981 resultados para Portable.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Formic acid, the simplest carboxylic acid, is found in nature or can be easily synthesized in the laboratory (major by-product of some second generation biorefinery processes); it is also an important chemical due to its myriad applications in pharmaceuticals and industry. In recent years, formic acid has been used as an important fuel either without reformation (in direct formic acid fuel cells, DFAFCs) or with reformation (as a potential chemical hydrogen storage material). Owing to the better efficiency of DFAFCs compared to several other PEMFCs and reversible hydrogen storage systems, formic acid could serve as one of the better fuels for portable devices, vehicles and other energy-related applications in the future. This perspective is focused on recent developments in the use of formic acid as a reversible source for hydrogen storage. Recent developments in this direction will likely give access to a variety of low-cost and highly efficient rechargeable hydrogen fuel cells within the next few years by the use of suitable homogeneous metal complex/heterogeneous metal nanoparticle-based catalysts under ambient reaction conditions. The production of formic acid from atmospheric CO2 (a greenhouse gas) will decrease the CO2 content and may be helpful in reducing global warming.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article is aimed to delineate groundwater sources in Holocene deposits area in the Gulf of Mannar Coast from Southern India. For this purpose 2-D electrical resistivity tomography (ERT), hydrochemical and granulomerical studies were carried out and integrated to identify hydrogeological structures and portable groundwater resource in shallow depths which in general appears in the coastal tracts. The 2-D ERT was used to determine the two-dimensional subsurface geological formations by multicore cable with Wenner array. Low resistivity of 1-5 Omega m for saline water appeared due to calcite at the depth of about 5 m below the ground level (bgl). Sea water intrusion was observed around the maximum resistivity as 5 Omega m at the 8 m depth, bgl in the calcite environs, but the calcareous sandstone layer shows around 15-64 Omega m at the 6 m depth, bgl. The hydrochemical variation of TDS, HCO3-, Cl-, Na+, K+, Ca2+, and Mg2+ concentrations was observed for the saline and sea water intrusion in the groundwater system. The granulometic analysis shows that the study area was under the sea between 5400 and 3000 year ago. The events of ice melting an unnatural ice-stone rain/hail among 5000-4000 years ago resulted in the inundation of sea over the area and deposits of late Holocene marine transgression formation up to Puthukottai quartzite region for a stretch of around 17 km.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Controlled breakup of droplets using heat or acoustics is pivotal in applications such as pharmaceutics, nanoparticle production, and combustion. In the current work we have identified distinct thermal acoustics-induced deformation regimes (ligaments and bubbles) and breakup dynamics in externally heated acoustically levitated bicomponent (benzene-dodecane) droplets with a wide variation in volatility of the two components (benzene is significantly more volatile than dodecane). We showcase the physical mechanism and universal behavior of droplet surface caving in leading to the inception and growth of ligaments. The caving of the top surface is governed by a balance between the acoustic pressure field and the restrictive surface tension of the droplet. The universal collapse of caving profiles for different benzene concentration (<70% by volume) is shown by using an appropriate time scale obtained from force balance. Continuous caving leads to the formation of a liquid membrane-type structure which undergoes radial extension due to inertia gained during the precursor phase. The membrane subsequently closes at the rim and the kinetic energy leads to ligament formation and growth. Subsequent ligament breakup is primarily Rayleigh-Plateau type. The breakup mode shifts to diffusional entrapment-induced boiling with an increase in concentration of the volatile component (benzene >70% by volume). The findings are portable to any similar bicomponent systems with differential volatility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The 30,000 km2 province of Luristan is situated in western Iran and encompasses the upper valleys of the Zagros Mountains. Even today, local tribesmen inhabit Luristan with their settlement patterns similar to ancient times. Several scientific excavations in the Luristan region have uncovered evidence that this particular region was a major attraction for human settlements from the Paleolithic era onwards. In Ancient Iran, the existence of rich mines together with discoveries made by innovative and inventive artisans spurred the growth of the metalworking culture as an art and a skill among early human communities in Ancient Iran. The art of Luristan can be described as the art of nomadic herdsmen and horsemen with an emphasis on the crafting of small, easily portable objects, among these a number of bronze daggers, swords and other weapons. Throughout its history, Luristan was never an ethnic or political entity because Luristan has been occupied by various tribes and races, throughout its history. Next to Elamites, other tribes who inhabited Luristan were the Hurrians, Lullubians, Kutians, and Kassites. As local tribesmen of Luristan were illiterate, information about their history can only be partially reconstructed from the literature of their southern neighbors: the Elamites and Babylonians. Luristan smiths made weapons for both civilizations. The region was later invaded by Assyrians and finally the Iranians settled the area and absorbed the local tribes. Following an accidental find by the local inhabitants in Luristan in 1928 CE, a number of unlawful diggings reveal a number of metal objects made of bronze and iron that showed a high level of craftsmanship. These objects were offered for sale on the art market with fancy names to hide their origin. The subsequent scientific excavations several decades after the initial discovery provided fascinating information about the culture of Luristan. The metalworking art of Luristan spans a time period from the third millennium BC to the Iron Age. The artifacts from Luristan seem to possess many unique and distinctive