969 resultados para Antennas Array
Resumo:
国家863计划
Resumo:
Bloch modes can be excited in planar array due to its periodic lateral refractive index. The power coupled into each eigenmode of the array waveguides is calculated through the overlap integrals of the input field with the eigenmode fields of the coupled infinite array waveguides projected onto the x-axis. Low losses can be obtained if the transition from the array to the free propagation region is adiabatic. Due to the finite resolution of lithographic process the gap between the waveguides will stop abruptly, however, when the waveguides come into too close together. Calculation results show that losses will occur at this discontinuity, which are dependent on the ratio of the gap between the waveguides and grating pitch and on the confinement of field in the array waveguides. Tapered waveguides and low index contrast between the core and cladding layers can lower the transmitted losses.
Resumo:
Large area (25 mm(2)) silicon drift detectors and detector arrays (5x5) have been designed, simulated, and fabricated for X-ray spectroscopy. On the anode side, the hexagonal drift detector was designed with self-biasing spiral cathode rings (p(+)) of fixed resistance between rings and with a grounded guard anode to separate surface current from the anode current. Two designs have been used for the P-side: symmetric self-biasing spiral cathode rings (p(+)) and a uniform backside p(+) implant. Only 3 to 5 electrodes are needed to bias the detector plus an anode for signal collection. With graded electrical potential, a sub-nanoamper anode current, and a very small anode capacitance, an initial FWHM of 1.3 keV, without optimization of all parameters, has been obtained for 5.9 keV Fe-55 X-ray at RT using a uniform backside detector.
Resumo:
The research of the in-beam efficiency calibration of Neutron Detector Array of Peking University using N-17 and C-16 beams was introduced in this paper. The efficiency of neutron wall and ball are comparable to the foreign similar devices and neutrons can be detected from low to high energies in high efficiency.
Resumo:
探测器位置分辨能力的高低是实现γ成像的一个重要指标.Segmented HPGe平面型位置灵敏探测器能够很好地给出γ射线与探测器晶体相互作用的作用点位置信息.利用由这种探测器组成的探测器阵列对~(22)Na标准源进行了γ成像实验.结果能够区分出标准源两个不同的摆放位置的细微差别,并与实际情况符合得很好.从而检验了Segmented HPGe平面型位置灵敏探测器的位置分辨能力.
Resumo:
描述了1个8×8单元CsI(Tl)探测阵列的结构和工作原理。探测阵列的每个单元是由1块前表面21 mm×21 mm、后表面23.1 mm×23.1 mm、高50 mm的CsI(Tl)棱台、1块光导和光电倍增管组成。在兰州放射性次级束流线(RIBLL)上对探测阵列进行测试,得到探测阵列对30 MeV质子的能量分辨可达2.7%,对170 MeV7Be可达1.5%,可很好地用于放射性束物理实验中带电粒子的鉴别。
Resumo:
The isoflavonoids in Radix astragali were determined and identified by HPLC-photodiode array detection-MS after extraction employing matrix solid-phase dispersion (MSPD). As a new sample preparation method for R. astragali, the MSPD procedure was optimized, validated and compared with conventional methods including ultrasonic and Soxhlet extraction. The amounts of two major components in this herb, formononetin (6) and ononin (2), were determined based on their authentic standards. Four major isoflavonoids, formononetin (6), ononin (2), calycosin (5) and its glycoside (1), and three minor isoflavonoids, (6aR,11aR)-3-hydroxy-9, 10-dimethoxypterocarpan (7), its glycoside (3), and (3R)-7,2'-dihydroxy-3',4'-dimethoxyisoflavone-7-O-beta-D-glycoside (4), were identified based on their characteristic two-band UV spectra and [M + H](+), [aglycone + H](+) and [A1 + H](+) ions, etc. The combined MSPD and HPLC-DAD-MS method was suitable for quantitative and qualitative determination of the isoflavonoids in R. astragali. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
A capillary array electrophoresis system with rotary corifocal fluorescence scanner was reported. High speed direct current rotary motor combined with a rotary encoder and the reflection mirror has been designed to direct exactly the excitation laser beam. to the array of capillaries, which are symmetrically distributed around the motor. The rotary encoder is introduced to accurately orient the position of each capillary and its output signal triggers the data acquiring system to record. the fluorescence signal corresponding to each capillary. Separations of several amino acids are demonstrated by eight-channel capillary array electrophoresis built by ourselves.
Resumo:
A 2-kW-class chemical oxygen-iodine laser (COIL) using nitrogen buffer gas has been developed and tested since industrial applications of COIL devices will require the use of nitrogen as the buffer gas. The laser, with a gain length of 11.7 cm, is energized by a square pipe-array jet-type singlet oxygen generator (SPJSOG) and employs a nozzle bank with a designed Mach number of 2.5. The SPJSOG has advantages over the traditional plate-type JSOG in that it has less requirements on basic hydrogen peroxide (BHP) pump, and more important, it has much better operational stability. The SPJSOG without a cold trap and a gas-liquid separator could provide reliable operations for a total gas flow rate up to 450 mmol/s and with a low liquid driving pressure of around 0.7 atm or even lower. The nozzle bank was specially designed for a COIL using nitrogen as the buffer gas. The cavity was designed for a Mach number of 2.5, in order to provide a gas speed and static temperature in the cavity similar to that for a traditional COIL with helium buffer gas and a Mach 2 nozzle. An output power of 2.6 kW was obtained for a chlorine flow rate of 140 mmol/s, corresponding to a chemical efficiency of 20.4%. When the chlorine flow rate was reduced to 115 mmol/s, a higher chemical efficiency of 22.7% was attained. Measurements showed that the SPJSOG during normal operation could provide a singlet oxygen yield Y greater than or equal to 55%, a chlorine utilization U greater than or equal to 85%, and a relative water vapor concentration w = [H2O]/([O-2] + [Cl-2]) less than or equal to 0.1.
Resumo:
Herein, we report a simple and inexpensive way for fabrication of ultra microelectrode arrays (UMEAs) and the relative characterization methods. The fabrication of UMEAs involves only a few steps of handwork. Since only metal wires and epoxy are used through the fabrication process, it is supposed to be a quite straightforward method for preparing UMEAs. A dissolved oxygen (DO) sensor based on UMEAs was constructed.
Resumo:
We first suggested a one-pot method to synthesize monodisperse raspberry-like submicrometer gold spheres (MRSGS) with high yield. The resulting gold spheres were characterized by scanning electron microscopy, transmission electron microscopy, energy-dispersed X-ray spectroscopy, X-ray photoelectron spectroscopy, X-ray diffraction, and electrochemical technology. It was found that the rough structure provided by raspberry-like gold spheres led to a tremendous electrochemical active area, which was very important because these novel hierarchical gold spheres will probably find important applications in biosensors, electrocatalysis, and others.
Resumo:
A two-armed polymer with a crown ether core self-assembles to produce macroporous films with pores perpendicularly reaching through the film down to the substrate. A possible assembling mechanism is discussed. The pore size can be conveniently adjusted by changing the solution concentration. These through-hole macroporous films provide a template for fabricating an array of Cu nanoparticle aggregates.