988 resultados para Infrared devices
Resumo:
The Ajax approach has outgrown its origin as shorthand for "Asynchronous JavaScript + XML". Three years after its naming, Ajax has become widely adopted by web applications. Therefore, there exists a growing interest in using those applications with mobile devices. This thesis evaluates the presentational capability and measures the performance of five mobile browsers on the Apple iPhone and Nokia models N95 and N800. Performance is benchmarked through user-experienced response times as measured with a stopwatch. 12 Ajax toolkit examples and 8 production-quality applications are targeted, all except one in their real environments. In total, over 1750 observations are analyzed and included in the appendix. Communication delays are not considered; the network connection type is WLAN. Results indicate that the initial loading time of an Ajax application can often exceed 20 seconds. Content reordering may be used to partially overcome this limitation. Proper testing is the key for success: the selected browsers are capable of presenting Ajax applications if their differing implementations are overcome, perhaps using a suitable toolkit.
Resumo:
An overview of the human side of the wearable technology trend in the medical industry. Forecasted as the next wave of technological innovations, wearable and physically embedded medical devices to help manage patients’ health conditions are set to change the healthcare experience for both patients and healthcare providers. The idea here is to pay closer attention to how particular patients experience these devices, so they can be designed with empathy for specific patient needs to maintain optimum health.
Resumo:
Real-time scheduling algorithms, such as Rate Monotonic and Earliest Deadline First, guarantee that calculations are performed within a pre-defined time. As many real-time systems operate on limited battery power, these algorithms have been enhanced with power-aware properties. In this thesis, 13 power-aware real-time scheduling algorithms for processor, device and system-level use are explored.
Resumo:
In recent years, XML has been accepted as the format of messages for several applications. Prominent examples include SOAP for Web services, XMPP for instant messaging, and RSS and Atom for content syndication. This XML usage is understandable, as the format itself is a well-accepted standard for structured data, and it has excellent support for many popular programming languages, so inventing an application-specific format no longer seems worth the effort. Simultaneously with this XML's rise to prominence there has been an upsurge in the number and capabilities of various mobile devices. These devices are connected through various wireless technologies to larger networks, and a goal of current research is to integrate them seamlessly into these networks. These two developments seem to be at odds with each other. XML as a fully text-based format takes up more processing power and network bandwidth than binary formats would, whereas the battery-powered nature of mobile devices dictates that energy, both in processing and transmitting, be utilized efficiently. This thesis presents the work we have performed to reconcile these two worlds. We present a message transfer service that we have developed to address what we have identified as the three key issues: XML processing at the application level, a more efficient XML serialization format, and the protocol used to transfer messages. Our presentation includes both a high-level architectural view of the whole message transfer service, as well as detailed descriptions of the three new components. These components consist of an API, and an associated data model, for XML processing designed for messaging applications, a binary serialization format for the data model of the API, and a message transfer protocol providing two-way messaging capability with support for client mobility. We also present relevant performance measurements for the service and its components. As a result of this work, we do not consider XML to be inherently incompatible with mobile devices. As the fixed networking world moves toward XML for interoperable data representation, so should the wireless world also do to provide a better-integrated networking infrastructure. However, the problems that XML adoption has touch all of the higher layers of application programming, so instead of concentrating simply on the serialization format we conclude that improvements need to be made in an integrated fashion in all of these layers.
Resumo:
Few-layer graphene films were grown by chemical vapor deposition and transferred onto n-type crystalline silicon wafers to fabricate graphene/n-silicon Schottky barrier solar cells. In order to increase the power conversion efficiency of such cells the graphene films were doped with nitric acid vapor and an antireflection treatment was implemented to reduce the sunlight reflection on the top of the device. The doping process increased the work function of the graphene film and had a beneficial effect on its conductivity. The deposition of a double antireflection coating led to an external quantum efficiency up to 90% across the visible and near infrared region, the highest ever reported for this type of devices. The combined effect of graphene doping and antireflection treatment allowed to reach a power conversion efficiency of 8.5% exceeding the pristine (undoped and uncoated) device performance by a factor of 4. The optical properties of the antireflection coating were found to be not affected by the exposure to nitric acid vapor and to remain stable over time.
