999 resultados para Free gingival graft


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rational manipulation of mRNA folding free energy allows rheostat control of pneumolysin production by Streptococcus pneumoniae

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Biomateriais, Reabilitação e Biomecânica)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Architectural (bad) smells are design decisions found in software architectures that degrade the ability of systems to evolve. This paper presents an approach to verify that a software architecture is smellfree using the Archery architectural description language. The language provides a core for modelling software architectures and an extension for specifying constraints. The approach consists in precisely specifying architectural smells as constraints, and then verifying that software architectures do not satisfy any of them. The constraint language is based on a propositional modal logic with recursion that includes: a converse operator for relations among architectural concepts, graded modalities for describing the cardinality in such relations, and nominals referencing architectural elements. Four architectural smells illustrate the approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In some regions of Brazil, especially where the water is scarce, drinking water is stored in water storage tanks. This practice gives the consumer the guarantee of available water. The water storage conditions such as the exposure to hot weather when the tanks are on rooftops allow the development of microorganisms and microbial biofilms which can deteriorate the water quality and increase the risk to human health [1,2]. This study describes the filamentous fungi (FF) detected in free water and biofilms in drinking water storage tanks in Recife - Pernambuco, Brazil. Five sampling times in triplicate were performed at two distinct points. Colony-forming units (CFU) of FF fungi were determined with 0.45 μm filtration membranes using peptone glucose rose Bengal agar (PGRBA). From the 30 samples analysed a total of 1136 CFU were obtained. The water biofilms were collected from samplers consisting of polyethylene coupons, previously installed in the reservoirs. These coupons were transferred to PGRBA plates and incubated using with the same conditions described for free FF. For the in situ detection of FF in biofilms the Calcofluor White staining technique was used. This procedure demonstrated FF forming biofilms on the surfaces of the coupons. Brazilian legislation does not define limits for FF in drinking water. However considering the potential risk of fungal contamination, the data obtained in this study will contribute to developing future quantitative and qualitative parameters for the presence of fungi in drinking water distribution systems in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the initial clinical experience of transmyocardial laser revascularization (TMLR) in patients with severe diffuse coronary artery disease. METHODS: Between February, 1998 and February, 1999, 20 patients were submitted to TMLR at the Heart Institute (InCor), University of São Paulo Medical School, Brazil, isolated or in association with conventional coronary artery bypass graft (CABG). All patients had severe diffuse coronary artery disease, with angina functional class III/IV (Canadian Cardiovascular Society score) unresponsive to medical therapy. Fourteen patients were submitted to TMLR as the sole therapy, whereas 6 underwent concomitant CABG. Fifty per cent of the patients had either been previously submitted to a CABG or to a percutaneous transluminal coronary angioplasty (PTCA). Mean age was 60 years, ranging from 45 to 74 years. RESULTS: All patients had three-vessel disease, with normal or mildly impaired left ventricular global function. Follow-up ranged from 1 to 13 months (mean 6.6 months), with no postoperative short or long term mortality. There was significant symptom improvement after the procedure, with 85% of the patients free of angina, and the remaining 15 % of the patients showing improvement in functional class, as well as in exercise tolerance. CONCLUSION: This novel technique can be considered a low risk alternative for a highly selected group of patients not suitable for conventional revascularization procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - To analyze the immediate and late results of mitral valve repair with quadrangular resection of the posterior leaflet without the use of a prosthetic ring annuloplasty. METHODS - Using this technique, 118 patients with mitral valve prolapse who underwent mitral repair from January '84 through December '96 were studied. Age ranged from 30 to 86 (mean = 59.1±11.8) years and 62.7% were males. An associated surgery was performed in 22% of the patients, and coronary artery bypass graft was the most frequently performed surgery (15 patients - 12.7%). In 20 (16.9%) patients other associated techniques of mitral valve repair were used and shortening of elongated chordae tendineae was the most frequent one (6 patients). RESULTS - Immediate mortality was 0.9% (one patient). Long-term rates for thromboembolism, endocarditis, re-operation and death in the late postoperative period were 0.4%, 0.4%, 1.7% and 2.2% patients/year, respectively. The actuarial curve of survival was 83.8±8.6% over 12 years; survival free from re-operation was 91.8±4.3%, free from endocarditis was 99.2±0.8% and free from thromboembolism was 99.2±0.8%. In the late postoperative period, 93.8% of the patients were in functional class 1 (NYHA), with a complete follow-up in 89.7% of the patients. CONCLUSION - Patients with mitral valve prolapse who undergo mitral valve repair using this technique have a satisfactory prognosis over 12 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Ciências da Comunicação (área de especialização em Publicidade e Relações Públicas)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supplementary data associated with this article can be found, in the online version, at: http://dx.doi.org/10.1016/j.electacta.2015.09.169.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pregnancy and postpartum have been associated to several physiological changes;however, empirical evidence was almost exclusively obtained in primiparous women and few studies focus on hormonal changes in men and second-time parents. The main aim of this study is to examine 24-h urinary free cortisol from mid-pregnancy to 3-months postpartum, comparing women/men and first/second-time parents.Methods: Twenty-six women and 22 men (N = 48) were recruited from an antenatal obstetric unit in Porto, Portugal. 24-h urinary free cortisol was measured at the 2nd and 3rd trimester and at 3-months postpartum. Repeated measures analyses of variance were conducted, in order to analyze 24-h urinary free cortisol patterns of change over this period. Gender and parity were included in the analyses as potential modifiers, in order to compare women and men, and first-and second-time parents.Results: An increase from the 2nd to the 3rd trimester (p = .006) and a decrease from the 3rd trimester to 3-months postpartum (p = .005) were reported in all parents’ 24-h urinary free cortisol. The interaction effects for Time * Gender (p = .03) and Time * Parity (p = .02) were found. Women and first-time parents revealed higher levels, while men and second-time parents showed lower 24-h urinary free cortisol levels at the 2nd trimester than at 3-months postpartum.Conclusions: Findings appear to clarify the direction, as well as, the timing, gender and parity extension of 24-h urinary free cortisol changes from mid-pregnancy to 3-months postpartum.The same pattern of change in all parents’ 24-h urinary free cortisol from mid-pregnancy to 3-months postpartum is consistent with the proposed role of hormones in preparation to parenting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências da Saúde

