993 resultados para LASER data
Resumo:
The Greenland NEEM (North Greenland Eemian Ice Drilling) operation in 2010 provided the first opportunity to combine trace-gas measurements by laser spectroscopic instruments and continuous-flow analysis along a freshly drilled ice core in a field-based setting. We present the resulting atmospheric methane (CH4) record covering the time period from 107.7 to 9.5 ka b2k (thousand years before 2000 AD). Companion discrete CH4 measurements are required to transfer the laser spectroscopic data from a relative to an absolute scale. However, even on a relative scale, the high-resolution CH4 data set significantly improves our knowledge of past atmospheric methane concentration changes. New significant sub-millennial-scale features appear during interstadials and stadials, generally associated with similar changes in water isotopic ratios of the ice, a proxy for local temperature. In addition to the midpoint of Dansgaard–Oeschger (D/O) CH4 transitions usually used for cross-dating, sharp definition of the start and end of these events brings precise depth markers (with ±20 cm uncertainty) for further cross-dating with other palaeo- or ice core records, e.g. speleothems. The method also provides an estimate of CH4 rates of change. The onsets of D/O events in the methane signal show a more rapid rate of change than their endings. The rate of CH4 increase associated with the onsets of D/O events progressively declines from 1.7 to 0.6 ppbv yr−1 in the course of marine isotope stage 3. The largest observed rate of increase takes place at the onset of D/O event #21 and reaches 2.5 ppbv yr−1.
Resumo:
We measured the elemental composition on a sample of Allende meteorite with a miniature laser ablation mass spectrometer. This Laser Mass Spectrometer (LMS) has been designed and built at the University of Bern in the Department of Space Research and Planetary Sciences with the objective of using such an instrument on a space mission. Utilising the meteorite Allende as the test sample in this study, it is demonstrated that the instrument allows the in situ determination of the elemental composition and thus mineralogy and petrology of untreated rocky samples, particularly on planetary surfaces. In total, 138 measurements of elemental compositions have been carried out on an Allende sample. The mass spectrometric data are evaluated and correlated with an optical image. It is demonstrated that by illustrating the measured elements in the form of mineralogical maps, LMS can serve as an element imaging instrument with a very high spatial resolution of µm scale. The detailed analysis also includes a mineralogical evaluation and an investigation of the volatile element content of Allende. All findings are in good agreement with published data and underline the high sensitivity, accuracy and capability of LMS as a mass analyser for space exploration.
Resumo:
Ex vivo porcine retina laser lesions applied with varying laser power (20 mW–2 W, 10 ms pulse, 196 lesions) are manually evaluated by microscopic and optical coherence tomography (OCT) visibility, as well as in histological sections immediately after the deposition of the laser energy. An optical coherence tomography system with 1.78 um axial resolution specifically developed to image thin retinal layers simultaneously to laser therapy is presented, and visibility thresholds of the laser lesions in OCT data and fundus imaging are compared. Optical coherence tomography scans are compared with histological sections to estimate the resolving power for small optical changes in the retinal layers, and real-time time-lapse scans during laser application are shown and analyzed quantitatively. Ultrahigh-resolution OCT inspection features a lesion visibility threshold 40–50 mW (17 reduction) lower than for visual inspection. With the new measurement system, 42 of the lesions that were invisible using state-of-the-art ophthalmoscopic methods could be detected.
Resumo:
OBJECTIVE Fractured endodontic instruments inhibit optimal cleaning and filling of dental root canals, which may result in a less favorable prognosis for the tooth. Several techniques are available to remove fractured instruments; however, healthy tooth substance often must be destroyed in the process. This study was intended to evaluate Nd:YAG laser treatment as a method to remove fractured stainless steel instruments without destroying healthy tooth substance. METHOD AND MATERIALS Stainless steel endodontic instruments were fractured in 33 unprocessed root canals of mandibular central and lateral incisors and premolars in vitro. A brass tube charged with solder was placed at the coronal end of the fractured instrument and laser energy was used to melt the solder, connecting the fractured instrument with the brass tube. The success rates of connecting and removal of fractured instruments from the root channel were recorded for each case. RESULTS Connecting was achieved in every case in which more than 1.5 mm of the fractured instrument was tangible (22 out of 22). In cases where less than 1.5 mm was tangible, the rate for successful connection decreased to 4 out of 11 (36.4%). Fractured endodontic instruments were removed successfully in 17 out of 22 cases (77.3%) in which more than 1.5 mm was tangible. If less than 1.5 mm was tangible, the removal success rate decreased to 3 out of 11 cases (27.3%). CONCLUSION Our data support Nd:YAG laser-mediated connecting of a brass tube to a fractured endodontic instrument as a feasible and tissue conserving removal approach when more than 1.5 mm of the instrument is tangible.
