966 resultados para Extended access


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report for the Iowa Utilities Board.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Street-based sex workers (SSWs) in Lausanne, Switzerland, are poorly characterised. We set out to quantify potential vulnerability factors in this population and to examine SSW healthcare use and unmet healthcare requirements. METHODS: We conducted a cross-sectional questionnaire-based survey among SSWs working in Lausanne's red light district between 1 February and 31 July 2010, examining SSW socio-demographic characteristics and factors related to their healthcare. RESULTS: We interviewed 50 SSWs (76% of those approached). A fifth conducted their interviews in French, the official language in Lausanne. 48 participants (96%) were migrants, of whom 33/48 (69%) held no residence permit. 22/50 (44%) had been educated beyond obligatory schooling. 28/50 (56%) had no health insurance. 18/50 (36%) had been victims of physical violence. While 36/50 (72%) had seen a doctor during the preceding 12 months, only 15/50 (30%) were aware of a free clinic for individuals without health insurance. Those unaware of free services consulted emergency departments or doctors outside Switzerland. Gynaecology, primary healthcare and dental services were most often listed as needed. Two individuals (of 50, 4%) disclosed positive HIV status; of the others, 24/48 (50%) had never had an HIV test. CONCLUSIONS: This vulnerable population comprises SSWs who, whether through mobility, insufficient education or language barriers, are unaware of services they are entitled to. With half the participants reporting no HIV testing, there is a need to enhance awareness of available facilities as well as to increase provision and uptake of HIV testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The intraoperative quality assessment of the arteriovenous fistula for hemodialysis is an essential process to limit early failure due to technical problems or inadequate vascular quality. This step is not clearly defined in the literature with no recommendations. METHODS: We selected published articles related to the topic of intraoperative quality control of the vascular access for hemodialysis. RESULTS: The intraoperative blood flow measurement greater than 120 ml/min in autologous fistula and less than 320 ml/min in arteriovenous graft was described as predictive factors for early failure. CONCLUSIONS: The blood flow measurement should be performed after the confection of the anastomosis. When blood flow is limited, fistulography is an essential step to assess patency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A radiative equation of the Cattaneo–Vernotte type is derived from information theory and the radiative transfer equation. The equation thus derived is a radiative analog of the equation that is used for the description of hyperbolic heat conduction. It is shown, without recourse to any phenomenological assumption, that radiative transfer may be included in a natural way in the framework of extendedirreversible thermodynamics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the benefits and experimental feasibility of approaches enabling the shift from short (1.7kDa on average) peptides in bottom-up proteomics to about twice longer (~3.2kDa on average) peptides in the so-called extended bottom-up proteomics. Candida albicans secreted aspartic protease Sap9 has been selected for evaluation as an extended bottom-up proteomic-grade enzyme due to its suggested dibasic cleavage specificity and ease of production. We report the extensive characterization of Sap9 specificity and selectivity revealing that protein cleavage by Sap9 most often occurs in the vicinity of proximal basic amino acids, and in select cases also at basic and hydrophobic residues. Sap9 is found to cleave a large variety of proteins in a relatively short, ~1h, period of time and it is efficient in a broad pH range, including slightly acidic, e. g., pH5.5, conditions. Importantly, the resulting peptide mixtures contain representative peptides primarily in the target 3-7kDa range. The utility and advantages of this enzyme in routine analysis of protein mixtures are demonstrated and the limitations are discussed. Overall, Sap9 has a potential to become an enzyme of choice in an extended bottom-up proteomics, which is technically ready to complement the traditional bottom-up proteomics for improved targeted protein structural analysis and expanded proteome coverage. BIOLOGICAL SIGNIFICANCE: Advances in biological applications of mass spectrometry-based bottom-up proteomics are oftentimes limited by the extreme complexity of biological samples, e.g., proteomes or protein complexes. One of the reasons for it is in the complexity of the mixtures of enzymatically (most often using trypsin) produced short (<3kDa) peptides, which may exceed the analytical capabilities of liquid chromatography and mass spectrometry. Information on localization of protein modifications may also be affected by the small size of typically produced peptides. On the other hand, advances in high-resolution mass spectrometry and liquid chromatography have created an intriguing opportunity of improving proteome analysis by gradually increasing the size of enzymatically-derived peptides in MS-based bottom-up proteomics. Bioinformatics has already confirmed the envisioned advantages of such approach. The remaining bottle-neck is an enzyme that could produce