952 resultados para Adulterated samples
Resumo:
Polyacrylamide gel electrophoresis, SDS-PAGE system, was adjusted to detect the presence of additional whey in dairy beverages distributed in a Brazilian Government School Meals Program. Aqueous solutions of samples in 8 M urea were submitted to a polyacrylamide gel gradient (10% to 18%). Gel scans from electrophoresis patterns of previously adulterated milk samples showed that caseins peak areas decreased while peak areas of beta -lactoglobulin plus alpha -lactalbumin increased as the percentage of raw milk powder replaced by whey powder increased. The relative densitometer areas of caseins or beta -lactoglobulin plus alpha -lactalbumin plotted against the percentage of whey added to the raw milk showed a linear correlation coefficient square higher than 0.97. The caseins plot was used to determine the percentage of additional whey in 116 dairy beverages, chocolate or coffee flavor. Considering that the lowest relative caseins concentration found in commercial milk powder samples by the present method was 72%, the dairy beverages containing caseins percentages equal to or higher than this value were considered free of additional whey. Based on this criterion, about 49% of the coffee-flavor dairy beverages and 29% of the chocolate-flavor beverages, among all the samples analyzed were adulterated with whey protein to reach the total protein contents specified on their labels. The present method showed a sensitivity of 5% to additional whey.
Resumo:
Milk products such as cheeses may be contaminated by aflatoxin M1 when dairy cattle have consumed feeds contaminated with aflatoxin B1. Samples of "Minas" cheeses (fresh, canastra and standard) were collected by the Inspection Service in the Mercado Central in Belo Horizonte city, Minas Gerais - Brazil. A purified extract was obtained by extraction with dichloromethane followed by a washing with n-hexane and immunoaffinity column purification. The quantification of aflatoxin M1 was done by high performance liquid chromatography (HPLC) using a fluorescence detector. Recoveries were about 75%. In 56 of the 75 samples (74.7%), the presence of aflatoxin M1 was detected in concentrations ranging between 0.02 and 6.92ng/g of cheese. In the positive cases ( > or = 0.02ng/g) the mean contamination level of aflatoxin M1 was 0.08ng/g in fresh cheese, 0.36ng/g in canastra cheese and 0.62ng/g in standard cheese. No aflatoxin M1 maximum tolerance level in cheese has been established in Brazil.
Resumo:
The distribution of the aflatoxin contamination was studied among four maize fractions, separated according to Brazilian grading rules for maize. The fraction that contained fermented, moldy, heated and sprouted grains normally had the highest levels of aflatoxin. However, the fraction contribution to the whole sample contamination level took into account the contamination fraction level and its weight to the whole sample. Considering this, the fraction that contained insect damaged, hollow, up to ¼ fermented and grains damaged by other causes was normally the fraction responsible for the total contamination level in the samples. Nevertheless, the fraction contributions were variable from sample to sample. Therefore, in conclusion, it was not possible to establish a standard behavior for grain fraction-type contribution for different maize lots. The Brazilian grading by qualitative types applied to samples did not show statistic correlation with aflatoxin contamination levels (P<0.05). Two type-1 samples (the best quality type) presented contamination of 380 and 146ng/g. The number of samples with contamination levels above those allowed by Brazilian law (20ng/g) was the same for qualitative types 2, 3, and BS (Below Standard).
Resumo:
The control and monitoring of radioactive elements in foodstuffs is fundamental for human health maintenance. This work presents procedures to measure radioactivity levels in powdered milk samples and also a brief discussion of radionuclide transference from the environment to mankind. The measurements were performed utilizing a high-resolution gamma-ray spectrometer using an HPGe detector. The results allowed the quantification of 40K, 137Cs and 208Tl radionuclides. For 40K the average activity was 482 ± 37 Bq/kg and for 137Cs and 208Tl the lower level of detection was, respectively, 3.7 ± 1.1 and 0.5 ± 0.2 (Bq/kg). The results obtained for the milk samples were compared to data found in the literature and to the limits established by the Brazilian National Commission of Nuclear Energy (CNEN) to assure its safety to human consuption.
