995 resultados para UP-CONVERSION LUMINESCENCE
Resumo:
Previous Monte Carlo studies have investigated the multileaf collimator (MLC) contribution to the build-up region for fields in which the MLC leaves were fully blocking the openings defined by the collimation jaws. In the present work, we investigate the same effect but for symmetric and asymmetric MLC defined field sizes (2×2, 4×4, 10×10 and 3×7 cm2). A Varian 2100C/D accelerator with 120-leaf MLC is accurately modeled fora6MVphoton beam using the BEAMnrc/EGSnrc code. Our results indicate that particles scattered from accelerator head and MLC are responsible for the increase of about 7% on the surface dose when comparing 2×2 and 10×10 cm2 fields. We found that the MLC contribution to the total build-up dose is about 2% for the 2×2 cm2 field and less than 1% for the largest fields.
Resumo:
O óxido de polifenileno com a marca comercial PPO® é uma das resinas principais produzidas na SABIC IP e o ingrediente principal do plástico de engenharia com a marca registada, Noryl®. A equipa de tecnologia de processo de PPO® desenvolve uma série de novos produtos em reactores de pequena escala, tanto em Selkirk como em Bergen op Zoom. Para se efectuar uma transição rápida da escala laboratorial para a fábrica, é necessário um conhecimento completo do reactor. O objectivo deste projecto consiste em esboçar linhas gerais para o scale-up de novos produtos de PPO1, do laboratório para a escala industrial, baseado no estudo de um tipo de PPO, PPO 803. Este estudo pode ser dividido em duas fases. Numa primeira fase, as receitas e os perfis da reacção são comparados, de onde se retiram as primeiras conclusões. Posteriormente, com base nestas conclusões, é realizado um planeamento experimental. O estudo inicial sugeriu que a receita, a temperatura inicial do reactor e a velocidade do agitador poderiam influenciar o tempo da reacção bem como a queda da velocidade intrínseca do polímero (IV drop). As reacções experimentais mostraram que a receita é o principal factor que influencia, tanto o tempo de reacção, como a queda de viscosidade intrínseca. O tempo de reacção será tanto maior quanto menor a agitação devido à má dispersão do oxigénio na mistura. O uso de temperaturas iniciais elevadas conduz a uma queda maior da viscosidade intrínseca devido à desactivação do catalisador. O método experimental utilizado no laboratório de Bergen op Zoom é um bom exemplo, simulador, do procedimento utilizado na fábrica.
Resumo:
Mestrado em Auditoria
Resumo:
The scientific evidence supporting the management of the chronically ill in a positive psychological perspective in opposition to traditional pathological approach is scarce. This study examines issues associated with recovery of health status in heart failure, in particular hope, affection, and happiness. We use a longitudinal study of 128 symptomatic patients who after medical intervention reported improved quality of life and function at 3-month follow-up. We evaluated the contribution of happiness, hope and affection, individually and as a whole, in the quality of life and functionality of individuals with heart failure. Happiness (Subjective Happiness Scale), Hope (HOPE Scale), and affection (PANAS (positive and negative affect schedule)) were determined before medical intervention. Individually, we found that happiness is correlated with the quality of life and functionality, hope to self-efficacy dimension of the quality of life scale, positive affect to functionality and negative affect with symptoms dimension, quality of life dimension, and overall sum of the quality of life scale. Overall, we found that happiness has a unique contribution to the quality of life, except in self-efficacy dimension where hope takes this contribution and positive affect has a unique contribution to the functionality in this short-term follow-up. The results highlight the importance of positive variables to health outcomes for people with heart failure and should be considered in intervention programs for this syndrome.
