972 resultados para safety education
Resumo:
Background: Verbal fluency (VF) tasks are simple and efficient clinical tools to detect executive dysfunction and lexico-semantic impairment. VF tasks are widely used in patients with suspected dementia, but their accuracy for detection of mild cognitive impairment (MCI) is still under investigation. Schooling in particular may influence the subject`s performance. The aim of this study was to compare the accuracy of two semantic categories (animals and fruits) in discriminating controls, MCI patients and Alzheimer`s disease (AD) patients. Methods: 178 subjects, comprising 70 controls (CG), 70 MCI patients and 38 AD patients, were tested on two semantic VF tasks. The sample was divided into two schooling groups: those with 4-8 years of education and those with 9 or more years. Results: Both VF tasks - animal fluency (VFa) and fruits fluency (VFf) - adequately discriminated CG from AD in the total sample (AUC = 0.88 +/- 0.03, p < 0.0001) and in both education groups, and high educated MCI from AD (VFa: AUC = 0.82 +/- 0.05, p < 0.0001; VFf: AUC = 0.85 +/- 0.05, p < 0.0001). Both tasks were moderately accurate in discriminating CG from MCI (VFa: AUC = 0.68 +/- 0.04, p < 0.0001 - VFf:AUC = 0.73 +/- 0.04, p < 0.0001) regardless of the schooling level, and MCI from AD in the total sample (VFa: AUC = 0.74 +/- 0.05, p < 0.0001; VFf: AUC = 0.76 +/- 0.05, p < 0.0001). Neither of the two tasks differentiated low educated MCI from AD. In the total sample, fruits fluency best discriminated CG from MCI and MCI from AD; a combination of the two improved the discrimination between CG and AD. Conclusions: Both categories were similar in discriminating CG from AD; the combination of both categories improved the accuracy for this distinction. Both tasks were less accurate in discriminating CG from MCI, and MCI from AD.
Resumo:
BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)
Resumo:
Background: Dementia screening in elderly people with low education can be difficult to implement. For these subjects, informant reports using the long (L) (26 items) and short (C) (16 items) versions of the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) can be useful. The objective of the present study was to investigate the performance of Brazilian versions of the IQCODE L, S and a new short version (SBr) (15 items) in comparison with the Mini-mental State Examination (MMSE) for dementia screening in elderly people with low education. Methods: Thirty-four patients with mild to moderate dementia, diagnosed according to ICD-10 criteria, and 57 controls were evaluated and divided into three groups based on their socioeconomic status and level of education. Patients were evaluated using the MMSE and the informants were interviewed using the IQCODE by interviewers blind to the clinical diagnosis. Results: Education was correlated with MMSE results (r = 0.280, p = 0.031), but not with the versions of the IQCODE. The performance of the instruments, evaluated by the ROC curves, was very similar, with good internal consistency (Cronbach`s alpha = 0.97). MMSE correctly classified 85.7% of the subjects while the three IQCODE versions (L, S and SBr) correctly classified 91.2% of the subjects. Conclusions: The long, short and the new short Brazilian IQCODE versions can be useful as a screening tool for mild and moderate patients with dementia in Brazil. The IQCODE is not biased by schooling, and it seems to be an adequate instrument for samples with low levels of education.
Resumo:
Background The CAMCOG is a brief neuropsychological battery designed to assess global cognitive function and ascertain the impairments that are required for the diagnosis of dementia. To date, the cut-off scores for mild cognitive impairment (MCI) have not been determined. Given the need for an earlier diagnosis of mild dementia, new cut-off values are also necessary, taking into account cultural and educational effects. Methods One hundred and fifty-seven older adults (mean age: 69.6 +/- 7.4 years) with 8 or more years of formal education (mean years of schooling 14.2 +/- 3.8) attending a memory clinic at the Institute of Psychiatry University of Sao Paulo were included. Subjects were divided into three groups according to their cognitive status, established through clinical and neuropsychological assessment: normal controls, n = 62; MCI, n = 65; and mild or moderate dementia, n = 30. ROC curve analyses were performed for dementia vs controls, MCI vs controls and MCI vs dementia. Results The cut-off values were: 92/93 for dementia is controls (AUC = 0.99: sensitivity: 100%, specificity: 95%); 95/96 for MCI vs controls (AUC = 0.83, sensitivity: 64%, specificity: 88%), and 85/86 for MCI vs dementia (AUC = 0.91, sensitivity: 81%, specificity: 88%). The total CAMCOG score was more accurate than its subtests Mini-mental State Examination, Verbal Fluency Test and Clock Drawing Test when used separately. Conclusions The CAMCOG discriminated controls and MCI from demented patients, but was less accurate to discriminate MCI from controls. The best cut-off value to differentiate controls and demented was higher than suggested in the original publication, probably because only cases of mild to moderate dementia were included. This is important given the need for a diagnostic at earlier stages of Alzheimer`s disease. Copyright (C) 2008 John Wiley & Sons, Ltd.
Resumo:
Introduction: Pediatric percutaneous renal biopsy (Bx) is a routine procedure in pediatric nephrology to obtain renal tissues for histological study. We evaluated the safety, efficacy, indications and renal findings of this procedure at a tertiary care pediatric university hospital and compared our findings with the literature. Methods: Retrospective study based on medical records from January 1993 to June 2006. Results: In the study period, 305 Bx were performed in 262 patients, 127 (48.5%) male, aged 9.8 +/- 4.2 years. A 16-gauge needle was utilized in 56/305 Bx, an 18-gauge needle in 252/305 Bx (82.6%). 56.1% Bx were performed under sedation plus local anesthesia, 43.9% under general anesthesia. The number of punctures per Bx was 3.1 +/- 1.3. Minor complications occurred in 8.6% procedures. The 16-gauge needle caused a higher frequency of renal hematomas (p = 0.05). The number of glomeruli per puncture was >= 5 in 96.7% and >= 7 in 92%. Glomeruli number per puncture and frequency of complications were not different according to the type of anesthesia used. A renal pathology diagnosis was achieved in 93.1% Bx. The main indications of Bx were nephrotic syndrome (NS), lupus nephritis (LN) and hematuria (HE). The diagnosis of minimal change disease (MCD) (61.3%), class V (35.6%) and IgA nephropathy (26.3%) predominated in NS, LN and HE patients, respectively. Conclusion: Pediatric real-time ultrasound-guided percutaneous renal biopsy was safe and effective. The main clinical indications for Bx were NS and LN, the predominant renal pathology diagnoses were MCD and class V LN.