Resumo:
We used real-time LDI to study regional variations in microcirculatory perfusion in healthy candidates to establish a new methodology for global perfusion body mapping that is based on intra-individual perfusion index ratios. Our study included 74 (37 female) healthy volunteers aged between 22 and 30 years (mean 24.49). Imaging was performed using a recent microcirculation-imaging camera (EasyLDI) for different body regions of each volunteer. The perfusion values were reported in Arbitrary Perfusion Units (APU). The relative perfusion indexes for each candidate's body region were then obtained by normalization with the perfusion value of the forehead. Basic parameters such as weight, height, and blood pressure were also measured and analyzed. The highest mean perfusion value was reported in the forehead area (259.21APU). Mean perfusion in the measured parts of the body correlated positively with mean forehead value, while there was no significant correlation between forehead blood perfusion values and room temperature, BMI, systolic blood pressure and diastolic blood pressure (p=0.420, 0.623, 0.488, 0.099, respectively). Analysis of the data showed that perfusion indexes were not significantly different between male and female volunteers except for the ventral upper arm area (p=.001). LDI is a non-invasive, fast technique that opens several avenues for clinical applications. The mean perfusion indexes are useful in clinical practice for monitoring patients before and after surgical interventions. Perfusion values can be predicted for different body parts for patients only by taking the forehead perfusion value and using the perfusion index ratios to obtain expected normative perfusion values.
Resumo:
Retinal laser photocoagulation is an established and successful treatment for a variety of retinal diseases. While being a valuable treatment modality, laser photocoagulation shows the drawback of employing high energy lasers which are capable of physically destroying the neural retina. For reliable therapy, it is therefore crucial to closely monitor the therapy effects caused in the retinal tissue. A depth resolved representation of optical tissue properties as provided by optical coherence tomography may provide valuable information about the treatment effects in the retinal layers if recorded simultaneously to laser coagulation. Therefore, in this work, the use of ultra-high resolution optical coherence tomography to represent tissue changes caused by conventional and selective retinal photocoagulation is investigated. Laser lesions were placed on porcine retina ex-vivo using a 577 nm laser as well as a pulsed laser at 527 nm built for selective treatment of the retinal pigment epithelium. Applied energies were varied to generate lesions best representing the span from under- to overtreatment. The lesions were examined using a custom-designed optical coherence tomography system with an axial resolution of 1.78 μm and 70 kHz Ascan rate. Optical coherence tomography scans included volume scans before and after irradiation, as well as time lapse scans (Mscan) of the lesions. Results show OCT lesion visibility thresholds to be below the thresholds of ophthalmoscopic inspection. With the ultra-high resolution OCT, 42% - 44% of ophthalmoscopically invisible lesions could be detected and lesions that were under- or overexposed could be distinguished using the OCT data.
Resumo:
We present the results from a simultaneous estimation of the gravity field, Earth rotation parameters, and station coordinates from combined SLR solutions incorporating up to nine geodetic satellites: LAGEOS-1/2, Starlette, Stella, AJISAI, Beacon-C, Lares, Blits and LARES. These solutions cover all three pillars of satellite geodesy and ensure full consistency between the Earth rotation parameters, gravity field coefficients, and geometry-related parameters. We address benefits emerging from such an approach and discuss particular aspects and limitations of the gravity field recovery using SLR data. The current accuracy of SLR-derived polar motion, by the means of WRMS w.r.t. IERS-08-C04 series, is at a level of 118-149 μas, which corresponds to 4 to 5 mm on the Earth’s surface. The WRMS of SLR-derived Length-of-Day, when the gravity field parameters are simultaneously estimated, is 56 μs/day, corresponding to about 26 mm on the ground, and the mean bias of SLR-derived Length-of-Day is 6.3 μs/day, corresponding to 3 mm.
