991 resultados para Analytical Spectral Devices (ASD), FieldSpec Pro
Resumo:
We introduce biomimetic in silico devices, and means for validation along with methods for testing and refining them. The devices are constructed from adaptable software components designed to map logically to biological components at multiple levels of resolution. In this report we focus on the liver; the goal is to validate components that mimic features of the lobule (the hepatic primary functional unit) and dynamic aspects of liver behavior, structure, and function. An assembly of lobule-mimetic devices represents an in silico liver. We validate against outflow profiles for sucrose administered as a bolus to isolated, perfused rat livers. Acceptable in silico profiles are experimentally indistinguishable from those of the in situ referent. This new technology is intended to provide powerful Dew tools for challenging our understanding of how biological functional units function in vivo.
Resumo:
An experimental investigation of mechanical properties of thin films using nanoindentation was reported. Silicon nitride thin films with different thicknesses were deposited using plasma enhanced chemical vapor deposition (PECVD) on Si substrate. Nanoindentation was used to measure their elastic modulus and hardness. The results indicated that for a film/substrate bilayer system, the measured mechanical properties are significantly affected by the substrate properties. Empirical formulas were proposed for deconvoluting the film properties from the measured bilayer properties.
Resumo:
Magnetic field effects on the conductivity of different types of organic devices: undoped and dye doped aluminium (III) 8-hydroxyquinoline (Alq(3))-based organic light emitting diodes (OLEDs), electron-only Alq(3)-based diodes, and a hole-only N,N`-diphenyl-N,N`-bis(1-naphthyl)1,1`-biphenyl-4,4`-diamine (alpha-NPD)-based diode were studied at room temperature. Only negative magnetoresistance (MR) was observed for the Alq(3)-based devices. The addition of a rubrene dye in Alq(3)-based OLEDs quenches the MR by a factor of 5. The alpha-NPD hole-only device showed only positive MR. Our results are discussed with respect to the actual models for MR in organic semiconductors. Our results are in good agreement with the bipolaron model. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Telecanthus, the lateral displacement of the medial canthus, can be a congenital deformity or can occur after facial trauma or tumor resection. Treatment of telecanthus remains a challenge for plastic surgeons. For proper correction, it is necessary to shift the medial canthus medially, fixing its tendon to the bone. The ideal technique would allow easy, safe, and stable fixation of the tendon, permit a unilateral approach with minimal incisions, and be cost-effective. The purpose of this study was to evaluate the feasibility and results (immediate and long-term) of medial telecanthus repair using ipsilateral titanium microanchor fixation. Nine patients, 7 with unilateral telecanthus and 2 with bilateral telecanthus, underwent ipsilateral canthopexy involving a microanchor device. Anthropometric measurements of the orbital regions were taken before, immediately after, and at 1 year after surgery. Data for the affected sides were compared with those for the unaffected sides, and the evolution of those values was assessed throughout the 1-year follow-up period. For all patients, the final values were lower than those initially obtained. At 1 year after surgery, the intercanthal distance was reduced to age-adjusted normal values in all cases. On the operated side, stable improvement was observed in terms of the distance from the medial canthus to the midline, although some degree of recurrence was noted in most of the patients. The use of a microanchor system for medial canthopexy can be considered an easily performed and effective option for treating canthal dystopia, especially when an ipsilateral approach is preferred.
Resumo:
Biologic valve re-replacement was examined in a series of 1343 patients who underwent aortic valve replacement at The Prince Charles Hospital, Brisbane, with a cryopreserved or 4 degrees C stored allograft valve or a xenograft valve, A parametric model approach was used to simultaneously model the competing risks of death without re-replacement and re-replacement before death, One hundred eleven patients underwent a first re-replacement for a variety of reasons (69 patients with xenograft valves, 28 patients with 4 degrees C stored allograft valves, and 14 patients with cryopreserved allograft valves), By multivariable analysis younger age at operation was associated with xenograft, 4 degrees C stored allograft, and cryopreserved allograft valve re-replacement, However, this effect was examined in the context of longer survival of younger patients, which increases their exposure to the risk of re-replacement as compared with that in older patients whose decreased survival reduced their probability of requiring valve re-replacement, In patients older than 60 years at the time of aortic valve replacement, the probability of re-replacement (for any reason) before death was similar for xenografts and cryopreserved allograft valves but higher for 4 degrees C stored valves, However, in patients younger than 60 years, the probability of re-replacement at any time during the remainder of the life of the patient was lower with the cryopreserved allograft valve compared with the xenograft valve and 4 degrees C stored allografts.
