674 resultados para ELUTING STENTS


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to describe the process to obtain Food and Drug Administration (FDA) approval for the expanded indication for treatment with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Inc., Santa Rosa, California) in patients with coronary artery disease and diabetes. BACKGROUND The R-ZES is the first drug-eluting stent specifically indicated in the United States for percutaneous coronary intervention in patients with diabetes. METHODS We pooled patient-level data for 5,130 patients from the RESOLUTE Global Clinical Program. A performance goal prospectively determined in conjunction with the FDA was established as a rate of target vessel failure at 12 months of 14.5%. In addition to the FDA pre-specified cohort of less complex patients with diabetes (n = 878), we evaluated outcomes of the R-ZES in all 1,535 patients with diabetes compared with all 3,595 patients without diabetes at 2 years. RESULTS The 12-month rate of target vessel failure in the pre-specified diabetic cohort was 7.8% (upper 95% confidence interval: 9.51%), significantly lower than the performance goal of 14.5% (p < 0.001). After 2 years, the cumulative incidence of target lesion failure in patients with noninsulin-treated diabetes was comparable to that of patients without diabetes (8.0% vs. 7.1%). The higher risk insulin-treated population demonstrated a significantly higher target lesion failure rate (13.7%). In the whole population, including complex patients, rates of stent thrombosis were not significantly different between patients with and without diabetes (1.2% vs. 0.8%). CONCLUSIONS The R-ZES is safe and effective in patients with diabetes. Long-term clinical data of patients with noninsulin-treated diabetes are equivalent to patients without diabetes. Patients with insulin-treated diabetes remain a higher risk subset. (The Medtronic RESOLUTE Clinical Trial; NCT00248079; Randomized, Two-arm, Non-inferiority Study Comparing Endeavor-Resolute Stent With Abbot Xience-V Stent [RESOLUTE-AC]; NCT00617084; The Medtronic RESOLUTE US Clinical Trial (R-US); NCT00726453; RESOLUTE International Registry: Evaluation of the Resolute Zotarolimus-Eluting Stent System in a 'Real-World' Patient Population [R-Int]; NCT00752128; RESOLUTE Japan-The Clinical Evaluation of the MDT-4107 Drug-Eluting Coronary Stent [RJ]; NCT00927940).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE to compare the vascular healing process between the sirolimus-eluting NEVO and the everolimus-eluting Xience stent by optical coherence tomography (OCT) at 1-year follow-up. BACKGROUND Presence of durable polymer on a drug-eluting metallic stent may be the basis of an inflammatory reaction with abnormal healing response. The NEVO stent, having a bioresorbable polymer eluted by reservoir technology, may overcome this problem. METHODS All consecutive patients, who received NEVO or Xience stent implantation between September 2010 and October 2010 in our institution, were included. Vascular healing was assessed at 1-year as percentage of uncovered struts, neointimal thickness (NIT), in-stent/stent area obstruction and pattern of neointima. RESULTS A total 47 patients (2:1 randomization, n = 32 NEVO, n = 15 Xience) were included. Eighteen patients underwent angiographic follow-up (eight patients with nine lesions for NEVO vs. 10 patients with 11 lesions for Xience). The angiographic late loss was numerically higher but not statistically different in NEVO compared with Xience treated lesions (0.38 ± 0.47 mm vs. 0.18 ± 0.27 mm; P = 0.171). OCT analysis of 4,912 struts demonstrated similar rates of uncovered struts (0.5 vs. 0.7%, P = 0.462), higher mean NIT (177.76 ± 87.76 µm vs. 132.22 ± 30.91 µm; P = 0.170) and in stent/stent area obstruction (23.02 ± 14.74% vs. 14.17 ± 5.94%, P = 0.120) in the NEVO as compared with Xience. CONCLUSION The NEVO stent with a reservoir technology seems to exhibit more neointimal proliferation as compared to Xience stent. The findings of our study, which currently represent the unique data existing on this reservoir technology, would need to be confirmed in a large population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The long-term results after second generation everolimus eluting