longer peptides. Here, we report on the characterization of a possible candidate enzyme, Sap9, which may be considered for producing longer, e.g., 3-7kDa, peptides and lead to a development of extended bottom-up proteomics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Devices for venous cannulation have seen significant progress over time: the original, rigid steel cannulas have evolved toward flexible plastic cannulas with wire support that prevents kinking, very thin walled wire wound cannulas allowing for percutaneous application, and all sorts of combinations. In contrast to all these rectilinear venous cannula designs, which present the same cross-sectional area over their entire intravascular path, the smartcanula concept of "collapsed insertion and expansion in situ" is the logical next step for venous access. Automatically adjusting cross-sectional area up to a pre-determined diameter or the vessel lumen provides optimal flow and ease of use for both, insertion and removal. Smartcanula performance was assessed in a small series of patients (76 +/- 17 kg) undergoing redo procedures. The calculated target pump flow (2.4 L/min/m2) was 4.42 +/- 61 L/ min. Mean pump flow achieved during cardiopulmonary bypass was 4.84 +/- 87 L/min or 110% of the target. Reduced atrial chatter, kink resistance in situ, and improved blood drainage despite smaller access orifice size, are the most striking advantages of this new device. The benefits of smart cannulation are obvious in remote cannulation for limited access cardiac surgery, but there are many other cannula applications where space is an issue, and that is where smart cannulation is most effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary objective of the Fourth Assessment is to evaluate the level of progress in the deployment of high-speed Internet technologies in the State of Iowa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the recent advances in structural analysis of monoclonal antibodies with bottom-up, middle-down, and top-down mass spectrometry (MS), further improvements in analysis accuracy, depth, and speed are needed. The remaining challenges include quantitatively accurate assignment of post-translational modifications, reduction of artifacts introduced during sample preparation, increased sequence coverage per liquid chromatography (LC) MS experiment, and ability to extend the detailed characterization to simple antibody cocktails and more complex antibody mixtures. Here, we evaluate the recently introduced extended bottom-up proteomics (eBUP) approach based on proteolysis with secreted aspartic protease 9, Sap9, for analysis of monoclonal antibodies. Key findings of the Sap9-based proteomics analysis of a single antibody include: (i) extensive antibody sequence coverage with up to 100% for the light chain and up to 99-100% for the heavy chain in a single LC-MS run; (ii) connectivity of complementarity-determining regions (CDRs) via Sap9-produced large proteolytic peptides (3.4 kDa on average) containing up to two CDRs per peptide; (iii) reduced artifact introduction (e. g., deamidation) during proteolysis with Sap9 compared to conventional bottom-up proteomics workflows. The analysis of a mixture of six antibodies via Sap9-based eBUP produced comparable results. Due to the reasons specified above, Sap9-produced proteolytic peptides improve the identification confidence of antibodies from the mixtures compared to conventional bottom-up proteomics dealing with shorter proteolytic peptides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: With increasing computer power, simulating the dynamics of complex systems in chemistry and biology is becoming increasingly routine. The modelling of individual reactions in (bio)chemical systems involves a large number of random events that can be simulated by the stochastic simulation algorithm (SSA). The key quantity is the step size, or waiting time, τ, whose value inversely depends on the size of the propensities of the different channel reactions and which needs to be re-evaluated after every firing event. Such a discrete event simulation may be extremely expensive, in particular for stiff systems where τ can be very short due to the fast kinetics of some of the channel reactions. Several alternative methods have been put forward to increase the integration step size. The so-called τ-leap approach takes a larger step size by allowing all the reactions to fire, from a Poisson or Binomial distribution, within that step. Although the expected value for the different species in the reactive system is maintained with respect to more precise methods, the variance at steady state can suffer from large errors as τ grows. Results: In this paper we extend Poisson τ-leap methods to a general class of Runge-Kutta (RK) τ-leap methods. We show that with the proper selection of the coefficients, the variance of the extended τ-leap can be well-behaved, leading to significantly larger step sizes.Conclusions: The benefit of adapting the extended method to the use of RK frameworks is clear in terms of speed of calculation, as the number of evaluations of the Poisson distribution is still one set per time step, as in the original τ-leap method. The approach paves the way to explore new multiscale methods to simulate (bio)chemical systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The analysis of the promoter sequence of genes with similar expression patterns isa basic tool to annotate common regulatory elements. Multiple