759 resultados para Apertureless aplanatic lens
Resumo:
Purpose: The primary outcome of this study is to compare the axial length growth of white European myopic children wearing orthokeratology contact lenses (OK) to a control group (CT) over a 7-year period. Methods: Subjects 6–12 years of age with myopia −0.75 to −4.00DS and astigmatism ≤1.00DC were prospectively allocated OK or distance single-vision spectacles (SV) correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals over a 2-year period. Subjects were invited to return to the clinic approximately 5 years later (i.e., 7 years after the beginning of the study) for assessment of their ocular refractive and biometric components. The CT consisted of 4 SV and 12 subjects who switched from SV to soft contact lens wear after the initial 2 years of SV lens wear. Changes in axial length relative to baseline over a 7-year period were compared between groups. Results: Fourteen and 16 subjects from the OK and CT groups, respectively, were examined 6.7 ± 0.5 years after the beginning of the study. Statistically significant changes in the axial length were found over time and between groups (both p <0.001), but not for the time*group interaction (p = 0.125). The change in the axial length for the OK group was 22% (p = 0.328), 42% (p = 0.007), 40% (p = 0.020), 41% (p = 0.013), and 33% (p = 0.062) lower than the CT group following 6, 12, 18, 24, and 84 months of lens wear, respectively. Conclusion: A trend toward a reduction in the rate of axial elongation of the order of 33% was found in the OK group in comparison to the CT group following 7 years of lens wear.
Resumo:
Background In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Methods Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Results Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Conclusions Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Trial registration Eudract Clinical Trials Registry Number: 2014-003266-2.
Resumo:
A main prediction from the zoom lens model for visual attention is that performance is an inverse function of the size of the attended area. The "attention shift paradigm" developed by Sperling and Reeves (1980) was adapted here to study predictions from the zoom lens model. In two experiments two lists of items were simultaneously presented using the rapid serial visual presentation technique. Subjects were to report the first item he/she was able to identify in the series that did not include the target (the letter T) after he/she saw the target. In one condition, subjects knew in which list the target would appear, in another condition, they did not have this knowledge, having to attend to both positions in order to detect the target. The zoom lens model predicts an interaction between this variable and the distance separating the two positions where the lists are presented. In both experiments, this interaction was observed. The results are also discussed as a solution to the apparently contradictory results with regard to the analog movement model.
Resumo:
Abstract : Information and communication technologies (ICTs, henceforth) have become ubiquitous in our society. The plethora of devices competing with the computer, from iPads to the Interactive whiteboard, just to name a few, has provided teachers and students alike with the ability to communicate and access information with unprecedented accessibility and speed. It is only logical that schools reflect these changes given that their purpose is to prepare students for the future. Surprisingly enough, research indicates that ICT integration into teaching activities is still marginal. Many elementary and secondary schoolteachers are not making effective use of ICTs in their teaching activities as well as in their assessment practices. The purpose of the current study is a) to describe Quebec ESL teachers’ profiles of using ICTs in their daily teaching activities; b) to describe teachers’ ICT integration and assessment practices; and c) to describe teachers’ social representations regarding the utility and relevance of ICT use in their daily teaching activities and assessment practices. In order to attain our objectives, we based our theoretical framework, principally, on the social representations (SR, henceforth) theory and we defined most related constructs which were deemed fundamental to the current thesis. We also collected data from 28 ESL elementary and secondary school teachers working in public and private sectors. The interview guide used to that end included a range of items to elicit teachers’ SR in terms of ICT daily use in teaching activities as well as in assessment practices. In addition, we carried out our data analyses from a textual statistics perspective, a particular mode of content analysis, in order to extract the indicators underlying teachers’ representations of the teachers. The findings suggest that although almost all participants use a wide range of ICT tools in their practices, ICT implementation is seemingly not exploited to its fullest potential and, correspondingly, is likely to produce limited effects on students’ learning. Moreover, none of the interviewees claim that they use ICTs in their assessment practices and they still hold to the traditional paper-based assessment (PBA, henceforth) approach of assessing students’ learning. Teachers’ common discourse reveals a gap between the positive standpoint with regards to ICT integration, on the one hand, and the actual uses of instructional technology, on the other. These results are useful for better understanding the way ESL teachers in Quebec currently view their use of ICTs, particularly for evaluation purposes. In fact, they provide a starting place for reconsidering the implementation of ICTs in elementary and secondary schools. They may also be useful to open up avenues for the development of a future research program in this regard.
