996 resultados para Oxygen supply


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrospun poly(vinylidene fluoride) (PVDF) fiber mats find applications in an increasing number of areas, such as battery separators, filtration and detection membranes, due to their excellent properties. However, there are limitations due to the hydrophobic nature and low surface energy of PVDF. In this work, oxygen plasma treatment has been applied in order to modify the surface wettability of PVDF fiber mats and superhydrophilic PVDF electrospun membranes have been obtained. Further, plasma treatment does not significantly influences fiber average size (~400 ± 200 nm), morphology, electroactive -phase content (~80-85%) or the degree of crystallinity (Xc of 42 ± 2%), allowing to maintain the excellent physical-chemical characteristics of PVDF. Plasma treatment mainly induces surface chemistry modifications, such as the introduction of oxygen and release of fluorine atoms that significantly changes polymer membrane wettability by a reduction of the contact angle of the polymer fibers and an overall decrease of the surface tension of the membranes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expanding access to preschool education is a particularly important policy issue in developing countries, where enrollment rates are generally much lower, and where private institutions constitute a much larger share of the formal preschool sector, than in developed countries. This paper examines if an expansion in the supply of public preschool crowds-out private enrollment using rich data for municipalities in Brazil from 2000 to 2006, where federal transfers to local governments change discontinuously with given population thresholds. Results from a regression-discontinuity design reveal that larger federal transfers lead to a significant expansion of local public preschool services, but show no evidence of crowding-out of private enrollment, nor of negative impacts on the quality of private providers. This finding is consistent with a theory in which households differ in willingness-to-pay for preschool services, and private suppliers optimally adjust prices in response to an expansion of lower-quality, free-of-charge public supply. In the context of the model, the absence of crowding-out effects of more public preschool providers can be rationalized by the existence of relatively large differences in willingness-to-pay for preschool services across different demand segments. Our theoretical and empirical findings therefore suggest that in developing country settings characterized by relatively high income inequality, an expansion in public preschool supply will likely significantly increase enrollment among the poorest segments of society, and need not have adverse effects on the quantity or quality of local private supply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this work was to study the central and peripheral thickness of several contact lenses (CL) with different powers and analyze how thickness variation affects CL oxygen transmissibility. METHODS: Four daily disposable and five monthly or biweekly CL were studied. The powers of each CL were: the maximum negative power of each brand; -6.00 D; -3.00 D; zero power (-0.25 D or -0.50 D), +3.00 D and +6.00 D. Central and peripheral thicknesses were measured with an electronic thickness gauge. Each lens was measured five times (central and 3mm paracentral) and the mean value was considered. Using the values of oxygen permeability given by the manufacturers and the measured thicknesses, the variation of oxygen transmissibility with lens power was determined. RESULTS: For monthly or biweekly lenses, central thickness changed between 0.061 ± 0.002 mm and 0.243 ± 0.002 mm, and peripheral thickness varied between 0.084 ± 0.002 mm and 0.231 ± 0.015 mm. Daily disposable lenses showed central values ranging between 0.056 ± 0.0016 mm and 0.205 ± 0.002 mm and peripheral values between 0.108 ± 0.05 and 0.232 ± 0.011 mm. Oxygen transmissibility (in units) of monthly or biweekly CL ranged between 39.4 ± 0.3 and 246.0 ± 14.4 and for daily disposable lenses the values range between 9.5 ± 0.5 and 178.1 ± 5.1. CONCLUSIONS: The central and peripheral thicknesses change significantly when considering the CL power and this has a significant impact on the oxygen transmissibility. Eyecare practitioners must have this fact in account when high power plus or minus lenses are fitted or when continuous wear is considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ternary aluminium oxynitride (AlNxOy) system offers the possibility to obtain a wide range of properties by tailoring the ratio between pure Al, AlNx and AlOy and therefore opening a significant number of possible applications. In this work the