sequence alignments are on thebasis of most comparative approaches. The characterization of regulatory regions from coexpressedgenes at the sequence level, however, does not yield satisfactory results in manyoccasions as promoter regions of genes sharing similar expression programs often do not shownucleotide sequence conservation.Results: In a recent approach to circumvent this limitation, we proposed to align the maps ofpredicted transcription factors (referred as TF-maps) instead of the nucleotide sequence of tworelated promoters, taking into account the label of the corresponding factor and the position in theprimary sequence. We have now extended the basic algorithm to permit multiple promotercomparisons using the progressive alignment paradigm. In addition, non-collinear conservationblocks might now be identified in the resulting alignments. We have optimized the parameters ofthe algorithm in a small, but well-characterized collection of human-mouse-chicken-zebrafishorthologous gene promoters.Conclusion: Results in this dataset indicate that TF-map alignments are able to detect high-levelregulatory conservation at the promoter and the 3'UTR gene regions, which cannot be detectedby the typical sequence alignments. Three particular examples are introduced here to illustrate thepower of the multiple TF-map alignments to characterize conserved regulatory elements inabsence of sequence similarity. We consider this kind of approach can be extremely useful in thefuture to annotate potential transcription factor binding sites on sets of co-regulated genes fromhigh-throughput expression experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supported by IEEE 802.15.4 standardization activities, embedded networks have been gaining popularity in recent years. The focus of this paper is to quantify the behavior of key networking metrics of IEEE 802.15.4 beacon-enabled nodes under typical operating conditions, with the inclusion of packet retransmissions. We corrected and extended previous analyses by scrutinizing the assumptions on which the prevalent Markovian modeling is generally based. By means of a comparative study, we singled out which of the assumptions impact each of the performance metrics (throughput, delay, power consumption, collision probability, and packet-discard probability). In particular, we showed that - unlike what is usually assumed - the probability that a node senses the channel busy is not constant for all the stages of the backoff procedure and that these differences have a noticeable impact on backoff delay, packet-discard probability, and power consumption. Similarly, we showed that - again contrary to common assumption - the probability of obtaining transmission access to the channel depends on the number of nodes that is simultaneously sensing it. We evidenced that ignoring this dependence has a significant impact on the calculated values of throughput and collision probability. Circumventing these and other assumptions, we rigorously characterize, through a semianalytical approach, the key metrics in a beacon-enabled IEEE 802.15.4 system with retransmissions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèseObjectif: le remplacement valvulaire aortique par voie transcathétère est, actuellement, une méthode fiable indiquée pour des patients à haut risque porteurs d'une sténose valvulaire aortique. La voie transfémorale est utilisable seulement en cas d'absence de maladie vasculaire et la voie transapicale est contrindiquée en cas de dysfonction pulmonaire chronique sévère. Une alternative pour ne pas passer a travers l'espace pleural serait par voie sous- xiphoïdienne et trans-septale à travers le ventricule droit.Méthode: une expérience animale a été amené au laboratoire de recherche du CHUV. Cinq cochons (poids : 52.3±10.9 kg) ont été endormi et, sous anesthésie générale, le ventricule droit a été préparé a travers un accès sous- xiphoïdien. Ensuite, sous guide fluoroscopique et avec l'utilisation d'une échocardiographie intracardiaque, un accès trans-septal a été crée entre le ventricule droit et le ventricule gauche en utilisant des dilatateur de diamètre croissant (de 8F à 26F). Par la suite, une valve stentée crée dans le laboratoire en utilisant un stent en nitinol et du péricarde a été chargé dans une cartouche et introduite dans le ventricule gauche à travers un introducteur trans-septal. Enfin, la valve a été amené dans la chambre de chasse du ventricule gauche et ensuite dans la racine aortique et puis déployé au bon endroit. Quand le système a été retiré, le septum ventriculaire a pu être réparé par mise en place d'un système d'occlusion septal Amplazer. Trente minutes après la procédure, les animaux ont été sacrifié et le coeur a été analysé pour étudier le positionnement da la valve stentée, l'efficacité de la fermeture du septum inter-ventriculaire et la fermeture de la paroi du ventricule droit.Résultat : les cinq cochon ont tous eu un parfait positionnement et pose de la prothèse en position aortique au premier essai (efficacité 100%). Les procédures ont duré, moyennement, 49±4 minutes et la progressive dilatation de l'accès trans-septale à donné lieu à une communication inter-ventriculaire mesurable après dilatation avec du 18F et plus. Toutes les valves stentées ont été déployées au bon endroit avec un bon résultat du fonctionnement des valves prothétiques et absence d'insuffisance para prothétique. Pendant les procédures, des battement prématurés ainsi que des épisodes isolées de tachycardie