969 resultados para Validation Measures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sectorization means dividing a whole into parts (sectors), a procedure that occurs in many contexts and applications, usually to achieve some goal or to facilitate an activity. The objective may be a better organization or simplification of a large problem into smaller sub-problems. Examples of applications are political districting and sales territory division. When designing/comparing sectors some characteristics such as contiguity, equilibrium and compactness are usually considered. This paper presents and describes new generic measures and proposes a new measure, desirability, connected with the idea of preference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sectorization means dividing a set of basic units into sectors or parts, a procedure that occurs in several contexts, such as political, health and school districting, social networks and sales territory or airspace assignment, to achieve some goal or to facilitate an activity. This presentation will focus on three main issues: Measures, a new approach to sectorization problems and an application in waste collection. When designing or comparing sectors different characteristics are usually taken into account. Some are commonly used, and they are related to the concepts of contiguity, equilibrium and compactness. These fundamental characteristics will be addressed, by defining new generic measures and by proposing a new measure, desirability, connected with the idea of preference. A new approach to sectorization inspired in Coulomb’s Law, which establishes a relation of force between electrically charged points, will be proposed. A charged point represents a small region with specific characteristics/values creating relations of attraction/repulsion with the others (two by two), proportional to the charges and inversely proportional to their distance. Finally, a real case about sectorization and vehicle routing in solid waste collection will be mentioned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este documento apresenta uma avaliação sobre o uso dos simuladores fisiológicos como padrão para avaliação metrológica dos esfigmomanómetros automáticos na estimação da pressão sanguínea pelo método não invasivo (PNI). O presente estudo procurou avaliar o enquadramento destes equipamentos com os procedimentos das normas e recomendações usadas para apreciação metrológica dos esfigmomanómetros digitais. No contexto da prática metrológica existente determinou-se a existência de uma oportunidade de melhoria nos processos relacionados. O trabalho procurou obter resposta a diversas questões, relacionando a medição da pressão pelo método não invasivo, com o uso dos simuladores fisiológicos, o contexto em que estes podem ser usados, as formas de simulação, as medições e os resultados, procurando a perspetiva metrológica como enquadramento. As recomendações existentes [1] [2] [3] [4] [5] [6] [7] [8], são muito claras nos procedimentos, validação e nos desvios permitidos para os monitores da tensão arterial (MTA), equipamento que permite a avaliação dos parâmetros fisiológicos do paciente, no entanto, quando se pretende avançar para outro domínio, como o do uso dos simuladores, em particular para a simulação da PNI, não existem recomendações ou normas tão claras, e não existe sobretudo um padrão de referência que imite a natureza dinâmica que caracteriza a pressão sanguínea. O trabalho procurou ainda estabelecer a ligação entre o método clássico de auscultação (o principio de determinação da PS), a técnica digital de medição e os simuladores, para uma melhor compreensão do que é a pressão sanguínea, e como relacionar a problemática da simulação e a de um padrão de referência. Neste trabalho estão ainda presentes abordagens a diversos tópicos, como as validações clínicas, acessórios, ou a metrologia e que influenciam no final os equipamentos e o contexto que se pretende avaliar. Os diversos equipamentos testados procuraram conter amostras diversificadas, quer para os MTA de uso profissional ou doméstico, assim como para os simuladores. A avaliação dos simuladores foi realizada contra um grupo de MTAs. Foi testada a influência na medição, causada pela mudança de acessórios, ou seja, nos resultados, merecendo consideração pela perspetiva metrológica. No resumo dos testes e do estudo sobre este tema, verificou-se que esta tipologia de equipamentos pode contribuir como complemento do processo de calibração típico (estático). Não constitui por si só um método alternativo, mas permitiu estimar possíveis limites de erro e desvio padrão a partir da observação dos resultados práticos, limites esses inferiores aos processos de validação clínica. Atendendo às particularidades, estimou-se como desvio aceitável um erro mais desvio padrão de 5 + 3 mmHg para o processo de simulação. Contudo considera-se ainda importante os testes adicionais em que o simulador permite, ao verificar as medidas de segurança implementadas no equipamento e a condição dos acessórios, que como verificado afetam os resultados. No entanto nem todos os simuladores se mostram adequados a este processo pelo que a qualidade da seleção do equipamento para este fim pode eventualmente reduzir ainda mais os possíveis limites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The index of microcirculatory resistance (IMR) enables/provides quantitative, invasive, and real-time assessment of coronary microcirculation status. AIMS: The primary aim of this study was to validate the assessment of IMR in a large animal model, and the secondary aim was to compare two doses of intracoronary papaverine, 5 and 10 mg, for induction of maximal hyperemia and its evolution over