Resumo:
OBJECTIVE The aim of this study was to investigate the effect of different energy settings of Er:YAG laser irradiation on dentin surface morphology with respect to the number of opened dentinal tubules. BACKGROUND DATA An ideally prepared dentin surface with opened dentinal tubules is a prerequisite for adhesive fixation. No study, however, has yet compared the numbers of opened dentinal tubules with regard to statistical differences. METHODS Conventional preparations using a bur with or without additional acid etching acted as control groups. Dentin specimens were prepared from human third molars and randomly divided into eight groups according to the energy settings of the laser (1, 1.5, 4, 6, 7.5, and 8 W) and two controls (bur and bur plus acid etching). After surface preparation, dentin surfaces were analyzed with a scanning electron microscope, and the number of opened dentinal tubules in a defined area was counted. RESULTS The control groups showed smooth surfaces with (bur plus acid etching) and without opened dentinal tubules (bur), whereas all laser-irradiated surfaces showed rough surfaces. Using the energy setting of 4 W resulted in significantly more opened dentinal tubules than the conventional preparation technique using the bur with additional acid etching. In contrast, the energy setting of 8 W showed significantly fewer opened dentinal tubules, and also exhibited signs of thermal damage. CONCLUSIONS The Er:YAG laser with an energy setting of 4 W generates a dentin surface with opened dentinal tubules, a prerequisite for adhesive fixation.
Resumo:
BACKGROUND Hirsutism occurs in 5% to 10% of women of reproductive age when there is excessive terminal hair growth in androgen-sensitive areas (male pattern). It is a distressing disorder with a major impact on quality of life. The most common cause is polycystic ovary syndrome. There are many treatment options, but it is not clear which are most effective. OBJECTIVES To assess the effects of interventions (except laser and light-based therapies alone) for hirsutism. SEARCH METHODS We searched the Cochrane Skin Group Specialised Register, CENTRAL (2014, Issue 6), MEDLINE (from 1946), EMBASE (from 1974), and five trials registers, and checked reference lists of included studies for additional trials. The last search was in June 2014. SELECTION CRITERIA Randomised controlled trials (RCTs) in hirsute women with polycystic ovary syndrome, idiopathic hirsutism, or idiopathic hyperandrogenism. DATA COLLECTION AND ANALYSIS Two independent authors carried out study selection, data extraction, 'Risk of bias' assessment, and analyses. MAIN RESULTS We included 157 studies (sample size 30 to 80) comprising 10,550 women (mean age 25 years). The majority of studies (123/157) were 'high', 30 'unclear', and four 'low' risk of bias. Lack of blinding was the most frequent source of bias. Treatment duration was six to 12 months. Forty-eight studies provided no usable or retrievable data, i.e. lack of separate data for hirsute women, conference proceedings, and losses to follow-up above 40%.Primary outcomes, 'participant-reported improvement of hirsutism' and 'change in health-related quality of life', were addressed in few studies, and adverse events in only half. In most comparisons there was insufficient evidence to determine if the number of reported adverse events differed. These included known adverse events: gastrointestinal discomfort, breast tenderness, reduced libido, dry skin (flutamide and finasteride); irregular bleeding (spironolactone); nausea, diarrhoea, bloating (metformin); hot flushes, decreased libido, vaginal dryness, headaches (gonadotropin-releasing hormone (GnRH) analogues)).Clinician's evaluation of hirsutism and change in androgen levels were addressed in most comparisons, change in body mass index (BMI) and improvement of other clinical signs of hyperandrogenism in one-third of studies.The quality of evidence was moderate to very low for most outcomes.There was low quality evidence for the effect of two oral contraceptive pills (OCPs) (ethinyl estradiol + cyproterone acetate versus ethinyl estradiol + desogestrel) on change from baseline of Ferriman-Gallwey scores. The mean difference (MD) was -1.84 (95% confidence interval (CI) -3.86 to 0.18).There was very low quality evidence that flutamide 250 mg, twice daily, reduced Ferriman-Gallwey scores more effectively than placebo (MD -7.60, 95% CI -10.53 to -4.67 and MD -7.20, 95% CI -10.15 to -4.25). Participants' evaluations in one study with 20 participants confirmed these results (risk ratio (RR) 17.00, 95% CI 1.11 to 259.87).Spironolactone 100 mg daily was more effective than placebo in reducing Ferriman-Gallwey scores (MD -7.69, 95% CI -10.12 to -5.26) (low quality evidence). It showed similar effectiveness to flutamide in two studies (MD -1.90, 95% CI -5.01 to 1.21 and MD 0.49, 95% CI -1.99 to 2.97) (very low quality evidence), as well as to finasteride in two studies (MD 1.49, 95% CI -0.58 to 3.56 and MD 0.40, 95% CI -1.18 to 1.98) (low quality evidence).Although there was very low quality evidence of a difference in reduction of Ferriman-Gallwey scores for finasteride 5 mg to 7.5 mg daily versus placebo (MD -5.73, 95% CI -6.87 to -4.58), it was unlikely it was clinically meaningful. These results were reinforced by participants' assessments (RR 2.06, 95% CI 0.99 to 4.29 and RR 11.00, 95% CI 0.69 to 175.86). However, finasteride showed inconsistent results in comparisons with other treatments, and no firm conclusions could be reached.Metformin demonstrated no benefit over placebo in reduction of Ferriman-Gallwey scores (MD 0.05, 95% CI -1.02 to 1.12), but the quality of evidence was low. Results regarding the effectiveness of GnRH analogues were inconsistent, varying from minimal to important improvements.We were unable to pool data for OCPs with cyproterone acetate 20 mg to 100 mg due to clinical and methodological heterogeneity between studies. However, addition of cyproterone acetate to OCPs provided greater reductions in Ferriman-Gallwey scores.Two studies, comparing finasteride 5 mg and spironolactone 100 mg, did not show differences in participant assessments and reduction of Ferriman-Gallwey scores (low quality evidence). Ferriman-Gallwey scores from three studies comparing flutamide versus metformin could not be pooled (I² = 62%). One study comparing flutamide 250 mg twice daily with metformin 850 mg twice daily for 12 months, which reached a higher cumulative dosage than two other studies evaluating this comparison, showed flutamide to be more effective (MD -6.30, 95% CI -9.83 to -2.77) (very low quality evidence). Data showing reductions in Ferriman-Gallwey scores could not be pooled for four studies comparing finasteride with flutamide as the results were inconsistent (I² = 67%).Studies examining effects of hypocaloric diets reported reductions in BMI, but which did not result in reductions in Ferriman-Gallwey scores. Although certain cosmetic measures are commonly used, we did not identify any relevant RCTs. AUTHORS' CONCLUSIONS Treatments may need to incorporate pharmacological therapies, cosmetic procedures, and psychological support. For mild hirsutism there is evidence of limited quality that OCPs are effective. Flutamide 250 mg twice daily and spironolactone 100 mg daily appeared to be effective and safe, albeit the evidence was low to very low quality. Finasteride 5 mg daily showed inconsistent results in different comparisons, therefore no firm conclusions can be made. As the side effects of antiandrogens and finasteride are well known, these should be accounted for in any clinical decision-making. There was low quality evidence that metformin was ineffective for hirsutism and although GnRH analogues showed inconsistent results in reducing hirsutism they do have significant side effects.Further research should consist of well-designed, rigorously reported, head-to-head trials examining OCPs combined with antiandrogens or 5α-reductase inhibitor against OCP monotherapy, as well as the different antiandrogens and 5α-reductase inhibitors against each other. Outcomes should be based on standardised scales of participants' assessment of treatment efficacy, with a greater emphasis on change in quality of life as a result of treatment.
Resumo:
In situ and simultaneous measurement of the three most abundant isotopologues of methane using mid-infrared laser absorption spectroscopy is demonstrated. A field-deployable, autonomous platform is realized by coupling a compact quantum cascade laser absorption spectrometer (QCLAS) to a preconcentration unit, called trace gas extractor (TREX). This unit enhances CH4 mole fractions by a factor of up to 500 above ambient levels and quantitatively separates interfering trace gases such as N2O and CO2. The analytical precision of the QCLAS isotope measurement on the preconcentrated (750 ppm, parts-per-million, µmole mole−1) methane is 0.1 and 0.5 ‰ for δ13C- and δD-CH4 at 10 min averaging time. Based on repeated measurements of compressed air during a 2-week intercomparison campaign, the repeatability of the TREX–QCLAS was determined to be 0.19 and 1.9 ‰ for δ13C and δD-CH4, respectively. In this intercomparison campaign the new in situ technique is compared to isotope-ratio mass spectrometry (IRMS) based on glass flask and bag sampling and real time CH4 isotope analysis by two commercially available laser spectrometers. Both laser-based analyzers were limited to methane mole fraction and δ13C-CH4 analysis, and only one of them, a cavity ring down spectrometer, was capable to deliver meaningful data for the isotopic composition. After correcting for scale offsets, the average difference between TREX–QCLAS data and bag/flask sampling–IRMS values are within the extended WMO compatibility goals of 0.2 and 5 ‰ for δ13C- and δD-CH4, respectively. This also displays the potential to improve the interlaboratory compatibility based on the analysis of a reference air sample with accurately determined isotopic composition.