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abdominal Aortic Aneurysms (AAA) haemorhaging is a life-threatening disease. An aneurysm is a permanent swelling of an artery due to a weakness in its wall. Current surgical repair involves opening the chest or abdomen, gaining temporary vascular control of the aorta and suturing a prosthetic graft to the healthy aorta within the aneurysm itself The outcome of this surgical approach is not perfect, and the quality of life after this repair is impaired by postoperative pain, sexual dysfunction, and a lengthy hospital stay resulting in high health costs. All these negative effects are related to the large incision and extensive tissue dissection. Endovascular grafting is an alternative to the standard surgical method. This treatment is a less invasive method of treating aortic aneurysms. It involves a surgical exposure of the common femoral arteries where the stent graft can be inserted through by an over-the-wire technique. All manipulations are controlled from a remote place by the use of a catheter and this technique avoids the need to directly expose the diseased artery through a large incision or an extensive dissection. The proposed design method outlined in this project is to develop the endovascular approach. The main aim is to design an unitary bifurcated stent graft (1 e- bifurcated graft as a single component) to treat these Abdominal Aortic Aneurysms. This includes the delivery system and deployment mechanism necessary to first accurately position the stent graft across the aneurysm sac and also across the iliac bifurcation, and secondly fix the stent graft in position by using expandable metal stents. Thus, excluding the aneurysm from the circulation and therefore preventing rupture. Miniaturisation is a critical aspect of this design, as the smaller the crimped stent graft the easier to guide through the vascular system to the desired location. Biocompatibility is an important aspect. The preferred materials for this prosthesis are to use Shape Memory Alloys for the stent and a multifilament fabric for the graft. A taper design is applied for the geometry as this gives a favourable flow characteristic and reduced wave reflections. Adequate testing of the stent graft to prove its durability and the ease of the method of deployment is a prerequisite. A bench test facility has being designed and build to replicate the cardiovascular system and the disease in question aortic aneurysms at the iliac bifurcation. The testing here shows the feasibility of the proposed delivery system and the durability of the stent graft across the aneurysm sac. Finally, these endovascular treatments offer the economic advantage of short hospital stays or even treatment as an outpatient, as well as elimination of the need for postoperative intensive care The risk of developing an aneurysm increases with age, that is one of the mam reasons to look for less invasive ways of treating aneurysms. Consequently, there is enormous pressure to develop and use these devices rapidly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impending introduction of lead-free solder in the manufacture of electrical and electronic products has presented the electronics industry with many challenges. European manufacturers must transfer from a tin-lead process to a lead-free process by July 2006 as a result of the publication of two directives from the European Parliament. Tin-lead solders have been used for mechanical and electrical connections on printed circuit boards for over fifty years and considerable process knowledge has been accumulated. Extensive literature reviews were conducted on the topic and as a result it was found there are many implications to be considered with the introduction of lead-free solder. One particular question that requires answering is; can lead-free solder be used in existing manufacturing processes? The purpose of this research is to conduct a comparative study of a tin-lead solder and a lead-free solder in two key surface mount technology (SMT) processes. The two SMT processes in question were the stencil printing process and the reflow soldering process. Unreplicated fractional factorial experimental designs were used to carry out the studies. The quality of paste deposition in terms of height and volume were the characteristics of interest in the stencil printing process. The quality of solder joints produced in the reflow soldering experiment was assessed using x-ray and cross sectional analysis. This provided qualitative data that was then uniquely scored and weighted using a method developed during the research. Nested experimental design techniques were then used to analyse the resulting quantitative data. Predictive models were developed that allowed for the optimisation of both processes. Results from both experiments show that solder joints of comparable quality to those produced using tin-lead solder can be produced using lead-free solder in current SMT processes.