945 resultados para spine segment stiffness
Resumo:
The aim of this study is to compare polyurethanes containing castor oil (soft segment) in granular form compared to cancellous bone autograft applied to a segmental bone defect. Norfolk adult female rabbits - approximately 13 months of age with a mean body weight of 4.5 kg - are used. In both radial diaphyses, 1 cm osteoperiosteal segmental defects are created. The defect in the left radius is filled with the castor-oil-based polyurethane, and the right one, filled with cancellous bone autograft, collected from the left proximal humerus. The rabbits are euthanazed at 15, 30, 60, and 120 days postsurgery (5 animals/ period), for histological analyses. By radiographic analyses, at these time points, the bone regeneration is more evident and accelerated in the bone defects treated with the cancellous bone autograft. At 120 days postsurgery, the segmental bone defects treated with the cancellous bone autograft are totally reconstituted and remodeled, while the bone defects treated with polyurethane polymer have bone formation of 79%. Histological study shows that the polyurethane acts as a space filler, minimizing the local production of fibrous tissue. No granule degradation, resorption or any inflammatory reaction is detected. Thus, it is possible to conclude that the castor-oil-plant-based polyurethane - in the granule presentation - is biocompatible and osteointegrated, but does not show the same bone regeneration capacity as the cancellous bone autograft. © 2007 SAGE Publications.
Resumo:
This article evaluates space closure mechanics efficiency in an extraction case where maximum anchorage was a requirement. The Segmented Arch Technique (SAT) was utilized as an anchorage control strategy to obtain maximum anterior retraction and, in consequence, significant facial profile change. A 20-year-10-month old woman needed severe labial and profile changes. The patient had four premolars extracted and SAT with type A mechanics [1] (Marcotte [2] activation protocol) was applied. The results showed significant reduction in labial protrusion and incisal angulation with effective anchorage control. The results were compared to others available in the literature derived from different techniques, where anterior retraction was also accomplished with maximum anchorage [3-7]. In conclusion, the SAT with type A mechanics has been shown to be another treatment option when significant changes in the soft-tissue profile are needed in extraction cases. © 2008. CEO. Published by Elsevier Masson SAS. All rights reserved.
Resumo:
Three methods are used to determine the natural frequency of undamped free vibration of a mass interacting with a Hertzian contact stiffness. The exact value is determined using the first integral of motion. The harmonic balance method is used on a transformed equation for an approximate solution, and the multiple scales method is used on an approximate equation. The maximum initial displacement avoiding contact loss is also determined, and the corresponding exact natural frequency is also obtained analytically. The methods are evaluated by studying the free vibration of an elastic sphere on a flat rigid surface. © 2011 Elsevier Ltd © 2011 Elsevier Ltd. All rights reserved.
Resumo:
Two new species of Diaptomidae were found in the Middle Paraná River. The new species are referred to as Diaptomus curvatus sp. nov. and Diaptomus frutosae sp. nov. Important character states in Diaptomus curvatus include: right fifth leg with a well-developed endopod and with the lateral spine of the second exopod segment curved and longer than the segment on which it is inserted, plus the presence of a large dorsal process on urosomite 4 of the male. For Diaptomus frutosae they include: a differentiated hook-like process on segment 20 with chitinous protuberances at base of male right antennule; the last segment of the right leg 5 of male is triangular, and the lateral spine inserted distal to mid-level of this segment. Both species are placed in Diaptomus sensu lato as a temporary placement. http://www.zoobank.org/urn:lsid:zoobank.org:pub:FECDD6C4-C0AC-4043-ADDD-F29539B451F0. © 2013 Copyright Taylor and Francis Group, LLC.
