874 resultados para Determination of law


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The European Space Agency Soil Moisture andOcean Salinity (SMOS) mission aims at obtaining global maps ofsoil moisture and sea surface salinity from space for large-scale andclimatic studies. It uses an L-band (1400–1427 MHz) MicrowaveInterferometric Radiometer by Aperture Synthesis to measurebrightness temperature of the earth’s surface at horizontal andvertical polarizations ( h and v). These two parameters will beused together to retrieve the geophysical parameters. The retrievalof salinity is a complex process that requires the knowledge ofother environmental information and an accurate processing ofthe radiometer measurements. Here, we present recent resultsobtained from several studies and field experiments that were partof the SMOS mission, and highlight the issues still to be solved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sensitive and specific methods based on gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) for the determination of levels of citalopram, desmethylcitalopram and didesmethylcitalopram in the plasma of patients treated with citalopram are presented, as well as a GC-MS procedure for the assay of the citalopram propionic acid derivative. After addition of a separate internal standard for each drug, liquid-solvent extraction is used to separate the basic compounds from the acid compounds. The demethylated amines are derivatized with trifluoroacetic anhydride, and the acid metabolite with methyl iodide. GC-MS is performed in the electron impact mode, as mass spectrometry by the (positive-ion) chemical ionization mode (methane and ammonia) appeared to be unsuitable. The limits of quantification were 1 ng/ml for citalopram and desmethylcitalopram and 2 ng/ml for the other metabolites. The correlation coefficients for the calibration curves (range 10-500 ng/ml) were > or = 0.999 for all compounds, whether determined by GC or GC-MS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Volumetric soil water content (theta) can be evaluated in the field by direct or indirect methods. Among the direct, the gravimetric method is regarded as highly reliable and thus often preferred. Its main disadvantages are that sampling and laboratory procedures are labor intensive, and that the method is destructive, which makes resampling of a same point impossible. Recently, the time domain reflectometry (TDR) technique has become a widely used indirect, non-destructive method to evaluate theta. In this study, evaluations of the apparent dielectric number of soils (epsilon) and samplings for the gravimetrical determination of the volumetric soil water content (thetaGrav) were carried out at four sites of a Xanthic Ferralsol in Manaus - Brazil. With the obtained epsilon values, theta was estimated using empirical equations (thetaTDR), and compared with thetaGrav derived from disturbed and undisturbed samples. The main objective of this study was the comparison of thetaTDR estimates of horizontally as well as vertically inserted probes with the thetaGrav values determined by disturbed and undisturbed samples. Results showed that thetaTDR estimates of vertically inserted probes and the average of horizontally measured layers were only slightly and insignificantly different. However, significant differences were found between the thetaTDR estimates of different equations and between disturbed and undisturbed samples in the thetaGrav determinations. The use of the theoretical Knight et al. model, which permits an evaluation of the soil volume assessed by TDR probes, is also discussed. It was concluded that the TDR technique, when properly calibrated, permits in situ, nondestructive measurements of q in Xanthic Ferralsols of similar accuracy as the gravimetric method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spatial resolution is a key parameter of all remote sensing satellites and platforms. The nominal spatial resolution of satellites is a well-known characteristic because it is directly related to the area in ground that represents a pixel in the detector. Nevertheless, in practice, the actual resolution of a specific image obtained from a satellite is difficult to know precisely because it depends on many other factors such as atmospheric conditions. However, if one has two or more images of the same region, it is possible to compare their relative resolutions. In this paper, a wavelet-decomposition-based method for the determination of the relative resolution between two remotely sensed images of the same area is proposed. The method can be applied to panchromatic, multispectral, and mixed (one panchromatic and one multispectral) images. As an example, the method was applied to compute the relative resolution between SPOT-3, Landsat-5, and Landsat-7 panchromatic and multispectral images taken under similar as well as under very different conditions. On the other hand, if the true absolute resolution of one of the images of the pair is known, the resolution of the other can be computed. Thus, in the last part of this paper, a spatial calibrator that is designed and constructed to help compute the absolute resolution of a single remotely sensed image is described, and an example of its use is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Urinary steroid profiling is used in doping controls to detect testosterone abuse. A testosterone over epitestosterone (T/E) ratio exceeding 4.0 is considered as suspicious of testosterone administration, irrespectively of individual heterogeneous factors such as the athlete's ethnicity. A deletion polymorphism in the UGT2B17 gene was demonstrated to account for a significant part of the inter-individual variability in the T/E between Caucasians and Asians. However, the anti-doping strategy includes the determination of carbon isotope ratio on androgen metabolites which has been demonstrated to be reliable for the direct detection of testosterone misuse. Herein, we examined the profiles and the variability in the 13C/12Cratios of urinary steroids in a widely heterogeneous cohort of professional soccer players residing in different world countries (Argentina, Italy, Japan, South-Africa, Switzerland and Uganda). Aim: The