994 resultados para Initial solution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The sorption of sulfamethoxazole, a frequently detected pharmaceutical compound in the environment, onto walnut shells was evaluated. Methods: The sorption proprieties of the raw sorbent were chemically modified and two additional samples were obtained, respectively HCl and NaOH treated. Scanning electron microscopy, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and thermogravimetric (TG/DTG) techniques were applied to investigate the effect of the chemical treatments on the shell surface morphology and chemistry. Sorption experiments to investigate the pH effect on the process were carried out between pH 2 and 8. Results: The chemical treatment did not substantially alter the structure of the sorbent (physical and textural characteristics) but modified the surface chemistry of the sorbent (acid–base properties, point of zero charge—pHpzc). The solution pH influences both the sorbent’s surface charge and sulfamethoxazole speciation. The best removal efficiencies were obtained for lower pH values where the neutral and cationic sulfamethoxazole forms are present in the solution. Langmuir and Freundlich isotherms were applied to the experimental adsorption data for sulfamethoxazole sorption at pH 2, 4, and 7 onto raw walnut shell. No statistical difference was found between the two models except for the pH 2 experimental data to which the Freundlich model fitted better. Conclusion: Sorption of sulfamethoxazole was found to be highly pH dependent in the entire pH range studied and for both raw and treated sorbent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solution enthalpies of 1,4-dioxane have been obtained in 15 protic and aprotic solvents at 298.15 K. Breaking the overall process through the use of Solomonov's methodology the cavity term was calculated and interaction enthalpies (Delta H-int) were determined. Main factors involved in the interaction enthalpy have been identified and quantified using a QSPR approach based on the TAKA model equation. The relevant descriptors were found to be pi* and beta, which showed, respectively, exothermic and endothermic contributions. The magnitude of pi* coefficient points toward non-specific solute-solvent interactions playing a major role in the solution process. The positive value of the beta coefficient reflects the endothermic character of the solvents' hydrogen bond acceptor (HBA) basicity contribution, indicating that solvent molecules engaged in hydrogen bonding preferentially interact with each other rather than with 1,4-dioxane. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho teve como principais objectivos, estudar e optimizar o processo de tratamento do efluente proveniente das máquinas da unidade Cold-press da linha de produção da Empresa Swedwood, caracterizar a solução límpida obtida no tratamento e estudar a sua integração no processo, e por fim caracterizar o resíduo de pasta de cola obtido no tratamento e estudar a possível valorização energética deste resíduo. Após caracterização inicial do efluente e de acordo com os resultados de um estudo prévio solicitado pela Empresa Swedwood a uma empresa externa, decidiu-se iniciar o estudo de tratabilidade do efluente pelo processo físico-químico a coagulação/floculação. No processo de coagulação/floculação estudou-se a aplicabilidade, através de ensaios Jar-test, dos diferentes agentes de coagulação/floculação: a soda cáustica, a cal, o cloreto férrico e o sulfato de alumínio. Os melhores resultados neste processo foram obtidos com a adição de uma dose de cal de 500 mg/Lefluente, seguida da adição de 400 mg/Lefluente de sulfato de alumínio. Contudo, após este tratamento o clarificado obtido não possuía as características necessárias para a sua reintrodução no processo fabril nem para a sua descarga em meio hídrico. Deste modo procedeu-se ao estudo de tratamentos complementares. Nesta segunda fases de estudo testaram-se os seguintes os tratamentos: a oxidação química por Reagente de Fenton, o tratamento biológico por SBR (sequencing batch reactor) e o leito percolador. Da análise dos resultados obtidos nos diferentes tratamentos conclui-se que o tratamento mais eficaz foi o tratamento biológico por SBR com adição de carvão activado. Prevê-se que no final do processo de tratamento o clarificado obtido possa ser descarregado em meio hídrico ou reintroduzido no processo. Como o estudo apenas foi desenvolvido à escala laboratorial, seria útil poder validar os resultados numa escala piloto antes da sua implementação industrial. A partir dos resultados do estudo experimental, procedeu-se ao dimensionamento de uma unidade de tratamento físico-químico e biológico à escala industrial para o tratamento de 20 m3 de efluente produzido na fábrica, numa semana. Dimensionou-se ainda a unidade (leito de secagem) para tratamento das lamas produzidas. Na unidade de tratamento físico-químico (coagulação/floculação) os decantadores estáticos devem possuir o volume útil de 4,8 m3. Sendo necessários semanalmente 36 L da suspensão de cal (Neutrolac 300) e 12,3 L da solução de sulfato de alumínio a 8,3%. Os tanques de armazenamento destes compostos devem possuir 43,2 litros e 96 litros, respectivamente. Nesta unidade estimou-se que são produzidos diariamente 1,4 m3 de lamas. Na unidade de tratamento biológico o reactor biológico deve possuir um volume útil de 6 m3. Para que este processo seja eficaz é necessário fornecer diariamente 2,1 kg de oxigénio. Estima-se que neste processo será necessário efectuar a purga de 325 litros de lamas semanalmente. No final da purga repõe-se o carvão activado, que poderá ser arrastado juntamente com as lamas, adicionando-se 100 mg de carvão por litro de licor misto. De acordo com o volume de lamas produzidos em ambos os tratamentos a área mínima necessária para o leito de secagem é de cerca de 27 m2. A análise económica efectuada mostra que a aquisição do equipamento tem o custo de 22.079,50 euros, o custo dos reagentes necessários neste processo para um ano de funcionamento tem um custo total de 508,50 euros e as necessidades energéticas de 2.008,45 euros.