835 resultados para Error correction codes


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Regenerating codes and codes with locality are two coding schemes that have recently been proposed, which in addition to ensuring data collection and reliability, also enable efficient node repair. In a situation where one is attempting to repair a failed node, regenerating codes seek to minimize the amount of data downloaded for node repair, while codes with locality attempt to minimize the number of helper nodes accessed. This paper presents results in two directions. In one, this paper extends the notion of codes with locality so as to permit local recovery of an erased code symbol even in the presence of multiple erasures, by employing local codes having minimum distance >2. An upper bound on the minimum distance of such codes is presented and codes that are optimal with respect to this bound are constructed. The second direction seeks to build codes that combine the advantages of both codes with locality as well as regenerating codes. These codes, termed here as codes with local regeneration, are codes with locality over a vector alphabet, in which the local codes themselves are regenerating codes. We derive an upper bound on the minimum distance of vector-alphabet codes with locality for the case when their constituent local codes have a certain uniform rank accumulation property. This property is possessed by both minimum storage regeneration (MSR) and minimum bandwidth regeneration (MBR) codes. We provide several constructions of codes with local regeneration which achieve this bound, where the local codes are either MSR or MBR codes. Also included in this paper, is an upper bound on the minimum distance of a general vector code with locality as well as the performance comparison of various code constructions of fixed block length and minimum distance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To compare outcomes between adjustable spectacles and conventional methods for refraction in young people. DESIGN: Cross sectional study. SETTING: Rural southern China. PARTICIPANTS: 648 young people aged 12-18 (mean 14.9 (SD 0.98)), with uncorrected visual acuity ≤ 6/12 in either eye. INTERVENTIONS: All participants underwent self refraction without cycloplegia (paralysis of near focusing ability with topical eye drops), automated refraction without cycloplegia, and subjective refraction by an ophthalmologist with cycloplegia. MAIN OUTCOME MEASURES: Uncorrected and corrected vision, improvement of vision (lines on a chart), and refractive error. RESULTS: Among the participants, 59% (384) were girls, 44% (288) wore spectacles, and 61% (393/648) had 2.00 dioptres or more of myopia in the right eye. All completed self refraction. The proportion with visual acuity ≥ 6/7.5 in the better eye was 5.2% (95% confidence interval 3.6% to 6.9%) for uncorrected vision, 30.2% (25.7% to 34.8%) for currently worn spectacles, 96.9% (95.5% to 98.3%) for self refraction, 98.4% (97.4% to 99.5%) for automated refraction, and 99.1% (98.3% to 99.9%) for subjective refraction (P = 0.033 for self refraction v automated refraction, P = 0.001 for self refraction v subjective refraction). Improvements over uncorrected vision in the better eye with self refraction and subjective refraction were within one line on the eye chart in 98% of participants. In logistic regression models, failure to achieve maximum recorded visual acuity of 6/7.5 in right eyes with self refraction was associated with greater absolute value of myopia/hyperopia (P<0.001), greater astigmatism (P = 0.001), and not having previously worn spectacles (P = 0.002), but not age or sex. Significant inaccuracies in power (≥ 1.00 dioptre) were less common in right eyes with self refraction than with automated refraction (5% v 11%, P<0.001). CONCLUSIONS: Though visual acuity was slightly worse with self refraction than automated or subjective refraction, acuity was excellent in nearly all these young people with inadequately corrected refractive error at baseline. Inaccurate power was less common with self refraction than automated refraction. Self refraction could decrease the requirement for scarce trained personnel, expensive devices, and cycloplegia in children's vision programmes in rural China.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The World Health Organization estimates that 13 million children aged 5-15 years worldwide are visually impaired from uncorrected refractive error. School vision screening programs can identify and treat or refer children with refractive error. We concentrate on the findings of various screening studies and attempt to identify key factors in the success and sustainability of such programs in the developing world. We reviewed original and review articles describing children's vision and refractive error screening programs published in English and listed in PubMed, Medline OVID, Google Scholar, and Oxford University Electronic Resources databases. Data were abstracted on study objective, design, setting, participants, and