978 resultados para Vegetal regulator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Occurrence and distribution of 12 natural and anthropic communities were mapped.-from English summary

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experiment was carried out in 1993/94, in Jaboticabal, São Paulo State, Brazil, to verify the efficiency of plant growth regulators on agronomic characteristics of cotton and as pest control technique. The experimental design was a complete randomized block with four replications and seven treatments: 1) control; 2) ethephon + cyclanilide (720 + 90 g/ha a.i.); 3) ethephon + cyclanilide (960 + 120 g/ha a.i.); 4) ethephon + cyclanilide (1200 + 150 g/ha a.i.); 5) ethephon (960 g/ha a.i.); 6) ethephon (1200 g/ha a.i.) and 7) cyclanilide 150 g/ha a.i.). Results suggest that plant growth regulators can reduce harvest time in 15 days, contributing significantly to decreased late-season squares and immature bolls that serve as feeding and oviposition sites to boll weevils and pink bollworm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new pre-regulator boost operating in the boundary area between the continuous and discontinuous conduction modes of the boost inductor current, where the switches and boost diode performing zero-current commutations during its turn-off, eliminating the disadvantages related to the reverse recovery losses and electromagnetic interference problems of the boost diode when operating in the continuous conduction mode. Additionally, the interleaving technique is applied in the power cell, providing a significant input current ripple reduction. It should be noticed that the main objective of this paper is to present a complete modeling for the converter operating in the critical conduction mode, allowing an improved design procedure for interleaved techniques with high input power factor, a complete dynamic analysis of the structure, and the possibility of implementing digital control techniques in closed loop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It was evaluated the energetic efficiency and operational parameters of a windrowing and prismatic baling, both from CASE NEW HOLLAND® operations in sugarcane vegetal residues (green leaves, dry leaves and tops) picked mechanically in green cane. The area belongs to COSTA PINTO MILL (COSAN® Group) which was harvested mechanically by combines in the State of Sao Paulo, Brazil. The geographic location of the area is: Latitude 22°40'30S, Longitude 47°36'38W and Altitude of 605m. The variety was RB 82-5336, planted in 1.40m row spacing, with 78t.ha-1 yield. The vegetal residues analysis obtained 69.93% of leaves, 21.44% of stalks fractions, 2.27% of tops and 6.36% of total strange matter. The vegetal residues values were: gross heat of 18.43MJ.kg-1, low heat of 17.00MJ.kg'1 and useful heat of 12.94MJ.kg-1. The vegetal residues average energetic potential was 342.48GJ.ha-1. The treatments were simple, double and triple windrowing. The use of the rake and prismatic baler to pick up the residues was viable. The simple windrowing treatment presented the best results: effective capacity of 83.06t.ha-1, fuel consumption of 0.18L.t -1 and 99.95% of positive energetic efficiency. The bales obtained in the treatment of triple windrowing presented the largest specific mass average of 221.11kg.m-3. The soil amount in the bales increased with successive windrowing. The baling operation in the triple windrowing treatment obtained better results, presenting the effective capacities of 20.29t.h -1 and 1.45ha.h-1 and fuel consumption of for baled in 1.37L.t-1. The high total energetic efficiency of 99.53% indicates that is technically viable the withdrawal of the vegetal residues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brazil produced in 2002/03 season 317.87×106tons of sugar cane stalks and 36.88×106tons of vegetal residues (green leaves, dry leaves and tops) in a planted area of 4.61×106 hectares (ha). These residues have a useful heat of 3,613.14Mcal.t-1. Currently most of this biomass is burned as a pre-harvest practice. The doubt persists in the system type that it must be adopted to pick up, load, transport and unload this biomass at the sugar mill boilers. This study analyzed 22 variables related to operational costs and physical characteristics of these residues in a field situation using a JOHN DEERE® 6850 forage harvester with two different treatments: T1 and T2 (two types of rakes) with 6 repetitions each one. The geographic location of the studied area that belongs to COSTA PINTO MILL (COSAN® Group) is: Latitude 22°40'30S and Longitude 47°36'38W. The adopted methodology was proposed by Ripoli et al. (2002). The obtained results at a 5% level of significance showed that both treatments did not differed significantly between them. Some of the results were, where EBP stands for Oil Equivalent Barrel: Windrowing (T1=US$0.17.EBP-1 and US$9.59.ha-1, T2=US$0.08.EBP-1 and US$4.27.ha-1); Pick up (T1=US$1.31.EBP-1 and US$44.29.ha-1, T2 =US$1.37.EBP-1 and US$48.36.ha-1); Transportation (T1=US$1.27.EBP-1 and US$14,30.ha -1, T2=US$1.33.EBP-1 and US$14,80.ha -1), Unloading at the sugar mill (T1=US$0.30.EBP-1 and US$3.39.ha-1, T2=US$0.32.EBP-1 and US$3.51.ha-1); Total (T1=US$3.05.EBP-1 and US$71.57.ha-1, T2=US$3.10.EBP-1 and US$70.94.ha-1). Confronting the obtained data with the ones in the bibliography, this system revealed itself more expensive than the baling system or the integral harvest system using combines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to analyze the sugar cane vegetal residues collection, as well as determining its energetic potential, using a rake and cylindrical baler, both from NEW HOLLAND® under two different windrowing process (simple and double). The field tests were carried out in an area that belongs to COSTA PINTO MILL (COSAN® Group) in the city of Piracicaba, Sao Paulo State, Brazil. The geographic location of the area is: Latitude 22°4030'S, Longitude 47°3633'W and altitude of 605m. From the trash analysis, before the baling, the following average results were obtained: 69.93% of leaves; 2.27% of stalks fractions; 21.44% of tops and 6.36% of total strange matter. The estimated residues yield was 27.01 tons.ha -1 with a gross heat of 18.43 MJ.kg-1, low heat of 17.01 MJ.kg-1, useful heat of 13.32 MJ.kg-1, average moisture of 20.76% and an energetic potential of 494,875.09 MJ.ha-1. In the windrowing operations (simple and double) the averages of the 5 out of 13 analyzed variable presented differences between them in a 1% level of significance in the Tukey Test. The averages comparison of the results for bale's specific mass and the effective capacities (ton.h-1) e (ha.h-1) had been significant at a 5% level in the Tukey Test. The comparisons of the averages for the results had been significant to 1% level. The strange matter averages of the bales did not differed between them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the analysis, design, simulation, and experimental results for a high frequency high Power-Factor (PF) AC (Alternate Current) voltage regulator, using a Sepic converter as power stage. The control technique employed to impose a sinusoidal input current waveform, with low Total Harmonic Distortion (THD), is the sinusoidal variable hysteresis control. The control technique was implemented in a FPGA (Field Programmable Gate Array) device, using a Hardware Description Language (VHDL). Through the use of the proposed control technique, the AC voltage regulator performs active power-factor correction, and low THD in the input current, for linear and non-linear loads, satisfying the requirements of the EEC61000-3-2 standards. Experimental results from an example prototype, designed for 300W of nominal output power, 50kHz (switching frequency), and 127Vrms of nominal input and output voltages, are presented in order to validate the proposed AC regulator. © 2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a three-phase power flow for electrical distribution systems considering different models of voltage regulators is presented. A voltage regulator (VR) is an equipment that maintains the voltage level in a predefined value in a distribution line in spite of the load variations within its nominal power. Three different types of connections are analyzed: 1) wye-connected regulators, 2) open delta-connected regulators and 3) closed delta-connected regulators. To calculate the power flow, the three-phase backward/forward sweep algorithm is used. The methodology is tested on the IEEE 34 bus distribution system. ©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the subject-matter of teaching immaterial issues like power system dynamics where the phenomena and events are not sense-perceptible. The dynamics of the power system are recognized as analogous to the dynamics of a simple mechanical pendulum taken into account the well-known classical model for the synchronous machine. It is shown that even for more sophisticated models including flux decay and Automatic Voltage Regulator the mechanical device can be taken as an analogous, since provided some