bioresorbable vascular scaffold (Absorb BVS) placement in small vessels are unknown. Therefore, we investigated the impact of vessel size on long-term outcomes, after Absorb BVS implantation. METHODS In ABSORB Cohort B Trial, out of the total study population (101 patients), 45 patients were assigned to undergo 6-month and 2-year angiographic follow-up (Cohort B1) and 56 patients to have angiographic follow-up at 1-year (Cohort B2). The pre-reference vessel diameter (RVD) was <2.5 mm (small-vessel group) in 41 patients (41 lesions) and ≥2.5 mm (large-vessel group) in 60 patients (61 lesions). Outcomes were compared according to pre-RVD. RESULTS At 2-year angiographic follow-up no differences in late lumen loss (0.29±0.16 mm vs 0.25±0.22 mm, p=0.4391), and in-segment binary restenosis (5.3% vs 5.3% p=1.0000) were demonstrated between groups. In the small-vessel group, intravascular ultrasound analysis showed a significant increase in vessel area (12.25±3.47 mm(2) vs 13.09±3.38 mm(2) p=0.0015), scaffold area (5.76±0.96 mm(2) vs 6.41±1.30 mm(2) p=0.0008) and lumen area (5.71±0.98 mm(2) vs 6.20±1.27 mm(2) p=0.0155) between 6-months and 2-year follow-up. No differences in plaque composition were reported between groups at either time point. At 2-year clinical follow-up, no differences in ischaemia-driven major adverse cardiac events (7.3% vs 10.2%, p=0.7335), myocardial infarction (4.9% vs 1.7%, p=0.5662) or ischaemia-driven target lesion revascularisation (2.4% vs 8.5%, p=0.3962) were reported between small and large vessels. No deaths or scaffold thrombosis were observed. CONCLUSIONS Similar clinical and angiographic outcomes at 2-year follow-up were reported in small and large vessel groups. A significant late lumen enlargement and positive vessel remodelling were observed in small vessels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Angiographic evidence of edge dissections has been associated with a risk of early stent thrombosis. Optical coherence tomography (OCT) is a high-resolution technology detecting a greater number of edge dissections -particularly non-flow-limiting- compared to angiography. Their natural history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. Methods and results: Edge dissections were defined as disruptions of the luminal surface in the 5 mm segments proximal and distal to the stent, and categorised as flaps, cavities, double-lumen dissections or fissures. Qualitative and quantitative OCT analyses were performed every 0.5 mm at baseline and one year, and clinical outcomes were assessed. Sixty-three lesions (57 patients) were studied with OCT at baseline and one-year follow-up. Twenty-two non-flow-limiting edge dissections in 21 lesions (20 patients) were identified by OCT; only two (9%) were angiographically visible. Flaps were found in 96% of cases. The median longitudinal dissection length was 2.9 mm (interquartile range [IQR] 1.6-4.2 mm), whereas the circumferential and axial extensions amounted to 1.2 mm (IQR: 0.9-1.7 mm) and 0.6 mm (IQR: 0.4-0.7 mm), respectively. Dissections extended into the media and adventitia in seven (33%) and four (20%) cases, respectively. Eighteen (82%) OCT-detected edge dissections were also evaluated with intravascular ultrasound which identified nine (50%) of these OCT-detected dissections. No stent thrombosis or target lesion revascularisation occurred up to one year. At follow-up, 20 (90%) edge dissections were completely healed on OCT. The two cases exhibiting persistent dissection had the longest flaps (2.81 mm and 2.42 mm) at baseline. Conclusions: OCT-detected edge dissections which are angiographically silent in the majority of cases are not associated with acute stent thrombosis or restenosis up to one-year follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 69-year-old male (case 1) was admitted due to acute non-ST-segment elevation myocardial infarction (NSTEMI). Eight years earlier, he had previously undergone treatment with a sirolimus-eluting stent (SES). Four years after stent implantation, a follow-up angiography was obtained showing a patent stent without obstructive in-stent restenosis (Panel A). Angiograms obtained at the time of NSTEMI (Panel B) disclosed subtotal occlusion in the middle of the SES (arrowheads). Optical coherence tomography