Resumo:
In the upcoming years, various upgrades and improvements are planned for the CERN Large Hadron Collider (LHC) and represent the mandate of the High-Luminosity project. The upgrade will allow for a total stored beam energy of about 700 MJ, which will need, among others, an extremely efficient collimation system. This will be achieved with the addition of a hollow electron lens (HEL) system to help control the beam-halo depletion and mitigate the effects of fast beam losses. In this master thesis, we present a diffusion model of the HEL for HL-LHC. In particular, we explore several scenarios to use such a device, focusing on the halo depletion efficiency given by different noise regimes.
Resumo:
A case of identical male twins with Cohen syndrome who present multiple ophthalmic findings is reported. The patients were identical 16 year-old twin boys who showed down slanting eyelids, mild ptosis, high-grade myopia, small cortical lens opacities, posterior subcapsular cataracts, myotic and corectopic pupils with poor dilation due to focal iris atrophy and retinochoroidal dystrophy. Ophthalmologists must be aware of the ocular and systemic findings of Cohen syndrome in the evaluation of young patients with mental retardation and visual impairment.
Resumo:
This paper describes a topiramate induced acute bilateral angle-closure glaucoma. This rare adverse effect is an idiosyncratic reaction characterized by uveal effusion and lens forward displacement, leading to increased intraocular pressure and vision loss. We describe a 55 year-old white woman with migraine, spasmodic torticollis and essential tremor, who developed bilateral acute angle-closure glaucoma, one week after starting topiramate 25 mg/day. She was seen at the Ophthalmology Emergency Department of the Fundação João Penido Burnier (Campinas, SP, Brazil) with a 4 hours history of blurry vision, ocular pain and bright flashes vision. Slit lamp examination revealed moderate conjunctival injection and corneal edema, and shallow anterior chambers. Intraocular pressure was 48 mmHg in both eyes. Fundoscopic examination findings were normal. She was treated with timolol, brimonidine, dorzolamide, pilocarpine, prednisone acetate eye drops and acetazolamide. One hour after those measures, as the intraocular pressure was 30 mmHg, she received a manitol intravenous injection and the intraocular pressure normalized. After 24 hours an iridotomy with Yag laser was performed. Topiramate was discontinued and she was totally recovered after one week.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
OBJETIVO: Desenvolver simulação computadorizada de ablação para produzir lentes de contato personalizadas a fim de corrigir aberrações de alta ordem. MÉTODOS: Usando dados reais de um paciente com ceratocone, mensurados em um aberrômetro ("wavefront") com sensor Hartmann-Shack, foram determinados as espessuras de lentes de contato que compensam essas aberrações assim como os números de pulsos necessários para fazer ablação as lentes especificamente para este paciente. RESULTADOS: Os mapas de correção são apresentados e os números dos pulsos foram calculados, usando feixes com a largura de 0,5 mm e profundidade de ablação de 0,3 µm. CONCLUSÕES: Os resultados simulados foram promissores, mas ainda precisam ser aprimorados para que o sistema de ablação "real" possa alcançar a precisão desejada.
Resumo:
OBJETIVO: Desenvolver a instrumentação e o "software" para topografia de córnea de grande-ângulo usando o tradicional disco de Plácido. O objetivo é permitir o mapeamento de uma região maior da córnea para topógrafos de córnea que usem a técnica de Plácido, fazendo-se uma adaptação simples na mira. MÉTODOS: Utilizando o tradicional disco de Plácido de um topógrafo de córnea tradicional, 9 LEDs (Light Emitting Diodes) foram adaptados no anteparo cônico para que o paciente voluntário pudesse fixar o olhar em diferentes direções. Para cada direção imagens de Plácido foram digitalizadas e processadas para formar, por meio de algoritmo envolvendo elementos sofisticados de computação gráfica, um mapa tridimensional completo da córnea toda. RESULTADOS: Resultados apresentados neste trabalho mostram que uma região de até 100% maior pode ser mapeada usando esta técnica, permitindo que o clínico mapeie até próximo ao limbo da córnea. São apresentados aqui os resultados para uma superfície esférica de calibração e também para uma córnea in vivo com alto grau de astigmatismo, mostrando a curvatura e elevação. CONCLUSÃO: Acredita-se que esta nova técnica pode propiciar a melhoria de alguns processos, como por exemplo: adaptação de lentes de contato, algoritmos para ablações costumizadas para hipermetropia, entre outros.
Resumo:
A literatura francesa e mundial passaram por uma enorme transformação ao longo do século XIX. A primorosa escrita de Flaubert é, para além de sua importância estética, reveladora de um novo modo de se escrever, ler e representar o homem no mundo moderno. O cuidado na construção do texto, a utilização de imagens plásticas e figuras de linguagem, ao mesmo tempo em que o narrador torna-se invisível no emprego do discurso indireto livre são característicos da escrita flaubertiana. O autor apresenta-nos em "Um coração simples" um "retrato" de Félicité, mulher pobre do interior da França, modelo virtuoso de uma ética evanescente. Ao acompanhar, por meio do conto, os passos e desventuras de Felicité, sob as lentes deste novo narrador, buscamos evidenciar as condições que circundam o aparecimento de um olhar científico-objetivo para a subjetividade humana, logo transformada em objeto de uma nascente Psicologia.
Resumo:
BACKGROUND: Age-related cataracts (ARCs) are an important cause of blindness in developing countries. Although antioxidants may be part of the body's defense to prevent ARC, environmental contaminants may contribute to cataractogenesis. In fish-eating populations of the lower Tapajos region, elevated exposure to mercury (Hg) has been reported, and blood levels of selenium (Se) range from normal to very high (> 1,000 mu g/L). OBJECTIVES: We examined ARCs in relation to these elements among adults (>= 40 years of age) from 12 riverside communities. METHODS: Participants (n = 211) provided blood samples and underwent an extensive ocular examination. Inductively coupled plasma mass spectrometry was used to assess Hg and Se in blood and plasma. RESULTS: One-third (n = 69; 32.7%) of the participants had ARC. Lower plasma Se (P-Se; < 25th percentile, 110 mu g/L) and higher blood Hg (B-Hg; >= 25th percentile, 25 mu g/L) were associated with a higher prevalence odds ratio (POR) of ARC [adjusted POR (95% confidence interval), 2.69 (1.11-6.56) and 4.45 (1.43-13.83), respectively]. Among participants with high P-Se, we observed a positive but nonsignificant association with high B-Hg exposure, whereas among those with low B-Hg, we observed no association for P-Se. However, compared with the optimum situation (high P-Se, low B-Hg), the POR for those with low P-Se and high B-Hg was 16.4 (3.0-87.9). This finding suggests a synergistic effect. CONCLUSION: Our results suggest that persons in this population with elevated Hg, the cataractogenic effects of Hg may be offset by Se. Because of the relatively small sample size and possible confounding by other dietary nutrients, additional studies with sufficient power to assess multiple nutrient and toxic interactions are required to confirm these findings.
Resumo:
We report the discovery of seven new, very bright gravitational lens systems from our ongoing gravitational lens search, the Sloan Bright Arcs Survey (SBAS). Two of the systems are confirmed to have high source redshifts z = 2.19 and z = 2.94. Three other systems lie at intermediate redshift with z = 1.33, 1.82, 1.93 and two systems are at low redshift z = 0.66, 0.86. The lensed source galaxies in all of these systems are bright, with i-band magnitudes ranging from 19.73 to 22.06. We present the spectrum of each of the source galaxies in these systems along with estimates of the Einstein radius for each system. The foreground lens in most systems is identified by a red sequence based cluster finder as a galaxy group; one system is identified as a moderately rich cluster. In total, SBAS has now discovered 19 strong lens systems in the SDSS imaging data, 8 of which are among the highest surface brightness z similar or equal to 2-3 galaxies known.