950 resultados para accuracy of estimation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We assess the accuracy of the Visante anterior segment optical coherence tomographer (AS-OCT) and present improved formulas for measurement of surface curvature and axial separation. Measurements are made in physical model eyes. Accuracy is compared for measurements of corneal thickness (d1) and anterior chamber depth (d2) using-built-in AS-OCT software versus the improved scheme. The improved scheme enables measurements of lens thickness (d 3) and surface curvature, in the form of conic sections specified by vertex radii and conic constants. These parameters are converted to surface coordinates for error analysis. The built-in AS-OCT software typically overestimates (mean±standard deviation(SD)]d1 by +62±4 μm and d2 by +4±88μm. The improved scheme reduces d1 (-0.4±4 μm) and d2 (0±49 μm) errors while also reducing d3 errors from +218±90 (uncorrected) to +14±123 μm (corrected). Surface x coordinate errors gradually increase toward the periphery. Considering the central 6-mm zone of each surface, the x coordinate errors for anterior and posterior corneal surfaces reached +3±10 and 0±23 μm, respectively, with the improved scheme. Those of the anterior and posterior lens surfaces reached +2±22 and +11±71 μm, respectively. Our improved scheme reduced AS-OCT errors and could, therefore, enhance pre- and postoperative assessments of keratorefractive or cataract surgery, including measurement of accommodating intraocular lenses. © 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate the practicality and accuracy of tonometers used in routine clinical practice for established keratoconus (KC). Methods: This was a prospective study of 118 normal and 76 keratoconic eyes where intraocular pressure (IOP) was measured in random order using the Goldman applanation tonometer (GAT), Pascal dynamic contour tonometer (DCT), Reichert ocular response analyser (ORA) and TonoPen XL tonometer. Corneal hysteresis (CH) and corneal resistance factor (CRF), as calculated by the ORA, were recorded. Central corneal thickness (CCT) was measured using an ultrasound pachymeter. Results: The difference in IOP values between instruments was highly significant in both study groups (p<0.001). All other IOP measures were significantly higher than those for GAT, except for the Goldmann-correlated IOP (average of the two applanation pressure points) (IOPg) as measured by ORA in the control group and the CH-corrected IOP (corneal-compensated IOP value) (IOPcc) measures in the KC group. CCT, CH and CRF were significantly less in the KC group (p<0.001). Apart from the DCT, all techniques tended to measure IOP higher in eyes with thicker corneas. Conclusion: The DCT and the ORA are currently the most appropriate tonometers to use in KC for the measurement of IOPcc. Corneal factors such as CH and CRT may be of more importance than CCT in causing inaccuracies in applanation tonometry techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The studies presented in this thesis were carried out because of a lack of previous research with respect to (a) the habits and attitudes towards retinoscopy and (b) the relative accuracy of dedicated retinoscopes compared to combined types in which changing the bulb allows use in spot or streak mode. An online British survey received responses from 298 optometrists. Decision tree analyses revealed that optometrists working in multiple practices tended to rely less on retinoscopy than those in the independent sector. Only half of the respondents used dynamic retinoscopy. The majority, however, agreed that retinoscopy was an important test. The University attended also influenced the type of retinoscope used and the use of autorefractors. Combined retinoscopes were used most by the more recently qualified optometrists and few agreed that combined retinoscopes were less accurate. A trial indicated that combined and dedicated retinoscopes were equally accurate. Here, 4 optometrists (2 using spot and 2 using streak retinoscopes) tested one eye of 6 patients using combined and dedicated retinoscopes. This trial also demonstrated the utility of the relatively unknown ’15 degrees of freedom’ rule that exploits replication in factorial ANOVA designs to achieve sufficient statistical power when recruitment is limited. An opportunistic international survey explored the use of retinoscopy by 468 practitioners (134 ophthalmologists, 334 optometrists) attending contact related courses. Decision tree analyses found (a) no differences in the habits of optometrists and ophthalmologists, (b) differences in the reliance on retinoscopy and use of dynamic techniques across the participating countries and (c) some evidence that younger practitioners were using static and dynamic retinoscopy least often. In conclusion, this study has revealed infrequent use of static and dynamic retinoscopy by some optometrists, which may be the only means of determining refractive error and evaluating accommodation in patients with communication difficulties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Focal points Over a six-week period in January and February 2002, 2ml samples were removed from all neonatal PN bags dispensed Samples were submitted for analysis of sodium, potassium and magnesium in triplicate by the hospital's clinical chemistry department using a Vitros Codac 950AT, dry slide, automated analyser Only 19.3, 7.1 and 30.4 per cent of measured sodium, potassium and magnesium concentrations respectively deviated by £5 per cent from stated bag concentrations The results indicate that it is possible that some electrolyte concentrations included in neonatal PN vary significantly from stated values

