932 resultados para AMP hydrolysis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Routledge Guide to Interviewing sets out a well-tested and practical approach and methodology: what works, difficulties and dangers to avoid and key questions which must be answered before you set out. Background methodological issues and arguments are considered and drawn upon but the focus is on what is ethical, legally acceptable and productive:
-Rationale (why, what for, where, how)
-Ethics and Legalities (informed consent, data protection, risks, embargoes)
-Resources (organisational, technical, intellectual)
-Preparation (selecting and approaching interviewees, background and biographical research, establishing credentials, identifying topics)
-Technique (developing expertise and confidence)
-Audio-visual interviews
-Analysis (modes, methods, difficulties)
-Storage (archiving and long-term preservation)
-Sharing Resources (dissemination and development)

From death row to the mansion of a head of state, small kitchens and front parlours, to legislatures and presbyteries, Anna Bryson and Seán McConville’s wide interviewing experience has been condensed into this book. The material set out here has been acquired by trial, error and reflection over a period of more than four decades. The interviewees have ranged from the delightfully straightforward to the painfully difficult to the near impossible – with a sprinkling of those that were impossible.
Successful interviewing draws on the survival skills of everyday life. This guide will help you to adapt, develop and apply these innate skills. Including a range of useful information such as sample waivers, internet resources, useful hints and checklists, it provides sound and plain-speaking support for the oral historian, social scientist and investigator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of collective memory on political identity in Ireland has been well documented. It has particular force in Northern Ireland where there is fundamental disagreement about how and why the conflict erupted and how it should be resolved. This article outlines some of the issues encountered by an ‘insider’ when attempting to record and analyse the conflicting memories of a range of Protestants and Catholics who grew up in Mid-Ulster in the decades preceding the Troubles. In particular, it considers the challenges and opportunities presented by a two-pronged approach to oral history: using testimony as evidence about historical experience in the past and as evidence about historical memory – both collective and individual – in the present.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we propose a system level design approach considering voltage over-scaling (VOS) that achieves error resiliency using unequal error protection of different computation elements, while incurring minor quality degradation. Depending on user specifications and severity of process variations/channel noise, the degree of VOS in each block of the system is adaptively tuned to ensure minimum system power while providing "just-the-right" amount of quality and robustness. This is achieved, by taking into consideration system level interactions and ensuring that under any change of operating conditions only the "lesscrucial" computations, that contribute less to block/system output quality, are affected. The design methodology applied to a DCT/IDCT system shows large power benefits (up to 69%) at reasonable image quality while tolerating errors induced by varying operating conditions (VOS, process variations, channel noise). Interestingly, the proposed IDCT scheme conceals channel noise at scaled voltages. ©2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Dementia is a significant worldwide health issue, however, it is often insidious in onset and difficult to diagnose, therefore GPs have expressed a limited confidence in their diagnostic skills, extending into their prognostication of the disease. As a result diagnosing the terminal phase of dementia has been identified as a significant challenge to delivering effective palliative care. Therefore, identifying the challenges faced by the GPs in this field will help to guide their training and support, and as a result could assist in the provision of sustained and effective palliative care for their dementia patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.