Resumo:
The fluorescence spectrum of a strongly driven two-level atom located inside an optical cavity damped by a narrow-bandwidth squeezed vacuum is studied. We use a dressed atom model approach, first applied to squeezed vacuum problems by Yeoman and Barnett, to derive the master equation of the system and discuss the role of the cavity and the squeezed vacuum in the narrowing of the spectral lines and the population trapping effect. We find that in the presence of a single-mode cavity the effect of squeezing on the fluorescence spectrum is more evident in the linewidths of the Rabi sidebands rather than in the linewidth of the central component. Even in the absence of squeezing, the cavity can reduce the linewidth of the central component almost to zero, whereas the Rabi sidebands can be narrowed only to some finite value. In the presence of a two-mode cavity and a two-mode squeezed vacuum the signature of squeezing is evident in the linewidths of all spectral lines. We also establish that the narrowing of the spectral lines is very sensitive to the detuning of the driving field from the atomic resonance. Moreover, we find that the population trapping effect, predicted for the broadband squeezed vacuum case, may appear in a narrow-bandwidth case only if the input squeezed modes are perfectly matched to the cavity modes and if there is non-zero squeezing at the Rabi sidebands.
Resumo:
The balance between different immunological stimuli is essential in the progression and stabilization of atherosclerotic plaques. Immune regulation has been suggested as potential target for the treatment of atherosclerotic disease. We sought to determine whether treatment with pentoxifylline, a phosphodiesterase inhibitor with immunomodulating properties, could reduce the pro-inflammatory response observed in patients with acute coronary syndromes (ACS) and increase anti-inflammatory activity. In a double-blind, prospective, placebo-controlled study, 64 patients with ACS were randomized to receive pentoxifylline 400 mg TID or placebo for 6 months. Analysis of the pro-inflammatory markers, Greactive protein (CRP), interleukin (IL)-6, IL-12, interferon-gamma and tumor necrosis factor (TNF)-alpha and the anti-inflammatory cytokines, transforming growth factor (TGF)-beta 1 and IL-10 were done at baseline, 1 and 6 months. Pentoxifylline treatment significantly reduced the adjusted levels of CRP and TNF-alpha compared to placebo after 6 months (P=0.04 and P < 0.01, respectively). IL-12 increase was significantly less pronounced with pentoxifylline (P=0.04). The levels of the anti-inflammatory cytokine, IL-10, also declined significantly less in the pentoxifylline group compared to placebo (P < 0.01) with a trend towards a higher increase of TGF-beta 1 in the former group (P=0.16). Pentoxifylline reduces pro-inflammatory and increases anti-inflammatory response in patients with ACS and may have beneficial clinical effects on cardiovascular events. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Fatty liver disease is a problem in both bariatric patients and in patients with moderate obesity. Tumor necrosis factor (TNF)-alpha has been frequently measured in nonalcoholic steatohepatitis (NASH) with or without diabetes, but less is known about interleukin (IL)-6 and IL-10. Moderately obese patients (n = 80) with histologically proven steatosis (n = 29) and NASH (n = 51) were recruited. Serum levels of cytokines were documented along with clinical information. The aim was to identify the correlates of such biomolecules in a stable population. Diabetes tended to be more associated with NASH (52.5% instead of 41.4%, P = 0.015), with no difference of age, gender, or body mass index regarding steatosis. For the entire population, cytokine changes were not significant, including TNF-alpha and IL-6. In diabetics only, all markers tended to diminish with NASH, especially IL-10 (P = 0.000). IL-10 correlated with homeostatic model assessment index (P = 0.000) and other variables of glucose homeostasis in diabetes, thus representing a major marker of the disease. (1) Generally inconsistent changes in pro- and anti-inflammatory cytokines occurred when NASH was globally compared to steatosis. (2) In contrast, downregulation of IL-6 and IL-10 was perceived in diabetics with NASH. (3) Arterial hypertension did not play a role in these circumstances. (4) IL-10 maintained strong correlations with glucose metabolism indices. (5) TNF-alpha could not be incriminated for progressive liver damage, as values failed to increase in NASH. (6) Investigations of IL-10 and other counterregulatory cytokines are lacking in this context and deserve further studies.
