956 resultados para Conventional water treatment


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Object of the Master’s thesis was to obtain clarification to problems related to sludge treatment at the waste water treatment plant at Stora Enso Varkaus Mill. From time to time these problems have caused emissions to exceed given limits. Case was studied by examining existing data, fiber length fractions and experimental methods. Changes at the Mill have reduced total solids emissions. At the same time the requirement for tertiary treatment has grown. Treatment of tertiary sludge is hard. In the future emission limits shall tighten and the urge for tertiary treatment will grow. The significance of thesis’s results may have a great impact to Stora Enso Varkaus Mill in the future. The results give valuable information to follow-up research and guidelines to sludge treatment. The results encourage observing researched matters at longer period of time. Future recommendations emphasize the meaning of maintenance and systematic, appropriate experiments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The increase in seafood production, especially in mariculture worldwide, has brought out the need of continued monitoring of shellfish production areas in order to ensure safety to human consumption. The purpose of this research was to evaluate pathogenic protozoa, viruses and bacteria contamination in oysters before and after UV depuration procedure, in brackish waters at all stages of cultivation and treatment steps and to enumerate microbiological indicators of fecal contamination from production site up to depuration site in an oyster cooperative located at the Southeastern estuarine area of Brazil. Oysters and brackish water were collected monthly from September 2009 to November 2010. Four sampling sites were selected for enteropathogens analysis: site 1- oyster growth, site 2- catchment water (before UV depuration procedure), site 3 - filtration stage of water treatment (only for protozoa analysis) and site 4- oyster's depuration tank. Three microbiological indicators ! were examined at sites 1, 2 and 4. The following pathogenic microorganisms were searched: Giardia cysts, Cryptosporidium oocysts, Human Adenovirus (HAdV), Hepatitis A virus (HAV), Human Norovirus (HnoV) (genogroups I and II), JC strain Polyomavirus (JCPyV) and Salmonella sp. Analysis consisted of molecular detection (qPCR) for viruses (oysters and water samples); immunomagnetic separation followed by direct immunofluorescence assay for Cryptosporidium oocysts and Giardia cysts and also molecular detection (PCR) for the latter (oysters and water samples); commercial kit (Reveal-Neogee (R)) for Salmonella analysis (oysters). Giardia was the most prevalent pathogen in all sites where it was detected: 36.3%, 18.1%, 36.3% and 27.2% of water from sites 1, 2, 3 and 4 respectively; 36.3% of oysters from site 1 and 54.5% of depurated oysters were harboring Giardia cysts. The huge majority of contaminated samples were classified as Giardia duodenalis. HAdv was detected in water and o! ysters from growth site and HnoV GI in two batches of oysters ! (site 1) in huge concentrations (2.11 x 10(13), 3.10 x 10(12) gc/g). In depuration tank site, Salmonella sp., HAV (4.84 x 10(3)) and HnoV GII (7.97 x 10(14)) were detected once in different batches of oysters. Cryptosporidium spp. oocysts were present in 9.0% of water samples from site four. These results reflect the contamination of oysters even when UV depuration procedures are employed in this shellfish treatment plant. Moreover, the molecular comprehension of the sources of contamination is necessary to develop an efficient management strategy allied to shellfish treatment improvement to prevent foodborne illnesses. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

COD discharges out of processes have increased in line with elevating brightness demands for mechanical pulp and papers. The share of lignin-like substances in COD discharges is on average 75%. In this thesis, a plant dynamic model was created and validated as a means to predict COD loading and discharges out of a mill. The assays were carried out in one paper mill integrate producing mechanical printing papers. The objective in the modeling of plant dynamics was to predict day averages of COD load and discharges out of mills. This means that online data, like 1) the level of large storage towers of pulp and white water 2) pulp dosages, 3) production rates and 4) internal white water flows and discharges were used to create transients into the balances of solids and white water, referred to as “plant dynamics”. A conversion coefficient was verified between TOC and COD. The conversion coefficient was used for predicting the flows from TOC to COD to the waste