revealed a signal intense luminal layer with an underlying, highly attenuating, diffusely demarcated area, suggestive for an instent fibroatheroma (Panel D) with a minimal cap thickness of 80 µm. Accordingly, ischaemia was caused by the high degree of stenosis (Panel E). Similarly, a 59-year-old male (case 2) was admitted due to STEMI. Nine years before, he had received a paclitaxel-eluting stent (PES). Five years after stent implantation, a follow-up angiography revealed a patent stent (Panel F). Angiograms obtained at the time of STEMI (Panel G) disclosed total occlusion in the proximal of PES (arrowheads). Optical coherence tomography showed a rupture of thin cap fibroatheroma within the stented segment (Panel I). The thin cap fibroatheroma caused a severe stenosis with superimposed thrombus (Panel J). Neoatherosclerosis has been recently described as particular disease entity being responsible for very late stent failures. These two cases illustrate that the presence of a favourable long-term angiographic result years after DES implantation does not exclude a future neoatherosclerosis-related event (restenosis or stent thrombosis). Large observational and long-term intracoronary imaging studies are required to fully elucidate the dynamics and clinical relevance of neoatherosclerosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT. METHODS AND RESULTS: In 50 stents of 28 patients (mean age 64 ± 10 years) undergoing coronary CT angiography (CCTA) on an HDCT scanner the mean in-stent luminal diameter, stent length, image quality, in-stent contrast attenuation, and image noise were assessed. Studies were reconstructed using filtered back projection (FBP) and ASIR-FBP composites. ASIR resulted in reduced image noise vs. FBP (P < 0.0001). Two readers graded the CCTA stent image quality on a 4-point Likert scale and determined the proportion of interpretable stent segments. The best image quality for all clinical images was obtained with 40 and 60% ASIR with significantly larger luminal area visualization compared with FBP (+42.1 ± 5.4% with 100% ASIR vs. FBP alone; P < 0.0001) while the stent length was decreased (-4.7 ± 0.9%,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The effectiveness and durability of endovascular revascularization therapies for chronic critical limb ischemia (CLI) are challenged by the extensive burden of infrapopliteal arterial disease and lesion-related characteristics (e.g., severe calcification, chronic total occlusions), which frequently result in poor clinical outcomes. While infrapopliteal vessel patency directly affects pain relief and wound healing, sustained patency and extravascular care both contribute to the ultimate "patient-centric" outcomes of functional limb preservation, mobility and quality of life (QoL). METHODS/DESIGN IN.PACT DEEP is a 2:1 randomized controlled trial designed to assess the efficacy and safety of infrapopliteal arterial revascularization between the IN.PACT Amphirion™ paclitaxel drug-eluting balloon (IA-DEB) and standard balloon angioplasty (PTA) in patients with Rutherford Class 4-5-6 CLI. DISCUSSION This multicenter trial has enrolled 358 patients at 13 European centers with independent angiographic core lab adjudication of the primary efficacy endpoint of target lesion late luminal loss (LLL) and clinically driven target lesion revascularization (TLR) in major amputation-free surviving patients through 12-months. An independent wound core lab will evaluate all ischemic wounds to assess the extent of healing and time to healing at 1, 6, and 12 months. A QoL questionnaire including a pain scale will assess changes from baseline scores through 12 months. A Clinical Events Committee and Data Safety Monitoring Board will adjudicate the composite primary safety endpoints of all-cause death, major amputation, and clinically driven TLR at 6 months and other trial endpoints and supervise patient safety throughout the study. All patients will be followed for 5 years. A literature review is presented of the current status of endovascular treatment of CLI with drug-eluting balloon and standard PTA. The rationale and design of the IN.PACT DEEP Trial are discussed. IN.PACT DEEP is a milestone, prospective, randomized, robust, independent core lab-adjudicated CLI trial that will evaluate the role of a new infrapopliteal revascularization technology, the IA-DEB, compared to PTA. It will assess the overall impact on infrapopliteal artery patency, limb salvage, wound healing, pain control, QoL, and patient mobility. The 1-year results of the adjudicated co-primary and secondary endpoints will be available in 2014. TRIAL REGISTRATION NCT00941733