Thermogravimetric analytical procedures for determining reactivities of chars from New Zealand coals
Resumo:
Tightly constrained thermogravimetric experimental procedures (particle size < 212 mu m, sample mass 15.5 mg, CO2 reactant gas, near isothermal conditions) allow the reactivity of chars from high volatile New Zealand coals to be determined to a repeatability of +/-0.07 h(-1) at 900 degrees C and +/-0.5 h(-1) at 1100 degrees C. The procedure also provides proximate analyses information and affords a quick (< 90 min) comparison between different coal types as well as indicating likely operating conditions and problems associated with a particular coal or blend. A clear difference is evident between reactivities of differing New Zealand coal ranks. Between 900 and 1100 degrees C, bituminous coals increase thirtyfold in reactivity compared with fourfold for subbituminous, with the latter being three to five times greater in reactivity at higher temperature. (C) 1997 Elsevier Science B.V.
Resumo:
Background. Several medical devices used during hemodynamic procedures, particularly angiographic diagnostic and therapeutic cardiac catheters, are manufactured for single use only. However, reprocessing and reuse of these devices has been reported, to determine the frequency of reuse and reprocessing of single-use medical devices used during hemodynamic procedures in Brazil and to evaluate how reprocessing is performed. Design. National survey, conducted from December 1999 to July 2001. Methods. Most of the institutions affiliated with the Brazilian Society of Hemodynamic and Interventional Cardiology were surveyed by use of a questionnaire sent in the mail. Results. The questionnaire response rate was 50% (119 of 240 institutions). Of the 119 institutions that responded, 116 (97%) reported reuse of single-use devices used during hemodynamic procedures, and only 26 (22%) reported use of a standardized reprocessing protocol. Cleaning, flushing, rinsing, drying, sterilizing and packaging methods varied greatly and were mostly inadequate. Criteria for discarding reused devices varied widely. Of the 119 institutions that responded, 80 (67%) reported having a surveillance system for adverse events associated with the reuse of medical devices, although most of these institutions did not routinely review the data, and only 38 (32%) described a training program for the personnel who reprocessed single-use devices. Conclusions. The reuse of single-use devices used during hemodynamic procedures was very frequent in hospitals in Brazil. Basic guidance on how to reuse and reprocess single-use medical devices is urgently needed, because, despite the lack of studies to support reusing and reprocessing single-use medical devices, such devices are necessary in limited-resource areas in which these practices are current.
Resumo:
Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
Resumo:
A biofilm is a complex community of surface-associated cells enclosed in a polymer matrix. They attach to solid surfaces and their formation can be affected by growth conditions and co-infection with other pathogens. The presence of biofilm may protect the microorganisms from host defenses, as well as significantly reduce their susceptibility to antifungal agents. Pathogenic microbes can form biofilms on the inert surfaces of implanted devices such as catheters, prosthetic cardiac valves and intrauterine devices (IUDs). The present study was carried out to analyze the presence of biofilm on the surface of intrauterine devices in patients with recurrent vulvovaginal candidiasis, and to determine the susceptibility profile of the isolated yeasts to amphotericin B and fluconazole. Candida albicans was recovered from the IUDs and it was found to be susceptible to the antifungal agents when tested under planktonic growing conditions. These findings indicate the presence of the biofilm on the surface of the IUD as an important risk factor for recurrent vulvovaginal candidiasis.
