production and preliminary characterization of adsorbent new materials useful for sensor development. A new plasma chamber was simulated and designed in order to obtain multiple layers and/or composites in a single step. Plasma deposited organic fluorocompound and hexamethyldisilazane (HMDS) thin films were produced and tested as adsorbent layers. Chemical characterization used ellipsometry, Raman. infrared and X-ray photoelectron spectroscopy. Hydrophobic and oleophobic character were determined by contact angle measurements. Adsorption characteristics were evaluated using quartz crystal microbalance. Not only HMDS but also the fluorocompound can polymerize but intermixing and a double layer are only obtained in very narrow conditions. The films are adsorbent and mildly hydrophobic. Films deposited on a microchromatographic column can be used on sample pretreatment to remove and/or preconcentrate volatile organic Compounds. Therefore, with this approach it is possible to obtain films with different monomers on double layer or composites, with organic/inorganic materials or particles and use them on sample pretreatment for chemical analysis. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Data on fertilisation and embryo quality in dairy cattle are presented and the main factors responsible for the low fertility of single-ovulating lactating cows and embryo yield in superovulated dairy cattle are highlighted. During the past 50 years, the fertility in high-producing lactating dairy cattle has decreased as milk production increased. Recent data show conception rates to first service to be approximately 32% in lactating cows, whereas in heifers it has remained above 50%. Fertilisation does not seem to be the principal factor responsible for the low fertility in single-ovulating cows, because it has remained above 80%. Conversely, early embryonic development is impaired in high-producing dairy cows, as observed by most embryonic losses occurring during the first week after fertilisation. However, in superovulated dairy cattle, although fertilisation failure is more pronounced, averaging approximately 45%, the percentage of fertilised embryos viable at 1 week is quite high (>70%). Among the multifactorial causes of low fertility in lactating dairy cows, high feed intake associated with low concentrations of circulating steroids may contribute substantially to reduced embryo quality. Fertilisation failure in superovulated cattle may be a consequence of inappropriate gamete transport due to hormonal imbalances.
Resumo:
The variability of a fragment of the nucleocapsid gene of orchid fleck virus (OFV) was investigated by single-strand conformational polymorphism (SSCP) analysis and nucleotide sequencing. Forty-eight samples of 18 genera of orchids were collected from Brazil, Costa Rica and Australia. The SSCP analysis yielded six different band patterns, and phylogenetic analysis based on the nucleotide fragment sequence obtained in this work and six available in GenBank showed two different groups, one with isolates 023Germany and So-Japan, and other with the rest of the isolates. None of the analyses showed geographic correlation among the Brazilian strains. The data obtained in this study showed a low genetic variation in this region of the genome; the d(N)/d(S) ratio of 0.251-0.405 demonstrated a negative selective pressure that maintains the stability of the analyzed fragments.
Resumo:
Background: Tramadol is a well tolerated and effective analgesic used to treat moderate to severe pain. Several generic formulations of tramadol are available in Brazil; however, published information regarding their bioequivalence in the Brazilian population is not available. A study was designed for Brazilian regulatory authorities to allow marketing of a generic formulation. Objective: The purpose of this study was to compare the bioequivalence of 2 commercial tablet preparations containing tramadol 100 mg marketed for use in Brazil. Methods: A randomized, open-label, 2 x 2 crossover study was performed in healthy Brazilian volunteers under fasting conditions with a washout period of 12 days. Two tablet formulations of tramadol 100 mg (test and reference formulations) were administered as a single oral dose, and blood samples were collected over 24 hours. Tramadol plasma concentrations were quantified using a validated HPLC method. A plasma concentration time profile was generated for each volunteer and then mean values were determined, from which C(max), T(max), AUC(0-t), AUC(0-infinity), k(e), and t(1/2) were calculated using a noncompartmental model. Bioequivalence between the products was determined by calculating 90% CIs for the ratios of C(max), AUC(0-t), and AUC(0-infinity) values for the test and reference products using log-transformed data. Tolerability was assessed by monitoring vital signs (temperature, blood pressure, heart rate), laboratory tests (hematology, blood biochemistry, hepatic function, urinalysis), and interviews with the volunteers before medication administration and every 2 hours during the study. Results: Twenty-six healthy volunteers (13 men, 13 women) were enrolled in and completed the study. Mean (SD) age was 30 (6.8) years (range, 21-44 years), mean weight was 64 (8.3) kg (range, 53-79 kg), and mean height was 166 (6.4) cm (range, 155-178 cm). The 90% CIs for the ratios of C(max) (1.01-1.17), AUC(0-t) (1.00-1.13), and AUC(0-infinity) (1.00-1.14) values for the test and reference products fell within the interval of 0.80 to 1.25 proposed by most regulatory agencies, including the Brazilian regulatory body. No clinically important adverse effects were reported; only mild somnolence was reported by 4 volunteers and mild headaches by 5 volunteers, and there was no need to use medication to treat these symptoms. Conclusion: Pharmacokinetic analysis in these healthy Brazilian volunteers suggested that the test and reference formulations of tramadol 100-mg tablets met the regulatory requirements to assume bio-equivalence based on the Brazilian regulatory definition. (Clin Ther 2010;32:758-765) (C) 2010 Excerpta Medica Inc.