outcomes, including accuracy of screening, quality of refractive services, barriers to uptake, impact on quality of life, and cost-effectiveness of programs. Inadequately corrected refractive error is an important global cause of visual impairment in childhood. School-based vision screening carried out by teachers and other ancillary personnel may be an effective means of detecting affected children and improving their visual function with spectacles. The need for services and potential impact of school-based programs varies widely between areas, depending on prevalence of refractive error and competing conditions and rates of school attendance. Barriers to acceptance of services include the cost and quality of available refractive care and mistaken beliefs that glasses will harm children's eyes. Further research is needed in areas such as the cost-effectiveness of different screening approaches and impact of education to promote acceptance of spectacle-wear. School vision programs should be integrated into comprehensive efforts to promote healthy children and their families.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The scope of this study was to estimate calibrated values for dietary data obtained by the Food Frequency Questionnaire for Adolescents (FFQA) and illustrate the effect of this approach on food consumption data. The adolescents were assessed on two occasions, with an average interval of twelve months. In 2004, 393 adolescents participated, and 289 were then reassessed in 2005. Dietary data obtained by the FFQA were calibrated using the regression coefficients estimated from the average of two 24-hour recalls (24HR) of the subsample. The calibrated values were similar to the the 24HR reference measurement in the subsample. In 2004 and 2005 a significant difference was observed between the average consumption levels of the FFQA before and after calibration for all nutrients. With the use of calibrated data the proportion of schoolchildren who had fiber intake below the recommended level increased. Therefore, it is seen that calibrated data can be used to obtain adjusted associations due to reclassification of subjects within the predetermined categories.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to obtain the exact value of the keratometric index (nkexact) and to clinically validate a variable keratometric index (nkadj) that minimizes this error. Methods: The nkexact value was determined by obtaining differences (DPc) between keratometric corneal power (Pk) and Gaussian corneal power (PGauss c ) equal to 0. The nkexact was defined as the value associated with an equivalent difference in the magnitude of DPc for extreme values of posterior corneal radius (r2c) for each anterior corneal radius value (r1c). This nkadj was considered for the calculation of the adjusted corneal power (Pkadj). Values of r1c ∈ (4.2, 8.5) mm and r2c ∈ (3.1, 8.2) mm were considered. Differences of True Net Power with PGauss c , Pkadj, and Pk(1.3375) were calculated in a clinical sample of 44 eyes with keratoconus. Results: nkexact ranged from 1.3153 to 1.3396 and nkadj from 1.3190 to 1.3339 depending on the eye model analyzed. All the nkadj values adjusted perfectly to 8 linear algorithms. Differences between Pkadj and PGauss c did not exceed 60.7 D (Diopter). Clinically, nk = 1.3375 was not valid in any case. Pkadj and True Net Power and Pk(1.3375) and Pkadj were statistically different (P , 0.01), whereas no differences were found between PGauss c and Pkadj (P . 0.01). Conclusions: The use of a single value of nk for the calculation of the total corneal power in keratoconus has been shown to be imprecise, leading to inaccuracies in the detection and classification of this corneal condition. Furthermore, our study shows the relevance of corneal thickness in corneal power calculations in keratoconus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study examines whether voluntary national governance codes have a significant effect on company disclosure practices. Two direct effects of the codes are expected: 1) an overall improvement in company disclosure practices, which is greater when the codes have a greater emphasis on disclosure; and 2) a leveling out of disclosure practices across companies (i.e., larger improvements in companies that were previously poorer disclosers) due to the codes new comply-or-explain requirements. The codes are also expected to have an indirect effect on disclosure practices through their effect on company governance practices. The results show that the introduction of the codes in eight East Asian countries has been associated with lower analyst forecast error and a leveling out of disclosure practices across companies. The codes are also found to have an indirect effect on company disclosure practices through their effect on board independence. This study shows that a regulatory approach to improving disclosure practices is not always necessary. Voluntary national governance codes are found to have both a significant direct effect and a significant indirect effect on company