qualities, and are especially noteworthy for the apparently endless, intricate diversity and detail that they characteristically depict. The bronze artifacts found in or attributed to Luristan can be each be classed under five separate heads: a) arms and armor, including swords, dirks, daggers, axes, mace heads, spearheads, shields, quiver plaques, protective bronze girdles, helmets; b) implements related to horsemanship, including decorative or ornamental objects for horses as well as bits and snaffles; c) items for personal adornment and hygiene, including anklets, bangles, bracelets, finger rings, earrings and tweezers; d) ceremonial and ritual objects, including talismans, idols, pins, anthropomorphic and zoomorphic figurines; and e) utilitarian objects comprising various vessels and tools, including beakers, bowls and jugs. The scope of this article is limited to a discussion of the bronze and iron weapons made in Luristan. The techniques used for making bronze weapons in Luristan included: casting with open molds, casting with close molds, and casting with lost wax process. For metal sheets used for quiver plaques and bronze protective belts, the hammering technique was used. Edged weapons made in Luristan can be classified into: a) daggers, dirks, and swords with tangs; b) daggers, dirks, and swords with flanges; and c) daggers, dirks, and swords with cast-on hilts. Next to bronze, iron was also used for making weapons such as the characteristic weapon from this area, the iron mask sword.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A portable mat for measuring the dynamic tire forces of commercial vehicles is described. The mat is 56 m long and 13 mm thick and has 141 capacitative strip sensors spaced at 0.4-m intervals. The accuracy of the mat for measuring dynamic tire forces generated by heavy commercial vehicles is assessed using an instrumented vehicle. The spatial repeatability of dynamic wheel loads generated by 14 uninstrumented articulated vehicles is investigated, and it is concluded that approximately half of the vehicles tested are likely to contribute to a repeatable pattern of road loading.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES] Información sobre este proyecto ha servido de base a los siguientes artículos:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurate and fast decoding of speech imagery from electroencephalographic (EEG) data could serve as a basis for a new generation of brain computer interfaces (BCIs), more portable and easier to use. However, decoding of speech imagery from EEG is a hard problem due to many factors. In this paper we focus on the analysis of the classification step of speech imagery decoding for a three-class vowel speech imagery recognition problem. We empirically show that different classification subtasks may require different classifiers for accurately decoding and obtain a classification accuracy that improves the best results previously published. We further investigate the relationship between the classifiers and different sets of features selected by the common spatial patterns method. Our results indicate that further improvement on BCIs based on speech imagery could be achieved by carefully selecting an appropriate combination of classifiers for the subtasks involved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For monitoring of the engine power of fishing vessels permitted for fishery in the plaice box with engine power of 300 HP or less at sea three different portable power measurement systems are developed and tested. A system measuring the twist of the propeller shaft by two divisible gearwheels mounted on the shaft worked well at shafts with roller bearing at both sides of the measured interval of 100–300 mm length. Only at a very few fishing vessels this system is applicable and therefore for monitoring purposes not suitable. The application of a commercial available system measuring the stress at the surface of the shaft was simplified for application by non experts. The torque is measured by strain gauges. The calibration of the system, measuring and recording of the power is done by a PC automatically. A small polished facet on the shaft protected against oxidation is needed for easy and quick application. In this case the system can be used by technical personnel of supervision boats for monitoring of the engine power at sea in a short time. A third power measurement system determinates the torque by measuring the displacement of two supports clamped on the shaft at a distance of 100 mm. The displacement is measured by a micrometer gauge mounted on one of the supports. Readout of the rotating gauge display is possible taking advantage of stroboscopic effect. The system needs no conditioning of the shaft and can be used by non technicians. The development is not finished until now and some additional investigations and tests are required. Additional measures for monitoring of the power on fishing vessels by self recording power measurement systems and sealed fuel racks with limited injection are reported and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Castellano: A lo largo de este proyecto se ha desarrollado un sistema de bajo coste para la tomade electrocardiogramas y posterior visualización de los mismos en un dispositivo Android. Además se ha creado un módulo inteligente capaz de realizar un diagnóstico de manera automática y razonada sobre los datos recogidos. El proyecto se ha realizado principalmente sobre tecnologías abiertas: Arduino como componente central del sistema electrónico, Android para visualizar datos en una plataforma móvil y CLIPS como motor sobre el cual se ha desarrollado el sistema experto que realiza el diagnóstico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Light microscopy has been one of the most common tools in biological research, because of its high resolution and non-invasive nature of the light. Due to its high sensitivity and specificity, fluorescence is one of the most important readout modes of light microscopy. This thesis presents two new fluorescence microscopic imaging techniques: fluorescence optofluidic microscopy and fluorescent Talbot microscopy. The designs of the two systems are fundamentally different from conventional microscopy, which makes compact and portable devices possible. The components of the devices are suitable for mass-production, making the microscopic imaging system more affordable for biological research and clinical diagnostics.