Resumo:
In an age where Babel has turned into transcultural communication, an interlingual approach – i.e. in English and in French – to the translating process from German to Portuguese appeared pertinent. Aiming at a refinement of the translating competence, this process consists in contrasting different linguistic and literary strategies through an intercultural and multi-etymological perspective. Thus, we settled upon Heiner Müller‘s play Der Auftrag. Erinnerung an eine Revolution (1980), on which the composer Heiner Goebbels has based himself to textually and musically dramatize an excerpt, Der Mann im Farhstuhl / The Man in the Elevator. A transcription of such excerpt in its source language, German, as well as its translation into English (Carl Weber, 1984, Performing Arts Publications, New York) and French (Jean Jourdheuil, Heinz Schwarzinger, Editions Minuit, Paris) can be found in the booklet that accompanies the CD – edited in 1988 by ECD (München: Records GmbH). It should be emphasized that such a creation allows a framing of Müller‘s text into a musical scenography and, therefore, encourages an intersemiotic contrast. This experience enabled us to come up with a unique imagery of Müller‘s piece of writing, by means of its dramatic and musical conversion and, simultaneously, lead us to stretch our textual consciousness to a multitude of intra-, extra- and interlinguistic elements.
Resumo:
The current models are not simple enough to allow a quick estimation of the remediation time. This work reports the development of an easy and relatively rapid procedure for the forecasting of the remediation time using vapour extraction. Sandy soils contaminated with cyclohexane and prepared with different water contents were studied. The remediation times estimated through the mathematical fitting of experimental results were compared with those of real soils. The main objectives were: (i) to predict, through a simple mathematical fitting, the remediation time of soils with water contents different from those used in the experiments; (ii) to analyse the influence of soil water content on the: (ii1) remediation time; (ii2) remediation efficiency; and (ii3) distribution of contaminants in the different phases present into the soil matrix after the remediation process. For sandy soils with negligible contents of clay and natural organic matter, artificially contaminated with cyclohexane before vapour extraction, it was concluded that (i) if the soil water content belonged to the range considered in the experiments with the prepared soils, then the remediation time of real soils of similar characteristics could be successfully predicted, with relative differences not higher than 10%, through a simple mathematical fitting of experimental results; (ii) increasing soil water content from 0% to 6% had the following consequences: (ii1) increased remediation time (1.8–4.9 h, respectively); (ii2) decreased remediation efficiency (99–97%, respectively); and (ii3) decreased the amount of contaminant adsorbed onto the soil and in the non-aqueous liquid phase, thus increasing the amount of contaminant in the aqueous and gaseous phases.
Resumo:
This work reports a relatively rapid procedure for the forecasting of the remediation time (RT) of sandy soils contaminated with cyclohexane using vapour extraction. The RT estimated through the mathematical fitting of experimental results was compared with that of real soils. The main objectives were: (i) to predict the RT of soils with natural organic matter (NOM) and water contents different from those used in experiments; and (ii) to analyse the time and efficiency of remediation, and the distribution of contaminants into the soil matrix after the remediation process, according to the soil contents of: (ii1) NOM; and (ii2) water. For sandy soils with negligible clay contents, artificially contaminated with cyclohexane before vapour extraction, it was concluded that: (i) if the NOM and water contents belonged to the range of the prepared soils, the RT of real soils could be predicted with relative differences not higher than 12%; (ii1) the increase of NOM content from 0% to 7.5% increased the RT (1.8–13 h) and decreased the remediation efficiency (RE) (99–90%) and (ii2) the increase of soil water content from 0% to 6% increased the RT (1.8–4.9 h) and decreased the RE (99–97%). NOM increases the monolayer capacity leading to a higher sorption into the solid phase. Increasing of soil water content reduces the mass transfer coefficient between phases. Concluding, NOM and water contents influence negatively the remediation process, turning it less efficient and more time consuming, and consequently more expensive.
Resumo:
Soil vapor extraction (SVE) and bioremediation (BR) are two of the most common soil remediation technologies. Their application is widespread; however, both present limitations, namely related to the efficiencies of SVE on organic soils and to the remediation times of some BR processes. This work aimed to study the combination of these two technologies in order to verify the achievement of the legal clean-up goals in soil remediation projects involving seven different simulated soils separately contaminated with toluene and xylene. The remediations consisted of the application of SVE followed by biostimulation. The results show that the combination of these two technologies is effective and manages to achieve the clean-up goals imposed by the Spanish Legislation. Under the experimental conditions used in this work, SVE is sufficient for the remediation of soils, contaminated separately with toluene and xylene, with organic matter contents (OMC) below 4 %. In soils with higher OMC, the use of BR, as a complementary technology, and when the concentration of contaminant in the gas phase of the soil reaches values near 1 mg/L, allows the achievement of the clean-up goals. The OMC was a key parameter because it hindered SVE due to adsorption phenomena but enhanced the BR process because it acted as a microorganism and nutrient source.
