976 resultados para Peri-implant bone fenestration


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives This study evaluated the influence of oestrogen deficiency and its therapies on bone tissue around osseointegrated implants. Methods Implants were placed in 66 female rats tibiae. The animals were assigned into five groups: control (CTL), sham, ovariectomy (OVX), oestrogen (EST), and alendronate (ALE). While CTL was sacrificed 60 days after implant placement, other groups were subjected to ovariectomy or sham surgery according to group and euthanized after 90 days. Blood and urine samples were collected at sacrifice day for osteocalcin (OCN) and deoxypyridinoline (DPD) quantification. Densitometry of femur and lumbar vertebrae was performed in order to evaluate rats` skeletal impairment. Non-decalcified sections were referred to fluorescent and light microscopy for analyses of mineral apposition rate (MAR), eroded and osteoclastic surfaces, bone-to-implant contact (BIC), and bone area fraction occupancy (BAFO). Results Results from the OVX group showed significantly lower bone mineral density (BMD), BIC, BAFO, and MAR, while OCN, deoxipiridinoline, eroded surface and ostecoclastic surface were increased compared with the other groups of the study. ALE reduced OCN and DPD concentrations, MAR, osteoclastic and eroded surfaces, and no difference was in BIC and BAFO relative to SHAM. EST and CTL showed similar results to SHAM for measurements. Conclusions Oestrogen deficiency exerted a negative influence on bone tissue around implants, while oestrogen replacement therapy and alendronate were effective against its effects. Although alendronate therapy maintained the quantity of bone around implants, studies evaluating bone turnover kinetics are warranted. To cite this article:Giro G, Coelho PG, Pereira RMR, Jorgetti V, Marcantonio E Jr, Orrico SRP. The effect of oestrogen and alendronate therapies on postmenopausal bone loss around osseointegrated titanium implants.Clin. Oral Impl. Res. 22, 2011; 259-264.doi: 10.1111/j.1600-0501.2010.01989.x.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the influence of estrogen deficiency on bone around osseointegrated dental implants in a rat jaw model. Materials and Methods: This study used 16 female rats that had the first molars bilaterally extracted and were allowed to heal for 30 days before implant placement. Sixty days after implant placement, the animals were randomly subjected to sham surgery or ovariectomy (OVX). The animals were euthanized 90 days after OVX. Bone-to-implant contact, bone area fraction occupancy between implant threads, mineral density, turnover markers, and cells positive for tartrate-resistant acid phosphatase were assessed for the 2 groups. Results: The results showed that OVX group presented a decrease of systemic bone density, alterations in bone turnover markers, and an increase of cells positive for tartrate-resistant acid phosphatase compared with the sham-surgery group. However, no difference relative to bone-to-implant contact and bone area fraction occupancy was observed between groups. Conclusions: The findings of this study demonstrate that estrogen deficiency may not be considered a risk factor for osseointegrated implant failure in jaw bone. (C) 2011 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 69:1911-1918, 2011

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: This study evaluated the effect of magnesium dietary deficiency on bone metabolism and bone tissue around implants with established osseointegration. Materials and methods: For this, 30 rats received an implant in the right tibial metaphysis. After 60 days for healing of the implants, the animals were divided into groups according to the diet received Control group (CTL) received a standard diet with adequate magnesium content, while test group (Mg) received the same diet except for a 90% reduction of magnesium. The animals were sacrificed after 90 days for evaluation of calcium, magnesium, osteocalcin and parathyroid hormone (PTH) serum levels and the deoxypyridinoline (DPD) level in the urine. The effect of magnesium deficiency on skeletal bone tissue was evaluated by densitometry of the lumbar vertebrae, while the effect of bone tissue around titanium implants was evaluated by radiographic measurement of cortical bone thickness and bone density. The effect on biomechanical characteristics was verified by implant removal torque testing. Results: Magnesium dietary deficiency resulted in a decrease of the magnesium serum level and an increase of PTH and DPD levels (P <= 0.05). The Mg group also presented a loss of systemic bone mass decreased cortical bone thickness and lower values of removal torque of the implants (P <= 0.01). Conclusions: The present study concluded that magnesium-deficient diet had a negative influence on bone metabolism as well as on the bone tissue around the implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. This study evaluated the influence of estrogen deficiency and its treatment on bone density around integrated implants. Study design. Implants were