Fluorescence optofluidic microscopy (FOFM) is capable of imaging fluorescent samples in fluid media. The FOFM employs an array of Fresnel zone plates (FZP) to generate an array of focused light spots within a microfluidic channel. As a sample flows through the channel and across the array of focused light spots, a filter-coated CMOS sensor collects the fluorescence emissions. The collected data can then be processed to render a fluorescence microscopic image. The resolution, which is determined by the focused light spot size, is experimentally measured to be 0.65 μm.

Fluorescence Talbot microscopy (FTM) is a fluorescence chip-scale microscopy technique that enables large field-of-view (FOV) and high-resolution imaging. The FTM method utilizes the Talbot effect to project a grid of focused excitation light spots onto the sample. The sample is placed on a filter-coated CMOS sensor chip. The fluorescence emissions associated with each focal spot are collected by the sensor chip and are composed into a sparsely sampled fluorescence image. By raster scanning the Talbot focal spot grid across the sample and collecting a sequence of sparse images, a filled-in high-resolution fluorescence image can be reconstructed. In contrast to a conventional microscope, a collection efficiency, resolution, and FOV are not tied to each other for this technique. The FOV of FTM is directly scalable. Our FTM prototype has demonstrated a resolution of 1.2 μm, and the collection efficiency equivalent to a conventional microscope objective with a 0.70 N.A. The FOV is 3.9 mm × 3.5 mm, which is 100 times larger than that of a 20X/0.40 N.A. conventional microscope objective. Due to its large FOV, high collection efficiency, compactness, and its potential for integration with other on-chip devices, FTM is suitable for diverse applications, such as point-of-care diagnostics, large-scale functional screens, and long-term automated imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Humans are able of distinguishing more than 5000 visual categories even in complex environments using a variety of different visual systems all working in tandem. We seem to be capable of distinguishing thousands of different odors as well. In the machine learning community, many commonly used multi-class classifiers do not scale well to such large numbers of categories. This thesis demonstrates a method of automatically creating application-specific taxonomies to aid in scaling classification algorithms to more than 100 cate- gories using both visual and olfactory data. The visual data consists of images collected online and pollen slides scanned under a microscope. The olfactory data was acquired by constructing a small portable sniffing apparatus which draws air over 10 carbon black polymer composite sensors. We investigate performance when classifying 256 visual categories, 8 or more species of pollen and 130 olfactory categories sampled from common household items and a standardized scratch-and-sniff test. Taxonomies are employed in a divide-and-conquer classification framework which improves classification time while allowing the end user to trade performance for specificity as needed. Before classification can even take place, the pollen counter and electronic nose must filter out a high volume of background “clutter” to detect the categories of interest. In the case of pollen this is done with an efficient cascade of classifiers that rule out most non-pollen before invoking slower multi-class classifiers. In the case of the electronic nose, much of the extraneous noise encountered in outdoor environments can be filtered using a sniffing strategy which preferentially samples the visensor response at frequencies that are relatively immune to background contributions from ambient water vapor. This combination of efficient background rejection with scalable classification algorithms is tested in detail for three separate projects: 1) the Caltech-256 Image Dataset, 2) the Caltech Automated Pollen Identification and Counting System (CAPICS) and 3) a portable electronic nose specially constructed for outdoor use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents the development of chip-based technology for informative in vitro cancer diagnostics. In the first part of this thesis, I will present my contribution in the development of a technology called “Nucleic Acid Cell Sorting (NACS)”, based on microarrays composed of nucleic acid encoded peptide major histocompatibility complexes (p/MHC), and the experimental and theoretical methods to detect and analyze secreted proteins from single or few cells.