water treatment plant. The COD load was modeled with similar uncertainty as in reference TOC sampling. The water balance of waste water treatment was validated by the reference concentration of COD. The difference of COD predictions against references was within the same deviation of TOC-predictions. The modeled yield losses and retention values of TOC in pulping and bleaching processes and the modeled fixing of colloidal TOC to solids between the pulping plant and the aeration basin in the waste water treatment plant were similar to references presented in literature. The valid water balances of the waste water treatment plant and the reduction model of lignin-like substances produced a valid prediction of COD discharges out of the mill. A 30% increase in the release of lignin-like substances in the form of production problems was observed in pulping and bleaching processes. The same increase was observed in COD discharges out of waste water treatment. In the prediction of annual COD discharge, it was noticed that the reduction of lignin has a wide deviation from year to year and from one mill to another. This made it difficult to compare the parameters of COD discharges validated in plant dynamic simulation with another mill producing mechanical printing papers. However, a trend of moving from unbleached towards high-brightness TMP in COD discharges was valid.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work studied bottom sediment from catchment area of 13 stations of water treatment of Mogi-Guaçu and Pardo river basins, through identification of mineralogical matrix and its correlation with potential bioavailable metal concentrations. The main clay minerals present were kaolinite and illite. The values of iron and manganese grades were derived from reddish-purple soil, which is rich of such elements. They had higher values on areas with weak vegetation cover compared with other areas linked with more vegetation density. Higher values of calcium at Campestrinho station (IG 69) were associated to occurrence by weathering of calcium feldspars markedly present on regional porphiritic acid rocks. The concentrations of phosphorous are characteristically high on areas near urbanized regions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Low quality mine drainage from tailings facilities persists as one of the most significant global environmental concerns related to sulphide mining. Due to the large variation in geological and environmental conditions at mine sites, universal approaches to the management of mine drainage are not always applicable. Instead, site-specific knowledge of the geochemical behaviour of waste materials is required for the design and closure of the facilities. In this thesis, tailings-derived water contamination and factors causing the pollution were investigated in two coeval active sulphide mine sites in Finland: the Hitura Ni mine and the Luikonlahti Cu-Zn-Co-Ni mine and talc processing plant. A hydrogeochemical study was performed to characterise the tailingsderived water pollution at Hitura. Geochemical changes in the Hitura tailings were evaluated with a detailed mineralogical and geochemical investigation (solid-phase speciation, acid mine drainage potential, pore water chemistry) and using a spatial assessment to identify the mechanisms of water contamination. A similar spatial investigation, applying selective extractions, was carried out in the Luikonlahti tailings area for comparative purposes (Hitura low-sulphide tailings vs. Luikonlahti sulphide-rich tailings). At both sites, hydrogeochemistry of tailings seepage waters was further characterised to examine the net results of the processes observed within the impoundments and to identify constraints for water treatment. At Luikonlahti, annual and seasonal variation in effluent quality was evaluated based on a four-year monitoring period. Observations pertinent to future assessment and mine drainage prevention from existing and future tailings facilities were presented based on the results. A combination of hydrogeochemical approaches provided a means to delineate the tailings-derived neutral mine drainage at Hitura. Tailings effluents with elevated Ni, SO4 2- and Fe content had dispersed to the surrounding aquifer through a levelled-out esker and underneath the seepage collection ditches. In future mines, this could be avoided with additional basal liners in tailings impoundments where the permeability of the underlying Quaternary deposits is inadequate, and with sufficiently deep ditches. Based on the studies, extensive sulphide oxidation with subsequent metal release may already initiate during active tailings disposal. The intensity and onset of oxidation depended on e.g. the Fe sulphide content of the tailings, water saturation