632 resultados para phasic contractions


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anchietia salutaris tea is traditionally used in Brazil to treat allergies, suggesting it contains compounds with antagonistic activity on the allergic mediators. We have evaluated extracts and semi-purified fractions of Anchietia salutaris as a source of compounds having this type of antagonism on the contraction induced in guinea-pig lung parenchymal strips and on platelet aggregation and shape change. After 10 min pre-incubation dichloromethane extracts containing 30 or 100 μg mL-1 inhibited the contraction induced by prostaglandin D2 (PGD2) in guinea-pig lung parenchymal strips with dose ratios (DR) of 0.76 ± 0.14 and 0.93 ± 0.19, respectively; the amount of inhibition depended both on the concentration and on the time of preincubation (DR after 30 min pre-incubation was 1.21 ± 0.51). The dichloromethane extract and its semi-purified fractions also inhibited the contractions induced by U46619, a more potent, stable, synthetic agonist of thromboxane A2 (TxA2) prostanoid (TP) receptors, the receptors acted upon by PGD2 to produce lung contractions. The dichloromethane extract did not inhibit the lung parenchymal contractions induced by histamine, leukotriene D4 (LTD4) or platelet-activating factor (PAF). Platelet aggregation induced by U46619, adenosine 5'-diphosphate (ADP) or PAF was not inhibited by the dichloromethane extract. Indeed, the extract potentiated platelet aggregation induced by low concentrations of these agonists and also potentiated the shape change induced by U46619. These results imply that the dichloromethane extract of Anchietia salutaris and its semipurified fractions contain an active principle that competitively inhibits TxA2 TP receptors, the stimulation of which causes lung parenchymal contraction. The inhibition seems to be selective for this receptor subtype, because the extract fails to inhibit platelet aggregation or shape change. This provides additional support of earlier reports suggesting the occurrence of TP receptor subtypes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To identify the electromyographic fatigue threshold in the erector spinae muscle. Methods: Eight 19 to 24-year-old male volunteers participated in this study, in which surface electrodes were used, as well as a biological signals acquisition module (Lynx) with a sampling frequency of 1000Hz, a 1000 times gain, a 20Hz high pass filter and a 500Hz low pass filter. The test consisted of repeated isometric contractions of the erector spinae muscle in a 45° hip flexion posture, with 30%, 40%, 50% and 60% of the maximum voluntary isometric contraction. Results: A positive correlation of the RMS (root mean square) value as a function of time was found for most of the subjects with 40% (N = 6), 50% (N = 7) and 60% (N = 8) loads of the maximum voluntary isometric contraction. Conclusions: It was concluded, from this study, that the proposed protocol provides evidence, through the electromyographic signal, of the development of fatigue in the erector spinae muscle with loads of 40%, 50% and 60% of the maximum voluntary isometric contraction. The protocol also allows the electromyographic fatigue threshold and its probable applicability in the diagnosis of this phenomenon during repetitive activities to be determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to identify the Electromyographic Fatigue Threshold (EMG FT) of the biceps brachii muscle bilaterally during the elbow flexion in tests performed in different times: 30 second test, 1 minute test and fatiguing test, in concentric (CC) and eccentric (EC) phases. Nine healthy young men performed the elbow flexion with loads corresponding at 25%, 35% and 45% of the one repetition maximum (1-RM) in separate days. The results indicated that the test applied for the biceps brachii muscle during elbow flexion induced a progressive increment of EMG activity with time indicating muscle fatigue and allowed the identification of the EMG FT. The three tests presented no difference of EMG FT between CC and EC phases bilaterally.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The magnitude of men and women's neuromuscular, metabolic, and morphologic responses seems to be quite different even when both are submitted to exercise protocols using similar weight exercises protocols. However, differences in the motor performance between men and women have been predominantly reported in protocols based on isometric and isokinetic contractions. Thus, this study aimed to analyze men and women's behavior during multiple sets of weight exercises achieving the exhaustion, and later verifying possible differences as to the physical performance between genders using weights with similar intensity. For this, 83 subjects (50 men, and 33 women), 48 hours after being submitted to 1-RM tests in bench press, squat and arm curl performed a protocol composed by four sets at 1-RM 80% up to achieving the exhaustion in each of three exercises to evaluate the endurance ability to the fatigue in different muscular groups. It was used the ANOVA and ANCOVA for repeated measurements, followed by the Tukey's post hoc test, where P < 0.05 to the data treatment. It was verified a significant fall in the performance both in