disclosure practices. In addition, the results indicate that analysts in Asia do react to changes in disclosure practices, so there is an incentive for small companies and family-owned companies to further improve their disclosure practices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Scoliosis is a spinal deformity that requires surgical correction in progressive cases. In order to optimize surgical outcomes, patient-specific finite element models are being developed by our group. In this paper, a single rod anterior correction procedure is simulated for a group of six scoliosis patients. For each patient, personalised model geometry was derived from low-dose CT scans, and clinically measured intra-operative corrective forces were applied. However, tissue material properties were not patient-specific, being derived from existing literature. Clinically, the patient group had a mean initial Cobb angle of 47.3 degrees, which was corrected to 17.5 degrees after surgery. The mean simulated post-operative Cobb angle for the group was 18.1 degrees. Although this represents good agreement between clinical and simulated corrections, the discrepancy between clinical and simulated Cobb angle for individual patients varied between -10.3 and +8.6 degrees, with only three of the six patients matching the clinical result to within accepted Cobb measurement error of +-5 degrees. The results of this study suggest that spinal tissue material properties play an important role in governing the correction obtained during surgery, and that patient-specific modelling approaches must address the question of how to prescribe patient-specific soft tissue properties for spine surgery simulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION. Following anterior thoracoscopic instrumentation and fusion for the treatment of thoracic AIS, implant related complications have been reported as high as 20.8%. Currently the magnitudes of the forces applied to the spine during anterior scoliosis surgery are unknown. The aim of this study was to measure the segmental compressive forces applied during anterior single rod instrumentation in a series of adolescent idiopathic scoliosis patients. METHODS. A force transducer was designed, constructed and retrofitted to a surgical cable compression tool, routinely used to apply segmental compression during anterior scoliosis correction. Transducer output was continuously logged during the compression of each spinal joint, the output at completion converted to an applied compression force using calibration data. The angle between adjacent vertebral body screws was also measured on intra-operative frontal plane fluoroscope images taken both before and after each joint compression. The difference in angle between the two images was calculated as an estimate for the achieved correction at each spinal joint. RESULTS. Force measurements were obtained for 15 scoliosis patients (Aged 11-19 years) with single thoracic curves (Cobb angles 47˚- 67˚). In total, 95 spinal joints were instrumented. The average force applied for a single joint was 540 N (± 229 N)ranging between 88 N and 1018 N. Experimental error in the force measurement, determined from transducer calibration was ± 43 N. A trend for higher forces applied at joints close to the apex of the scoliosis was observed. The average joint correction angle measured by fluoroscope imaging was 4.8˚ (±2.6˚, range 0˚-12.6˚). CONCLUSION. This study has quantified in-vivo, the intra-operative correction forces applied by the surgeon during anterior single rod instrumentation. This data provides a useful contribution towards an improved understanding of the biomechanics of scoliosis correction. In particular, this data will be used as input for developing patient-specific finite element simulations of scoliosis correction surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper "the importance of convexity in learning with squared loss" gave a lower bound on the sample complexity of learning with quadratic loss using a nonconvex function class. The proof contains an error. We show that the lower bound is true under a stronger condition that holds for many cases of interest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Few studies have specifically investigated the functional effects of uncorrected astigmatism on measures of reading fluency. This information is important to provide evidence for the development of clinical guidelines for the correction of astigmatism. Methods: Participants included 30 visually normal, young adults (mean age 21.7 ± 3.4 years). Distance and near visual acuity and reading fluency were assessed with optimal spectacle correction (baseline) and for two levels of astigmatism, 1.00DC and 2.00DC, at two axes (90° and 180°) to induce both against-the-rule (ATR) and with-the-rule (WTR) astigmatism. Reading and eye movement fluency were assessed using standardized clinical measures including the test of Discrete Reading Rate (DRR), the Developmental Eye Movement (DEM) test and by recording eye movement patterns with the Visagraph (III) during reading for comprehension. Results: Both distance and near acuity were significantly decreased compared to baseline for all of the astigmatic lens conditions (p < 0.001). Reading speed with the DRR for N16 print size was significantly reduced for the 2.00DC ATR condition (a reduction of 10%), while for smaller text sizes reading speed was reduced by up to 24% for the 1.00DC ATR and 2.00DC condition in both axis directions (p<0.05). For the DEM, sub-test completion speeds were significantly impaired, with the 2.00DC condition affecting both vertical and horizontal times and the 1.00DC ATR condition affecting only horizontal times (p<0.05). Visagraph reading eye movements were not significantly affected by the induced astigmatism. Conclusions: Induced astigmatism impaired performance on selected tests of reading fluency, with ATR astigmatism having significantly greater effects on performance than did WTR, even for relatively small amounts of astigmatic blur of 1.00DC. These findings have implications for the minimal prescribing criteria for astigmatic refractive errors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To demonstrate that relatively simple third-order theory can provide a framework which shows how peripheral refraction can be manipulated by altering the forms of spectacle lenses. Method: Third-order equations were used to yield lens forms that correct peripheral power errors, either for the lenses alone or in combination with typical peripheral refractions of myopic eyes. These results were compared with those of finite ray-tracing. Results: The approximate forms of spherical and conicoidal lenses provided by third-order theory were flatter over a moderate myopic range than the forms obtained by rigorous raytracing. Lenses designed to correct peripheral refractive errors produced large errors when used with foveal vision and a rotating eye. Correcting astigmatism tended to give large errors in mean oblique error and vice versa. When only spherical lens forms are used, correction of the relative hypermetropic peripheral refractions of myopic eyes which are observed experimentally, or the provision of relative myopic peripheral refractions in such eyes, seems impossible in the majority of cases. Conclusion: The third-order spectacle lens design approach can readily be used to show trends in peripheral refraction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

3D models of long bones are being utilised for a number of fields including orthopaedic implant design. Accurate reconstruction of 3D models is of utmost importance to design accurate implants to allow achieving a good alignment between two bone fragments. Thus for this purpose, CT scanners are employed to acquire accurate bone data exposing an individual to a high amount of ionising radiation. Magnetic resonance imaging (MRI) has been shown to be a potential alternative to computed tomography (CT) for scanning of volunteers for 3D reconstruction of long bones, essentially avoiding the high radiation dose from CT. In MRI imaging of long bones, the artefacts due to random movements of the skeletal system create challenges for researchers as they generate inaccuracies in the 3D models generated by using data sets containing such artefacts. One of the defects that have been observed during an initial study is the lateral shift artefact occurring in the reconstructed 3D models. This artefact is believed to result from volunteers moving the leg during two successive scanning stages (the lower limb has to be scanned in at least five stages due to the limited scanning length of the scanner). As this artefact creates inaccuracies in the implants designed using these models, it needs to be corrected before the application of 3D models to implant design. Therefore, this study aimed to correct the lateral shift artefact using 3D modelling techniques. The femora of five ovine hind limbs were scanned with a 3T MRI scanner using a 3D vibe based protocol. The scanning was conducted in two halves, while maintaining a good overlap between them. A lateral shift was generated by moving the limb several millimetres between two scanning stages. The 3D models were reconstructed using a multi threshold segmentation method. The correction of the artefact was achieved by aligning the two halves using the robust iterative closest point (ICP) algorithm, with the help of the overlapping region between the two. The models with the corrected artefact were compared with the reference model generated by CT scanning of the same sample. The results indicate that the correction of the artefact was achieved with an average deviation of 0.32 ± 0.02 mm between the corrected model and the reference model. In comparison, the model obtained from a single MRI scan generated an average error of 0.25 ± 0.02 mm when compared with the reference model. An average deviation of 0.34 ± 0.04 mm was seen when the models generated after the table was moved were compared to the reference models; thus, the movement of the table is also a contributing factor to the motion artefacts.