level, and time of exposure of fresh sulphide grains. Continuous disposal decreased sulphide weathering in the surface of low-sulphide tailings, but oxidation initiated if they were left uncovered after disposal ceased. In the sulphide-rich tailings, delayed burial of the unsaturated tailings had resulted in thick oxidized layers, despite the continuous operation. Sulphide weathering and contaminant release occurred also in the border zones. Based on the results, the prevention of sulphide oxidation should already be considered in the planning of tailings disposal, taking into account the border zones. Moreover, even lowsulphide tailings should be covered without delay after active disposal ceases. The quality of tailings effluents showed wide variation within a single impoundment and between the two different types of tailings facilities assessed. The affecting factors included source materials, the intensity of weathering of tailings and embankment materials along the seepage flow path, inputs from the process waters, the water retention time in tailings, and climatic seasonality. In addition, modifications to the tailings impoundment may markedly change the effluent quality. The wide variation in the tailings effluent quality poses challenges for treatment design. The final decision on water management requires quantification of the spatial and seasonal fluctuation at the site, taking into account changes resulting from the eventual closure of the impoundment. Overall, comprehensive hydrogeochemical mapping was deemed essential in the identification of critical contaminants and their sources at mine sites. Mineralogical analysis, selective extractions, and pore water analysis were a good combination of methods for studying the weathering of tailings and in evaluating metal mobility from the facilities. Selective extractions with visual observations and pH measurements of tailings solids were, nevertheless, adequate in describing the spatial distribution of sulphide oxidation in tailings impoundments. Seepage water chemistry provided additional data on geochemical processes in tailings and was necessary for defining constraints for water treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Centrifugal compressors are widely used for example in refrigeration processes, the oil and gas industry, superchargers, and waste water treatment. In this work, five different vaneless diffusers and six different vaned diffusers are investigated numerically. The vaneless diffusers vary only by their diffuser width, so that four of the geometries have pinch implemented to them. Pinch means a decrease in the diffuser width. Four of the vaned diffusers have the same vane turning angle and a different number of vanes, and two have different vane turning angles. The flow solver used to solve the flow fields is Finflo, which is a Navier-Stokes solver. All the cases are modeled with the Chien's k – έ- turbulence model, and selected cases are modeled also with the k – ώ-SST turbulence model. All five vaneless diffusers and three vaned diffusers are investigated also experimentally. For each construction, the compressor operating map is measured according to relevant standards. In addition to this, the flow fields before and after the diffuser are measured with static and total pressure, flow angle and total temperature measurements. When comparing the computational results to the measured results, it is evident that the k – ώ-SST turbulence model predicts the flow fields better. The simulation results indicate that it is possible to improve the efficiency with the pinch, and according to the numerical results, the two best geometries are the ones with most pinch at the shroud. These geometries have approximately 4 percentage points higher efficiency than the unpinched vaneless diffusers. The hub pinch does not seem to have any major benefits. In general, the pinches make the flow fields before and after the diffuser more uniform. The pinch also seems to improve the impeller efficiency. This is down to two reasons. The major reason is that the pinch decreases the size of slow flow and possible backflow region located near the shroud after the impeller. Secondly, the pinches decrease the flow velocity in the tip clearance, leading to a smaller tip leakage flow and therefore slightly better impeller efficiency. Also some of the vaned diffusers improve the efficiency, the increment being 1...3 percentage points, when compared to the vaneless unpinched geometry. The measurement results confirm that the pinch is beneficial to the performance of the compressor. The flow fields are more uniform with the pinched cases, and the slow flow regions are smaller. The peak efficiency is approximately 2 percentage points and the design point efficiency approximately 4 percentage points higher with the pinched geometries than with the un- pinched geometry. According to the measurements, the two best geometries are the ones with the most pinch at the shroud, the case with the pinch only at the shroud being slightly better of the two. The vaned diffusers also have better efficiency than the vaneless unpinched geometries. However, the pinched cases have even better efficiencies. The vaned diffusers narrow the operating range considerably, whilst the pinch has no significant effect on the operating range.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The growing concern of environmental surveillance of the quality of hydric resources guides the development of research on management of residues generated in water treatment plants (WTP). Approximately 8.000 WTPs in Brazil operate without a treatment program of the residues, disposing these effluents in the environment. This work evaluated WTP discharges into watercourses by collecting superficial waters, sediments and benthic samples at the town of Registro, São Paulo State, Brazil. Even though superficial waters and benthic samples showed no further contamination, sediment analysis pointed out that aluminum deposits detected near sludge discharges may represent a potential risk to the environment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El tractament de les aigües en nuclis menors de 2000 habitants es troba pendent de completar per part de l’Agència Catalana de l’Aigua més concretament al corresponent Pla de Sanejament d’Aigües Residuals Urbanes (PSARU). El nucli de La Nou de Gaià (al Tarragonès) es troba pendent de la construcció de la corresponent instal·lació de sanejament, projectada al 2007. Alternativament a les depuradores tradicionals basades en l’ús de formigó (o materials alternatius) i en la despesa elèctrica per assegurar una aeració i una evacuació dels fangs generats, existeixen tecnologies “toves”. Aquestes tecnologies, també conegudes com a “verdes”, es basen en imitar els sistemes naturals maximitzant el seu potencial d’autodepuració. A grans trets existeixen dos formes de depurar les aigües de forma ecològica”: llacunatges (existeix una capa d’aigua lliure) i filtres verds. El present estudi es basa en l’aplicació de filtres verds de morfologia vertical i flux subsuperficial, plantat amb canyes dels generes Scirpus o Phragmites. El resultat han estat 4 bases de 35*35 per a tractar un cabal de 150 m3/d i una població equivalent de 1272.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the present paper, the use of poly(styrene sulfonate) (PSS), produced from discarded polystyrene materials through heterogeneous and homogeneous processes, was investigated. The use of PSS for water treatment, using a kaolin suspension as wastewater model, reduced water turbidity for all the employed materials when compared to the blank analysis, without PSS. The most efficient polyelectrolyte was PSS cups obtained by homogeneous route. The same behavior was observed for real system. The homogeneous PSS cups showed a balance between a moderate molecular weight and high anionic character that improved flocks formation and water removal turbidity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This survey determined the physical and chemical properties of the gravel place where urban sludge from Rio Descoberto's Water Treatment Plant is disposed. Physical, chemical and biological analysis of the soil samples (n=54), sludge samples (n=2), chemical coagulant (n=20) and samples from superficial waters (n=9) and water table (n=60) were performed. As results we can emphasize the horizontal distribution of mineral phases like gibbsite, organic material, exchanged Ca, available Mn and P on the soils are originated from the sludge. Some of these mobile elements could stimulate the growing of the vegetation, but they also could contaminate the water table.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, the efficiency of clarification treatment (coagulation, flocculation and sedimentation) with polyaluminum chloride (PAC) and aluminum sulfate (SA) as coagulants was evaluated in the removal of 7 microcontaminants (diclofenac - DCF, sulfamethoxazole - SMX, ethinylestradiol - EE2, bisphenol-A - BPA, estradiol - E2, estrone - E1 and estriol - E3) in water of low and high turbidity. The clarification treatment led to poor removal rates (40% at most) for all microcontaminants except SMX which exhibited intermediate removal efficiency (67 to 70%). Overall, PAC application yielded better performance compared to SA.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The dissertation is based on four articles dealing with recalcitrant lignin water purification. Lignin, a complicated substance and recalcitrant to most treatment technologies, inhibits seriously pulp and paper industry waste management. Therefore, lignin is studied, using WO as a process method for its degradation. A special attention is paid to the improvement in biodegradability and the reduction of lignin content, since they have special importance for any following biological treatment. In most cases wet oxidation is not used as a complete ' mineralization method but as a pre treatment in order to eliminate toxic components and to reduce the high level of organics produced. The combination of wet oxidation with a biological treatment can be a good option due to its effectiveness and its relatively low technology cost. The literature part gives an overview of Advanced Oxidation Processes (AOPs). A hot oxidation process, wet oxidation (WO), is investigated in detail and is the AOP process used in the research. The background and main principles of wet oxidation, its industrial applications, the combination of wet oxidation with other water treatment technologies, principal reactions in WO, and key aspects of modelling and reaction kinetics are presented. There is also given a wood composition and lignin characterization (chemical composition, structure and origin), lignin containing waters, lignin degradation and reuse possibilities, and purification practices for lignin containing waters. The aim of the research was to investigate the effect of the operating conditions of WO, such as temperature, partial pressure of oxygen, pH and initial concentration of wastewater, on the efficiency, and to enhance the process and estimate optimal conditions for WO of recalcitrant lignin waters. Two different waters are studied (a lignin water model solution and debarking water from paper industry) to give as appropriate conditions as possible. Due to the great importance of re using and minimizing the residues of industries, further research is carried out using residual ash of an Estonian power plant as a catalyst in wet oxidation of lignin-containing water. Developing a kinetic model that includes in the prediction such parameters as TOC gives the opportunity to estimate the amount of emerging inorganic substances (degradation rate of waste) and not only the decrease of COD and BOD. The degradation target compound, lignin is included into the model through its COD value (CODligning). Such a kinetic model can be valuable in developing WO treatment processes for lignin containing waters, or other wastewaters containing one or more target compounds. In the first article, wet oxidation of "pure" lignin water was investigated as a model case with the aim of degrading lignin and enhancing water biodegradability. The experiments were performed at various temperatures (110 -190°C), partial oxygen pressures (0.5 -1.5 MPa) and pH (5, 9 and 12). The experiments showed that increasing the temperature notably improved the processes efficiency. 75% lignin reduction was detected at the lowest temperature tested and lignin removal improved to 100% at 190°C. The effect of temperature on the COD removal rate was lower, but clearly detectable. 53% of organics were oxidized at 190°C. The effect of pH occurred mostly on lignin removal. Increasing the pH enhanced the lignin removal efficiency from 60% to nearly 100%. A good biodegradability ratio (over 0.5) was generally achieved. The aim of the second article was to develop a mathematical model for "pure" lignin wet oxidation using lumped characteristics of water (COD, BOD, TOC) and lignin concentration. The model agreed well with the experimental data (R2 = 0.93 at pH 5 and 12) and concentration changes during wet oxidation followed adequately the experimental results. The model also showed correctly the trend of biodegradability (BOD/COD) changes. In the third article, the purpose of the research was to estimate optimal conditions for wet oxidation (WO) of debarking water from the paper industry. The WO experiments were' performed at various temperatures, partial oxygen pressures and pH. The experiments showed that lignin degradation and organics removal are affected remarkably by temperature and pH. 78-97% lignin reduction was detected at different WO conditions. Initial pH 12 caused faster removal of tannins/lignin content; but initial pH 5 was more effective for removal of total organics, represented by COD and TOC. Most of the decrease in organic substances concentrations occurred in the first 60 minutes. The aim of the fourth article was to compare the behaviour of two reaction kinetic models, based on experiments of wet oxidation of industrial debarking water under different conditions. The simpler model took into account only the changes in COD, BOD and TOC; the advanced model was similar to the model used in the second article. Comparing the results of the models, the second