Secondly, a novel portable platform for imaging of cellular metabolism with radio probes is presented. A microfluidic chip, so called “Radiopharmaceutical Imaging Chip” (RIMChip), combined with a beta-particle imaging camera, is developed to visualize the uptake of radio probes in a small number of cells. Due to its sophisticated design, RIMChip allows robust and user-friendly execution of sensitive and quantitative radio assays. The performance of this platform is validated with adherent and suspension cancer cell lines. This platform is then applied to study the metabolic response of cancer cells under the treatment of drugs. Both cases of mouse lymphoma and human glioblastoma cell lines, the metabolic responses to the drug exposures are observed within a short time (~ 1 hour), and are correlated with the arrest of cell-cycle, or with changes in receptor tyrosine kinase signaling.

The last parts of this thesis present summaries of ongoing projects: development of a new agent as an in vivo imaging probe for c-MET, and quantitative monitoring of glycolytic metabolism of primary glioblastoma cells. To develop a new agent for c-MET imaging, the one-bead-one-compound combinatorial library method is used, coupled with iterative screening. The performance of the agent is quantitatively validated with cell-based fluorescent assays. In the case of monitoring the metabolism of primary glioblastoma cell, by RIMChip, cells were sorting according to their expression levels of oncoprotein, or were treated with different kinds of drugs to study the metabolic heterogeneity of cancer cells or metabolic response of glioblastoma cells to drug treatments, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optical microscopy is an essential tool in biological science and one of the gold standards for medical examinations. Miniaturization of microscopes can be a crucial stepping stone towards realizing compact, cost-effective and portable platforms for biomedical research and healthcare. This thesis reports on implementations of bright-field and fluorescence chip-scale microscopes for a variety of biological imaging applications. The term “chip-scale microscopy” refers to lensless imaging techniques realized in the form of mass-producible semiconductor devices, which transforms the fundamental design of optical microscopes.

Our strategy for chip-scale microscopy involves utilization of low-cost Complementary metal Oxide Semiconductor (CMOS) image sensors, computational image processing and micro-fabricated structural components. First, the sub-pixel resolving optofluidic microscope (SROFM), will be presented, which combines microfluidics and pixel super-resolution image reconstruction to perform high-throughput imaging of fluidic samples, such as blood cells. We discuss design parameters and construction of the device, as well as the resulting images and the resolution of the device, which was 0.66 µm at the highest acuity. The potential applications of SROFM for clinical diagnosis of malaria in the resource-limited settings is discussed.

Next, the implementations of ePetri, a self-imaging Petri dish platform with microscopy resolution, are presented. Here, we simply place the sample of interest on the surface of the image sensor and capture the direct shadow images under the illumination. By taking advantage of the inherent motion of the microorganisms, we achieve high resolution (~1 µm) imaging and long term culture of motile microorganisms over ultra large field-of-view (5.7 mm × 4.4 mm) in a specialized ePetri platform. We apply the pixel super-resolution reconstruction to a set of low-resolution shadow images of the microorganisms as they move across the sensing area of an image sensor chip and render an improved resolution image. We perform longitudinal study of Euglena gracilis cultured in an ePetri platform and image based analysis on the motion and morphology of the cells. The ePetri device for imaging non-motile cells are also demonstrated, by using the sweeping illumination of a light emitting diode (LED) matrix for pixel super-resolution reconstruction of sub-pixel shifted shadow images. Using this prototype device, we demonstrate the detection of waterborne parasites for the effective diagnosis of enteric parasite infection in resource-limited settings.

Then, we demonstrate the adaptation of a smartphone’s camera to function as a compact lensless microscope, which uses ambient illumination as its light source and does not require the incorporation of a dedicated light source. The method is also based on the image reconstruction with sweeping illumination technique, where the sequence of images are captured while the user is manually tilting the device around any ambient light source, such as the sun or a lamp. Image acquisition and reconstruction is performed on the device using a custom-built android application, constructing a stand-alone imaging device for field applications. We discuss the construction of the device using a commercial smartphone and demonstrate the imaging capabilities of our system.