Resumo:
Olm MA, Kogler JE Jr, Macchione M, Shoemark A, Saldiva PH, Rodrigues JC. Primary ciliary dyskinesia: evaluation using cilia beat frequency assessment via spectral analysis of digital microscopy images. J Appl Physiol 111: 295-302, 2011. First published May 5, 2011; doi:10.1152/japplphysiol.00629.2010.-Ciliary beat frequency (CBF) measurements provide valuable information for diagnosing of primary ciliary dyskinesia (PCD). We developed a system for measuring CBF, used it in association with electron microscopy to diagnose PCD, and then analyzed characteristics of PCD patients. 1 The CBF measurement system was based on power spectra measured through digital imaging. Twenty-four patients suspected of having PCD (age 1-19 yr) were selected from a group of 75 children and adolescents with pneumopathies of unknown causes. Ten healthy, nonsmoking volunteers (age >= 17 yr) served as a control group. Nasal brush samples were collected, and CBF and electron microscopy were performed. PCD was diagnosed in 12 patients: 5 had radial spoke defects, 3 showed absent central microtubule pairs with transposition, 2 had outer dynein arm defects, 1 had a shortened outer dynein arm, and 1 had a normal ultrastructure. Previous studies have reported that the most common cilia defects are in the dynein arm. As expected, the mean CBF was higher in the control group (P < 0.001) and patients with normal ultrastructure (P < 0.002), than in those diagnosed with cilia ultrastructural defects (i.e., PCD patients). An obstructive ventilatory pattern was observed in 70% of the PCD patients who underwent pulmonary function tests. All PCD patients presented bronchial wall thickening on chest computed tomography scans. The protocol and diagnostic techniques employed allowed us to diagnose PCD in 16% of patients in this study.
Resumo:
The traditional methods employed to detect atherosclerotic lesions allow for the identification of lesions; however, they do not provide specific characterization of the lesion`s biochemistry. Currently, Raman spectroscopy techniques are widely used as a characterization method for unknown substances, which makes this technique very important for detecting atherosclerotic lesions. The spectral interpretation is based on the analysis of frequency peaks present in the signal; however, spectra obtained from the same substance can show peaks slightly different and these differences make difficult the creation of an automatic method for spectral signal analysis. This paper presents a signal analysis method based on a clustering technique that allows for the classification of spectra as well as the inference of a diagnosis about the arterial wall condition. The objective is to develop a computational tool that is able to create clusters of spectra according to the arterial wall state and, after data collection, to allow for the classification of a specific spectrum into its correct cluster.
Resumo:
The immunologic characterization of chronic idiopathic urticaria (CIU), mainly regarding cytokine profile needs more investigation. We examined circulating inflammatory cytokine levels, T-cell induced secretion, and cytokine mRNA expression in patients with CIU subjected to the intradermal autologous serum skin test (ASST). Increased levels of circulating pro-inflammatory cytokines, such as TNF-alpha, IL-1 beta, IL-12p70, and IL-6 have been observed in most of patients with CIU, together with an enhancement of IL-2 secretion following T-cell stimulation. Highlighting the inflammatory profile in CIU found in ASST positive, is the enhanced B-cell proliferative responsiveness and increased IL-17 secretion levels. ASST-positive patients also exhibited impaired IL-4 secretion associated with increased IL-10 production. Altered cytokine expression in patients with ASST-negative, was the down-modulation of spontaneous IL-10 mRNA expression levels in peripheral blood mononuclear cells. Our findings support the concept of immunologic dysregulation in CIU, revealing a systemic inflammatory profile associated with disturbed cytokine production by T cells, mainly related to IL-17 and IL-10 production. (c) 2008 Elsevier B.V. All rights reserved.