time. METHODS: Measurements of IMR were performed in eight pigs. Mean distal pressure (Pd) and mean transit time (Tmn) were measured at rest and at maximal hyperemia induced with intracoronary papaverine, 5 and 10 mg, and after 2, 5, 8 and 10 minutes. Disruption of the microcirculation was achieved by selective injection of 40-μm microspheres via a microcatheter in the left anterior descending artery. RESULTS: In each animal 14 IMR measurements were made. There were no differences between the two doses of papaverine regarding Pd response and IMR values - 11 ± 4.5 U with 5 mg and 10.6 ± 3 U with 10 mg (p=0.612). The evolution of IMR over time was also similar with the two doses, with significant differences from resting values disappearing after five minutes of intracoronary papaverine administration. IMR increased with disrupted microcirculation in all animals (41 ± 16 U, p=0.001). CONCLUSIONS: IMR provides invasive and real-time assessment of coronary microcirculation. Disruption of the microvascular bed is associated with a significant increase in IMR. A 5-mg dose of intracoronary papaverine is as effective as a 10-mg dose in inducing maximal hyperemia. After five minutes of papaverine administration there is no significant difference from resting hemodynamic status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION AND OBJECTIVES: Recurrent syncope has a significant impact on quality of life. The development of measurement scales to assess this impact that are easy to use in clinical settings is crucial. The objective of the present study is a preliminary validation of the Impact of Syncope on Quality of Life questionnaire for the Portuguese population. METHODS: The instrument underwent a process of translation, validation, analysis of cultural appropriateness and cognitive debriefing. A population of 39 patients with a history of recurrent syncope (>1 year) who underwent tilt testing, aged 52.1 ± 16.4 years (21-83), 43.5% male, most in active employment (n=18) or retired (n=13), constituted a convenience sample. The resulting Portuguese version is similar to the original, with 12 items in a single aggregate score, and underwent statistical validation, with assessment of reliability, validity and stability over time. RESULTS: With regard to reliability, the internal consistency of the scale is 0.9. Assessment of convergent and discriminant validity showed statistically significant results (p<0.01). Regarding stability over time, a test-retest of this instrument at six months after tilt testing with 22 patients of the sample who had not undergone any clinical intervention found no statistically significant changes in quality of life. CONCLUSIONS: The results indicate that this instrument is of value for assessing quality of life in patients with recurrent syncope in Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: New scores have been developed and validated in the US for in-hospital mortality risk stratification in patients undergoing coronary angioplasty: the National Cardiovascular Data Registry (NCDR) risk score and the Mayo Clinic Risk Score (MCRS). We sought to validate these scores in a European population with acute coronary syndrome (ACS) and to compare their predictive accuracy with that of the GRACE risk score. METHODS: In a single-center ACS registry of patients undergoing coronary angioplasty, we used the area under the receiver operating characteristic curve (AUC), a graphical representation of observed vs. expected mortality, and net reclassification improvement (NRI)/integrated discrimination improvement (IDI) analysis to compare the scores. RESULTS: A total of 2148 consecutive patients were included, mean age 63 years (SD 13), 74% male and 71% with ST-segment elevation ACS. In-hospital mortality was 4.5%. The GRACE score showed the best AUC (0.94, 95% CI 0.91-0.96) compared with NCDR (0.87, 95% CI 0.83-0.91, p=0.0003) and MCRS (0.85, 95% CI 0.81-0.90, p=0.0003). In model calibration analysis, GRACE showed the best predictive power. With GRACE, patients were more often correctly classified than with MCRS (NRI 78.7, 95% CI 59.6-97.7; IDI 0.136, 95% CI 0.073-0.199) or NCDR (NRI 79.2, 95% CI 60.2-98.2; IDI 0.148, 95% CI 0.087-0.209). CONCLUSION: The NCDR and Mayo Clinic risk scores are useful for risk stratification of in-hospital mortality in a European population of patients with ACS undergoing coronary angioplasty. However, the GRACE score is still to be preferred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to confer Master Degree in Chemical and Biochemical Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia e Gestão Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological surveillance activities were implemented in 1980 in Mambaí and Buritinópolis counties, Goiás State. Twenty years later the authors evaluated the impact of these vector control measures on Chagas' disease transmission, based on entomological indicators. Entomological investigation was conducted using the man-hour technique and covering all domiciles. In order to study vector food sources the stomach contents of triatomines were analyzed using the modified precipitins technique. Triatomines were shown to be present in 48 (71.6%) of the 67 locations. Peridomiciliary infestation rates in Mambaí and Buritinópolis were 8.7% and 12.1%, respectively, while intradomiciliary rates were 0.7% and 1.2%. Triatoma sordida was the species identified in 97.3% of all captured specimens. It was also the only species found to be naturally infected with Trypanosoma cruzi. Birds were the most frequent food source (45%) for Triatoma sordida. The most significant result was the complete absence of Triatoma infestans in the two counties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Contexto: O funcionamento tem sido reconhecido como um dos principais indicadores de resultados para avaliar se as pessoas beneficiam das intervenções destinadas a melhorar a sua saúde mental. O funcionamento refere-se à forma como um indivíduo consegue responder às suas tarefas e solicitações, dos seus familiares e da sua comunidade, de acordo com os requisitos do local e a cultura em que vive (eg, tarefa de cozinhar e limpar para as mulheres em algumas culturas ). O funcionamento é altamente dependente da cultura - por isso, tem sido recomendado o desenvolvimento de medidas de funcionamento específicas de cada cultura. Desenvolver localmente os instrumentos de medida evita problemas de adequação, associados com a adaptação de instrumentos ocidentais. Embora os instrumentos criados desta forma sejam específicos de um meio cultural, eles são simultaneamente "transculturais", no sentido em que cada um se refere às tarefas mais importantes para a população local . Esta abordagem mostrou-se útil para investigadores e agências de ajuda (eg, ONGs) que trabalham em países não-ocidentais . Este estudo descreve o trabalho da agência International Medical Corps (IMC) na criação e validação de um questionário de funcionamento específico nas dimensões cultura e gênero, no Líbano, destinado a avaliar eventuais melhorias em pessoas que receberam intervenções de para problemas de saúde mental, a nível dos cuidados primários de saúde. Método: O instrumento foi desenvolvido usando um método que é uma alternativa à abordagem existente de adaptação de instrumentos ocidentais a outras culturas e situações; esta abordagem é rápida e exequível, tendo já demonstrado ser útil no desenvolvimento de instrumentos válidos e fidedignos. Inicialmente, foi solicitado que as pessoas identificassem, de uma lista livre, as tarefas mais importantes para cuidar de si próprias, da sua família e da sua comunidade; as tarefas identificadas foram posteriormente usadas como base para um instrumento de avaliação de funcionamento culturalmente válido. A partir daqui, foram desenvolvidos questionários específicos da comunidade em questão, posteriormente testados no terreno nas vertentes da validade (de conteúdo, facial e de constructo) e da fiabilidade (teste-reste e inter-entrevistadores). Resultados. O estudo resultou na criação e validação de um questionário de funcionamento específico de cultura e gênero capaz de medir efectivamente a capacidade de execução de tarefas importantes do quotidiano,como parte da avaliação de resultados levada a cabo por profissionais da CSP previamente treinados na identificação, suporte e encaminhamento de pessoas com problemas de saúde mental no Líbano. Conclusão. Neste trabalho descreve-se o desenvolvimento de um questionário de funcionamento específico de cultura e gênero, orientado para a avaliação de resultados, num contexto mais lato de um sistema abrangente de avaliação e monitorização de um serviço comunitário. --------------ABSTRACT: Background. Functioning has been recognized as one of the most important key outcomes to assess whether people benefit from interventions aimed to improve their mental health. Functioning refers to how well na individual can complete the tasks and demands for themselves, their family, and their community which are required by them depending on the setting and the culture they live in (e.g. task of cooking and cleaning for women in some cultures). Functioning is highly dependent on culture. Therefore, it has been recommended to develop culture-specific measures of function. Developing instruments locally avoids the problems of limited local relevance and appropriateness associate with adapting western instruments. Although each instrument created in this way is culturally bound, they are “cross cultural” in the sense that each refers to the tasks most important to local people. This approach proves useful for both researchers and aid agencies working in non-western countries. This study describes International Medical Corps’ (IMC) work in Lebanon to create and validate a culture and gender specific functioning questionnaire to assess improvements in people who received treatment interventions for mental health problems at the primary health care (PHC) level. Method. The measure was developed using a method that is an alternative to the existing approach of adapting western function instruments to other cultures and situations; an approach which has been demonstrated as rapid, feasible and which can yield valid and reliable instruments. Function was assessed by first asking local people what tasks are important to care for themselves, their family and their community using free listing, then using these tasks as the basis for a culturally valid function assessment instrument. Community specific function questionnaires based on these tasks were then created, and field-tested for validity using content, face and construct validity methods, and also field tested for reliability using inter-rater and test retest reliability methods. Results. The study resulted in the creation and validation of a culture and gender specific functioning questionnaire that would effectively measure the ability to do tasks important to daily existence, as part of assessing client level outcomes where PHC providers were trained in the identification, management and referral of people with mental health problems in Lebanon. Conclusion. The paper describes a successful pilot for developing culture and gender specific functioning questionnaires that evaluate client level outcomes as part of a more comprehensive system for monitoring and evaluation of community based case management supports and services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia