904 resultados para EFFLUENT


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, kriging with covariates is used to model and map the spatial distribution of salinity measurements gathered by an autonomous underwater vehicle in a sea outfall monitoring campaign aiming to distinguish the effluent plume from the receiving waters and characterize its spatial variability in the vicinity of the discharge. Four different geostatistical linear models for salinity were assumed, where the distance to diffuser, the west-east positioning, and the south-north positioning were used as covariates. Sample variograms were fitted by the Mat`ern models using weighted least squares and maximum likelihood estimation methods as a way to detect eventual discrepancies. Typically, the maximum likelihood method estimated very low ranges which have limited the kriging process. So, at least for these data sets, weighted least squares showed to be the most appropriate estimation method for variogram fitting. The kriged maps show clearly the spatial variation of salinity, and it is possible to identify the effluent plume in the area studied. The results obtained show some guidelines for sewage monitoring if a geostatistical analysis of the data is in mind. It is important to treat properly the existence of anomalous values and to adopt a sampling strategy that includes transects parallel and perpendicular to the effluent dispersion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O tratamento das águas residuais domésticas surge com o intuito de degradar os poluentes presentes, para que as águas residuais tratadas não prejudiquem o ambiente nem a saúde pública. O presente trabalho teve como objetivo a conceção e o dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) na freguesia de Canelas com a finalidade de substituir a já existente e permitir a ampliação da área da rede de saneamento da freguesia. Foram considerados dois tipos de ETAR’s, compacta e convencional, para tratar águas residuais domésticas de aproxidamente 2000 habitantes, com um caudal médio de 400 m3/dia e um caudal de ponta de 1136,7 m3/dia. Das duas opções optou-se pela convencional uma vez que acarreta um menor investimento, no valor de 187 232 €, e se considera também mais adequada às características do efluente a tratar. O tratamento escolhido inclui inicialmente uma gradagem, com uma grade constituída por sete barras com um espaçamento de 20 mm entre elas, seguida de um tamisador rotativo com uma abertura de malha de 3 mm. Depois do tamisador, optou-se por um sistema de desarenação/desengorduramento com um volume do tanque de 3,95 m3 e um fluxo de ar de 17,9 m3/h. Na fase seguinte considerou-se um tratamento biológico por lamas ativadas em regime de arejamento prolongado num tanque de arejamento de volume igual a 245,8 m3 com um arejador submerso, seguindo-se um decantador secundário de volume 33,3 m3. Por último, escolheu-se um sistema de desinfeção por ultravioleta e, a montante do mesmo, um filtro rápido para eliminar pequenas partículas que o efluente ainda possa conter. Para a desinfeção foram consideradas duas secções com cinco módulos de duas lâmpadas cada, ou seja, vinte lâmpadas ultravioleta. Dos resíduos produzidos pelo tratamento da água residual, os gradados e as areias serão encaminhados para aterro, enquanto que as lamas serão enviadas para a ETAR das Termas de S.Vicente, para que sofram o tratamento adequado e sejam encaminhadas para o destinal final adequado (aplicação em solos agrícolas, compostagem ou em alternativa para aterro). No caso da ETAR covencional foi ainda avaliada a possível reutilização de um decantador da ETAR de Milhundos uma vez que esta se encontrava em fase de desativação. Desta avaliação, concluiu-se que não seria economicamente viável o seu reaproveitamento. Mestrado em Engenharia Química – Tecnologias de Proteção Ambiental Para além disso realizou-se também um levantamento dos principais problemas que ocorrem na maioria das ETAR’s e foram apresentadas as respetivas sugestões de resolução. A realização de um inquérito permititu concluir que os odores são o problema que mais causa incómodo à população.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A atividade humana e industrial usa a água para as suas atividades do quotidiano. A água é um recurso natural escasso cuja qualidade deve ser protegida, defendida, gerida e tratada em conformidade com o seu uso. Nesse âmbito, a gestão das águas prossegue objetivos de proteção da saúde humana e de preservação, proteção e melhoria da qualidade do ambiente[1]. Desde o final do seculo XIX até aos dias de hoje, verificou-se uma forte evolução nos sistemas de tratamento de águas residuais. Esta evolução foi fundamental para dar resposta às maiores exigências de qualidade do efluente tratado. O sistema de lamas ativadas é um dos processos de tratamento biológico das águas residuais mais usados em todo o mundo. Este trabalho consiste no desenvolvimento do projeto de conceção e dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) para servir um pequeno aglomerado de cerca de 3200 habitantes equivalentes (hab.eq.), tendo como objetivo o dimensionamento de todas as etapas de tratamento necessárias ao cumprimento da legislação em vigor para a descarga das águas residuais urbanas no meio recetor. O Decreto-lei nº 152/97[2], relativo ao tratamento de águas residuais urbanas, juntamente com o Decreto-lei nº 149/2004[3] que identifica as zonas sensíveis e de zonas menos sensíveis, permitem que as entidades licenciadoras definam o grau de tratamento que a instalação deve possuir tendo em consideração a classificação do meio onde o efluente tratado é descarregado. O Decreto-Lei n.º 135/2009[1] estabelece o regime de identificação, gestão, monitorização e classificação da qualidade das águas balneares, impondo a qualidade microbiológica da água residual tratada mediante o meio recetor, e portanto conseguindo-se assim definir o tratamento de desinfeção a adotar. Resumidamente, a conceção do tratamento focou as seguintes etapas: tratamento preliminar formado por uma unidade compacta de tamisação, desarenador e desengordurador, tratamento secundário por lamas ativadas em regime de arejamento prolongado constituído por dois reatores com cerca de 400 m3 de volume seguido de um decantador com um diâmetro de 9.5 m, tratamento terciário de desinfeção composto por uma microtamisação seguido de desinfeção UV, e a utilização das operações comuns de espessamento e desidratação das lamas produzidas em excesso pelo tratamento, constituída por com um espessador gravítico com 4.6 m de diâmetro, e um filtro banda para a desidratação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho teve como objectivo a minimização do impacto ambiental do processo de curtume da pele de bovino. A indústria de curtumes transforma a pele, material putrescível, em couro, material nobre, termicamente estável e imputrescível. A transformação da pele em couro origina uma carga poluente apreciável quer quanto a efluentes líquidos quer quanto a resíduos sólidos. O fluxo produtivo da indústria de curtumes pode dividir-se em quatro sectores: ribeira, curtume, tinturaria e acabamento, sendo que os três primeiros geram efluentes líquidos com elevada carga poluente. Neste trabalho, foram avaliadas as fases do processo que geram efluentes líquidos: molho, caleiro, curtume e tinturaria. Na avaliação do processo do molho testou-se uma protease e uma lipase contra um molhante e um desengordurante tradicional, agentes químicos normalmente utilizados no molho mas menos biodegradáveis que as enzimas testadas. Salienta-se o bom resultado obtido quanto à eficiência do molho Na avaliação do processo de caleiro testaram-se várias alternativas no sentido da redução da quantidade de sulfureto de sódio utilizada e da minimização da carga poluente. Entre as alternativas, depilação por oxidação, depilação enzimática com e sem destruição do pêlo, elegeu-se a depilação enzimática sem destruição do pêlo que conduziu a resultados com menor impacto ambiental, nomeadamente a redução da % da quantidade de sulfureto de sódio, sendo a redução da carga poluente de 4,19 % de sulfureto, 32.80% de sólidos suspensos totais (SST),27.09% de sólidos totais (ST) e de 76.90% da carência química de oxigénio (CQO) no efluente de caleiro. No processo do curtume da pele é utilizado crómio como agente de curtume em cerca de 80% das peles tratadas, sendo este metal problemático em termos ambientais. No sentido de reduzir a quantidade de crómio utilizada no processo foi realizado um planeamento factorial onde as variáveis a estudar foram a concentração de crómio e a temperatura, tendo este como objectivo observar qual a quantidade mínima de crómio necessária para termos um produto final nas condições desejadas e gerando um menor impacto ambiental. Concluiu-se desenvolvendo um processo que mostra ser possível reduzir a quantidade de sal de crómio de 7% para 5%, além de ter um impacto ambiental claramente menos agressivo nos efluentes de curtume gerado. Este processo quando comparado com o processo tradicional permite a redução de 27% na CQO, 79% nos SST, 11% nos ST e 38% no teor de crómio Na avaliação do processo de tinturaria foi estudado um processo compacto contra o processo tradicional, tendo-se concluído pelo menor impacto ambiental do processo estudado, nomeadamente ao nível da redução do consumo de água e da carga poluente gerada. A comparação dos dois processos, no que respeita à carga poluente gerada, permitiu concluir por uma redução de 39% da CQO, 50% dos SST, e 12% dos ST quando aplicado o processo compacto Por fim foi feita uma avaliação do impacto ambiental do efluente global gerado pelos processos considerados com menor impacto ambiental contra o processo tradicional, normalmente aplicado na indústria. A aplicação do conjunto dos processos desenvolvidos, quando comparada com a aplicação do conjunto dos processos tradicionais, mostra uma redução de 1% no sulfureto, 40% na CQO, 60 % nos SST, 42 % no crómio e 11% nos ST, mostrando claramente que é possível reduzir a carga poluente da indústria de curtumes atuando no processo. Este trabalho mostrou a importância de atuar no processo para minimizar os custos de tratamento e mesmo de investimento dos efluentes da indústria de curtumes. Importa salientar que os processos desenvolvidos necessitam de validação a uma escala semi-industrial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of swine wastewater-derived biogas on microalgae productivity were determined. Experiments were conducted in a closed photobioreactor containing digestate effluent as culturing media and biogas in the headspaceas source of CO2. Experiments were carried out under mixothrophic and autothrophic conditions. Results showed that autotrophic growth rate (0.6 d-1)was twofoldfaster than mixotrophic. Frequent reinjections of biogas containing up to 2,000 ppm of hydrogen sulfide was not inhibitory to microalgae growth. The rapid removal of H2S in the system suggests photobioreactors can be an interesting alternative to biogas purification. A model to estimate microalgae productivity based on the amount of available CO2, inorganic and organic carbon was developedand showed good data fit correlation (r²= 0.99).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Phycoremediation of swine wastewaters has been widely reported as an attractive tertiary treatment system, that effectively removes the excessive nutrient loadswhilst offering a valuable source of feedstock biomass. Digestate from an upflow anaerobic sludge blanket (UASB, 6%v/v) and a nitrification reactor (NR; 50% v/v) were used as culturing media to microalgae. Experiments were carried out in lab scale photobioreactors (PBRs) using a consortia of Chlorella and Scenedesmus. Ammonia (44 to 90%) and phosphorus (77%) were efficiently removed from both effluents tested after 4 days. Microalgae biomass harvested from the UASB effluent showed 57, 34 and 1% of proteins, carbohydrates and lipids, respectively. Comparatively, the cellular composition of microalgae grown on NR effluent had lower protein (43%) but higher carbohydrate (42%) contents. Negligible difference in lipid fraction was observed independently of the effluents tested. The results suggest that the biomass harvested from phycoremediation of swine wastewaters can offer a valuable protein and carbohydrate feedstock for nutritional and biotechnological applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Engineering and Technology Sciences, Biotechnology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation to obtain the degree of Master in Chemical and Biochemical Engineering

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pharmaceuticals and personal care products (PPCPs) are widely used on a daily basis. After their usage they reach the wastewater treatment plants (WWTPs). These compounds have different physico-chemical characteristics, which makes them difficult to completely remove in the WWTPs, througth conventional treatments. Currently, there is no legislation regarding PPCPs thresholds in effluent discharge. But, even at vestigial concentrations, these compounds enclose environmental risks due to, e.g., endocrine disruption potential. There is a need of alternative techniques for their removal in WWTPs. The main goal of this work was to assess the use of electrodialytic (ED) process to remove PPCPs from the effluent to be discharged. A two-compartment ED cell was used testing (i) the effluent position in the cell (anode and cathode compartment); (ii) the use of anion (AEM) and cation exchange membrane (CEM); (iii) the treatment period (6, 12 and 24 hours); (iv) effluent recirculation and current steps; (v) the feasibility of sequential treatments. Phosphorus (P) removal from effluent and energetic costs associated to the process were also evaluated. Five PPCPs were studied – caffeine (CAF), bisphenol A (BPA), 17 β-estradiol (E2), ethinyl estradiol (EE2) and oxybenzone (MBPh). The ED process showed to be effective in the removal when effluent is in the anode compartment. Oxidation is suggested to be the main removal process, which was between 88 and 96%, for all the compounds, in 6 hours. Nevertheless, the presence of intermediates and/or by-products was also observed in some cases. Effluent recirculation should have a retention time in the ED cell big enough to promote removal whereas the current steps (effluent in anode compartment) slightly increased removal efficiencies (higher than 80% for all PPCPs). The sequential set of ED treatment (effluent in anode compartment) showed to be effective during both periods with a removal percentage between 80 and 95% and 73 to 88% in the case of AEM and CEM, respectively. Again, the main removal process is strongly suggested to be oxidation in the anode compartment. However, there was an increase of BOD5 and COD, which might be explained by effluent spiking, these parameters limiting the effluent discharge. From these treatments, the use of AEM, enhanced the P removal from effluent to minimize risk of eutrophication. Energetic costs of the best set-up (6 hours) are approximately 0,8€/m3 of wastewater, a value considered low, attending to the prices of other treatment processes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hepatitis E virus (HEV) is responsible for many enterically transmitted viral hepatitides around the world. It is currently one of the waterborne diseases of global concern. In industrialized countries, HEV appears to be more common than previously thought, even if it is rarely virulent. In Switzerland, seroprevalence studies revealed that HEV is endemic, but no information was available on its environmental spread. The aim of this study was to investigate -using qPCR- the occurrence and concentration of HEV and three other viruses (norovirus genogroup II, human adenovirus-40 and porcine adenovirus) in influents and effluents of 31 wastewater treatment plants (WWTPs) in Switzerland. Low concentrations of HEV were detected in 40 out of 124 WWTP influent samples, showing that HEV is commonly present in this region. The frequency of HEV occurrence was higher in summer than in winter. No HEV was detected in WWTP effluent samples, which indicates a low risk of environmental contamination. HEV occurrence and concentrations were lower than those of norovirus and adenovirus. The autochthonous HEV genotype 3 was found in all positive samples, but a strain of the non-endemic and highly pathogenic HEV genotype I was isolated in one sample, highlighting the possibility of environmental circulation of this genotype. A porcine fecal marker (porcine adenovirus) was not detected in HEV positive samples, indicating that swine are not the direct source of HEV present in wastewater. Further investigations will be necessary to determine the reservoirs and the routes of dissemination of HEV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study has been conducted focusing on how the phosphorus renrx)val efficiency of a constructed wetland (CW) can be optimized through the selective enrichment of the substratum. Activated alumina and powdered iron were examined as possible enrichment compounds. Using packed glass column trials it was found that alumina was not suitable for the renx)val of ortho-phosphate from solution, while mixtures of powdered iron and quartz sand proved to be very efficient. The evaluation of iron/sand mixtures in CWs planted with cattails was performed in three stages; first using an indoor lab scale wetland, then an outdoor lab scale wetland, and finally in a small scale pilot project. For the lab scale tests, three basic configurations were evaluated: using the iron/sand as a pre-filter, in the root bed. and as a post filter. Primary lagoon effluent was applied to the test cells to simulate actual CW conditions, and the total phosphorus and iron concentrations of the influent and effluent were nfK)nitored. The pilot scale trials were limited to using only a post filter design, due to in-progress research at the pilot site. The lab scale tests achieved average renrK>val efficiencies greater than 91% for all indoor configurations, and greater than 97% for all outdoor configurations. The pilot scale tests had an average renK)val efficiency of 60%. This relatively low efficiency in the pilot scale can be attributed to the post filters being only one tenth the size of the lab scale test in terms of hydraulic loading (6 cm/day vs. 60 cm/day).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The original objective of this work was to provide a simple generator w.hich would produce hydrogen torLfuel-cell feed and which could be operated under remote or northern conditions. A secondary objective was to maximize the yield of hydrogen and carbon monoxide from available feed-stocks. A search of the patent literature has indicated that the concept of a small Wulff-type generator is essentially sound and that hydrogen may be recovered from a wide variety of hydrocarbon feed-stocks. A simple experimental set-up has been devised, patterned after ~~t originally used by R. G. Wulff for producing acetylene. This provides a supply of feed-stock, with or Without a carrier gas, which may be passed directly through a heated tube, which may contain a catalyst. A suitable procedure has been devised for analysi~ effluent gases for hydrogen, oxygen, nitrogen, methane and carbon monoxide by gas chromatography with the column packed with .Molecular .:>ieve .5 4. Athanol with air a.s carrier gas and at the same time as oxidant o was thermolyzed at temperatures in the ra~e 700-1100 C, with or Wi~lout catalyst. Methanol with or without nitrogen as a carrier gas was also cracked with • the same type of reactor refractory tube, but the temperature range was lower t down to ,300 " C when a catalyst was used. The problems of converting methane to hydrogen and carbon monoxide effiCiently, using air and/or water as oxidants were also studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect that plants {Typha latifolia) as well as root-bed medium physical and chemical characteristics have on the treatment of primary treated domestic wastewater within a vertical flow constructed wetland system was investigated. Five sets of cells, with two cells in each set, were used. Each cell was made of concrete and measured 1 .0 m X 1 .0 m and was 1.3 m deep. Four different root-bed media were tested : Queenston Shale, Fonthill Sand, Niagara Shale and a Michigan Sand. Four of the sets contained plants and a single type of root-bed medium. The influence of plants was tested by operating a Queenston Shale set without plants. Due to budget constraints no replicates were constructed. All of the sets were operated independently and identically for twenty-eight months. Twelve months of data are presented here, collected after 16 months of continuous operation. Root-bed medium type did not influence BOD5 removal. All of the sets consistently met Ontario Ministry of Environment (MOE) requirements (<25 mg/L) for BOD5 throughout the year. The 12 month average BOD5 concentration from all sets with plants was below 2.36 mg/L. All of the sets were within MOE discharge requirements (< 25 mg/L) for suspended solids with set effluent concentrations ranging from 1.53 to 14.80 mg/L. The Queenston Shale and Fonthill Sand media removed the most suspended solids while the Niagara Shale set produced suspended solids. The set containing Fonthill Sand was the only series to meet MOE discharge requirements (< Img/L) for total phosphorus year-round with a twelve month mean effluent concentration of 0.23 mg/L. Year-round all of the root-bed media were well below MOE discharge requirements (< 20mg/L in winter and < 10 mg/L in sumnner) for ammonium. The Queenston Shale and Fonthill Sand sets removed the most total nitrogen. Plants had no effect on total nitrogen removal, but did influence how nitrogen was cycled within the system. Plants increased the removal of suspended solids by 14%, BOD5 by 10% and total phosphorus by 22%. Plants also increased the amount of dissolved oxygen that entered the system. During the plant growing season removal of total phosphorus was better in all sets with plants regardless of media type. The sets containing Queenston Shale and Fonthill Sand media achieved the best results and plants in the Queenston Shale set increased treatment efficiency for every parameter except nitrogen. Vertical flow wetland sewage treatment systems can be designed and built to consistently meet MOE discharge requirements year-round for BOD5, suspended solids, total phosphorus and ammonium. This system Is generally superior to the free water systems and sub-surface horizontal flow systems in cold climate situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some Ecological Factors Affecting the Input and Population Levels of Total and Faecal Coliforms and Salmonella in Twelve Mile Creek, Lake Ontario and Sewage Waters Near St. Catharines, Ontario. Supervisor: Dr. M. Helder. The present study was undertaken to investigate the role of some ecological factors on sewage-Dorne bacteria in waters near St. Catharines, Ontario. Total and faecal coliform levels and the presence of Salmonella were monitored for a period of a year along with determination of temperature, pH, dissolved oxygen, total dissolved solids, nitrate N, total phosphate P and ammonium N. Bacteriological tests for coliform analysis were done according to APHA Standard Methods by the membrane filtration technique. The grab sampling technique was employed for all sampling. Four sample sites were chosen in the Port Dalhousie beach area to determine what bacteriological or physical relationship the sites had to each other. The sample sites chosen were the sewage inflow to and the effluent from the St. Catharines (Port Dalhousie) Pollution Control Plant, Twelve Mile Creek below the sewage outfall and Lake Ontario at the Lakeside Park beach. The sewage outfall was located in Twelve Mile Creek, approximately 80 meters from the creek junction with the beach and piers on Lake Ontario. Twelve Mile Creek normally carried a large volume of water from the WeIland Canal which was diverted through the DeCew Generating Station located on the Niagara Escarpment. An additional sample site, which was thought to be free of industrial wastes, was chosen at Twenty Mile Creek, also in the Niagara Region of Ontarioo 3 There were marked variations in bacterial numbers at each site and between each site, but trends to lower_numbers were noted from the sewage inflow to Lake Ontario. Better correlations were noted between total and faecal coliform population levels and total phosphate P and ammonium N in Twenty Mile Creek. Other correlations were observed for other sample stations, however, these results also appeared to be random in nature. Salmonella isolations occurred more frequently during the winter and spring months when water temperatures were minimal at all sample stations except the sewage inflow. The frequency of Salmonella isolations appeared to be related to increased levels of total and faecal coli forms in the sewage effluent. However, no clear relationships were established in the other sample stations. Due to the presence of Salmonella and high levels of total and faecal coliform indicator organisms, the sanitary quality of Lake Ontario and Twelve Mile Creek at the sample sites seemed to be impaired over the major portion of the study period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les agents anti-infectieux sont utilisés pour traiter ou prévenir les infections chez les humains, les animaux, les insectes et les plantes. L’apparition de traces de ces substances dans les eaux usées, les eaux naturelles et même l’eau potable dans plusieurs pays du monde soulève l’inquiétude de la communauté scientifique surtout à cause de leur activité biologique. Le but de ces travaux de recherche a été d’étudier la présence d’anti-infectieux dans les eaux environnementales contaminées (c.-à-d. eaux usées, eaux naturelles et eau potable) ainsi que de développer de nouvelles méthodes analytiques capables de quantifier et confirmer leur présence dans ces matrices. Une méta-analyse sur l’occurrence des anti-infectieux dans les eaux environnementales contaminées a démontré qu’au moins 68 composés et 10 de leurs produits de transformation ont été quantifiés à ce jour. Les concentrations environnementales varient entre 0.1 ng/L et 1 mg/L, selon le composé, la matrice et la source de contamination. D’après cette étude, les effets nuisibles des anti-infectieux sur le biote aquatique sont possibles et ces substances peuvent aussi avoir un effet indirect sur la santé humaine à cause de sa possible contribution à la dissémination de la résistance aux anti-infecteiux chez les bactéries. Les premiers tests préliminaires de développement d’une méthode de détermination des anti-infectieux dans les eaux usées ont montré les difficultés à surmonter lors de l’extraction sur phase solide (SPE) ainsi que l’importance de la sélectivité du détecteur. On a décrit une nouvelle méthode de quantification des anti-infectieux utilisant la SPE en tandem dans le mode manuel et la chromatographie liquide couplée à la spectrométrie de masse en tandem (LC-MS/MS). Les six anti-infectieux ciblés (sulfaméthoxazole, triméthoprime, ciprofloxacin, levofloxacin, clarithromycin et azithromycin) ont été quantifiés à des concentrations entre 39 et 276 ng/L dans les échantillons d’affluent et d’effluent provenant d’une station d’épuration appliquant un traitement primaire et physico- chimique. Les concentrations retrouvées dans les effluents indiquent que la masse moyenne totale de ces substances, déversées hebdomadairement dans le fleuve St. Laurent, était de ~ 2 kg. En vue de réduire le temps total d’analyse et simplifier les manipulations, on a travaillé sur une nouvelle méthode de SPE couplée-LC-MS/MS. Cette méthode a utilisé une technique de permutation de colonnes pour préconcentrer 1.00 mL d’échantillon dans une colonne de SPE couplée. La performance analytique de la méthode a permis la quantification des six anti-infectieux dans les eaux usées municipales et les limites de détection étaient du même ordre de grandeur (13-60 ng/L) que les méthodes basées sur la SPE manuelle. Ensuite, l’application des colonnes de SPE couplée de chromatographie à débit turbulent pour la préconcentration de six anti-infectieux dans les eaux usées a été explorée pour diminuer les effets de matrice. Les résultats obtenus ont indiqué que ces colonnes sont une solution de réchange intéressante aux colonnes de SPE couplée traditionnelles. Finalement, en vue de permettre l’analyse des anti-infectieux dans les eaux de surface et l’eau potable, une méthode SPE couplée-LC-MS/MS utilisant des injections de grand volume (10 mL) a été développée. Le volume de fuite de plusieurs colonnes de SPE couplée a été estimé et la colonne ayant la meilleure rétention a été choisie. Les limites de détection et de confirmation de la méthode ont été entre 1 à 6 ng/L. L’analyse des échantillons réels a démontré que la concentration des trois anti-infectieux ciblés (sulfaméthoxazole, triméthoprime et clarithromycine) était au dessous de la limite de détection de la méthode. La mesure des masses exactes par spectrométrie de masse à temps d’envol et les spectres des ions produits utilisant une pente d’énergie de collision inverse dans un spectromètre de masse à triple quadripôle ont été explorés comme des méthodes de confirmation possibles.