986 resultados para Pressure support


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To determine the effects of low-dose transdermal hormone therapy (HT) on systolic (SBP) and diastolic (DBP) blood pressure (BP) evaluated by 24-h ambulatory blood pressure monitoring (ABPM) in hypertensive postmenopausal women. Methods The study was conducted on 24 hypertensive postmenopausal women aged, on average, 54 years and under treatment with enalapril maleate (10-20 mg/day) combined or not with hydrochlorothiazide (25 mg/day). Thirteen women used a transdermal adhesive containing estradiol and norethisterone (25 and 125 mu g active substance/day, respectively) and 11 did not receive HT. ABPM, lipid profile, and climacteric symptoms were evaluated before and 3 and 6 months after treatment. Results After 3 and 6 months of follow-up, there was a statistically significant reduction of the Blatt-Kupperman menopausal index in the treated group (19.6 +/- 8.3 vs. 9.6 +/- 5.9 vs. 9.7 +/- 7.0; P=0.01). No significant difference in any of the ABPM variables (areas under the systolic and diastolic curves, mean SBP and DBP, SBP and DBP loads and wakefulness-sleep variation) or in the lipid profile was observed between or within groups at the three time points studied. Conclusion Low-dose transdermal HT administered for 6 months was effective in improving climacteric symptoms and did not change BP values or circadian pattern in postmenopausal women with mild-to-moderate arterial hypertension taking antihypertensive medications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the intra-and inter-rater reliability of pressure pain threshold (PPT) and manual palpation (MP) of orofacial structures in symptomatic and symptom-free children for temporomandibular disorders (TMD). Fourteen children reporting pain in masticatory muscles or the temporomandibular joint and 16 symptom-free children were randomly assessed on three different occasions: by rater-1 in the first and third session and by rater-2 in the second session. The trained raters applied algometry and MP as recommended by the Research Diagnostic Criteria for TMD. Intraclass correlation coefficients and the Kappa statistic were used to assess the levels of reliability of PPT and MP, respectively. Excellent intra-and inter-rater reliability levels were observed for PPT values at most of the examined sites for symptom-free children and excellent and moderate reliability levels for children reporting pain. For MP, moderate and poor intra-rater and inter-rater reliability levels were observed for most sites in both groups. Algometry showed higher reliability levels for both groups of children and is recommended for pain assessment in children in association with MP. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantitatively evaluate changes induced by the application of a femoral blood-pressure cuff (BPC) on run-off magnetic resonance angiography (MRA). which is a method generally previously proposed to reduce venous contamination in the leg. Materials and Methods: This study was Health Insurance Portability and Accountability Act (HIPAA)- and Institutional Review Board (IRB)-compliant, We used time-resolved gradient-echo gadolinium (Gd)-enhanced MRA to measure BPC effects on arterial, venous, and soft-tissue enhancement. Seven healthy volunteers (six men) were studied with the BPC applied at the mid-femoral level unilaterally using a 1.5T MR system after intravenous injection of Gd-BOPTA. Different statistical tools were used such as the Wilcoxon signed rank test and a cubic smoothing spline fit. Results: We found that BPC application induces delayed venous filling (as previously described), but also induces significant decreases in arterial inflow, arterial enhancement, vascular-soft tissue contrast, and delayed peak enhancement (which have not been previously measured). Conclusion: The potential benefits from using a BPC for run-off MRA must be balanced against the potential pitfalls, elucidated by our findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted in one kidney, one clip (1K1C) Goldblatt hypertensive rats to evaluate vascular and cardiac autonomic control using different approaches: 1) evaluation of the autonomic modulation of heart rate (HR) and systolic arterial pressure (SAP) by means of autoregressive power spectral analysis 2) assessment of the cardiac baroreflex sensitivity; and 3) double blockade with methylatropine and propranolol. The 1K1C group developed hypertension and tachycardia. The 1K1C group also presented reduction in variance as well as in LF (0.23 +/- 0.1 vs. 1.32 +/- 0.2 ms(2)) and HF (6.6 +/- 0.49 vs. 15.1 +/- 0.61 ms(2)) oscillations of pulse interval. Autoregressive spectral analysis of SAP showed that 1K1C rats had an increase in variance and LF band (13.3 +/- 2.7 vs. 7.4 +/- 1.01 mmHg(2)) in comparison with the sham group. The baroreflex gain was attenuated in the hypertensive 1K1C (- 1.83 +/- 0.05 bpm/mmHg) rats in comparison with normotensive sham (-3.23 +/- 0.06 bpm/MmHg) rats. The autonomic blockade caused an increase in the intrinsic HR and sympathetic predominance on the basal HR of 1K1C rats. Overall, these data indicate that the tachycardia observed in the 1K1C group may be attributed to intrinsic cardiac mechanisms (increased intrinsic heart rate) and to a shift in the sympathovagal balance towards cardiac sympathetic over-activity and vagal suppression associated to depressed baroreflex sensitivity. Finally, the increase in the LF components of SAP also suggests an increase in sympathetic activity to peripheral vessels. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the inter-rater reliability of the modified Oxford Grading Scale and the Peritron manometer. Design All participants were evaluated twice, first by one examiner and 30 days later by a second examiner. Measurements of vaginal squeeze pressure were compared with the results from the palpation test. Participants Nineteen women with a mean age of 23.7 years (range 21 to 28 years). Results Inter-rater reliability for vaginal palpation was fair (kappa = 0.33, 95% confidence interval 0.09 to 0.57). Using the Peritron manometer, the difference between examiners was less than 10 cmH(2)O in 11 of the 19 (58%) cases. The palpation test did not differentiate between weak, moderate, good and strong muscle contractions. This study found fair inter-rater reliability for the modified Oxford Grading Scale and moderate inter-rater reliability for the Peritron manometer. Conclusions The inter-rater reliability of vaginal squeeze pressure measurement using the Peritron manometer is acceptable and can be used in re-evaluations performed by different examiners in clinical practice. However, for research purposes, the ideal situation would be for a single examiner to assess and re-assess the subject. Vaginal palpation is important in the clinical assessment of correctness of a pelvic floor muscle contraction, but this study does not support the use of the modified Oxford Grading Scale as a reliable and valid method to measure and differentiate pelvic floor muscle strength. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypertension induces vascular alterations that are associated with up-regulation of matrix metalloproteinases (MMPs). While these alterations may be blunted by doxycycline, a non-selective MMPs inhibitor, no previous study has examined the effects of different doses of doxycycline on these alterations. This is important because doxycycline has been used at sub-antimicrobial doses, and the use of lower doses may prevent the emergence of antibiotic-resistant microorganisms. We studied the effects of doxycycline at 3, 10 and 30 mg/kg per day on the vascular alterations found in the rat two kidneyone clip (2K1C) hypertension (n = 20 rats/group). Systolic blood pressure (SBP) was monitored during 4 weeks of treatment. We assessed endothelium-dependent and independent relaxations. Quantitative morphometry of structural changes in the aortic wall was studied, and aortic MMP-2 levels/proteolytic activity were determined by gelatin and in situ zymography, respectively. All treatments attenuated the increases in SBP in hypertensive rats (195.4 +/- 3.9 versus 177.2 +/- 6.2, 176.3 +/- 4.5, and 173 +/- 5.1 mmHg in 2K1C hypertensive rats treated with vehicle, or doxycycline at 3, 10, 30 mg/kg per day, respectively (all p < 0.01). However, only the highest dose prevented 2K1C-induced reduction in endothelium-dependent vasorelaxation (p < 0.05), vascular hypertrophy and increases in MMP-2 levels (all p < 0.05). In conclusion, our results suggest that relatively lower doses of doxycycline do not attenuate the vascular alterations found in the 2K1C hypertension model, and only the highest dose of doxycycline affects MMPs and vascular structure. Our results support the idea that the effects of doxycycline on MMP-2 and vascular structure are pressure independent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine whether age influences the concordance between different methods of blood pressure (BP) measurement and ambulatory BP monitoring (ABPM) in hypertensive subjects. We studied two groups: I, individuals younger than 50 years (n = 57), and II, individuals aged 60 years or older (n = 55). They were submitted to the performance of one ABPM, office BP measurements, home BP monitoring (HBPM), and BP measurements at a public health center (PHCBP). Student`s t-test, Fisher`s test and Lin coefficient were calculated. For Group II, systolic and diastolic pressures measured by HBPM were higher than by day ABPM (p < 0.01). The concordance between day ABPM and the other methods was lower for Group II than for Group I. There was a good concordance between systolic day ABPM and office BP, and between systolic ABPM and PHCBP only for Group I (Lin coefficient = 0.71 and 0.73). Group II reported better sleep quality after ABPM (p < 0.05). Considering 24-h ABPM, 52.6% of Group I and 29% of Group II were controlled (p < 0.01). Concluding, there was worse concordance between different methods of BP measurements and day ABPM in the older group, which had lower hypertension control rate and better tolerance of ABPM. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work provides experimental phase diagram of mitotane, a drug used in the chemotherapy treatment of adrenocortical carcinoma, in compressed and/or supercritical CO(2). The synthetic-static method in a high-pressure variable-volume view cell coupled with a transmitted-light intensity probe was used to measure the solid-fluid (SF) equilibrium data. The phase equilibrium experiments were determined in temperature ranging from (298.2 to 333.1) K and pressure up to 22 MPa. Peng-Robinson equation of state (PR-EoS) with classical mixing rule was used to correlate the experimental data. Excellent agreement was found between experimental and calculated values. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Microalbuminuria and hypertension have long been associated with a guarded prognosis in human patients with a variety of diseases. In veterinary medicine, tests for microalbuminuria have been used for detecting early kidney damage, but there is little information regarding its association with high blood pressure in dogs with chronic kidney disease (CKD). Objective The objective of this study was to evaluate albuminuria and its association with arterial hypertension in dogs with CKD. Methods Urinary albumin:creatinine (UAC) ratio, urinary protein:creatinine (UPC) ratio, and systolic blood pressure were determined in 39 clinically healthy dogs and 40 dogs with CKD. Results UAC in dogs with CKD (range, 0.002-7.99; median, 0.38) was statistically different from that of control dogs (range, 0.0005-0.01; median, 0.002). Microalbuminuria (UAC 0.03-0.3) and macroalbuminuria (UAC > 0.3) were detected in 32.5% and 50% of dogs with CKD, respectively. Sixty percent (24/40) of dogs with CKD had systolic pressure >= 180 mmHg; in these dogs, UAC ratio (range, 0.006-7.99; median, 1.72) was significantly higher than in dogs with CKD and systolic pressure < 180 mmHg (range, 0.002-4.83; median, 0.10). Of hypertensive dogs with CKD, those with UPC > 1.0 usually had macroalbuminuria, those with UPC 0.5-1.0 usually had microalbuminuria, and those with UPC < 0.5 usually lacked albuminuria. Conclusions UAC ratio was higher in hypertensive than in normotensive dogs with CKD. Tests designed to detect microalbuminuria may be useful for hypertensive dogs with CKD and a UPC < 1.0 to detect the onset and magnitude of albuminuria. Once macroalbuminuria is overt, the UPC ratio itself can be used for the same purpose.