910 resultados para Instrument flying.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A novel instrument for measurement of X-ray intensity from mammography consists of a sensitive pyro-electric detector, a high-sensitivity, low-noise current-to-voltage converter, a microcontroller and a digital display. The heart of this device, and what makes it unique is the pyro-electric detector, which measures radiation by converting heat from absorbed incident X-rays into an electric current. This current is then converted to a voltage and digitised. The detector consists of a ferro-electric crystal; two types were tested; lithium tantalate and lithium niobate. X-ray measurement in mammography is challenging because of its relatively low photon energy range, from 11 keV to 15 keV equivalent mean energy, corresponding to a peak tube potential from 22 to 36 kV. Consequently, energy fluence rate or intensity is low compared with that of common diagnostic X-ray. The instrument is capable of measuring intensities as low as 0.25 mWm -2 with precision greater than 99%. Not only was the instrument capable of performing in the clinical environment, with high background electromagnetic interference and vibration, but its performance was not degraded after being subjected to 140 roentgen (3.6 × 10 -2 C kg -2 air) as measured by piezo-electric (d 33) or pyro-electric coefficients. © IFMBE 2005.
Resumo:
In order to evaluate the flying capacity and nest site selection of Angiopolybia pallens (Lepeletier, 1836), we made 17 incursions (136 hours of sample efforts) in Atlantic Rain Forest environments in Bahia state. Our data show this wasp prefers to nest on wide leaves of bushes and short trees (nests between 0.30 and 3m from the ground) placed in half-shady environments (clearings and shadowed cultivations). The logistic regression model using Quasi-Newton method provided a good description of the flying capacity observed in A. pallens (x 2 = 91.52; p≪0.001). According to the logistic regression model, the A. pallens flight autonomy is low, flying for short distances and with an effective radius of action of about 24m measured from their nests, which means a foraging area of nearly 1,800 m 2.
Resumo:
Due to a shortage of textbooks with specific data on muscular activity concerning physical conditioning and sports, we analysed electromyographically the muscles pectoralis major and deltoideus anterior, bilaterally, in inclined flying exercises, during the concentric and eccentric phases, with external loads of 25, 50, 75 and 100% of the maximum load. The electromyographic analysis was performed in eleven male volunteers with MEDITRACE-200 surface electrodes connected to a six-channel biologic signal acquisition module coupled to a PC/AT computer. The electromyographic signals were processed and the obtained effective values were normalized through maximum voluntary isometric contraction. Statistically, the results showed that all the muscles studied presented significant differences between the concentric and the eccentric phases, with higher electromyographic activity during the concentric phase. By analysing the different loads for each muscle in both phases, significant electromyographic activity was observed for all muscles. When the effect of each load on each muscle during the concentric phase was analysed, it was noticed that the muscles on the left were more active than those on the right side, while in the eccentric phase the muscles had different behavior.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Aim To assess the dimensional characteristics, flexibility and torsional behaviour of nickel-titanium retreatment instruments. Methodology Using image analysis software and high-resolution digital images, the instrument length, tip angle, diameter at 3mm from the tip and the distance between the blades (pitch length) of the following eight instruments were measured (n=12 for each measurement parameter): the ProTaper Universal retreatment (PTU-R) D1, D2 and D3 instruments; the R-Endo R1, R2 and R3 retreatment instruments; and the Mtwo retreatment (Mtwo-R) sizes 25 and 15 retreatment instruments. Maximum torque and the angular deflection at fracture as well as the bending moment at 45° were measured (n=12) according to the International Standards Organisation (ISO) specification number 3630-1. Data were analysed using the analysis of variance (α=0.05). Results The length of the active part of the instruments was found to vary according to the depth of the canal into which they were designed to reach. The pitch length also increased along the active length. The PTU-R D1 and the Mtwo-R instruments had active tips. Measurements of the bending moment at 45° revealed that the Mtwo-R 15 instrument was the most flexible, whereas the PTU-R D1 was the least flexible. The maximum torque tended to increase as the instrument diameter at 3mm from the tip increased, whereas the angular deflection at fracture varied in the opposite direction. Conclusions The geometrical characteristics of the retreatment instruments and their flexibility and torsion behaviour were consistent with their intended clinical application. © 2011 International Endodontic Journal.
Resumo:
The objectives of this study were to assess the interrater reproducibility of the instrument to classify pediatric patients with cancer; verify the adequacy of the patient classification instrument for pediatric patients with cancer; and make a proposal for changing the instrument, thus allowing for the necessary adjustments for pediatric oncology patients. A total of 34 pediatric inpatients of a Cancer Hospital were evaluated by the teams of physicians, nurses and nursing technicians. The Kappa coefficient was used to rate the agreement between the scores, which revealed a moderate to high value in the objective classifications, and a low value in the subjective. In conclusion, the instrument is reliable and reproducible, however, it is suggested that to classify pediatric oncology patients, some items should be complemented in order to reach an outcome that is more compatible with the reality of this specific population.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Contiene asistencia, organización de los trabajos y resumen de los debates de la reunión que tuvo como principal objetivo analizar aspectos de la cooperación internacional en materia de evaluaciones del impacto ambiental.
Resumo:
Includes bibliography