938 resultados para Graft
Resumo:
Resection of musculoskeletal sarcoma can result in large bone defects where regeneration is needed in a quantity far beyond the normal potential of self-healing. In many cases, these defects exhibit a limited intrinsic regenerative potential due to an adjuvant therapeutic regimen, seroma, or infection. Therefore, reconstruction of these defects is still one of the most demanding procedures in orthopaedic surgery. The constraints of common treatment strategies have triggered a need for new therapeutic concepts to design and engineer unparalleled structural and functioning bone grafts. To satisfy the need for long-term repair and good clinical outcome, a paradigm shift is needed from methods to replace tissues with inert medical devices to more biological approaches that focus on the repair and reconstruction of tissue structure and function. It is within this context that the field of bone tissue engineering can offer solutions to be implemented into surgical therapy concepts after resection of bone and soft tissue sarcoma. In this paper we will discuss the implementation of tissue engineering concepts into the clinical field of orthopaedic oncology.
Resumo:
Motivation Shotgun sequence read data derived from xenograft material contains a mixture of reads arising from the host and reads arising from the graft. Classifying the read mixture to separate the two allows for more precise analysis to be performed. Results We present a technique, with an associated tool Xenome, which performs fast, accurate and specific classification of xenograft-derived sequence read data. We have evaluated it on RNA-Seq data from human, mouse and human-in-mouse xenograft datasets.
Resumo:
There is strong current interest in the use of biodegradable scaffolds in combination with bone growth factors as a valuable alternative to the current gold standard autograft in spinal fusion surgery Yong et al. (2013). Here we report on 6- vs 12- month data set evaluating the longitudinal performance of a CaP coated polycaprolactone (PCL) scaffold loaded with recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute within a preclinical ovine thoracic spine. The results of this study demonstrate the efficacy of scaffold-based delivery of rhBMP-2 in promoting higher fusion grades at 6- and 12- months in comparison to the scaffold alone or autograft group within the same time frame. Fusion grades achieved at six months using PCL+rhBMP-2 are not significantly increased at twelve months post surgery.
Resumo:
Four silanes, trimethylchlorosilane (TMCS), dimethyldiethoxylsilane (DMDES), 3-aminopropyltriethoxysilane (APTES) and tetraethoxysilane (TEOS), were adopted to graft layered double hydroxides (LDH) via an induced hydrolysis silylation method (IHS). Fourier transform infrared spectra (FTIR) and 29Si MAS nuclear magnetic resonance spectra (29Si MAS NMR) indicated that APTES and TEOS can be grafted onto LDH surfaces via condensation with hydroxyl groups of LDH, while TMCS and DMDES could only be adsorbed on the LDH surface with a small quantity. A combination of X-ray diffraction patterns (XRD) and 29Si MAS NMR spectra showed that silanes were exclusively present in the external surface and had little influence on the long range order of LDH. The surfactant intercalation experiment indicated that the adsorbed and/or grafted silane could not fix the interlamellar spacing of the LDH. However, they will form crosslink between the particles and affect the further surfactant intercalation in the silylated samples. The replacement of water by ethanol in the tactoids and/or aggregations and the polysiloxane oligomers formed during silylation procedure can dramatically increase the value of BET surface area (SBET) and total pore volumes (Vp) of the products.
Resumo:
Study Design This was a randomised controlled trial in patients with degenerative disc disease (DDD) who underwent instrumented posterolateral lumbar fusion (PLF) surgery. Objective The aim of this study was to assess the efficacy of the bone grafting substitute, silicate-substituted calcium phosphate (SiCaP) compared with bone morphogenetic protein (rhBMP-2) and to evaluate clinical outcomes over a period of two years. Methods Patients undergoing PLF surgery for DDD at a single centre were recruited and randomised to one of two groups; SiCaP (n=9) or rhBMP-2 (n=10). One patient withdrew prior to randomisation and another from the rhBMP-2 group after randomisation. The radiological and clinical outcomes were examined and compared. Fusion was assessed at 12 months with computed tomography (CT) and plain radiographs. Clinical outcomes were evaluated by recording measures of pain, quality of life, disability and neurological status from six weeks to two years postoperatively. Results In the SiCaP and rhBMP-2 groups, fusion was observed in 9/9 and 8/9 patients respectively. Pain and disability scores were reduced and quality of life increased in both groups. Leg pain, disability and satisfaction scores were similar between the groups at each postoperative time point, however, back pain was less at six weeks and quality of life was higher at six months in the SiCaP group than the rhBMP-2 group. Conclusions SiCaP and rhBMP-2 were comparable in terms of achieving successful bone growth and fusion. Both groups similarly alleviated pain and improved quality of life, neurological, satisfaction and return to work outcomes following PLF surgery.
Resumo:
Background Today, finding an ideal biomaterial to treat the large bone defects, delayed unions and non-unions remains a challenge for orthopaedic surgeions and researchers. Several studies have been carried out on the subject of bone regeneration, each having its own advantages. The present study has been designed in vivo to evaluate the effects of cellular auto-transplantation of tail vertebrae on healing of experimental critical bone defect in a dog model. Methods Six indigenous breeds of dog with 32 ± 3.6 kg average weight from both sexes (5 males and 1 female) received bilateral critical-sized ulnar segmental defects. After determining the health condition, divided to 2 groups: The Group I were kept as control I (n = 1) while in Group II (experimental group; n = 5) bioactive bone implants were inserted. The defects were implanted with either autogeneic coccygeal bone grafts in dogs with 3-4 cm diaphyseal defects in the ulna. Defects were stabilized with internal plate fixation, and the control defects were not stabilized. Animals were euthanized at 16 weeks and analyzed by histopathology. Results Histological evaluation of this new bone at sixteen weeks postoperatively revealed primarily lamellar bone, with the formation of new cortices and normal-appearing marrow elements. And also reformation cortical compartment and reconstitution of marrow space were observed at the graft-host interface together with graft resorption and necrosis responses. Finally, our data were consistent with the osteoconducting function of the tail autograft. Conclusions Our results suggested that the tail vertebrae autograft seemed to be a new source of autogenous cortical bone in order to supporting segmental long bone defects in dogs. Furthermore, cellular autotransplantation was found to be a successful replacement for the tail vertebrae allograft bone at 3-4 cm segmental defects in the canine mid- ulna. Clinical application using graft expanders or bone autotransplantation should be used carefully and requires further investigation.
Resumo:
Objectives: To describe longitudinal height, weight, and body mass index changes up to 15 years after childhood liver transplantation. Study design: Retrospective chart review of patients who underwent liver transplant from 1985-2004 was performed. Subjects were age <18 years at transplant, survived ≥5 years, with at least 2 recorded measurements, of which one was ≥5 years post-transplant. Measurements were recorded pre-transplant, 1, 5, 10, and 15 years later. Results: Height and weight data were available in 98 and 104 patients, respectively; 47% were age <2 years at transplant; 58% were Australian, and the rest were from Japan. Height recovery continued for at least 10 years to reach the 26th percentile (Z-score -0.67) 15 years after transplant. Australians had better growth recovery and attained 47th percentile (Z-score -0.06) at 15 years. Weight recovery was most marked in the first year and continued for 15 years even in well-nourished children. Growth impaired and malnourished children at transplant exhibited the best growth, but remained significantly shorter and lighter even 15 years later. No effect of sex or age at transplant was noted on height or weight recovery. Post-transplant factors significantly impact growth recovery and likely caused the dichotomous growth recovery between Australian and Japanese children; 9% (9/98) of patients were overweight on body mass index calculations at 10-15 years but none were obese. Conclusions: After liver transplant, children can expect ongoing height and weight recovery for at least 10-15 years. Growth impairment at transplant and post-transplant care significantly impact long-term growth recovery. Copyright © 2013 Mosby Inc. All rights reserved.
Resumo:
Objective: To review the outcome of acute liver failure (ALF) and the effect of liver transplantation in children in Australia. Methodology: A retrospective review was conducted of all paediatric patients referred with acute liver failure between 1985 and 2000 to the Queensland Liver Transplant Service, a paediatric liver transplant centre based at the Royal Children's Hospital, Brisbane, that is one of three paediatric transplant centres in Australia. Results: Twenty-six patients were referred with ALF. Four patients did not require transplantation and recovered with medical therapy while two were excluded because of irreversible neurological changes and died. Of the 20 patients considered for transplant, three refused for social and/or religious reasons, with 17 patients listed for transplantation. One patient recovered spontaneously and one died before receiving a transplant. There were 15 transplants of which 40% (6/15) were < 2 years old. Sixty-seven per cent (10/15) survived > 1 month after transplantation. Forty per cent (6/15) survived more than 6 months after transplant. There were only four long term survivors after transplant for ALF (27%). Overall, 27% (6/22) of patients referred with ALF survived. Of the 16 patients that died, 44% (7/16) were from neurological causes. Most of these were from cerebral oedema but two patients transplanted for valproate hepatotoxicity died from neurological disease despite good graft function. Conclusions: Irreversible neurological disease remains a major cause of death in children with ALF. We recommend better patient selection and early referral and transfer to a transplant centre before onset of irreversible neurological disease to optimize outcome of children transplanted for ALF.