Resumo:
Background Although thermal imaging can be a valuable technology in the prevention and management of diabetic foot disease, it is not yet widely used in clinical practice. Technological advancement in infrared imaging increases its application range. The aim was to explore the first steps in the applicability of high-resolution infrared thermal imaging for noninvasive automated detection of signs of diabetic foot disease. Methods The plantar foot surfaces of 15 diabetes patients were imaged with an infrared camera (resolution, 1.2 mm/pixel): 5 patients had no visible signs of foot complications, 5 patients had local complications (e.g., abundant callus or neuropathic ulcer), and 5 patients had difuse complications (e.g., Charcot foot, infected ulcer, or critical ischemia). Foot temperature was calculated as mean temperature across pixels for the whole foot and for specified regions of interest (ROIs). Results No diferences in mean temperature >1.5 °C between the ipsilateral and the contralateral foot were found in patients without complications. In patients with local complications, mean temperatures of the ipsilateral and the contralateral foot were similar, but temperature at the ROI was >2 °C higher compared with the corresponding region in the contralateral foot and to the mean of the whole ipsilateral foot. In patients with difuse complications, mean temperature diferences of >3 °C between ipsilateral and contralateral foot were found. Conclusions With an algorithm based on parameters that can be captured and analyzed with a high-resolution infrared camera and a computer, it is possible to detect signs of diabetic foot disease and to discriminate between no, local, or difuse diabetic foot complications. As such, an intelligent telemedicine monitoring system for noninvasive automated detection of signs of diabetic foot disease is one step closer. Future studies are essential to confirm and extend these promising early findings.
Automatic detection of diabetic foot complications with infrared thermography by asymmetric analysis
Resumo:
Early identification of diabetic foot complications and their precursors is essential in preventing their devastating consequences, such as foot infection and amputation. Frequent, automatic risk assessment by an intelligent telemedicine system might be feasible and cost effective. Infrared thermography is a promising modality for such a system. The temperature differences between corresponding areas on contralateral feet are the clinically significant parameters. This asymmetric analysis is hindered by (1) foot segmentation errors, especially when the foot temperature and the ambient temperature are comparable, and by (2) different shapes and sizes between contralateral feet due to deformities or minor amputations. To circumvent the first problem, we used a color image and a thermal image acquired synchronously. Foot regions, detected in the color image, were rigidly registered to the thermal image. This resulted in 97.8% ± 1.1% sensitivity and 98.4% ± 0.5% specificity over 76 high-risk diabetic patients with manual annotation as a reference. Nonrigid landmark-based registration with Bsplines solved the second problem. Corresponding points in the two feet could be found regardless of the shapes and sizes of the feet. With that, the temperature difference of the left and right feet could be obtained.
Resumo:
Background Patients with diabetic foot disease require frequent screening to prevent complications and may be helped through telemedical home monitoring. Within this context, the goal was to determine the validity and reliability of assessing diabetic foot infection using photographic foot imaging and infrared thermography. Subjects and Methods For 38 patients with diabetes who presented with a foot infection or were admitted to the hospital with a foot-related complication, photographs of the plantar foot surface using a photographic imaging device and temperature data from six plantar regions using an infrared thermometer were obtained. A temperature difference between feet of > 2.2 °C defined a ''hotspot.'' Two independent observers assessed each foot for presence of foot infection, both live (using the Perfusion-Extent-Depth- Infection-Sensation classification) and from photographs 2 and 4 weeks later (for presence of erythema and ulcers). Agreement in diagnosis between live assessment and (the combination of ) photographic assessment and temperature recordings was calculated. Results Diagnosis of infection from photographs was specific (> 85%) but not very sensitive (< 60%). Diagnosis based on hotspots present was sensitive (> 90%) but not very specific (<25%). Diagnosis based on the combination of photographic and temperature assessments was both sensitive (> 60%) and specific (> 79%). Intra-observer agreement between photographic assessments was good (Cohen's j = 0.77 and 0.52 for both observers). Conclusions Diagnosis of foot infection in patients with diabetes seems valid and reliable using photographic imaging in combination with infrared thermography. This supports the intended use of these modalities for the home monitoring of high-risk patients with diabetes to facilitate early diagnosis of signs of foot infection.
Resumo:
The infrared spectra of 2,4-dithiobiuret(DTB), N-deuterated dithiobiuret(DTB-d5) and the laser Raman spectrum of DTB are reported. Normal coordinate treatments of DTB and DTB-d5 have been carried out to aid the assignment of the vibrational frequencies. A trans—cis conformation is favoured for DTB molecule in the solid state.
