996 resultados para Sediment quality


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Measurement and improvement of quality of care is a priority issue in health care. Patients hospitalized with acute coronary syndromes (ACS) constitute a high-risk population whose care, if shown to be suboptimal on the basis of available research evidence, may benefit from quality improvement interventions. Aim: To evaluate the quality of in-hospital care for patients with ACS, using explicit quality indicators. Methods: Retrospective case note review was undertaken of 397 patients admitted to three teaching hospitals in Brisbane, Queensland, Australia, between 1 October 2000 and 17 April 2001. The main out-come measures were 12 process-of-care quality indicators, calculated as either: (i) the proportion of all patients who received specific interventions or (ii) the proportion of ideal patients who received -specific interventions (i.e. patients with clear indi-cations and lacking contraindications). Results: Quality indicators with values above 80% included: (i) patient selection for thrombolysis (100%) and discharge prescription of beta-blockers (84%), (ii) antiplatelet agents (94%) and (iii) lipid-lowering agents (82%). Indicators with values between 50% and 80% included: (i) timely per-formance of electrocardiogram (ECG) on admission (61%), (ii) early coronary angiography (75%), (iii) measurement of serum lipids (71%) and (iv) discharge prescription of angiotensin-converting-enzyme (ACE) inhibitors (73%). Indicators with values <50% included: (i) timely administration of thrombolysis (35%), (ii) non-invasive risk assessment (23%) and (ii) formal in-hospital and post-hospital cardiac rehabilitation (47% and 7%, respectively). Conclusion: There were delays in performing ECG and administering thrombolysis to patients who presented to emergency departments with ACS. Improvement is warranted in use of non-invasive procedures for identifying high-risk patients who may benefit from coronary revascularization as well as use of serum lipid measurements, ACE inhibitors and cardiac rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is shown that the observed difference in sediment transporting efficiency by the swash uprush, compared with the downrush, could be mainly due to greater bed shear stress for a given velocity in the more abruptly accelerated uprush. The bed shear stress generated by an arbitrary free stream velocity time series is modelled in terms of usual wave boundary layer models plus a phase lead (phi(tau) of the bed shear stress compared with the free stream velocity at the peak frequency. With this approach, the total transport amounts in uprush and downrush can be modelled satisfactorily with the same sediment transport formula, without the need for different uprush and downrush coefficients. While the adaptation of sediment transport formulae from steady flow can thus lead to the right total amounts of sediment moved by this method, the timing of the instantaneous sediment transport rates are probably not accurately modelled due to the highly unsteady nature of the swash and the presence of pre-suspended sediment in the uprush. Nevertheless, the proposed method is a useful intermediate step before we have a complete understanding of sediment transport under very rapid accelerations and of the relative contribution of pre-suspended sediment to the onshore sediment transport in swash zones. (C) 2002 Published by Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method is provided for calculating transport rates of not too fine (d(50) greater than or equal to 0.20 mm) sand under sheet flow conditions. The method consists of a Meyer-Peter-type transport formula operating on a time-varying Shields parameter, which accounts for both acceleration-asymmetry and boundary layer streaming. While velocity moment formulae, e.g.., = Constant x calibrated against U-tube measurements, fail spectacularly under some real waves (Ribberink, J.S., Dohmen-Janssen, C.M., Hanes, D.M., McLean, S.R., Vincent, C., 2000. Near-bed sand transport mechanisms under waves. Proc. 27th Int. Conf. Coastal Engineering, Sydney, ASCE, New York, pp. 3263-3276, Fig. 12), the new method predicts the real wave observations equally well. The reason that the velocity moment formulae fail under these waves is partly the presence of boundary layer streaming and partly the saw-tooth asymmetry, i.e., the front of the waves being steeper than the back. Waves with saw-tooth asymmetry may generate a net landward sediment transport even if = 0, because of the more abrupt acceleration under the steep front. More abrupt accelerations are associated with thinner boundary