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil Especialização em Edificações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Como o sector cerâmico é um consumidor intensivo de energia, este trabalho teve como objectivo principal a elaboração de um plano de optimização do desempenho energético da olaria número três da Fábrica Cerâmica de Valadares. Para o efeito, efectuou-se o levantamento energético desta fracção autónoma. O valor total obtido para os ganhos térmicos foi de 8,7x107 kJ/dia, sendo 82% desta energia obtida na combustão do gás natural. Por outro lado, as perdas energéticas rondam os 8,2x107 kJ/dia, sendo o ar de exaustão e a envolvente os principais responsáveis, com um peso de 42 % e 38%, respectivamente. Tendo em conta estes valores, estudaram-se várias medidas de isolamento da cobertura, pavimento, paredes e saída de ar através de fendas do edifício. No caso do isolamento da cobertura sugeriu-se a substituição das telhas de fibrocimento e do isolamento actualmente existentes por painéis sandwich de cobertura. Esta acção permite uma poupança de 64.796€/ano, com um investimento de 57.029€ e o seu período de retorno de 0,9 anos. O Valor Actualizado Líquido (VAL) no 5º ano foi de 184.069€, com uma Taxa Interna de Rentabilidade (TIR) de 92%. Para isolar o pavimento, sugeriu-se a utilização de placas de poliuretano expandido (PU) de 20mm de espessura. Assim, consegue-se uma poupança de 7.442 €/ano, com um investimento de 21.708€, e um tempo de retorno 2,9 anos. No final do 5º ano de vida útil do projecto, o VAL é de 4.070€ e a TIR 7%. Relativamente ao isolamento das paredes e pilares, sugeriu-se a utilização de placas de PU (30mm), recobertas com chapa de ferro galvanizado. O tempo de retorno do investimento é de 1,5 anos, uma vez que, o investimento é de 13.670€ e a poupança anual será de 9.183€. Esta solução apresenta no último ano um VAL de 12.835€ e uma TIR de 22%. No isolamento das fendas do edifício, sugeriu-se a redução de 20% da sua área livre. Esta medida de optimização implica um investimento de 8.000€, revelando-se suficientemente eficaz, pois apresenta um tempo de retorno de 0,67 anos. O VAL e a TIR da solução no último ano de vida útil do projecto de investimento são de 36.835€ e 35%, respectivamente. Por fim, sugeriu-se ainda a instalação de um sistema de controlo que visa o aproveitamento de ar quente proveniente do forno, instalado no piso inferior à olaria, para pré-aquecer o ar alimentado aos geradores de calor. Esta medida implicaria um investimento de 4.000€, com um tempo de retorno de 2,4 anos e uma poupança anual é de 1.686€. O investimento é aconselhável, já que, no 5º ano, o VAL é de 1.956€ e a TIR é de 17%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Specific marine macro algae species abundant at the Portuguese coast (Laminaria hyperborea, Bifurcaria bifurcata, Sargassum muticum and Fucus spiralis) were shown to be effective for removing toxic metals (Cd(II), Zn(II) and Pb(II)) from aqueous solutions. The initial metal concentrations in solution were about 75–100 mg L−1. The observed biosorption capacities for cadmium, zinc and lead ions were in the ranges of 23.9–39.5, 18.6–32.0 and 32.3–50.4 mg g−1, respectively. Kinetic studies revealed that the metal uptake rate was rather fast, with 75% of the total amount occurring in the first 10 min for all algal species. Experimental data were well fitted by a pseudo-second order rate equation. The contribution of internal diffusion mechanism was significant only to the initial biosorption stage. Results indicate that all the studied macro algae species can provide an efficient and cost-effective technology for eliminating heavy metals from industrial effluents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zero valent iron (ZVI) has been extensively used as a reactive medium for the reduction of Cr(VI) to Cr(III) in reactive permeable barriers. The kinetic rate depends strongly on the superficial oxidation of the iron particles used and the preliminary washing of ZVI increases the rate. The reaction has been primarily modelled using a pseudo-first-order kinetics which is inappropriate for a heterogeneous reaction. We assumed a shrinking particle type model where the kinetic rate is proportional to the available iron surface area, to the initial volume of solution and to the chromium concentration raised to a power ˛ which is the order of the chemical reaction occurring at surface. We assumed α= 2/3 based on the likeness to the shrinking particle models with spherical symmetry. Kinetics studies were performed in order to evaluate the suitability of this approach. The influence of the following parameters was experimentally studied: initial available surface area, chromium concentration, temperature and pH. The assumed order for the reaction was confirmed. In addition, the rate constant was calculated from data obtained in different operating conditions. Digital pictures of iron balls were periodically taken and the image treatment allowed for establishing the time evolution of their size distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the adequacy and the benefit of incorporating glass fibre reinforced polymer (GFRP) waste materials into polyester based mortars, as sand aggregates and filler replacements, are assessed. Different weight contents of mechanically recycled GFRP wastes with two particle size grades are included in the formulation of new materials. In all formulations, a polyester resin matrix was modified with a silane coupling agent in order to improve binder-aggregates interfaces. The added value of the recycling solution was assessed by means of both flexural and compressive strengths of GFRP admixed mortars with regard to those of the unmodified polymer mortars. Planning of experiments and data treatment were performed by means of full factorial design and through appropriate statistical tools based on analyses of variance (ANOVA). Results show that the partial replacement of sand aggregates by either type of GFRP recyclates improves the mechanical performance of resultant polymer mortars. In the case of trial formulations modified with the coarser waste mix, the best results are achieved with 8% waste weight content, while for fine waste based polymer mortars, 4% in weight of waste content leads to the higher increases on mechanical strengths. This study clearly identifies a promising waste management solution for GFRP waste materials by developing a cost-effective end-use application for the recyclates, thus contributing to a more sustainable fibre-reinforced polymer composites industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica Ramo de Processos Químicos