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES This study sought to determine the effect of rotational atherectomy (RA) on drug-eluting stent (DES) effectiveness. BACKGROUND DES are frequently used in complex lesions, including calcified stenoses, which may challenge DES delivery, expansion, and effectiveness. RA can adequately modify calcified plaques and facilitate stent delivery and expansion. Its impact on DES effectiveness is widely unknown. METHODS The ROTAXUS (Rotational Atherectomy Prior to TAXUS Stent Treatment for Complex Native Coronary Artery Disease) study randomly assigned 240 patients with complex calcified native coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120, standard therapy group). Stenting was performed using a polymer-based slow-release paclitaxel-eluting stent. The primary endpoint was in-stent late lumen loss at 9 months. Secondary endpoints included angiographic and strategy success, binary restenosis, definite stent thrombosis, and major adverse cardiac events at 9 months. RESULTS Despite similar baseline characteristics, significantly more patients in the standard therapy group were crossed over (12.5% vs. 4.2%, p = 0.02), resulting in higher strategy success in the rotablation group (92.5% vs. 83.3%, p = 0.03). At 9 months, in-stent late lumen loss was higher in the rotablation group (0.44 ± 0.58 vs. 0.31 ± 0.52, p = 0.04), despite an initially higher acute lumen gain (1.56 ± 0.43 vs. 1.44 ± 0.49 mm, p = 0.01). In-stent binary restenosis (11.4% vs. 10.6%, p = 0.71), target lesion revascularization (11.7% vs. 12.5%, p = 0.84), definite stent thrombosis (0.8% vs. 0%, p = 1.0), and major adverse cardiac events (24.2% vs. 28.3%, p = 0.46) were similar in both groups. CONCLUSIONS Routine lesion preparation using RA did not reduce late lumen loss of DES at 9 months. Balloon dilation with only provisional rotablation remains the default strategy for complex calcified lesions before DES implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND To investigate the performance of the MI Sxscore in a multicentre randomised trial of patients undergoing primary percutaneous coronary intervention (PPCI). METHODS AND RESULTS The MI Sxscore was prospectively determined among 1132 STEMI patients enrolled into the COMFORTABLE AMI trial, which randomised patients to treatment with bare-metal (BMS) or biolimus-eluting (BES) stents. Patient- (death, myocardial infarction, any revascularisation) and device-oriented (cardiac death, target-vessel MI, target lesion revascularisation) major adverse cardiac events (MACEs) were compared across MI Sxscore tertiles and according to stent type. The median MI SXscore was 14 (IQR: 9-21). Patients were divided into tertiles of Sxscorelow (≤10), Sxscoreintermediate (11-18) and Sxscorehigh (≥19). At 1year, patient-oriented MACE occurred in 15% of the Sxscorehigh, 9% of the Sxscoreintermediate and 5% of the Sxscorelow tertiles (p<0.001), whereas device-oriented MACE occurred in 8% of the Sxscorehigh, 6% of the Sxscoreintermediate and 4% of the Sxscorelow tertiles (p=0.03). Addition of the MI Sxscore to the TIMI risk score improved prediction of patient- (c-statistic value increase from 0.63 to 0.69) and device-oriented MACEs (c-statistic value increase from 0.65 to 0.70). Differences in the risk for device-oriented MACE between BMS and BES were evident among Sxscorehigh (13% vs. 4% HR 0.33 (0.15-0.74), p=0.007 rather than those in Sxscorelow: 4% vs. 3% HR 0.68 (0.24-1.97), p=0.48) tertiles. CONCLUSIONS The MI Sxscore allows risk stratification of patient- and device-oriented MACEs among patients undergoing PPCI. The addition of the MI Sxscore to the TIMI risk score is of incremental prognostic value among patients undergoing PPCI for treatment of STEMI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Little is known on the "very" long-term incidence of major adverse cardiac events (MACE), target-lesion