model was found to be more suitable for describing the kinetics of wet oxidation of debarking water. The significance of the reactions involved was compared on the basis of the model: for instance, lignin degraded first to other chemically oxidizable compounds rather than directly to biodegradable products. Catalytic wet oxidation of lignin containing waters is briefly presented at the end of the dissertation. Two completely different catalysts were used: a commercial Pt catalyst and waste power plant ash. CWO showed good performance using 1 g/L of residual ash gave lignin removal of 86% and COD removal of 39% at 150°C (a lower temperature and pressure than with WO). It was noted that the ash catalyst caused a remarkable removal rate for lignin degradation already during the pre heating for `zero' time, 58% of lignin was degraded. In general, wet oxidation is not recommended for use as a complete mineralization method, but as a pre treatment phase to eliminate toxic or difficultly biodegradable components and to reduce the high level of organics. Biological treatment is an appropriate post treatment method since easily biodegradable organic matter remains after the WO process. The combination of wet oxidation with subsequent biological treatment can be an effective option for the treatment of lignin containing waters.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diplomityö on osa Mikkelin ammattikorkeakoulun YTI:ssä vuosina 2005 - 2008 toteutettua ”Yritysten ympäristöriskit” EU-osarahoitteista hanketta. Työn tarkoituksena oli tunnistaa, arvioida ja luokittaa Etelä-Savossa, Juvalla toimivan yhdyskuntajätevedenpuhdistamon ympäristöriskit sekä antaa neuvoja löytyneiden riskien hallintaan. Jätevedenpuhdistamon toiminnasta syntyvät mahdolliset ympäristöriskitekijät tunnistettiin kirjallisuusselvitysten sekä haastattelujen avulla. Riskien tunnistamisen jälkeen riskien kartoittamiseen, arviointiin ja luokittamiseen käytettiin osia eri riskianalyysimenetelmistä. Riskit jaettiin viiteen eri riskiluokkaan; vakavasta riskistä merkityksettömään riskiin. Juvan kunnan jätevedenpuhdistamolla esiintyi neljän pienimmän riskiluokan riskejä, ja vakavia riskejä ei kartoituksessa tullut esille lainkaan. Riskejä arvioitiin niin sanotuissa normaalioloissa. Merkittävin yksittäinen riskitekijä jätevedenpuhdistamolla oli haitallisen tai poikkeavan aineen kulkeutuminen jäteveden mukana puhdistamolle. Tämä voisi heikentää puhdistamon puhdistustulosta merkittävästi. Kun laitosta ajetaan ympäristöluvassa asetettujen vaatimusten mukaisesti ja alueella sijaitsevat teollisuuslaitokset noudattavat heille annettuja määräyksiä, ei Juvan jätevedenpuhdistamolta aiheudu merkittäviä päästöjä maa-perään tai pohjavesiin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli tutkia biokaasulaitoksen rejektivesien ominaisuuksiin vaikuttavia tekijöitä ja rejektiveden esikäsittelyn tarpeellisuutta. Lisäksi tavoitteena oli tarkastella Kouvolaan suunnitteilla olevan Kymen Bioenergia Oy:n biokaasulaitoksen rejektivesien vaikutusta Kouvolan Veden Mäkikylän jätevedenpuhdistamolla. Biokaasulaitoksen rejektivedet ovat yhdyskuntajätevesiin verrattuna selvästi konsentroituneempia. Jätevedenpuhdistamoilla erityisesti rejektiveden korkea typpipitoisuus aiheuttaa lisäkuormitusta. Suomessa toiminnassa oleville biokaasulaitoksille tehdyn kyselytutkimuksen tulosten perusteella rejektiveden typpipitoisuuteen vaikuttaa syötteen typpipitoisuus sekä mädätysjäännöksen kuivauksen tehokkuus. Rejektiveden kiintoainepitoisuudella on puolestaan vaikutusta biologiseen hapenkulutukseen ja välillisesti myös rejektiveden kemialliseen hapenkulutukseen. Rejektivesien jätevedenpuhdistamoilla aiheuttamaa kuormitusta on mahdollista vähentää esikäsittelemällä rejektivedet joko biologisella tai fysikaalis-kemiallisella puhdistusmenetelmällä. Kyselytutkimus kuitenkin osoitti, että rejektivesien esikäsittelyssä ei aina päästä puhdistustavoitteeseen. Jätevedenkäsittelyn sijaan rejektivesiä on mahdollista käyttää lannoitteena, mikäli biokaasulaitoksen syöte ei sisällä jätevedenpuhdistamon lietteitä. Myös Kouvolan Veden Mäkikylän puhdistamolla biokaasulaitoksen rejektivedet tulevat lisäämään merkittävästi tulovirtaaman typpikuormaa. Typpikuorman lisäys edellyttää ilmastusaltaassa ilmastuksen tehostamista sekä kalkin syöttömäärän lisäämistä, jotta jäteveden happipitoisuus ja pH pysyvät typenpoistoreaktioille suotuisina. Lisäksi tulovirtaamasta puolet tullaan ohjaamaan esiselkeyttimen ohi, jotta ilmastusaltaassa on orgaanista ainetta typenpoistoon riittävästi. Mäkikylän puhdistamon typenpoistokapasiteettia on mahdollista kasvattaa lisähiilen syötöllä. Mikäli biokaasulaitoksen kapasiteettilisäyksen jälkeen rejektivesien typpikuoma ylittää lisähiilellä saavutetun lisäkapasiteetin, on rejektivedet esikäsiteltävä.