men and in women since the first up to the fourth sets of every exercise investigated (P < 0.01). Although the fatigue magnitude was higher in men in all the three exercises, the effect on the gender was only identified in the arm curl exercise (P < 0.01). The results of this study indicated that men and women presented quite different behavior in multiple sets of weight exercises, and women presented a more stable performance and a higher endurance ability to the fatigue in the arm curl as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The phylogenetic proximity of primates to humans, along with their behavioral, biochemical, and anatomical similarities, make such animals more interesting experimental models for biomedical researches, as compared to classical laboratory animals. Another aspect that has called the attention of researchers is the differentiated quadrupedalism present in some primates. The tufted capuchin monkey uses the ground and tree branches as its support for locomotion, showing various postures while performing this task. On the basis of this information, we have decided to study the rectus abdominis muscle of the tufted capuchin monkey, with the following goals: the frequency and area of fiber types; its possible compartmentalization; and identify if this muscle is better adapted to phasic or postural activities. To do this, samples were removed from 4 regions of the rectus abdominis muscle of 6 adult male tufted capuchin monkeys, and were submitted to reaction with m-ATPase, (with alkaline and acid pre-incubation), NADH, and H.E.. Results showed: a statistically significant difference (P<0.05) for both frequency and area, between fiber types FG and FOG and FG and SO, but did not show a statistically significant difference between fibers FOG and SO, in all studied regions; similarity in frequency and area of a same fiber type (FG, FOG, and SO) among the studied regions. Based on these data, it was concluded that: the rectus abdominis muscle of the tufted capuchin monkey does not show fiber compartmentalization, since the distribution and size patterns of the different fiber types are similar in the studied regions; there is a predominance of fast twitch fibers (FG + FOG) over slow twitch fibers (SO), for frequency and area, which characterizes the muscle as being more dedicated to phasic than to postural activities. © 2006 Sociedad Chilena de Anatom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Muscle fatigue can be a limiting factor to determine index as the electromyographic fatigue threshold (EMGFT) due the alterations in motivation and disconfots. This way, the purpose of this study was to identify the right biceps brachii and left biceps brachii obtained from repetitive elbow flexions at each 10% of total time. Nine healthy subjects performed the exercise named biceps curl until exhaustion with 25%, 35%, and 45% of one repetition maximum, in three different days. EMG amplitude (root mean square - RMS) was obtained for concentric contractions during these load levels and correlated with time to determine the slope values for each load and them detemine the EMGFT. The EMGFT was obtained within of each 10% of total time and they were compared by analysis of variance. The results showed a progressive increase in RMS with time, for both muscles in all loads, characterizing the muscle fatigue process, and for the EMGFT values ware not found predominantly significant differences between the execution time, as well as between muscles (right biceps × left biceps). This protocol allowed to identify the EMGFT to both muscles during the biceps curl, which was similar at different percentage of total time, indicating the possibility to reduce the length of the contraction test without the need to maintain the contraction until exhaustion. Further studies are needed to evaluate the applicability of this method to determining the effects on performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel instrumentation using anisotropic magnetoresistive (AMR) sensors associated with magnetic coils excitation was developed to evaluate gastrointestinal tract motility parameters. The susceptometer has four sensors that were used to measure the gastric activity contractions (GAC) in anaesthetized dogs, its performance was evaluated by manometry with good results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this randomized study was to evaluate EMG spectral, subjective and cardiovascular recovery parameters after isometric lumbar extension contractions. Ten healthy women performed isometric lumbar extensions until exhaustion with 5%, 10%, 15% and 20% of maximal voluntary isometric contraction on 4 different days (random order). One baseline five second contraction was performed before the fatiguing task which was followed by eight submaximal five second extension contractions (until 20 minutes after the end of the fatiguing task) at the same intensity as the trial to evaluate muscle recovery. EMG (Median Frequency, Peak Power, Peak Power Frequency, Total Power and Zero-crossing Rate) and cardiovascular variables did not demonstrate any statistical difference between the 5-second contractions (p > 0.05) performed before and after the fatiguing task, showing a quick EMG recovery. However, the data analysis showed that the perceived effort variable had not recovered even 10 minutes after the fatigue contraction (p < 0.05). Our results represent a data basis for future comparisons and since subjective felling can affect performance, this study shows the importance of its analysis, since the subjective effort rate was not fully recovered after 10 minutes the end of the exhaustion contraction. © 2008 IOS Press. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the time to restore the biceps brachii (BB) electromyographic (EMG) activity after the biceps curl (BC) exercise, at different intensities. Ten males performed initially maximal voluntary isometric contractions (MVC) of the elbow flexors, followed by one isometric submaximal contraction at 50% MVC (reference contraction). After this, four bouts of the BC at 25%, 30%, 35%, and 40% 1 RM during 1 minute (randomly assigned, with 10 minutes rest between them) were performed. During the rest intervals at preestablished moments (15 seconds, 1, 3, 5, and 10 min), isometric 50% MVC were performed. The EMG variables (root mean square [RMS], zero crossings [ZC], median frequency, [MF] and peak power [PP]) at rest were compared with reference values. Immediately after the exercise, RMS and PP increased, while ZC and MF decreased, indicating fatigue. After 1 minute most of the variables were similar to the reference. Different load levels did not affect the EMG recovery. In conclusion, the EMG variables recovered after 1 minute rest, indicating the optimal muscular condition for subsequent bouts. Copyright © Taylor & Francis Group, LLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to investigate if chronic eccentric strength training (ST) affects heart rate (HR) and heart rate variability (HRV) during sub-maximal isometric voluntary contractions (SIVC). The training group (TG) (9 men, 62 ± 2) was submitted to ST (12 weeks, 2 days/week, 2 - 4 sets of 8-12 repetitions at 75-80% peak torque (PT). The control group (CG) (8 men, 64 ± 4) did not perform ST. The HR and the HRV (RMSSD index) were evaluated during SIVC of the knee extension (15, 30 and 40% of PT). ST increased the eccentric torque only in TG, but did not change the isometric PT and the duration of SIVC. During SIVC, the HR response pattern and the RMSSD index were similar for both groups in pre- and post-training evaluations. Although ST increased the eccentric torque in the TG, it did not generate changes in HR or HRV. © Springer-Verlag 2008.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is the first study performed with an interocclusal splint with a vibrating device on patients with sleep bruxism. The purpose of the present study was to evaluate the effectiveness of the splint with vibrating device on patients who suffer from sleep bruxism through computerized electromyography (EMG) of the anterior temporal muscles. Eight male and female patients, ranging in age from 18 to 28 years, with evident signs and symptoms of bruxism were selected. The splint were made for the upper arch. The patients was treated with the interocclusal splint with a vibrating device, and submitted to EMG evaluations of the anterior temporal muscles on both sides. The evaluations were performed at the beginning of treatment and after 21 days of splint use. Electromyography was performed in an isometric contractions measuring of the temporal muscles. The following results obtained revealed that: when closing the mandible (isometric contraction), the anterior temporal muscles had an expressive reduction in electromyographic activity (p. < 0.10), so this splints were considered effective for patients who suffer from sleep bruxism. © 2009 Springer-Verlag.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

the aim of this study was to validate the Alternate Current Biosusceptometry (ACB) for monitoring gastric contractions in rats. In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed on rats with magnetic markers and SGs previously implanted under the gastric serosa. The effects of the prandial state in gastric motility profiles were obtained. The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation between the ACB and SG signal amplitude was higher in the postprandial than in the fasting state. Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation for fasting-state recordings. The contraction frequencies using ACB were 0.068 ± 0.007 Hz (postprandial) and 0.058 ± 0.007 Hz (fasting) and those using SG were 0.066 ± 0.006 Hz (postprandial) and 0.059 ± 0.008 Hz (fasting) (P < 0.003). When a magnetic tracer was ingested, there was a strong correlation and a small phasedifference between techniques. We conclude that ACB provides an accurate and sensitive technique for studies of GI motility in the rat. © 2010 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using two standard cycle methodologies (Classical and Deviation Cycle) and a comprehensive sample of 83 countries worldwide, including all developing regions, we show that the Latin American and Caribbean cycle exhibits two distinctive features. First, and most importantly, its expansion performance is shorter and for the most par less imtense than that of the rest of the regions considered, and in particular than that of East Asia and the Pacific, East Asia and the Pacific's expansions last five