Finally, we report on the implementation of fluorescence chip-scale microscope, based on a silo-filter structure fabricated on the pixel array of a CMOS image sensor. The extruded pixel design with metal walls between neighboring pixels successfully guides fluorescence emission through the thick absorptive filter to the photodiode layer of a pixel. Our silo-filter CMOS image sensor prototype achieves 13-µm resolution for fluorescence imaging over a wide field-of-view (4.8 mm × 4.4 mm). Here, we demonstrate bright-field and fluorescence longitudinal imaging of living cells in a compact, low-cost configuration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The specific high energy and power capacities of rechargeable lithium metal (Li0) batteries are ideally suited to portable devices and are valuable as storage units for intermittent renewable energy sources. Lithium, the lightest and most electropositive metal, would be the optimal anode material for rechargeable batteries if it were not for the fact that such devices fail unexpectedly by short-circuiting via the dendrites that grow across electrodes upon recharging. This phenomenon poses a major safety issue because it triggers a series of adverse events that start with overheating, potentially followed by the thermal decomposition and ultimately the ignition of the organic solvents used in such devices.

In this thesis, we developed experimental platform for monitoring and quantifying the dendrite populations grown in a Li battery prototype upon charging under various conditions. We explored the effects of pulse charging in the kHz range and temperature on dendrite growth, and also on loss capacity into detached “dead” lithium particles.

Simultaneously, we developed a computational framework for understanding the dynamics of dendrite propagation. The coarse-grained Monte Carlo model assisted us in the interpretation of pulsing experiments, whereas MD calculations provided insights into the mechanism of dendrites thermal relaxation. We also developed a computational framework for measuring the dead lithium crystals from the experimental images.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo do presente trabalho foi avaliar in vivo a detecção de cárie através do exame visual ICDAS, transiluminação por fibra ótica combinado ao ICDAS e exame radiográfico. Um total de 2.279 superfícies proximais e cicatrículas e fissuras em incisivos superiores, pré-molares e molares permanentes e 272 superfícies em molares decíduos em72 escolares (8 a 18 anos) foram avaliadas por um examinador treinado. Os sete escores para detecção de cárie primária do sistema visual ICDAS foram aplicados. Dois equipamentos de transiluminação por fibra ótica foram avaliados: FOTI Schott (SCH), com ponta de fibra ótica com 0,5mm de diâmetro, e FOTI Microlux (MIC), com diâmetro da ponta 3 mm. Durante o exame combinado FOTI/ICDAS, a fibra ótica era utilizada tanto para iluminar quanto para transiluminar a superfície sob avaliação. O exame radiográfico (RX) consistiu de radiografias interproximais posteriores e periapicais anteriores. Os exames foram realizados em consultório odontológico após escovação supervisionada. No primeiro dia de exame, o exame visual utilizando o ICDAS era realizado e em seguida, o exame combinado ao MIC ou SCH. Logo após era realizado o exame radiográfico. Após uma semana, novamente o ICDAS era realizado, e em seguida o exame combinado com o equipamento de FOTI não utilizado na semana anterior. Os exames foram repetidos em 10 pacientes após intervalo mínimo de uma semana para avaliação da reprodutibilidade intra-examinador, a qual apresentou valores de 0,95 (ICDAS), 0,94 (MIC), 0,95 (SCH) e 0,99 (RX) pelo kappa ponderado. Em cicatrículas e fissuras de permanentes, o RX julgou que um número maior de superfícies apresentava lesão em dentina (53) do que os outros métodos (34 a 36); porém não detectou nenhuma lesão em esmalte, as quais foram identificadas pelo ICDAS (94), SCH (107) e MIC (91). Em proximais permanentes, a transiluminação por fibra ótica identificou maior número de proximais como lesão em esmalte - 150 (SCH) e 139 (MIC) - do que o exame visual (106), enquanto o RX identificou somente 43. Em oclusais de decíduos, os quatro métodos julgaram um número aproximadamente similar de superfícies sem lesão (52 a 59) ou com lesão em dentina (21 a 26), assim como para lesões proximais em dentina (31 a 36). Entretanto um número reduzido de lesões proximais decíduas em esmalte foi julgado pelo exame radiográfico (3) em comparação com os outros métodos (15 a 16). Em decíduos, o ICDAS e o FOTI combinado ao exame visual julgaram maior número de lesões proximais em esmalte que o exame radiográfico, sendo que número similar de lesões em dentina foram classificadas pelos quatro métodos em oclusais e proximais de molares decíduos. Em cicatrículas e fissuras de permanentes, tanto o exame visual ICDAS quanto sua combinação aos dois equipamentos de transiluminação apresentaram maior similaridade de superfícies julgadas como lesão em esmalte ou como lesão em dentina, enquanto o exame radiográfico classificou mais superfícies como lesão em dentina e nenhuma como lesão em esmalte. A adição da transiluminação por fibra ótica ao exame visual aumentou em um terço a detecção das lesões cariosas proximais julgadas em dentina pelo ICDAS isoladamente e aproximadamente quadruplicou o número daquelas assim classificadas pela avaliação radiográfica em permanentes.