Resumo:
This paper presents a micro power light energy harvesting system for indoor environments. Light energy is collected by amorphous silicon photovoltaic (a-Si:H PV) cells, processed by a switched capacitor (SC) voltage doubler circuit with maximum power point tracking (MPPT), and finally stored in a large capacitor. The MPPT fractional open circuit voltage (V-OC) technique is implemented by an asynchronous state machine (ASM) that creates and dynamically adjusts the clock frequency of the step-up SC circuit, matching the input impedance of the SC circuit to the maximum power point condition of the PV cells. The ASM has a separate local power supply to make it robust against load variations. In order to reduce the area occupied by the SC circuit, while maintaining an acceptable efficiency value, the SC circuit uses MOSFET capacitors with a charge sharing scheme for the bottom plate parasitic capacitors. The circuit occupies an area of 0.31 mm(2) in a 130 nm CMOS technology. The system was designed in order to work under realistic indoor light intensities. Experimental results show that the proposed system, using PV cells with an area of 14 cm(2), is capable of starting-up from a 0 V condition, with an irradiance of only 0.32 W/m(2). After starting-up, the system requires an irradiance of only 0.18 W/m(2) (18 mu W/cm(2)) to remain operating. The ASM circuit can operate correctly using a local power supply voltage of 453 mV, dissipating only 0.085 mu W. These values are, to the best of the authors' knowledge, the lowest reported in the literature. The maximum efficiency of the SC converter is 70.3 % for an input power of 48 mu W, which is comparable with reported values from circuits operating at similar power levels.
Resumo:
In this paper, a novel ROM-less RNS-to-binary converter is proposed, using a new balanced moduli set {22n-1, 22n + 1, 2n-3, 2n + 3} for n even. The proposed converter is implemented with a two stage ROM-less approach, which computes the value of X based only in arithmetic operations, without using lookup tables. Experimental results for 24 to 120 bits of Dynamic Range, show that the proposed converter structure allows a balanced system with 20% faster arithmetic channels regarding the related state of the art, while requiring similar area resources. This improvement in the channel's performance is enough to offset the higher conversion costs of the proposed converter. Furthermore, up to 20% better Power-Delay-Product efficiency metric can be achieved for the full RNS architecture using the proposed moduli set. © 2014 IEEE.
Resumo:
This paper presents a systemic modeling for a PV system integrated into an electric grid. The modeling includes models for a DC-DC boost converter and a DC-AC two-level inverter. Classical or fuzzy PI controllers with pulse width modulation by space vector modulation associated with sliding mode control is used for controlling the PV system and power factor control is introduced at the output of the system. Comprehensive performance simulation studies are carried out with the modeling of the DC-DC boost converter followed by a two-level power inverter in order to compare the performance with the experimental results obtained during in situ operation with three commercial inverters. Also, studies are carried out to assess the quality of the energy injected into the electric grid in terms of harmonic distortion. Finally, conclusions regarding the integration of the PV system into the electric grid are presented. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
OBJECTIVE To analyze the cases of tuberculosis and the impact of direct follow-up on the assessment of treatment outcomes.METHODS This open prospective cohort study evaluated 504 cases of tuberculosis reported in the Sistema de Informação de Agravos de Notificação (SINAN – Notifiable Diseases Information System) in Juiz de Fora, MG, Southeastern Brazil, between 2008 and 2009. The incidence of treatment outcomes was compared between a group of patients diagnosed with tuberculosis and directly followed up by monthly consultations during return visits (287) and a patient group for which the information was indirectly collected (217) through the city’s surveillance system. The Chi-square test was used to compare the percentages, with a significance level of 0.05. The relative risk (RR) was used to evaluate the differences in the incidence rate of each type of treatment outcome between the two groups.RESULTS Of the outcomes directly and indirectly evaluated, 18.5% and 3.2% corresponded to treatment default and 3.8% and 0.5% corresponded to treatment failure, respectively. The incidence of treatment default and failure was higher in the group with direct follow-up (p < 0.05) (RR = 5.72, 95%CI 2.65;12.34, and RR = 8.31, 95%CI 1.08;63.92, respectively).CONCLUSIONS A higher incidence of treatment default and failure was observed in the directly followed up group, and most of these cases were neglected by the disease reporting system. Therefore, effective measures are needed to improve the control of tuberculosis and data quality.