placed in female rat tibiae. The animals were assigned to 5 groups: control, sham, ovariectomy, estrogen, and alendronate. The control group was humanely killed to confirm integration of the implant. The others were submitted to ovariectomy or sham surgery. Bone density was measured by digital radiographs at 6 points on sides of the implant. Results. The analysis of radiographic bone density revealed estrogen privation had a negative impact only in the cancellous bone. The estrogen group differed significantly ( P <.05) from the ovariectomy and alendronate groups. The alendronate group presented the highest density for all evaluated regions. Conclusion. Ovariectomy caused a decrease in the radiographic bone density in the cancellous region. Estrogen replacement therapy and alendronate were effective treatments in preventing bone mass loss around integrated implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose This study evaluated the effect of severe magnesium (Mg) dietary deficiency on systemic bone density and biomechanical resistance of bone tissue to the removal torque of osseointegrated implants Materials and Methods The sample consisted of 45 rats, each received a titanium implant in their tibial metaphysis After 60 days, the animals were divided into three groups (n = 15) according to their dietary Mg the control group received the recommended content of Mg, group Mg1 received a 75% reduction in dietary Mg content, and group Mg2 was fed a diet with a 90% reduction in Mg con tent Animals were sacrificed 150 days after implant placement Serum concentrations of Mg were measured and the effect of Mg deficiency on systemic bone density was evaluated by densitometry of the lumbar vertebrae and femur Biomechanical characteristics were measured by resistance of the bone tissue to removal of the implants Results Lower Mg serum concentrations were found for the Mg1 and Mg2 groups, however, densitometric analysis and torque evaluations showed a statistically significant difference only in the Mg2 group (P < 05) There was a statistically significant difference in removal torque between the Mg2 group and the control group Conclusions This study showed that a severe deficiency of Mg decreased the systemic bone density and removal torque of osseointegrated implants INT J ORAL MAXILLOFAC IMPLANTS 2010 25 1125-1130

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to determine whether bone marrow-derived cells can differentiate into myofibroblasts, as defined by alpha-smooth muscle actin (SMA) expression, that arise in the corneal stroma after irregular phototherapeutic keratectomy and whose presence within the cornea is associated with corneal stromal haze. C578L/6J-GFP chimeric mice were generated through bone marrow transplantation from donor mice that expressed enhanced green fluorescent protein (GFP) in a high proportion of their bone marrow-derived cells. Twenty-four GFP chimeric mice underwent haze-generating corneal epithelial scrape followed by irregular phototherapeutic keratectomy (PTK) with an excimer laser in one eye. Mice were euthanized at 2 weeks or 4 weeks after PTK and the treated and control contralateral eyes were removed and cryo-preserved for sectioning for immunocytochemistry. Double immunocytochemistry for GFP and myofibroblast marker alpha-smooth muscle actin (SMA) were performed and the number of SMA+GFP+, SMA+GFP, SMA-GFP+ and SMA GFP cells, as well as the number of DAPI+ cell nuclei, per 400x field of stroma was determined in the central, mid-peripheral and peri-limbal cornea. In this mouse model, there were no SMA+ cells and only a few GFP+ cells detected in unwounded control corneas. No SMA+ cells were detected in the stroma at two weeks after irregular PTK, even though there were numerous GFP+ cells present. At 4 weeks after irregular PTK, all corneas developed mild to moderately severe corneal haze. In each of the three regions of the corneas examined, there were on average more than 9x more SMA+GFP+ than SMA+GFP myofibroblasts. This difference was significant (p < 0.01). There were significantly more (p < 0.01) SMA GFP+ cells, which likely include inflammatory cells, than SMA+GFP+ or SMA+GFP cells, although SMA GFP cells represent the largest population of cells in the corneas. In this mouse model, the majority of myofibroblasts developed from bone marrow-derived cells. It is possible that all myofibroblasts in these animals developed from bone marrow-derived cells since mouse chimeras produced using this method had only 60-95% of bone marrow-derived cells that were GFP+ and it is not possible to achieve 100% chimerization. This model, therefore, cannot exclude the possibility of myofibroblasts also developed from keratocytes and/or corneal fibroblasts. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