supra ventriculaire ont été détectés. Par contre, il n'y a pas eu de bloc atrio-ventriculaire. Les pertes sanguines pendant les procédures étaient de 280±10mL, et les systèmes d'occlusion Amplatzer étaient tous bien déployés sans shunts inter-ventriculaires résiduels.Conclusion: la technique d'introduction de valve stentées par voie extrapleural (trans-ventriculaire et trans-septale) est techniquement possible et elle jette les bases pour le remplacement valvulaire aortique trans-ventriculaire sous anesthésie locale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Port-a-Cath© (PAC) are totally implantable devices that offer an easy and long term access to venous circulation. They have been extensively used for intravenous therapy administration and are particularly well suited for chemotherapy in oncologic patients. Previous comparative studies have shown that these devices have the lowest catheter-related bloodstream infection rates among all intravascular access systems. However, bloodstream infection (BSI) still remains a major issue of port use and epidemiology data for PAC-associated BSI (PABSI) rates differ strongly depending on studies. Also, current literature about PABSI risk factors is scarce and sometimes controversial. Such heterogeneity may depend on type of studied population and local factors. Therefore, the aim of this study was to describe local epidemiology and risk factors for PABSI in adult patients in our tertiary- care university hospital. We conducted a retrospective cohort study in order to describe local epidemiology. We also performed a nested case-control study to identify local risk factors of PABSI. We analyzed medical files of adult patients who had a PAC implanted between January 1st, 2008 and December 31st, 2009 and looked for PABSI occurrence before May 1st, 2011 to define cases. Thirty nine PABSI occurred in this population with an attack rate of 5.8%. We estimated an incidence rate of 0.08/1000 PAC-days using the case-control study. PABSI causative agents were mainly Gram positive cocci (62%). We identified three predictive factors of PABSI by multivariate statistical analysis: neutropenia on outcome date (Odds Ratio [OR]: 4.05; 95% confidence interval [CI]:1.05- 15.66; p=0.042), diabetes (OR: 11.53; 95% CI: 1.07-124.70; p=0.044) and having another infection than PABSI on outcome date (OR: 6.35; 95% CI: 1.50-26.86; p=0.012). Patients suffering from acute or renal failure (OR: 4.26; 95% CI: 0.94-19.21; p=0.059) or wearing another invasive device (OR: 2.99; 95%CI:0.96-9.31; p=0.059) did not have a statistically increased risk for developing a PABSI according to classical threshold (p<0.05) but nevertheless remained close to significance. Our study demonstrated that local epidemiology and microbiology of PABSI in our institution was similar to previous reports. A larger prospective study is required to confirm our results or to test preventive measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To analyze outcomes after right portal vein embolization extended to segment IV (right PVE + IV) before extended right hepatectomy, including liver hypertrophy, resection rates, and complications after embolization and resection, and to assess differences in outcomes with two different particulate embolic agents. MATERIALS AND METHODS: Between 1998 and 2004, transhepatic ipsilateral right PVE + IV with particles and coils was performed in 44 patients with malignant hepatobiliary disease, including metastases (n = 24), biliary cancer (n = 14), and hepatocellular carcinoma (n = 6). Right PVE + IV was considered if the future liver remnant (FLR; segments II/III with or without I) was less than 25% of the total estimated liver volume (TELV). Tris-acryl microspheres (100-700 microm; n = 21) or polyvinyl alcohol (PVA) particles (355-1,000 microm; n = 23) were administered in a stepwise fashion. Smaller particles were used to occlude distal branches, followed by larger particles to occlude proximal branches until near-complete stasis. Coils were then placed in secondary portal branches. Computed tomographic volumetry was performed before and 3-4 weeks after right PVE + IV to assess FLR hypertrophy. Liver volumes and postembolization and postoperative outcomes were measured. RESULTS: After right PVE + IV with PVA particles, FLR volume increased 45.5% +/- 40.9% and FLR/TELV ratio increased 6.9% +/- 5.6%. After right PVE + IV with tris-acryl microspheres, FLR volume increased 69.0% +/- 30.7% and FLR/TELV ratio increased 9.7% +/- 3.3%. Differences in FLR volume (P = .0011), FLR/TELV ratio (P = .027), and resection rates (P = .02) were statistically significant. Seventy-one percent of patients underwent extended right hepatectomy (86% after receiving tris-acryl microspheres, 57% after receiving PVA). Thirteen patients (29%) did not undergo resection (extrahepatic spread [n = 9], inadequate hypertrophy [n = 3], other reasons [n = 1]). No patient developed postembolization syndrome or progressive liver insufficiency after embolization or resection. One death after resection occurred as a result of sepsis and hemorrhage. Median hospital stays were 1 day after right PVE + IV and 7 days after resection. CONCLUSION: Transhepatic ipsilateral right PVE + IV with use of particles and coils is a safe, effective method for inducing contralateral hypertrophy before extended right hepatectomy. Embolization with small spherical particles provides improved hypertrophy and resection rates compared with larger, nonspherical particles.