Resumo:
The increasing presence of products derived from genetically modified (GM) plants in human and animal diets has led to the development of detection methods to distinguish biotechnology-derived foods from conventional ones. The conventional and real-time PCR have been used, respectively, to detect and quantify GM residues in highly processed foods. DNA extraction is a critical step during the analysis process. Some factors such as DNA degradation, matrix effects, and the presence of PCR inhibitors imply that a detection or quantification limit, established for a given method, is restricted to a matrix used during validation and cannot be projected to any other matrix outside the scope of the method. In Brazil, sausage samples were the main class of processed products in which Roundup Ready® (RR) soybean residues were detected. Thus, the validation of methodologies for the detection and quantification of those residues is absolutely necessary. Sausage samples were submitted to two different methods of DNA extraction: modified Wizard and the CTAB method. The yield and quality were compared for both methods. DNA samples were analyzed by conventional and real-time PCR for the detection and quantification of Roundup Ready® soybean in the samples. At least 200 ng of total sausage DNA was necessary for a reliable quantification. Reactions containing DNA amounts below this value led to large variations on the expected GM percentage value. In conventional PCR, the detection limit varied from 1.0 to 500 ng, depending on the GM soybean content in the sample. The precision, performance, and linearity were relatively high indicating that the method used for analysis was satisfactory.
Resumo:
The Graphite furnace atomic absorption spectrometry (GF AAS) was the technique chosen by the inorganic contamination laboratory (INCQ/ FIOCRUZ) to be validated and applied in routine analysis for arsenic detection and quantification. The selectivity, linearity, sensibility, detection, and quantification limits besides accuracy and precision parameters were studied and optimized under Stabilized Temperature Platform Furnace (STPF) conditions. The limit of detection obtained was 0.13 µg.L-1 and the limit of quantification was 1.04 µg.L-1, with an average precision, for total arsenic, less than 15% and an accuracy of 96%. To quantify the chemical species As(III) and As(V), an ion-exchange resin (Dowex 1X8, Cl- form) was used and the physical-chemical parameters were optimized resulting in a recuperation of 98% of As(III) and of 90% of As(V). The method was applied to groundwater, mineral water, and hemodialysis purified water samples. All results obtained were lower than the maximum limit values established by the legal Brazilian regulations, in effect, 50, 10, and 5 µg.L-1 para As total, As(III) e As(V), respectively. All results were statistically evaluated.
Resumo:
Bee pollen moisture value is one of the quality parameters for this product. Some countries such as Argentina, Brazil, Bulgaria, Poland and Switzerland have bee pollen regulations on quality parameters, but these are not clear regarding which method should be used for moisture determination. The aim of this paper was to compare six methods of moisture determination in dried bee pollen samples. The methods were: conventional oven at 100 °C, vacuum oven at 70 °C, desiccator with sulfuric acid, drying out process with infrared light at 85 °C, lyophilization and Karl Fisher's method. Based on the results, the best methods for moisture determination of bee pollen were the drying process with infrared and the lyophilization, since these have shown lower moisture values.
Resumo:
Coffee is one of the most appreciated drinks in the world. Coffee ground is obtained from the fruit of a small plant that belongs to the genus Coffea. Coffea arabica and Coffea canephora robusta are the two most commercially important species. They are more commonly known as arabica and robusta, respectively. Two-thirds of Coffea arabica plants are grown in South and Central America, and Eastern Africa - the place of origin for this coffee species. Contamination by microorganisms has been a major matter affecting coffee quality in Brazil, mainly due to the harvesting method adopted. Brazilian harvests are based on fruits collected from the ground mixed with those that fall on collection cloths. As the Bacillus cereus bacterium frequently uses the soil as its environmental reservoir, it is easily capable of becoming a contaminant. This study aimed to evaluate the contamination and potential of B. cereus enterotoxin genes encoding the HBL and NHE complexes, which were observed in strains of ground and roasted coffee samples sold in Rio de Janeiro. The PCR (Polymerase Chain Reaction) results revealed high potential of enterotoxin production in the samples. The method described by Speck (1984) was used for the isolation of contaminants. The investigation of the potential production of enterotoxins through isolates of the microorganism was performed using the B. cereus enterotoxin Reverse Passive Latex Agglutination test-kit (BCET-RPLA, Oxoid), according to the manufacturer's instructions. The potential of enterotoxin production was investigated using polymerase chain reaction (PCR) methods for hblA, hblD and hblC genes (encoding hemolysin HBL) and for nheA, nheB and nheC genes (encoding non-hemolytic enterotoxin - NHE). Of all the 17 strains, 100% were positive for at least 1 enterotoxin gene; 52.9% (9/17) were positive for the 3 genes encoding the HBL complex; 35.3% (6/17) were positive for the three NHE encoding genes; and 29.4% (5/17) were positive for all enterotoxic genes.