Resumo:
Dissertação apresentada para obtenção do grau de Doutor em Bioquímica, especialidade Bioquímica-Física, pela Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa
Resumo:
The article reports density measurements of dipropyl (DPA), dibutyl (DBA) and bis(2-ethylhexyl) (DEHA) adipates, using a vibrating U-tube densimeter, model DMA HP, from Anton Paar GmbH. The measurements were performed in the temperature range (293 to 373) K and at pressures up to about 68 MPa, except for DPA for which the upper limits were 363 K and 65 MPa, respectively. The density data for each liquid was correlated with the temperature and pressure using a modified Tait equation. The expanded uncertainty of the present density results is estimated as 0.2% at a 95% confidence level. No literature density data at pressures higher than 0.1 MPa could be found. DEHA literature data at atmospheric pressure agree with the correlation of the present measurements, in the corresponding temperature range, within +/- 0.11%. The isothermal compressibility and the isobaric thermal expansion were calculated by differentiation of the modified Tait correlation equation. These two parameters were also calculated for dimethyl adipate (DMA), from density data reported in a previous work. The uncertainties of isothermal compressibility and the isobaric thermal expansion are estimated to be less than +/- 1.7% and +/- 1.1%, respectively, at a 95% confidence level. Literature data of isothermal compressibility and isobaric thermal expansivity for DMA have an agreement within +/- 1% and +/- 2.4%, respectively, with results calculated in this work. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
OBJECTIVE To compare the effectiveness of two speech therapy interventions, vocal warm-up and breathing training, focusing on teachers’ voice quality.METHODS A single-blind, randomized, parallel clinical trial was conducted. The research included 31 20 to 60-year old teachers from a public school in Salvador, BA, Northeasatern Brazil, with minimum workloads of 20 hours a week, who have or have not reported having vocal alterations. The exclusion criteria were the following: being a smoker, excessive alcohol consumption, receiving additional speech therapy assistance while taking part in the study, being affected by upper respiratory tract infections, professional use of the voice in another activity, neurological disorders, and history of cardiopulmonary pathologies. The subjects were distributed through simple randomization in groups vocal warm-up (n = 14) and breathing training (n = 17). The teachers’ voice quality was subjectively evaluated through the Voice Handicap Index (Índice de Desvantagem Vocal, in the Brazilian version) and computerized voice analysis (average fundamental frequency, jitter, shimmer, noise, and glottal-to-noise excitation ratio) by speech therapists.RESULTS Before the interventions, the groups were similar regarding sociodemographic characteristics, teaching activities, and vocal quality. The variations before and after the intervention in self-assessment and acoustic voice indicators have not significantly differed between the groups. In the comparison between groups before and after the six-week interventions, significant reductions in the Voice Handicap Index of subjects in both groups were observed, as wells as reduced average fundamental frequencies in the vocal warm-up group and increased shimmer in the breathing training group. Subjects from the vocal warm-up group reported speaking more easily and having their voices more improved in a general way as compared to the breathing training group.CONCLUSIONS Both interventions were similar regarding their effects on the teachers’ voice quality. However, each contribution has individually contributed to improve the teachers’ voice quality, especially the vocal warm-up.TRIAL RECORD NCT02102399, “Vocal Warm-up and Respiratory Muscle Training in Teachers”.