Resumo:
STUDY DESIGN. Observational cohort study. OBJECTIVE. To investigate spinal coordination during preferred and fast speed walking in pain-free subjects with and without a history of recurrent low back pain (LBP). SUMMARY OF BACKGROUND DATA. Dynamic motion of the spine during walking is compromised in the presence of back pain (LBP), but its analysis often presents some challenges. The coexistence of significant symptoms may change gait because of pain or adaptation of the musculoskeletal structures or both. A history of LBP without the overlay of a current symptomatic episode allows a better model in which to explore the impact on spinal coordination during walking. METHODS. Spinal and lower limb segmental motions were tracked using electromagnetic sensors. Analyses were conducted to explore the synchrony and spatial coordination of the segments and to compare the control and subjects with LBP. RESULTS. We found no apparent differences between the groups for either overall amplitude of motion or most indicators of coordination in the lumbar region; however, there were significant postural differences in the mid-stance phase and other indicators of less phase locking in controls compared with subjects with LBP. The lower thoracic spinal segment was more affected by the history of back pain than the lumbar segment. CONCLUSION. Although small, there were indicators that alterations in spinal movement and coordination in subjects with recurrent LBP were due to adaptive changes rather than the presence of pain. © 2013, Lippincott Williams & Wilkins.
Resumo:
The purpose of this study is to develop a dynamic vibration absorber using viscoelastic material with nonlinear essential stiffness and time-dependent damping properties for a non-ideal vibrating system with Sommerfeld effect, resonance capture, and jump phenomenon. The absorber is a mass-bar subsystem that consists of a viscoelastic bar with memory attached to mass, in which the internal dissipative forces depend on current, deformations, and its operational frequency varies with limited temperature. The non-ideal vibrating system consists of a linear (nonlinear) oscillator (plane frame structure) under excitation, via spring connector, of a DC-motor with limited power supply. A viscoelastic dynamic absorber modeled with elastic stiffness essentially nonlinearities was developed to further reduce the Sommerfeld effect and the response of the structure. The numerical results show the performance of the absorber on the non-ideal system response through the resonance curves, time histories, and Poincarésections. Furthermore, the structure responses using the viscoelastic damper with and without memory were studied. © IMechE 2012.
Resumo:
PURPOSE: To investigate and compare the biocompatibility of two types of Ferrara intracorneal ring segment: with and without chondroitin sulfate coating by clinical and histopathological evaluation. METHODS: A randomized experimental study was carried out on thirty right-eye corneas from 30 Norfolk albino rabbits allocated into two experimental groups: Group G1 - implanted with Ferrara intracorneal ring segment without coating (FICRS) and Group G2 - implanted with Ferrara intracorneal ring segment with chondroitin sulfate coating (FICRS-CS). Left eyes formed the control group. Clinical parameters analyzed were: presence of edema, vascularization, infection and ring extrusion one, 30, and 60 days after surgery. Histopathological parameters analyzed were: number of corneal epithelial layers over and adjacent to the ring, presence of spongiosis, hydropic degeneration, basement membrane thinning, inflammatory cells, neovascularization and pseudocapsule formation. RESULTS: At clinical examination 60 days after implant, edema, vascularization and extrusion were observed respectively in 20%, 26.7%, 6.7% of FICRS corneas and in 6.7%, 6.7%, and 0% of FICRS-CS corneas. Histopathological evaluation showed epithelial-layer reduction from 5 (5;6) to 3 (3;3) with FICRS and from 5 (5;5) to 4 (3;5) with FICRS-CS in the region over the ring. Epithelial spongiosis, hydropic degeneration, and basement membrane thinning were present in 69.2%, 53.8%, and 69.2% of FICRS and in 73.3%, 73.3%, and 46.7% with FICRS-CS, respectively. Vascularization was present in 38.5% of FICRS and 13.3% with FICRS-CS, inflammatory cells in 75% of FICRS and 33.3% with FICRS-CS, and pseudocapsule in 66.7% of FICRS and 93.3% with FICRS-CS. Giant cells occurred only in the FICRS-CS group (20%). CONCLUSION: Ferrara intracorneal rings coated with chondroitin sulfate (FICRS-CS) caused lower frequency of clinical and histopathological alterations than Ferrara intracorneal rings without the coating (FICRS), demonstrating higher biocompatibility of the FICRS-CS.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)