Resumo:
The purpose of this study was to verify and compare the main contamination sources and the hygienic/sanitary conditions of organic honey samples of Apis mellifera from Parana River islands. Thirty-three (33) samples were analyzed between January 2005 and August 2006. Eleven (11) samples were collected by beekeepers and twenty-two (22) samples were collected and processed in accordance with ideal personal hygiene norms and good manufacturing practices. The samples underwent microbiological analysis in search of coliforms at 35 ºC and 45 ºC, as well as fungi enumeration analysis. As for fungi counting, the samples harvested by beekeepers showed values above the maximum established by Resolution nº 15/94 of Common Market Group - Mercosul. The results showed that secondary contamination sources are responsible for the reduction of organic honey quality.
Resumo:
This research was carried out to evaluate the physicochemical composition of organic honey in Paraná River islands, in Porto Brasílio, State of Paraná. Honey was harvested directly from super of the colonies in three apiaries spread in the Floresta and Laranjeira Islands, from August 2005 to August 2006. Twenty-four samples of organic honey produced by Africanized honeybees were evaluated. The following parameters were analyzed: pH, acidity, formol index, hydroxymethylfurfural, ashes, color, electric conductivity and moisture. Three replications per sample were performed for laboratorial analysis, giving the means and standard deviation. Most honey samples were in conformity with the Normative Instruction 11 from October 20, 2000. However, 4.17% were not in accordance with the moisture standards, 8.33% showed high concentrations of hydroxymethylfurfural, thus, totalizing 12.50% of non-complying samples. Nevertheless, 87.50% of the analyzed honey samples are within the standards, being characterized as an organic product of excellent quality, with good commercialization perspectives in the market.
Resumo:
A biosensor was developed for spectrophotometric determination of glucose concentrations in real samples of orange juice energetic drinks, and sport drinks. The biosensor consisted of glucose oxidase (GOD) and horseradish peroxidase (HRP) immobilized onto polyaniline activated with glutaraldehyde (PANIG). Immobilization parameters were optimized for GOD, and maximum immobilization yield was 16% when 5.0 mg of PANIG and 8.9 U prepared in 0.1 mol.L-1 sodium phosphate buffer (pH 7.0) reacted for 60 minutes at 4 °C with gentle stirring. The linear operational range for glucose determination using optimized operational parameters was between 0.05 and 6.0 mg.mL-1 with a very good reproducibility of response. The results obtained in the biosensor were compared with those obtained using free enzymes (commercial kits) and then validated through statistical analysis using the Tukey test (95% confidence interval).
Resumo:
Cassava producers in the region of Marília-São Paulo are integrating their farming activity with beekeeping to diversify their income. The aim of this study was to evaluate the physicochemical and microbiological quality of honey samples produced by Africanized honeybees Apis mellifera from cassava flower in 2008. Analysis were carried out for pH, total soluble solids (TSS), acidity, moisture, reducing and total sugars, apparent sucrose, hydroxymethylfurfural, color, ash, proteins, water insoluble solids, diastasic activity, mineral content, microbiological evaluations, and mineral and hydrocyanic acid (HCN) content. The honey samples showed physicochemical and microbiological characteristics favorable to commercialization, with the exception of apparent sucrose and acidity, which show the need for a narrow focus of attention to the honey maturation degree at the harvest time and more careful monitoring during production and processing. The commercialization of Brazilian cassava honey, still little explored, can be widely spread in the market since the levels of hydrocyanic acid (HCN) showed no consumption risk; in addition the simultaneous production of honey and cassava provides an alternative to family income increase.