layers and greater pressure gradients for a given velocity magnitude. The two real wave effects are incorporated in a model of the form Q(s)(t) = Q(s)[theta(t)] rather than Q(S)(t) = Q(S)[u(infinity)(t)], i.e., by expressing the transport rate in terms of an instantaneous Shields parameter rather than in terms of the free stream velocity, and accounting for both streaming and accelerations in the 0(t) calculations. The instantaneous friction velocities u(*)(t) and subsequently theta(t) are calculated as follows. Firstly, a linear filter incorporating the grain roughness friction factor f(2.5) and a phase angle phi(tau) is applied to u(infinity)(t). This delivers u(*)(t) which is used to calculate an instantaneous grain roughness Shields parameter theta(2.5)(t). Secondly, a constant bed shear stress is added which corresponds to the streaming related bed shear stress -rho ($) over bar((u) over tilde(w) over tilde)(infinity) . The method can be applied to any u(infinity)(t) time series, but further experimental validation is recommended before application to conditions that differ strongly from the ones considered below. The method is not recommended for rippled beds or for sheet flow with typical prototype wave periods and d(50) < 0.20 turn. In such scenarios, time lags related to vertical sediment movement become important, and these are not considered by the present model. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time series of vertical sediment fluxes are derived from concentration time series in sheet flow under waves. While the concentrations C(z,t) vary very little with time for \z\ < 10d(50), the measured vertical sediment fluxes Q(zs)(z,t) vary strongly with time in this vertical band and their time variation follows, to some extent, the variation of the grain roughness Shields parameter 02,5(t). Thus, sediment distribution models based on the pickup function boundary condition are in some qualitative agreement with the measurements. However, the pickup function models are only able to model the upward bursts of sediment during the accelerating phases of the flow. They are, so far, unable to model the following strong downward sediment fluxes, which are observed during the periods of flow deceleration. Classical pickup functions, which essentially depend on the Shields parameter, are also incapable of modelling the secondary entrainment fluxes, which sometimes occur at free stream velocity reversal. The measured vertical fluxes indicate that the effective sediment settling velocity in the high [(0.3 < C(z,t) < 0.4] concentration area is typically only a few percent of the clear water settling velocity, while the measurements of Richardson and Jeronimo [Chem. Eng. Sci. 34 (1979) 1419], from a different physical setting, lead to estimates of the order 20%. The data does not support gradient diffusion as a model for sediment entrainment from the bed. That is, detailed modelling of the observed near-bed fluxes would require diffusivities that go negative during periods of flow deceleration. An observed general trend for concentration variability to increase with elevation close to the bed is also irreconcilable with diffusion models driven by a bottom boundary condition. (C) 2002 Published by Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perceptual voice analysis is a subjective process. However, despite reports of varying degrees of intrajudge and interjudge reliability, it is widely used in clinical voice evaluation. One of the ways to improve the reliability of this procedure is to provide judges with signals as external standards so that comparison can be made in relation to these anchor signals. The present study used a Klatt speech synthesizer to create a set of speech signals with varying degree of three different voice qualities based on a Cantonese sentence. The primary objective of the study was to determine whether different abnormal voice qualities could be synthesized using the built-in synthesis parameters using a perceptual study. The second objective was to determine the relationship between acoustic characteristics of the synthesized signals and perceptual judgment. Twenty Cantonese-speaking speech pathologists with at least three years of clinical experience in perceptual voice evaluation were asked to undertake two tasks. The first was to decide whether the voice quality of the synthesized signals was normal or not. The second was to decide whether the abnormal signals should be described as rough, breathy, or vocal fry. The results showed that signals generated with a small degree of aspiration noise were perceived as breathiness while signals with a small degree of flutter or double pulsing