considerations about variation and control of the pendulum length using certain control laws. The resulting mathematical model represents a mechanical system that can be built for use in laboratory teaching of power system dynamics. © 2010 Praise Worthy Prize S.r.l. - All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A theoretical model was developed in order to determine the optimal moment for substituting the sprayer and pressure regulator kit on a center pivot irrigation machine. The model is based on the hypothesis that pressure regulator and sprayer deterioration decrease irrigation uniformity. To compensate the deficit that happens at under irrigated areas, an increase on irrigation depth is required. The model considers: additional water consumption and energy costs, maintenance and labor costs, as well as yield losses associated with under or over irrigated areas. The sum of all these components is compared to buying and installing a new spray kit cost, allowing the farmer to decide the best moment to renovate the sprayer and pressure regulator kits on a center pivot irrigation machine based on economic criteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A theoretical model developed by the authors for determining the optimal moment to substitute sprayer and pressure regulator kit on a center pivot irrigating potatoes and beans has been applied. The methodology compares the sum of the costs due to additional consumption of water and energy, maintenance and labor, as well as yield losses associated to areas with deficit or over irrigation to the costs due to buy and install a new sprinkling set on the pivot. The results showed that for a reduction of 3.07% of the Hermann and Hein’s Uniformity Coefficient (UCh), the substitution of the sprinkling module on the pivot is justified when potatoes and beans are cultivated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of cover crops in the soil causes changes in soil attributes influencing in a series of hydro-physical processes, which also modify the ability of soil to support the many activities that it is intended. Thus, the objective of this study was to evaluate the effect of cover crops on physical attributes of the soil. For this, an experiment was carried out on a Typic Hapludox, Jaboticabal State, Brazil, using cover crops of millet, sunn hemp, jack bean, lab-lab and black velvet bean in no-tillage and fallow area (spontaneous vegetation). The characteristics evaluated were the bulk density, macroporosity, microporosity, total porosity, aggregate stability, penetration resistance and organic matter. The incorporation of cover crops has proved to be a beneficial practice for the physical attributes of the soil, allowing a greater aggregate stability compared to fallow in the depth of 0-0.05 m. All cover crops presented values of soil penetration resistance below the critical value of 2 MPa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study evaluated the efficacy of fluazuron (active ingredient of the acaricide Acatak®) and its effects on Rhipicephalus sanguineus nymphs fed on rabbits exposed to different doses of this insect growth regulator. Three different doses of fluazuron (20 mg/kg, 40 mg/kg, and 80 mg/kg) were applied on the back of hosts (via pour on), while distilled water was applied to the Control group. On the first day of treatment with fluazuron (24 h), hosts were artificially infested with R. sanguineus nymphs. Once fully engorged, nymphs were removed and placed in identified Petri dishes in Biochemical Oxygen Demand (BOD) incubator for 7 days. After this period, engorged nymphs were processed for ultramorphological analysis. The results revealed alterations in the ultramorphology of many chitinous structures (smaller hypostome and chelicerae, less sclerotized scutum, fewer sensilla, fewer pores, absence of grooves, marginal and cervical strips and festoons in the body, even the anal plaque was damaged) that play essential roles for the survivor of ticks and that can compromise the total or partial development of nymphs and emergence of adults after periodic molting. Our findings confirm the efficacy of fluazuron, a more specific and less aggressive chemical to the environment and human health, and that does not induce resistance, in nymphs of the tick R. sanguineus in artificially infested rabbits treated with this arthropod growth regulator (AGR), indicating that it could be used in the control of this stage of the biological cycle of the tick R. sanguineus. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)