Resumo:
Seventy-one samples of sugarcane spirits from small and average size stills produced in the northern and southern Minas Gerais (Brazil) were analyzed for acrolein using HPLC (High Performance Liquid Chromatography). Ethanol and copper concentrations and volatile acidity were also determined according to methods established by the Ministry of Agriculture, Livestock and Supply (MAPA). A total of 9.85% of the samples tested showed levels of acrolein above the legal limits, while the copper concentrations of 21.00% of the samples and the volatile acidity of 8.85% of the samples were higher than the limits established by the Brazilian legislation. The concentration of acrolein varied from 0 to 21.97 mg.100 mL-1 of ethanol. However, no significant difference at 5% of significance was observed between the samples produced in the northern and southern Minas Gerais. The method used for determination of acrolein in sugarcane spirits involved the formation of a derivative with 2,4-dinitrophenylhydrazine (2,4-DNPH) and subsequent analysis by HPLC.
Resumo:
A test that is rapid, simple, accurate, not expensive, gives rapid results, and is sensitive enough to detect low levels of microorganisms would be the most suitable for food industry routine laboratories, or even for a public health laboratories. A ready-to-use alternative, commercially available method is the PetrifilmTM EB method. The aim of this study was to evaluate whether there is a statistically significant difference between the conventional methods based on Violet Red Bile Glucose Agar and the alternative 3M TM Petrifilm (EB) method for the enumeration of Enterobacteriaceae in poultry carcasses. This study also assessed whether the alternative method showed ability to produce results that were directly proportional to the concentration of the target (approximately 270 colony-forming unit.mL-1). A total of 120 poultry carcasses samples showed a significant difference (p < 0.05) between the populations obtained by the two methods, and the conventional method showed low proportionality between the dilutions. On the other hand, the PetrifilmTM EB quantification system showed the capacity to produce results that are proportional to the concentration of the analyte in samples in the concentration range from 1 to 256 colony-forming unit.mL-1.
Resumo:
This study evaluated the physicochemical properties and protein and mineral content of honey samples from Ceará State, Northeastern Brazil, one of the major honey exporters in the country. Nutritional importance of the minerals detected was also analyzed. Physicochemical properties were examined according to the AOAC and CAC official methods; the protein content was determined using the Bradford method, and the minerals were analyzed by atomic absorption spectrometry. All analyses were performed in triplicate. The levels of macrominerals sodium (Na), potassium (K), calcium (Ca), and magnesium (Mg) varied from 1.80-47.20, 21.30-1513.30, 14.58-304.82, and 2.48-28.33 mg/kg, respectively, and the trace elements iron (Fe), copper (Cu), manganese (Mn), zinc (Zn), selenium (Se), and chromium (Cr) varied from 0.12-8.76, 0.07-1.29, 0.06-1.96, 0.07-1.85 mg/kg, 0.36 × 10-3-62.00 × 10-3 and 22.50 × 10-3-170.33 × 10-3 µg/kg, respectively. Myracrodruon urundeuva honey sample had high contents of macrominerals (Na, K, Ca, and Mg). Protein content of the Anacardium occidentale honey sample was the highest (1121.00 µg/g) among the samples analyzed. Among the minerals detected in the honey samples, K showed the highest concentration, followed by Ca, Na, and Mg. The presence of trace elements can show environmental contamination. The honey samples studied were free of trace elements contamination, except for Mn; the Piptadenia moniliformis was the only honey sample that was in compliance with the law requirements. The variations of the chemical constituents in the honey samples are probably related to differences in the floral origin and mineral and protein contents and confirm the nutritional importance of Ceará State honey.