revascularization (TLR), target-vessel revascularization and stent thrombosis after sirolimus-eluting stent (SES) implantation. We present the first study to provide a 10-year clinical follow-up in an unselected patient population who underwent SES implantation. METHODS AND RESULTS: We ran a systematic 10-year clinical follow-up in a series of 200 consecutive patients treated with unrestricted SES implantation between April 2002 and April 2003 in two Swiss hospitals. Outcomes and follow-up were obtained in all 200 patients. The cumulative 10-year MACE rate was 47% with all-cause death of 20%, cardiac death of 9%, myocardial infarction of 7%, TLR and target-vessel revascularization of 8% and 11% respectively. Academic Research Consortium-defined "definite and probable" stent thrombosis-rate was 2.5%. TLR risk was maximal between 3 to 6 years. New lesion revascularization increased throughout the study period. CONCLUSION: Incidence of TLR was maximal 3 to 6 years after SES implantation and decreased thereafter. MACE and non-TLR revascularization rates steadily increased during the complete follow-up underlining the progression of coronary artery disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was designed to describe a novel approach to the treatment of tracheal collapse (TC) in dogs using self-expandable nitinol stents. Medical records were reviewed retrospectively for 26 client owned dogs in which nitinol stents were deployed. The entire length of trachea was supported independently of the extent of TC. Two overlapping stents were used instead of one in cases where one stent was not spanning the entire trachea adequately. The diameter of the cranial radiolucent portion of trachea, just behind the cricoid cartilage, was measured as a specific landmark to select the appropriate size of the stent. Two self-expandable nitinol stents were inserted in 9 of 26 dogs; the trachea in the rest of the cases was supported with only one stent. A follow up tracheoscopy was performed in 10 of 26 cases with recurrent clinical signs. Secondary tracheal stenosis in these cases was caused by stent fracture, granuloma or excessive stent shortening. Additional stents were placed successfully to expand the stenotic lumen. A support of the entire trachea may decrease risk of nitinol fracture at the end of the implant. Long term clinical improvement (25 of 26 dogs, 96 %) is comparable with the results of other studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up. METHODS The LEADERS trial is a multicentre all-comer study, where patients (n=1707) were randomised to percutaneous intervention with either BES containing biodegradable polymer or SES containing durable polymer. Out of 1707 patients enrolled in this trial, 573 patients had percutaneous coronary intervention for AMI (BES=280, SES=293) and were included in the current analysis. Patient-oriented composite endpoint (POCE, including all death, all myocardial infarction (MI) and all revascularisations), major adverse cardiac events (MACE, including cardiac death, MI and clinically indicated target vessel revascularisation) and stent thrombosis were assessed at 5-year follow-up. RESULTS The baseline clinical, angiographic and procedural characteristics were well matched between BES and SES groups. In all patients with AMI, coronary intervention with a BES, compared with SES, significantly reduced POCE (28.9% vs 42.3%; relative risk (RR) 0.61, 95% CI 0.47 to 0.82, p=0.001) at 5-year follow-up. There was also a reduction in MACE rate in the BES group (18.2% vs 25.9%; RR 0.67, 95% CI 0.47 to 0.95, p=0.025); however, there was no difference in cardiac death and stent thrombosis. In patients with ST-elevation MI (STEMI), coronary intervention with BES significantly reduced POCE (24.4% vs 39.3%; RR 0.55, 95% CI 0.36 to 0.85, p=0.006), MACE (12.6% vs 25.0%; RR 0.47, 95% CI 0.26 to 0.83, p=0.008) and cardiac death (3.0% vs 11.4%; RR 0.25, 95% CI 0.08 to 0.75, p=0.007), along with a trend towards reduction in definite stent thrombosis (3.7% vs 8.6%; RR 0.41, 95% CI 0.15 to 1.18, p=0.088), compared with SES. CONCLUSIONS BES, compared with SES, significantly improved safety and efficacy outcomes in patients with AMI, especially those with STEMI, at 5-year follow-up. TRIAL REGISTRATION NUMBER NCT 00389220.