determination of threshold values based on genotype information and diet specific of the ethnicity is expected to enhance significantly the detection of testosterone misuse. Methods: The steroid profile of 57 Africans, 32 Asians, 50 Caucasians and 32 Hispanics was determined by gas chromatography-mass spectrometry. The carbon isotope ratio of selected androgens in urine specimens were determined by means of gas chromatography/combustion/isotope ratio mass spectrometry (GC-C-IRMS). Results: Significant differences have been observed between all ethnic groups. After estimation of the prevalence of the UGT2B17 deletion/deletion genotype (African:22%; Asian:81%; Caucasian:10%; Hispanic:7%), ethnicspecific thresholds were developed for a specificity of 99% for the T/E (African:5.6; Asian:3.8; Caucasian:5.7; Hispanic:5.8). Italian and Swiss populations recorded an enrichment in 13C of the urinary steroids with respect to the other groups, thereby supporting consumption of a relatively larger proportion of C3 plants in their diet. Noteworthy, detection criteria based on the difference in the carbon isotope ratio of androsterone and pregnanediol for each population were well below the established threshold value for positive cases. Conclusion: These profiling results demonstrate that a unique and nonspecific threshold to evidence testosterone misuse is not fit for purpose. In addition, the carbon isotopic ratio from these different diet groups highlight the importance to adapt the criteria for increasing the sensitivity in the detection of exogenous testosterone. In conclusion, it may be emphasized that combining the use of isotope ratio mass spectrometry including refined interpretation criteria for positivity and the subject-based profiling of steroids will most probably improve the efficiency of the confirmatory test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have devised a program that allows computation of the power of F-test, and hence determination of appropriate sample and subsample sizes, in the context of the one-way hierarchical analysis of variance with fixed effects. The power at a fixed alternative is an increasing function of the sample size and of the subsample size. The program makes it easy to obtain the power of F-test for a range of values of sample and subsample sizes, and therefore the appropriate sizes based on a desired power. The program can be used for the 'ordinary' case of the one-way analysis of variance, as well as for hierarchical analysis of variance with two stages of sampling. Examples are given of the practical use of the program.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Variables measured during static and dynamic pupillometry were factor-analyzed. Following factors were obtained regardless whether investigations were carried out in normals or in psychiatric patients: A static factor, a dynamic factor, a stimulus-specific factor and a restitution-dependent factor. Evaluation of reliability in normals demonstrated a high reliability for the static variables of pupillometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of InxAl12xAs samples (0.51,x,0.55) coherently grown on InP was studied in order to measure the band-gap energy of the lattice matched composition. As the substrate is opaque to the relevant photon energies, a method is developed to calculate the optical absorption coefficient from the photoluminescence excitation spectra. The effect of strain on the band-gap energy has been taken into account. For x50.532, at 14 K we have obtained Eg05154966 meV. © 1997 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for determining soil hydraulic properties of a weathered tropical soil (Oxisol) using a medium-sized column with undisturbed soil is presented. The method was used to determine fitting parameters of the water retention curve and hydraulic conductivity functions of a soil column in support of a pesticide leaching study. The soil column was extracted from a continuously-used research plot in Central Oahu (Hawaii, USA) and its internal structure was examined by computed tomography. The experiment was based on tension infiltration into the soil column with free outflow at the lower end. Water flow through the soil core was mathematically modeled using a computer code that numerically solves the one-dimensional Richards equation. Measured soil hydraulic parameters were used for direct simulation, and the retention and soil hydraulic parameters were estimated by inverse modeling. The inverse modeling produced very good agreement between model outputs and measured flux and pressure head data for the relatively homogeneous column. The moisture content at a given pressure from the retention curve measured directly in small soil samples was lower than that obtained through parameter optimization based on experiments using a medium-sized undisturbed soil column.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study proposes a method of direct and simultaneous determination of the amount of Ca2+ and Mg2+ present in soil extracts using a Calcium Ion-Selective Electrode and by Complexometric Titration (ISE-CT). The results were compared to those obtained by conventional analytical techniques of Complexometric Titration (CT) and Flame Atomic Absorption Spectrometry (FAAS). There were no significant differences in the determination of Ca2+ and Mg2+ in comparison with CT and FAAS, at a 95 % confidence level. Additionally, results of this method were more precise and accurate than of the Interlaboratorial Control (IC).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A two stage sampling strategy is necessary in order to optimize the study of distribution of pollution in soils and groundwater. First, detailed sampling from a limited area coupled with statistical analysis of the data are used to determine the microvariability of the parameter(s). The results from this detailed analysis are then used to calculate the optimal spacing between samples for the larger scale study. This two stage sampling strategy can result in significant financial savings during subsequent soil or groundwater remediation. This combined sampling and statistical analysis approach is illustrated with an example from a heavy metal contaminated site.