Resumo:
Post-liver transplant cytomegalovirus (CMV) infection (seroconversion or virus isolation) and CMV disease (infection plus clinical signs and symptoms) were studied in relation to pretransplant recipient and donor serology, age, nutritional status and the effect of paediatric versus adult (reduced size) grafts. Of 70 children receiving 79 transplants, 26 (37%) had evidence of CMV infection, and eight (11.5%) had evidence of CMV disease, four of whom died. The primary infection rate (where the recipients were CMV negative) was 71% with mortality of 7% with most receiving a CMV-positive graft. The active secondary infection rate (reactivation or reinfection, where the recipients were CMV positive) was 60% with mortality of 12.5%. No significant differences in infection on disease rates were found comparing malnourished versus well-nourished patients, or between those who received whole or reduced-size grafts. The high prevalence of CMV infections supports the view that clinical signs alone are inadequate to direct investigations for CMV. Both primary and active secondary CMV infection can result in serious morbidity and mortality in children receiving liver transplants. These data do not support the strategy of providing immunoprophylaxis to seronegative recipients only, at least in paediatric liver transplantation.
Resumo:
Background: Autogenous vein grafting is widely used in regular bypassing procedures. Due to its mismatch with the host artery in both mechanical property and geometry, the graft often over expands under high arterial blood pressure and forms a step-depth where eddy flow develops, thus causing restenosis, fibrous graft wall, etc. External stents, such as sheaths being used to cuff the graft, have been introduced to eliminate these mismatches and increase the patency. Although histological and immunochemical studies have shown some positive effects of the external stent, the mechanical mismatch under the protection of an external stent remains poorly analyzed. Methods: In this study, the jugular veins taken from hypercholesterolemic rabbits were transplanted into the carotid arteries, and non-woven polyglycolic acid (PGA) fabric was used to fabricate the external stents to study the effect of the biodegradable external stent. Eight weeks after the operation, the grafts were harvested to perform mechanical tests and histological examinations. An arc tangent function was suggested to describe the relationship between pressure and cross-sectional area to analyse the compliance of the graft. Results: The results from the mechanical tests indicated that grafts either with or without external stents displayed large compliance in the low-pressure range and were almost inextensible in the high-pressure range. This was very different from the behavior of the arteries or veins in vivo. The data from histological tests showed that, with external stents, collagen fibers were more compact, whilst those in the graft without protection were looser and thicker. No elastic fiber was found in either kind of grafts. Furthermore, grafts without protection were over-expanded which resulted in much bigger cross-sectional areas. Conclusion: The PGA external extent contributes little to the reduction of the mechanical mismatch between the graft and its host artery while remodeling develops. For the geometric mismatch, it reduces the cross-section area, therefore matching with the host artery much better. Although there are some positive effects, conclusively the PGA is not an ideal material for external stent.
Resumo:
Study Design Retrospective review of prospectively collected data. Objectives To analyze intervertebral (IV) fusion after thoracoscopic anterior spinal fusion (TASF) and explore the relationship between fusion scores and key clinical variables. Summary of Background Information TASF provides comparable correction with some advantages over posterior approaches but reported mechanical complications, and their relationship to non-union and graft material is unclear. Similarly, the optimal combination of graft type and implant stiffness for effecting successful radiologic union remains undetermined. Methods A subset of patients from a large single-center series who had TASF for progressive scoliosis underwent low-dose computed tomographic scans 2 years after surgery. The IV fusion mass in the disc space was assessed using the 4-point Sucato scale, where 1 indicates <50% and 4 indicates 100% bony fusion of the disc space. The effects of rod diameter, rod material, graft type, fusion level, and mechanical complications on fusion scores were assessed. Results Forty-three patients with right thoracic major curves (mean age 14.9 years) participated in the study. Mean fusion scores for patient subgroups ranged from 1.0 (IV levels with rod fractures) to 2.2 (4.5-mm rod with allograft), with scores tending to decrease with increasing rod size and stiffness. Graft type (autograft vs. allograft) did not affect fusion scores. Fusion scores were highest in the middle levels of the rod construct (mean 2.52), dropping off by 20% to 30% toward the upper and lower extremities of the rod. IV levels where a rod fractured had lower overall mean fusion scores compared to levels without a fracture. Mean total Scoliosis Research Society (SRS) questionnaire scores were 98.9 from a possible total of 120, indicating a good level of patient satisfaction. Conclusions Results suggest that 100% radiologic fusion of the entire disc space is not necessary for successful clinical outcomes following thoracoscopic anterior selective thoracic fusion.