P>Objective Limited data have been reported on the effect of parathyroidectomy (PTx) on bone mineral density (BMD) in the setting of patients with hyperparathyroidism (HPT) associated with multiple endocrine neoplasia type 1 (MEN1). This study investigates the impact of total PTx on BMD in patients with HPT/MEN1. Design and patients A case series study was performed in a tertiary academic hospital. A total of 16 HPT/MEN1 patients from six families harbouring MEN1 germline mutations were subjected to total PTx followed by parathyroid auto-implant in the forearm. Measurements Bone mineral density values were assessed using dual-energy X-ray absorptiometry. Results Before PTx, reduced BMD (Z-score <-2 center dot 0) was highly prevalent in the proximal one-third of the distal radius (1/3 DR) (50%), lumbar spine (LS) (43 center dot 7%), ultradistal radius (UDR) (43 center dot 7%), femoral neck (FN) (25%) and total femur (TF) (18 center dot 7%) in the patients. Fifteen months after PTx, we observed a BMD improvement in the LS (from 0 center dot 843 to 0 center dot 909 g/cm2; +8 center dot 4%, P = 0 center dot 001), FN (from 0 center dot 745 to 0 center dot 798 g/cm2; +7 center dot 7%, P = 0 center dot 0001) and TF (from 0 center dot 818 to 0 center dot 874 g/cm2; +6 center dot 9%, P < 0 center dot 0001). No significant change was noticed in the 1/3 DR and UDR after PTx. Conclusions This data confirmed BMD recovery in the LS and FN after PTx in HPT/MEN1 patients. We also documented a significant BMD increase in the TF and no change in both the 1/3 DR and UDR BMD after PTx. Our data suggest that LS and proximal femur are the most informative sites to evaluate the short-term BMD outcome after PTx in HPT/MEN1 subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are many different opinions in the literature regarding the best procedure for revision of infected hip arthroplasty and hence in achieving long-term stabilization of a new implant. Thirty-two patients with 32 loose and infected total hip arthroplasties underwent revision with a bone graft in a 1-stage procedure. The bone graft was used in the acetabulum and femure in 25 patients, in the acetabulum alone in 4 patients and in the femur alone in 3 patients. A metal mesh was necessary in 15 patients to contain the morselized bone graft. At the time of surgical revision, 9 patients had a draining sinus, 6 had a closed sinus, and 17 had never had sinuses in the surgical wound. Antibiotic therapy was administered intravenously and orally for 6 months. Mean follow-up was 103 months (range, 63-183 months), and infection recurred in 2 (6.2%) cases. Further studies are necessary, and continuation of this method is justified.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the newly formed bone, comparing two different carriers for rhBMP-2, using the decortication and nondecorticatication surgical technique in Wistar rat mandibles, evaluated by radiographic densitometry method. It was used fifty six animals according to specific treatment, which were sacrificed after 3 and 6 weeks after this. It was concluded that the decortication surgical technique was able to optimize the osteoinduction properties of the rhBMP-2, independently of the material carrier used and the period of time, according to radiographic densitometry technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to analyze electrocardiographic alterations during dental implant surgeries when local anesthetic agents were used. Materials and Methods: Twenty implants were placed in 18 healthy patients. An electrocardiogram and Wincardio software were used to gather recordings from 12 static leads every 2 minutes, continuously record coronary artery (D2) derivations, and automatically measure the following electrocardiographic parameters: heart rate, duration and amplitude of the P wave, PR segment duration, ST segment deviation, QRS complex duration, and duration of the RR, QT, and corrected QT (QTc) intervals. Results: Analysis of variance of the values obtained at the different stages showed significant differences (P < .05) for the heart rate and for the duration of the RR and QT intervals. The heart rate increased during the anesthesia, incision, and bone drilling stages, reaching a peak during drilling. Duration of the RR and QT intervals decreased during the incision and drilling stages. Among the electrocardiographic parameters individually assessed, several altered values were found for the duration of the P wave, the QRS complex, and the QT and QTc intervals. Sinusal tachycardia and bradycardia, sinusal arrhythmia, supraventricular extrasystole, ventricular extrasystole, and T-wave inversion were detected. Conclusion: Dental implant placement surgery may induce electrocardiographic alterations. The most frequently found arrhythmias were extrasystole and sinusal tachycardia. The anesthesia, incision, and bone drilling stages exhibited the highest heart rate values and the shortest durations of the RR and QT intervals. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:412-418