thermal behaviour of AlNxOy thin films was analysed by modulated infrared radiometry (MIRR), taking as reference the binary AlOy and AlNx systems. MIRR is a non-contact and non-destructive thermal wave measurement technique based on the excitation, propagation and detection of temperature oscillations of very small amplitudes. The intended change of the partial pressure of the reactive gas (N2 and/or O2) influenced the target condition and hence the deposition characteristics which, altogether, affected the composition and microstructure of the films. Based on the MIRR measurements and their qualitative and quantitative interpretation, some correlations between the thermal transport properties of the films and their chemical/physical properties have been found. Furthermore, the potential of such technique applied in this oxynitride system, which present a wide range of different physical responses, is also discussed. The experimental results obtained are consistent with those reported in previous works and show a high potential to fulfil the demands needed for the possible applications of the systems studied. They are clearly indicative of an adequate thermal response if this particular thin film system is aimed to be applied in small sensor devices or in electrodes for biosignal acquisition, such as those for electroencephalography or electromyography as it is the case of the main research area that is being developed in the group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Production of citric acid from crude glycerol from biodiesel industry, in batch cultures of Yarrowia lipolytica W29 was performed in a lab-scale stirred tank bioreactor in order to assess the effect of oxygen mass transfer rate in this bioprocess. An empirical correlation was proposed to describe oxygen volumetric mass transfer coefficient (kLa) as a function of operating conditions (stirring speed and specific air flow rate) and cellular density. kLa increased according with a power function with specific power input and superficial gas velocity, and slightly decreased with cellular density. The increase of initial kLa from 7 h-1 to 55 h-1 led to 7.8-fold increase of citric acid final concentration. Experiments were also performed at controlled dissolved oxygen (DO) and citric acid concentration increased with DO up to 60% of saturation. Thus, due to the simpler operation setting an optimal kLa than at controlled DO, it can be concluded that kLa is an adequate parameter for the optimization of citric acid production from crude glycerol by Y. lipolytica and to be considered in bioprocess scale-up. Our empirical correlation, considering the operating conditions and cellular density, will be a valid tool for this purpose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ag and AgxO thin films were deposited by non-reactive and reactive pulsed DC magnetron sputtering, respectively, with the final propose of functionalizing the SS316L substrate with antibacterial properties. The coatings were characterized chemically, physically and structurally. The coatings nanostructure was assessed by X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS), while the coatings morphology was determined by scanning electron microscopy (SEM). The XRD and XPS analyses suggested that Ag thin film is composed by metallic Ag, which crystallizes in fcc-Ag phase, while the AgxO thin film showed both metallic Ag and Ag-O bonds, which crystalize in fcc-Ag and silver oxide phases. The SEM results revealed that Ag thin film formed a continuous layer, while AgxO layer was composed of islands with hundreds of nanometers surrounded by small nanoparticles with tens of nanometers. The surface wettability and surface tension parameters were determined by contact angle measurements, being found that Ag and AgxO surfaces showed very similar behavior, with all the surfaces showing a hydrophobic character. In order to verify the antibacterial behavior of the coatings, halo inhibition zone tests were realized for Staphylococcus epidermidis and Staphylococcus aureus. Ag coatings did not show antibacterial behavior, contrarily to AgxO coating, which presented antibacterial properties against the studied bacteria. The presence of silver oxide phase along with the development of different morphology were pointed as the main factors in the origin of the antibacterial effect found in AgxO thin film. The present study demonstrated that AgxO coating presented antibacterial behavior and its application in cardiovascular stents is promising.