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Civil Área de Especialização em Estruturas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In beacon-enabled mode, IEEE 802.15.4 is ruled by the slotted CSMA/CA Medium Access Control (MAC) protocol. The standard slotted CSMA/CA mechanism does not provide any means of differentiated services to improve the quality of service for timecritical events (such as alarms, time slot reservation, PAN management messages etc.). In this paper, we present and discuss practical service differentiation mechanisms to improve the performance of slotted CSMA/CA for time-critical events, with only minor add-ons to the protocol. The contribution of our proposal is more practical than theoretical since our initial requirement is to leave the original algorithm of the slotted CSMA/CA unchanged, but rather tuning its parameters adequately according to the criticality of the messages. We present a simulation study based on an accurate model of the IEEE 802.15.4 MAC protocol, to evaluate the differentiated service strategies. Four scenarios with different settings of the slotted CSMA/CA parameters are defined. Each scenario is evaluated for FIFO and Priority Queuing. The impact of the hiddennode problem is also analyzed, and a solution to mitigate it is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to discuss the linear solution of equality constrained problems by using the Frontal solution method without explicit assembling. Design/methodology/approach - Re-written frontal solution method with a priori pivot and front sequence. OpenMP parallelization, nearly linear (in elimination and substitution) up to 40 threads. Constraints enforced at the local assembling stage. Findings - When compared with both standard sparse solvers and classical frontal implementations, memory requirements and code size are significantly reduced. Research limitations/implications - Large, non-linear problems with constraints typically make use of the Newton method with Lagrange multipliers. In the context of the solution of problems with large number of constraints, the matrix transformation methods (MTM) are often more cost-effective. The paper presents a complete solution, with topological ordering, for this problem. Practical implications - A complete software package in Fortran 2003 is described. Examples of clique-based problems are shown with large systems solved in core. Social implications - More realistic non-linear problems can be solved with this Frontal code at the core of the Newton method. Originality/value - Use of topological ordering of constraints. A-priori pivot and front sequences. No need for symbolic assembling. Constraints treated at the core of the Frontal solver. Use of OpenMP in the main Frontal loop, now quantified. Availability of Software.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado Engenharia Química. Ramo Tecnologias de Protecção Ambiental

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Remote engineering (also known as online engineering) may be defined as a combination of control engineering and telematics. In this area, specific activities require computacional skills in order to develop projects where electrical devives are monitored and / or controlled, in an intercative way, through a distributed network (e.g. Intranet or Internet). In our specific case, we will be dealing with an industrial plant. Within the last few years, there has been an increase in the number of activities related to remote engineering, which may be connected to the phenomenon of the large extension experienced by the Internet (e.g. bandwith, number of users, development tools, etc.). This increase opens new and future possibilities to the implementation of advance teleworking (or e-working) positions. In this paper we present the architecture for a remote application, accessible through the Internet, able to monitor and control a roller hearth kiln, used in a ceramics industry for firing materials. The proposed architecture is based on a micro web server, whose main function is to monitor and control the firing process, by reading the data from a series of temperature sensors and by controlling a series of electronic valves and servo motors. This solution is also intended to be a low-cost alternative to other potential solutions. The temperature readings are obtained through K-type thermopairs and the gas flow is controlled through electrovalves. As the firing process should not be stopped before its complete end, the system is equipped with a safety device for that specific purpose. For better understanding the system to be automated and its operation we decided to develop a scale model (100:1) and experiment on it the devised solution, based on a Micro Web Server.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of remote labs in undergraduate courses has been reported in literature several times since the mid 90's. Nevertheless, very few articles present results about the correspondent learning gains obtained by students, and in what conditions those systems can be more efficient, thus suggesting a lack of data concerning their pedagogical effectiveness. This paper addresses such a gap by presenting some initial findings concerning the use of a remote lab (VISIR), in a large undergraduate course on Physics, with over 550 students enrolled.