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: This prospective and controlled histologic study evaluates the impact of smoking on bone-to-implant contact, the bone density in the threaded area, and the bone density outside the threaded area around microimplants with anodized surface retrieved from human jaws. Methods: A total of 24 subjects (mean age 51.32 +/- 7.5 years) were divided in two groups: smokers (n = 13 subjects) and non-smokers (n = 11 subjects). Each subject received one microimplant with oxidized surface during conventional mandible or maxilla implant surgery. After 8 weeks, the microimplants and the surrounding tissue were removed and prepared for histomorphometric analysis. Results: Three microimplants placed in smokers showed no osseointegration. The newly formed bone showed early stages of maturation, mainly in the non-smokers. Marginal bone loss, gap, and fibrous tissue were present around implants retrieved from smokers. Histometric evaluation indicated that the mean bone-to-implant contact ranged between 25.97% +/- 9.02% and 40.01% +/- 12.98% for smokers and non-smokers, respectively (P <0.001). Smokers presented 28.17% +/- 10.32% of bone density in the threaded area, whereas non-smokers showed 46.34% +/- 19.12%. The mean of bone density outside the threaded area ranged between 18.76% and 25.11% for smokers and non-smokers, respectively (P>0.05). Conclusion: The present data obtained in human subjects confirm that smoking has a detrimental effect on early bone tissue response around oxidized implant surfaces. J Periodontol 2010;81:575-583.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the biomechanical and microscopic response of previously grafted bone to titanium implants. The lower incisors of 16 rabbits were surgically extracted, and bilateral perforations communicating with the remaining sockets were created distally. A socket/perforation defect on each mandible was chosen at random to be immediately filled with a xenogenic graft, whereas the contralateral perforation was left to heal naturally and served as a paired control. After 60 days, titanium implants were installed in the previously operated areas. After periods of 2 and 6 months, the animals were killed, and the force necessary to retrieve implants as well as the bone-implant contact (BIC) and bone mass (BM) were quantified and statistically compared by 2-way analysis of variance and Tukey`s test (alpha = .05). No significant differences in removal torque were observed, either by time or by treatment condition. Differences in BIC and BM between experimental and control groups were not statistically significant through the intervals studied (P < .05). The presence of a xenogenic graft did not influence the microscopic tissue response to titanium implants or fixation into newly formed or mature bone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. This study evaluated the reliability of tooth-crown radiographic references to aid in orthodontic mini-implant insertion and showed an insertion technique based on these references. Study design. The sample consisted of 213 interradicular septa evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width and its midpoint was linked to the interdental contact point to determine septum midline (SML). The distances from SML to mesial and distal teeth were measured and compared to evaluate SML centralization degree in 2 different septum heights. Results. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. Conclusions. The tooth-crown radiographic references determine a high centralization degree of the SML on which an insertion site could be defined. The greater SML centralization degree was observed at the coronal septum area. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e8-e16)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Understanding how clinical variables affect stress distribution facilitates optimal prosthesis design and fabrication and may lead to a decrease in mechanical failures as well as improve implant longevity. Purpose: In this study, the many clinical variations present in implant-supported prosthesis were analyzed by 3-D finite element method. Materials and Method: A geometrical model representing the anterior segment of a human mandible treated with 5 implants supporting a framework was created to perform the tests. The variables introduced in the computer model were cantilever length, elastic modulus of cancellous bone, abutment length, implant length, and framework alloy (AgPd or CoCr). The computer was programmed with physical properties of the materials as derived from the literature, and a 100N vertical load was used to simulate the occlusal force. Images with the fringes of stress were obtained and the maximum stress at each site was plotted in graphs for comparison. Results: Stresses clustered at the elements closest to the loading point. Stress increase was found to be proportional to the increase in cantilever length and inversely proportional to the increase in the elastic modulus of cancellous bone. Increasing the abutment length resulted in a decrease of stress on implants and framework. Stress decrease could not be demonstrated with implants longer than 13 mm. A stiffer framework may allow better stress distribution. Conclusion: The relative physical properties of the many materials involved in an implant-supported prosthesis system affect the way stresses are distributed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.