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare peak exercise oxygen consumption (VO2peak) of healthy individuals with asymptomatic individuals with probable heart disease. METHODS: Ninety-eight men were evaluated. They were divided into two groups: 1) 39 healthy individuals (group N) with an age range of 50±4.6 years; and 2) 59 asymptomatic individuals with signs of atherosclerotic and/or hypertensive heart disease (group C) with an age range of 51.9±10.4 years. In regard to age, height, body surface area, percentage of fat, lean body mass, and daily physical activity, both groups were statistically similar. Environmental conditions during the ergometric test were also controlled. RESULTS: Maximal aerobic power (watts), VO2peak, maximal heart rate, and maximal pulmonary ventilation were lower in group C (p<0.01) than in group N; weight, however, was lower in group N (p=0.031) than in group C. Differences in the respiratory gas exchange index, heart rate at rest, and the maximal double product of the two groups were not statistically significant. CONCLUSION: Signs of probable heart disease, even though asymptomatic, may reduce the functional capacity, perhaps due to the lower maximal cardiac output and/or muscle metabolic changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the effects of 3 types of noninvasive respiratory support systems in the treatment of acute pulmonary edema: oxygen therapy (O2), continuous positive airway pressure, and bilevel positive pressure ventilation. METHODS: We studied prospectively 26 patients with acute pulmonary edema, who were randomized into 1 of 3 types of respiratory support groups. Age was 69±7 years. Ten patients were treated with oxygen, 9 with continuous positive airway pressure, and 7 with noninvasive bilevel positive pressure ventilation. All patients received medicamentous therapy according to the Advanced Cardiac Life Support protocol. Our primary aim was to assess the need for orotracheal intubation. We also assessed the following: heart and respiration rates, blood pressure, PaO2, PaCO2, and pH at begining, and at 10 and 60 minutes after starting the protocol. RESULTS: At 10 minutes, the patients in the bilevel positive pressure ventilation group had the highest PaO2 and the lowest respiration rates; the patients in the O2 group had the highest PaCO2 and the lowest pH (p<0.05). Four patients in the O2 group, 3 patients in the continuous positive pressure group, and none in the bilevel positive pressure ventilation group were intubated (p<0.05). CONCLUSION: Noninvasive bilevel positive pressure ventilation was effective in the treatment of acute cardiogenic pulmonary edema, accelerated the recovery of vital signs and blood gas data, and avoided intubation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Bioengineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adoption of a sustainable approach to meeting the energy needs of society has recently taken on a more central and urgent place in the minds of many people. There are many reasons for this including ecological, environmental and economic concerns. One particular area where a sustainable approach has become very relevant is in the production of electricity. The contribution of renewable sources to the energy mix supplying the electricity grid is nothing new, but the focus has begun to move away from the more conventional renewable sources such as wind and hydro. The necessity of exploring new and innovative sources of renewable energy is now seen as imperative as the older forms (i.e. hydro) reach the saturation point of their possible exploitation. One such innovative source of energy currently beginning to be utilised in this regard is tidal energy. The purpose of this thesis is to isolate one specific drawback to tidal energy, which could be considered a roadblock to this energy source being a major contributor to the Irish national grid. This drawback presents itself in the inconsistent nature in which a tidal device generates energy over the course of a 24 hour period. This inconsistency of supply can result in the cycling of conventional power plants in order to even out the supply, subsequently leading to additional costs. The thesis includes a review of literature relevant to the area of tidal and other marine energy sources with an emphasis on the state of the art devices currently in development or production. The research carried out included tidal data analysis and manipulation into a model of the power generating potential at specific sites. A solution is then proposed to the drawback of inconsistency of supply, which involves the positioning of various tidal generation installations at specifically selected locations around the Irish coast. The temporal shift achieved in the power supply profiles of the individual sites by locating the installations in the correct locations, successfully produced an overall power supply profile with the smoother curve and a consistent base load energy supply. Some limitations to the method employed were also outlined, and