were perceived as roughness. When the flutter or double pulsing increased further, tremor and vocal fry, rather than roughness, were perceived. Furthermore, the amount of aspiration noise, flutter, or double pulsing required for male voice stimuli was different from that required for the female voice stimuli with a similar level of perceptual breathiness and roughness. These findings showed that changes in perceived vocal quality could be achieved by systematic modifications of synthesis parameters. This opens up the possibility of using synthesized voice signals as external standards or anchors to improve the reliability of clinical perceptual voice evaluation. (C) 2002 Acoustical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microbiological quality of routinely processed tripe and rumen pillars were compared with those derived after emptying the rumen (paunch) without using water (dry dumping) and after deliberately bursting the paunches before processing. Prior to packing the mean:log(10) aerobic plate counts (APC) for the routinely processed tripe and rumen pillars were 3.55+/-1.08 and 3.28+/-0.87/g respectively. The corresponding mean log(10) total coliform counts (TCC) were 1.27+/-1.28 and 2.08+/-0.87. The mean log(10) APC counts on tripe and rumen pillars after dry-dumping were 3.06+/-0.60 and 3.90+/-0.75/g, respectively. The corresponding mean log(10) TCC were 1.03+/-0.60/g and 2.75+/-1.14/g respectively. After deliberately bursting the paunches, before processing, the mean log(10) APC counts on tripe and rumen pillars were 3.55+/-0.83/g and 3.50+/-0.59/g and the mean log(10) TCC were 1.54+/-0.95/g and 2.66+/-0.82/g respectively. In all cases the prevalence of Salmonella and Campylobacter spp. was less than 3%. The results indicate that both tripe and rumen pillars can be produced after dry dumping without compromising the quality of tripe and rumen pillars. Similarly, incidentally burst paunches that become contaminated with ingesta on the serosal surface can be processed without compromising product quality. Crown Copyright (C) 2002 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raw macadamia kernel pieces were immersed in water (specific gravity 1.00 g/cm(3)), brine (SG 1.02 g/cm(3)) or ethanol solution (SG 0.97 g/cm(3)) for 30 or 60 s, then re-dried to below 1.5% moisture (wet basis) and stored under vacuum for 0, 4 and 12 months. Flotation in water had no effect on the quality or shelf life of the kernel pieces over 12 months storage, as measured by sensory evaluation of the kernels and chemical analysis of the kernel oil. Immersion in a salt solution caused unacceptable changes in quality during storage, increasing as storage time increased. Flotation in dilute ethanol also caused unacceptable quality changes during storage. Therefore, only flotation of macadamia kernel pieces in water can be recommended for commercial operations. Microbiological concerns with such a process still need to be addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the variation in quality of 'Hass' avocado fruit within an orchard, fruit were harvested at commercial maturity from 15 'Hass' trees of similar appearance, growing in three adjacent rows on the same soil type, and receiving similar management. Fruit were harvested at commercial maturity, and either ripened at 22 degreesC or stored at 2 or 7 degreesC for 3 or 5 weeks and then ripened. Significant positive correlations (based, on the mean for each datum tree) were noted between fruit flesh calcium (Ca) and magnesium (Mg) concentrations and the (Ca + Mg)/potassium ratio, and the number of days for the fruit to reach the eating ripe stage (DTR). Negative correlations were also observed between these minerals and anthracnose and mesocarp discolouration (MD) severity. Negative correlations were observed between fruit potassium (K) and phosphorus (P) concentrations and DTR. Fruit from trees with high fruit yield were generally smaller, with lower anthracnose and MD severity, ripened more slowly, and had higher flesh Ca concentrations. It is likely that cultural practices that maintain moderate to high fruit yield and reduce variation in yield will improve avocado fruit quality and reduce variability in quality. Since the main differences between adjacent trees in this trial were the seedling rootstocks of unknown origin, it is suggested that rootstocks can have a significant impact on avocado yield and fruit quality. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrofluoric acid (HF) was used to pre-treat forest soils of south-east Queensland for assessing the effectiveness of iron (Fe) removal, carbon (C) composition using C-13 cross-polarisation (CP) with magic-angle-spinning (MAS) nuclear magnetic resonance (NMR) before and after the HF pre-treatment, and the improvement of C-13 CPMAS NMR spectra. Soil samples were collected from 4 experimental sites of different soil types, harvest residue management or prescribed burning, and tree species. More than 86% of Fe was in all soil types removed by the HF treatment. The C-13 NMR spectral quality was improved with increased resolution, especially in the alkyl C and O-alkyl C regions, and reduced NMR run-time (1-5 h per sample compared with >20 h per sample without the pre-treatment). The C composition appeared to alter slightly after the pre-treatment, but this might be largely due to improved spectrometer conditions and increased resolution leading to more accurate NMR spectral integration. Organic C recovery after HF pre-treatment varied with soil types and forest management, and soluble soil organic matter (SOM) could be lost during the pre-treatment. The Fourier Transform-Infrared (FT-IR) spectra of HF extracts indicated the preferential removal of carboxylic C groups during the pre-treatment, but this could also be due to adsorbed water on the mineral matter. The NMR spectra revealed some changes in C composition and quality due to residue management and decomposition. Overall, the HF treatment was a useful pre-treatment for obtaining semi-quantitative C-13 CPMAS NMR spectra of subtropical Australian forest soils.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of change in land-use from native vegetation to pasture (20-71 yr after conversion), and subsequent change from pasture to eucalypt plantation (7-10 yr after conversion) on soil organic matter quality was investigated using C-13 CP/MAS NMR spectroscopy. We studied surface soil (0-10 cm) from six sites representing a range of soil, and climate types from south-western Australia. Total C in the samples ranged from 1.6 to 5.5%, but the relative proportions of the four primary spectral regions (alkyl, O-alkyl, aromatic and carboxylic) were similar across the sites, and changes due to land-use at each site were relatively minor. Main impacts of changed land-use were higher O-alkyl (carbohydrate) material under pasture than under native vegetation and plantation (P = 0.048), and lower aromatic C under pasture than under native vegetation (P = 0.027). The decrease in aromatic C in pasture soils was related to time since clearing. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whole macadamia kernels were immersed in water (specific gravity 1.00 g/cm(3)), brine (SG 1.02 g/cm(3)) and ethanol solution (SG 0.97 g/cm(3)) for 30 or 60 s, re-dried to 1.0-1.5% moisture (wet basis) and stored under vacuum for 0, 4 and 12 months. Immersion in water had no effect on the quality or shelf life of kernels, as measured by sensory evaluation and analysis of the kernel oil. Immersion in brine and ethanol solutions changed the flavour of kernels, but had no effect on shelf life or kernel oil stability over 12 months storage. Water flotation to separate kernels based on differences in oil content is therefore feasible, but microbiological concerns need to be investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared the quality of realtime fetal ultrasound images transmitted using ISDN and IP networks. Four experienced obstetric ultrasound specialists viewed standard recordings in a randomized trial and rated the appearance of 30 fetal anatomical landmarks, each on a seven-point scale. A total of 12 evaluations were performed for various combinations of bandwidths (128, 384 or 768 kbit/s) and networks (ISDN or IF). The intraobserver coefficient of variation was 2.9%, 5.0%, 12.7% and 14.7% for the four observers. The mean overall ratings by each of the four observers were 4.6, 4.8, 5.0 and 5.3, respectively (a rating of 4 indicated satisfactory visualization and 7 indicated as good as the original recording). Analysis of variance showed that there were no significant interobserver variations nor significant differences in the mean scores for the different types of videoconferencing machines used. The most significant variable affecting the mean score was the bandwidth used. For ISDN, the mean score was 3.7 at 128 kbit/s, which was significantly worse than the mean score of 4.9 at 384 kbit/s, which was in turn significantly worse than the mean score of 5.9 at 768 kbit/s. The mean score for transmission using IP was about 0.5 points lower than that using ISDN across all the different bandwidths, but the differences were not significant. It appears that IP transmission in a private (non-shared) network is an acceptable alternative to ISDN for fetal tele-ultrasound and one deserving further study.