years longer than those of LAC, and its output gain is 50% greater than that of LAC. Second, LAC tends to exhibit contractions that are not significantly different in terms of duration and amplitude than t those of other regions. Both these features imply that the complete Latin American and Caribbean cycle has, overall, the shortest duration and smallest amplitude in relation to other regions. The specificities of the Latin American and Caribbean cycle are not confined to the short run. These are also reflected in variables such as productivity and investment, which are linked to long-run growth. East Asia and the Pacific's cumulative gain in labor productivity during the expansionary phase is twice that of LAC. Moreover, the evidence also shows that the effects of the contraction in public investment surpass those of the expansion leading to a declining trend over the entire cycle. In this sense we suggest that policy analysis needs to increase its focus on the expansionary phase of the cycle. Improving our knowledge of the differences in the expansionary dynamics of countries and regions, can further our understanding of the differences in their rates of growth and levels of development. We also suggest that while, the management of the cycle affects the short-run fluctuations of economic activity and hence volatility, it is not trend neutral. Hence, the effects of aggregate demand management policies may be more persistent over time and less transitory than currently thought.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: The effect of exercise training (ET) on vascular responsiveness in diabetes mellitus has been largely well studied. However, limited studies have investigated the effects of ET on functional responses of the corpus cavernosum (CC) in diabetic animals. Therefore, the aim of this study was to investigate whether prior ET prevents the impairment of erectile function in streptozotocin-induced diabetic rats. Main methods: Rats were exercised for four weeks prior to the induction of diabetes, and then again for another 4 weeks thereafter. Concentration-response curves to acetylcholine, sodium nitroprusside, Y-27632, BAY 412272 and phenylephrine (PE) were obtained in CC. The excitatory and inhibitory effects of electrical-field stimulation were also evaluated. Key findings: Plasma SOD levels were markedly decreased in the sedentary diabetic group (D-SD) as compared to control sedentary animals (C-SD), approximately 53% (P < 0.05) and this reduction was restored in trained diabetic animals. Physical training restored the impairment of endothelium-dependent and -independent relaxation responses seen in the D-SD group. The potency values for Y-27632 in the CC were significantly reduced in the D-SD group, which was reversed by physical training. The impairment of electrical-field stimulation (EFS)-induced relaxation seen in the D-SD group was restored by physical training. On the other hand, both EFS-induced contractions and concentration-response curves to PE in cavernosal strips were not modified by either diabetes or physical training. Significance: Practice of regular physical exercise may be an important approach in preventing erectile dysfunction associated with diabetes mellitus by re-establishment of the balance between NO production and its inactivation. © 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. Isokinetic tests are often applied to assess muscular strength and EMG activity, however the specific ranges of motion used in testing (fully flexed or extended positions) might be constrictive and/or be painful for patients with injuries or under-going rehabilitation. The aim of this study was to examine the effects of different ranges of motion (RoM) when determining maximal EMG during isokinetic knee flexion and extension with different types of contractions and velocities. Methods. Eighteen males had EMG activity recorded on the vastus lateralis, vastus medialis, semitendinosus and biceps femoris muscles during five maximal isokinetic concentric and eccentric contractions for the knee flexors and extensors at 60° • s -1 and 180° • s -1. The root mean square of EMG was calculated at three different ranges of motion: (1) a full range of motion (90°-20° [0° = full knee extension]); (2) a range of motion of 20° (between 60°-80° and 40°-60° for knee extension and flexion, respectively) and (3) at a 10° interval around the angle where peak torque is produced. EMG measurements were statistically analyzed (ANOVA) to test for the range of motion, contraction velocity and contraction speed effects. Coefficients of variation and Pearson's correlation coefficients were also calculated among the ranges of motion. Results. Predominantly similar (p > 0.05) and well-correlated EMG results (r > 0.7, p ≤ 0.001) were found among the ranges of motion. However, a lower coefficient of variation was found for the full range of motion, while the 10° interval around peak torque at 180° • s -1 had the highest coefficient, regardless of the type of contraction. Conclusions. Shorter ranges of motion at around the peak torque angle provides a reliable indicator when recording EMG activity during maximal isokinetic parameters. It may provide a safer alternative when testing patients with injuries or undergoing rehabilitation.