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The accuracy of many aerospace structures is limited by the accuracy of assembly tooling which is in turn limited by the accuracy of the measurements used to set the tooling. Further loss of accuracy results from different rates of thermal expansion for the components and tooling. This paper describes improved tooling designs and setting processes which have the potential to significantly improve the accuracy of aerospace structures. The most advanced solution described is environmentally isolated interferometer networks embedded within tooling combined with active compensation of component pick-ups. This would eliminate environmental effects on measurements while also allowing compensation for thermal expansion. A more immediately realizable solution is the adjustment of component pick-ups using micrometer jacking screws allowing multilateration to be employed during the final stages of the setting process to generate the required offsets. Copyright © 2011 SAE International.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Correct specification of the simple location quotients in regionalizing the national direct requirements table is essential to the accuracy of regional input-output multipliers. The purpose of this research is to examine the relative accuracy of these multipliers when earnings, employment, number of establishments, and payroll data specify the simple location quotients.^ For each specification type, I derive a column of total output multipliers and a column of total income multipliers. These multipliers are based on the 1987 benchmark input-output accounts of the U.S. economy and 1988-1992 state of Florida data.^ Error sign tests, and Standardized Mean Absolute Deviation (SMAD) statistics indicate that the output multiplier estimates overestimate the output multipliers published by the Department of Commerce-Bureau of Economic Analysis (BEA) for the state of Florida. In contrast, the income multiplier estimates underestimate the BEA's income multipliers. For a given multiplier type, the Spearman-rank correlation analysis shows that the multiplier estimates and the BEA multipliers have statistically different rank ordering of row elements. The above tests also find no significant different differences, both in size and ranking distributions, among the vectors of multiplier estimates. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Intoxilyzer 5000 was tested for calibration curve linearity for ethanol vapor concentration between 0.020 and 0.400g/210L with excellent linearity. Calibration error using reference solutions outside of the allowed concentration range, response to the same ethanol reference solution at different temperatures between 34 and 38$\sp\circ$C, and its response to eleven chemicals, 10 mixtures of two at the time, and one mixture of four chemicals potentially found in human breath have been evaluated. Potential interferents were chosen on the basis of their infrared signatures and the concentration range of solutions corresponding to the non-lethal blood concentration range of various volatile organic compounds reported in the literature. The result of this study indicates that the instrument calibrates with solutions outside the allowed range up to $\pm$10% of target value. Headspace FID dual column GC analysis was used to confirm the concentrations of the solutions. Increasing the temperature of the reference solution from 34 to 38$\sp\circ$C resulted in linear increases in instrument recorded ethanol readings with an average increase of 6.25%/$\sp\circ$C. Of the eleven chemicals studied during this experiment, six, isopropanol, toluene, methyl ethyl ketone, trichloroethylene, acetaldehyde, and methanol could reasonably interfere with the test at non-lethal reported blood concentration ranges, the mixtures of those six chemicals showed linear additive results with a combined effect of as much as a 0.080g/210L reading (Florida's legal limit) without any ethanol present. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hotel feasibility studies are critical in the determination of hotel construction, sales and refinancing. Discrepancies have been reported between forecasted results and actual operating results. The author, with funding provided by the Hilton corporation, examines whether such studies under- state or overstate occupancy, average rate, and net income.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Corporate executives closely monitor the accuracy of their hotels' occupancy fore- casts since important decisions are based upon these predictions. This study lists the criteria for selecting an appropriate error measure. It discusses several evaluation methods focusing on statistical significance tests and demonstrates the use of two adequate evaluation methods: Mincer- Zamowitz's efficiency test and Wilcoxon's Non-Parametric Matched-Pairs Signed- Ranks test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Correct specification of the simple location quotients in regionalizing the national direct requirements table is essential to the accuracy of regional input-output multipliers. The purpose of this research is to examine the relative accuracy of these multipliers when earnings, employment, number of establishments, and payroll data specify the simple location quotients. For each specification type, I derive a column of total output multipliers and a column of total income multipliers. These multipliers are based on the 1987 benchmark input-output accounts of the U.S. economy and 1988-1992 state of Florida data. Error sign tests, and Standardized Mean Absolute Deviation (SMAD) statistics indicate that the output multiplier estimates overestimate the output multipliers published by the Department of Commerce-Bureau of Economic Analysis (BEA) for the state of Florida. In contrast, the income multiplier estimates underestimate the BEA's income multipliers. For a given multiplier type, the Spearman-rank correlation analysis shows that the multiplier estimates and the BEA multipliers have statistically different rank ordering of row elements. The above tests also find no significant different differences, both in size and ranking distributions, among the vectors of multiplier estimates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Funding/Support and role of the sponsor: None.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Funding/Support and role of the sponsor: None.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To develop, evaluate and apply a novel high-resolution 3D remote dosimetry protocol for validation of MRI guided radiation therapy treatments (MRIdian® by ViewRay®). We demonstrate the first application of the protocol (including two small but required new correction terms) utilizing radiochromic 3D plastic PRESAGE® with optical-CT readout.

Methods: A detailed study of PRESAGE® dosimeters (2kg) was conducted to investigate the temporal and spatial stability of radiation induced optical density change (ΔOD) over 8 days. Temporal stability was investigated on 3 dosimeters irradiated with four equally-spaced square 6MV fields delivering doses between 10cGy and 300cGy. Doses were imaged (read-out) by optical-CT at multiple intervals. Spatial stability of ΔOD response was investigated on 3 other dosimeters irradiated uniformly with 15MV extended-SSD fields with doses of 15cGy, 30cGy and 60cGy. Temporal and spatial (radial) changes were investigated using CERR and MATLAB’s Curve Fitting Tool-box. A protocol was developed to extrapolate measured ΔOD readings at t=48hr (the typical shipment time in remote dosimetry) to time t=1hr.

Results: All dosimeters were observed to gradually darken with time (<5% per day). Consistent intra-batch sensitivity (0.0930±0.002 ΔOD/cm/Gy) and linearity (R2=0.9996) was observed at t=1hr. A small radial effect (<3%) was observed, attributed to curing thermodynamics during manufacture. The refined remote dosimetry protocol (including polynomial correction terms for temporal and spatial effects, CT and CR) was then applied to independent dosimeters irradiated with MR-IGRT treatments. Excellent line profile agreement and 3D-gamma results for 3%/3mm, 10% threshold were observed, with an average passing rate 96.5%± 3.43%.

Conclusion: A novel 3D remote dosimetry protocol is presented capable of validation of advanced radiation treatments (including MR-IGRT). The protocol uses 2kg radiochromic plastic dosimeters read-out by optical-CT within a week of treatment. The protocol requires small corrections for temporal and spatially-dependent behaviors observed between irradiation and readout.