Resumo:
Adsorption of Ni(2+), Zn(2+) or Pb(2+) by dry biomass of Arthrospira (Spirulina) platensis and Chlorella vulgaris was studied as a function of contact time and initial metal concentration. The zero point of charge calculated for these biosorbents (pH(zpc) 4.0 and 3.4, respectively) and additional pH tests suggested the use of pH in the range 5.0-5.5 for the experiments. The equilibrium isotherms were evaluated in terms of maximum sorption capacity and sorption affinity. The pseudo first and second order kinetic models were considered to interpret the experimental data, and the latter best described the adsorption system. Both the Freundlich and Langmuir models were shown to well describe the sorption isotherms, thus suggesting an intermediate mono/multilayer sorption mechanism. Compared to A. platensis (q(e) = 0.354, 0.495 and 0.508 mmol g(-1) for Ni(2+), Pb(2)+ and Zn(2+), respectively), C. vulgaris behaved as a better biosorbent because of higher equilibrium sorption capacity (q(e) = 0.499, 0.634 and 0.664 mmol g(-1), respectively). The removal efficiency decreased with increasing metal concentration, pointing out a passive adsorption process involving the active sites on the surface of the biomasses. The FT-IR spectroscopy evidenced that ions removal occurred mainly by interaction between metal and carboxylate groups present on both the cell walls. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The purpose of this study was to compare the pharmacokinetics of tetracycline in plasma, synovial fluid, and milk following either a single systemic intravenous (i.v.) injection or a single i.v. regional antibiosis (IVRA) administration of tetracycline hydrochloride to dairy cattle with papillomatous digital dermatitis (PDD). To this end, plasma and synovial fluid tetracycline concentrations were compared with the minimal inhibitory concentration (MIC) values of the major bacteria, which are known to cause digital diseases and thus assess its efficacy in PDD. Residual tetracycline concentrations in milk from cows treated by both methods were also determined. Twelve Holstein cows with various stages of PDD were randomly assigned to two groups of six animals. Group 1 received a single systemic i.v. injection of 10 mg/kg of tetracycline hydrochloride. Group 2 received 1000 mg of tetracycline hydrochloride by IVRA of the affected limb. Blood, synovial fluid and milk samples were taken prior to tetracycline administration (time 0 control), and then at 22, 45 and 82 min, and 2, 3, 4, 6, 8, 12, 24, 48, 72, 96, and 120 h following drug administration. Tetracycline concentrations were determined by high-performance liquid chromatography. Mean tetracycline plasma and milk concentrations in Group 1 were higher than Group 2. The opposite was observed for synovial fluid concentrations. Group 2 synovial fluid concentrations were higher than the MIC value over 24 h for the bacteria most frequently responsible for claw disease. Compared with i.v. administration, IVRA administration of tetracycline produced very high synovial fluid and low plasma and milk concentrations.
Resumo:
Background: Zidovudine is a thymidine nucleoside reverse transcriptase inhibitor with activity against HIV type 1. Some (similar to 8) generic formulations of zidovudine are available in Brazil; however, based on a literature search, information concerning their bioavailability and pharmacokinetic properties in the Brazilian population has not been reported. Objective: The aim of this study was to compare the bioavailability and pharmacokinetic properties of 2 capsule formulations of zidovudine 100 mg in healthy Brazilian volunteers. Methods: This open-label, randomized, 2-way crossover study utilized a 1-week washout period between doses. Blood samples were collected for 8 hours after a single dose of zidovudine 100-mg test (Zidovudina, Fundaqdo para o Remedio Popular, Sao Paulo, Brazil) or reference formulation (Retrovir (R), GlaxoSmithKline, Philadelphia, Pennsylvania). Plasma zidovudine concentrations were determined using a validated high-performance liquid chromatography method with ultraviolet detection at 265 nm. C-max, T-max, AUC(0-t), AUC(0-infinity), t(1/2), and the elimination constant (k(e)) were determined using noncompartmental analysis. The formulations were considered bioequivalent if the 90% CIS for C-max, AUC(0-t), and AUC(0-infinity) fell within the interval of 80 % to 125 %, the regulatory definition set by the US Food and Drug Administration (FDA). Results: Twenty-four healthy volunteers (12 males, 12 females; mean age, 27 years; weight, 60 kg; height, 167 cm) were enrolled and completed the study. The 90% CIs of the treatment ratios for the logarithmic-transformed values of C-max, AUC(0-t), and AUC(0-infinity) were 80.0% to 113.6%, 93.9% to 109.7%, and 93.6% to 110.1 %, respectively. The values for the test and reference formulations were within the FDA bioequivalence definition intervals of 80% to 125%. Conclusions: In this small study in healthy subjects, no statistically significant differences in C-max, AUC(0-t), and AUC(0-)infinity were found between the test and reference formulations of zidovudine 100-mg capsules. The 90% CIs for the mean ratio values for the test and reference formulations of AUC(0-t), AUC(0-infinity), and C-max indicated that the reported data were entirely within the bioequivalence acceptance range proposed by the FDA of 80% to 125% (using log-transformed data).