Resumo:
Of the many factors that govern the settling phenomenon, the flow velocity in the settling tanks can be controlled favorably by fixing suitably designed weirs at the outlets of the tanks. The velocity at the bottom should not dislodge the particles that have already settled. These requirements might be met with by velocities which are controlled to be constant with respect to the depth of flow, or velocities which reduce linearly with increasing depth or velocities that vary inversely with the depth. To achieve these types of velocity control, new proportional weirs have been designed. Very near to the outlet of the tank, over a small length, the flow was found to be turbulent and noncompliant with the expected type of velocity control. This small length of the disturbance may be provided over and above the theoretical settling length of the tank, for efficient sedimentation.
Resumo:
Hydrogen bonding in the highly hindered alcohol 2,4-dimethyl-3-ethyl-3-pentanol has been studied by proton n.m.r. and infrared spectroscopy. This alcohol associates to form a dimer but no higher hydrogen bonded species; hence the monomer–dimer equilibrium can be studied without interference from competing processes. Spectral and thermodynamic properties for the hydrogen bonding are reported.
Resumo:
The nature of coordination in metal monothiocarbamates is shown to depend on the hardness or softness of the metal ton. Thus, the monothiocarbamate ion acts as a monodentate ligand with metal-sulphur bending when the metal ion is a soft acid while it acts as a bidentate ligand when the metal ion is a hard acid; it can exhibit either behaviour when the metal ion is a borderline acid. In dialkyltin and dialkylmonocholorotin complexes, the monothiocarbamate ion acts as a bidentate ligand with strong Sn-S bonding while in trialkyl-or triaryl-tin complexes it acts essentially as a monodentate ligand. Thus, R3Sn(I) seems to be a soft or borderline acid while R2Sn(II) is a hard acid.
Resumo:
We report the material and electrical properties of Erbium Oxide (Er2O3) thin films grown on n-Ge (100) by RF sputtering. The properties of the films are correlated with the processing conditions. The structural characterization reveals that the films annealed at 550 degrees C, has densified as compared to the as-grown ones. Fixed oxide charges and interface charges, both of the order of 10(13)/cm(2) is observed.
Resumo:
Purpose: A computationally efficient algorithm (linear iterative type) based on singular value decomposition (SVD) of the Jacobian has been developed that can be used in rapid dynamic near-infrared (NIR) diffuse optical tomography. Methods: Numerical and experimental studies have been conducted to prove the computational efficacy of this SVD-based algorithm over conventional optical image reconstruction algorithms. Results: These studies indicate that the performance of linear iterative algorithms in terms of contrast recovery (quantitation of optical images) is better compared to nonlinear iterative (conventional) algorithms, provided the initial guess is close to the actual solution. The nonlinear algorithms can provide better quality images compared to the linear iterative type algorithms. Moreover, the analytical and numerical equivalence of the SVD-based algorithm to linear iterative algorithms was also established as a part of this work. It is also demonstrated that the SVD-based image reconstruction typically requires O(NN2) operations per iteration, as contrasted with linear and nonlinear iterative methods that, respectively, requir O(NN3) and O(NN6) operations, with ``NN'' being the number of unknown parameters in the optical image reconstruction procedure. Conclusions: This SVD-based computationally efficient algorithm can make the integration of image reconstruction procedure with the data acquisition feasible, in turn making the rapid dynamic NIR tomography viable in the clinic to continuously monitor hemodynamic changes in the tissue pathophysiology.
Resumo:
High-pressure Raman and mid-infrared spectroscopic studies were carried out on ZrP2O7 to 23.2 and 13 GPa respectively. In the pressure range 0.7-4.3 GPa the lattice mode at 248 cm(-1) disappears, new modes appear around 380 and 1111 cm(-1) and the strong symmetric stretching mode at 476 cm(-1) softens, possibly indicating a subtle phase transition. Above 8 GPa all the modes broaden, and all of the Raman modes disappear beyond 18 GPa. On decompression from the highest pressure, 23.2, to 0 GPa all of the modes reappear but with larger full width at half maximum. Lattice dynamics of the high temperature phase of ZrP2O7 were studied using first principles method and compared with experimental values. (C) 2009 Elsevier Ltd. All rights reserved.