suggestions for further improvements to the method were made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this dissertation is to investigate the effect wind energy has on the Electricity Supply Industry in Ireland. Wind power generation is a source of renewable energy that is in abundant supply in Ireland and is fast becoming a resource that Ireland is depending on as a diverse and secure of supply of energy. However, wind is an intermittent resource and coupled with a variable demand, there are integration issues with balancing demand and supply effectively. To maintain a secure supply of electricity to customers, it is necessary that wind power has an operational reserve to ensure appropriate backup for situations where there is low wind but high demand. This dissertation examines the affect of this integration by comparing wind generation to that of conventional generation in the national grid. This is done to ascertain the cost benefits of wind power generation against a scenario with no wind generation. Then, the analysis examines to see if wind power can meet the pillars of sustainability. This entails looking at wind in a practical scenario to observe how it meets these pillars under the criteria of environmental responsibility, displacement of conventional fuel, cost competitiveness and security of supply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The equations predicting maximal oxygen uptake (VO2max or peak) presently in use in cardiopulmonary exercise testing (CPET) softwares in Brazil have not been adequately validated. These equations are very important for the diagnostic capacity of this method. Objective: Build and validate a Brazilian Equation (BE) for prediction of VO2peak in comparison to the equation cited by Jones (JE) and the Wasserman algorithm (WA). Methods: Treadmill evaluation was performed on 3119 individuals with CPET (breath by breath). The construction group (CG) of the equation consisted of 2495 healthy participants. The other 624 individuals were allocated to the external validation group (EVG). At the BE (derived from a multivariate regression model), age, gender, body mass index (BMI) and physical activity level were considered. The same equation was also tested in the EVG. Dispersion graphs and Bland-Altman analyses were built. Results: In the CG, the mean age was 42.6 years, 51.5% were male, the average BMI was 27.2, and the physical activity distribution level was: 51.3% sedentary, 44.4% active and 4.3% athletes. An optimal correlation between the BE and the CPET measured VO2peak was observed (0.807). On the other hand, difference came up between the average VO2peak expected by the JE and WA and the CPET measured VO2peak, as well as the one gotten from the BE (p = 0.001). Conclusion: BE presents VO2peak values close to those directly measured by CPET, while Jones and Wasserman differ significantly from the real VO2peak.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organotypic hippocampal slice cultures, neurogenesis, posterior periventricle, oxygen-glucose deprivation, microglia, inflammation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:Aerobic fitness, assessed by measuring VO2max in maximum cardiopulmonary exercise testing (CPX) or by estimating VO2max through the use of equations in exercise testing, is a predictor of mortality. However, the error resulting from this estimate in a given individual can be high, affecting clinical decisions.Objective:To determine the error of estimate of VO2max in cycle ergometry in a population attending clinical exercise testing laboratories, and to propose sex-specific equations to minimize that error.Methods:This study assessed 1715 adults (18 to 91 years, 68% men) undertaking maximum CPX in a lower limbs cycle ergometer (LLCE) with ramp protocol. The percentage error (E%) between measured VO2max and that estimated from the modified ACSM equation (Lang et al. MSSE, 1992) was calculated. Then, estimation equations were developed: 1) for all the population tested (C-GENERAL); and 2) separately by sex (C-MEN and C-WOMEN).Results:Measured VO2max was higher in men than in WOMEN: -29.4 ± 10.5 and 24.2 ± 9.2 mL.(kg.min)-1 (p < 0.01). The equations for estimating VO2max [in mL.(kg.min)-1] were: C-GENERAL = [final workload (W)/body weight (kg)] x 10.483 + 7; C-MEN = [final workload (W)/body weight (kg)] x 10.791 + 7; and C-WOMEN = [final workload (W)/body weight (kg)] x 9.820 + 7. The E% for MEN was: -3.4 ± 13.4% (modified ACSM); 1.2 ± 13.2% (C-GENERAL); and -0.9 ± 13.4% (C-MEN) (p < 0.01). For WOMEN: -14.7 ± 17.4% (modified ACSM); -6.3 ± 16.5% (C-GENERAL); and -1.7 ± 16.2% (C-WOMEN) (p < 0.01).Conclusion:The error of estimate of VO2max by use of sex-specific equations was reduced, but not eliminated, in exercise tests on LLCE.