976 resultados para 48-1
Resumo:
OBJECTIVES: The purpose of this research was to determine the relative safety and efficacy of multiple (> or =2) overlapping Cypher sirolimus-eluting stents (SES) (Johnson ; Johnson, New Brunswick, New Jersey). BACKGROUND: Overlapping coronary stents are common. The periprocedural and late clinical and angiographic consequences of overlapped coronary stents are not clearly defined, particularly for drug-eluting stents. METHODS: All patients enrolled into five clinical trials of the SES were analyzed. Three of these trials were prospective randomized comparisons of the SES to the bare-metal stent (BMS), and two were prospective non-randomized trials of SES-treated patients with historical controls. All clinical and angiographic outcomes in overlap-stent-treated patients were compared by stent type and with single-stent-treated patients for the same stent device. RESULTS: In all, 575 patients with stent overlap (337 SES, 238 BMS) and 1,162 patients with single stents (697 SES, 465 BMS) were analyzed. Stent overlap was associated with a greater late lumen loss in stent and more frequent angiographic restenosis regardless of stent type. Among overlap-stent-treated patients, the SES provided similar magnitude of restenosis benefit as observed for single-stent-treated patients. Overlapped SES was not associated with an increase in myocardial infarction. CONCLUSIONS: The strategy of SES overlap, when required, is both safe and efficacious in reducing restenosis with no increase in the incidence of myocardial infarction or major adverse cardiovascular events, when compared with a bare metal coronary stent prosthesis.
Resumo:
The pharmacokinetic interaction between atovaquone, a 1,4-hydroxynaphthoquinone, and zidovudine was examined in an open, randomized, three-phase crossover study in 14 patients infected with human immunodeficiency virus. Atovaquone (750 mg every 12 hours) and zidovudine (200 mg every 8 hours) were given orally alone and in combination. Atovaquone significantly increased the area under the zidovudine concentration-time curve (AUC) (1.82 +/- 0.62 micrograms.hr/ml versus 2.39 +/- 0.68 micrograms.hr/ml; p < 0.05) and decreased the oral clearance of zidovudine (2029 +/- 666 ml/min versus 1512 +/- 464 ml/min; p < 0.05). In contrast, atovaquone tended to decrease the AUC of zidovudine-glucuronide (7.31 +/- 1.51 micrograms.hr/ml versus 6.89 +/- 1.42 micrograms.hr/ml; p < 0.1) and significantly decreased the ratio of AUC zidovudine-glucuronide/AUC zidovudine (4.48 +/- 1.94 versus 3.12 +/- 1.1; p < 0.05). The maximum concentration of zidovudine-glucuronide was significantly lowered by atovaquone (5.7 +/- 1.5 versus 4.57 +/- 0.97 micrograms/ml; p < 0.05). Zidovudine had no effect on the pharmacokinetic disposition of atovaquone. Atovaquone appears to increase the AUC of zidovudine by inhibiting the glucuronidation of zidovudine.
Resumo:
OBJECTIVE: The objective of this study was to analyze the autonomic functions of patients with erythrophobia. METHODS: Forty patients with a diagnosis of erythrophobia (female/male ratio 18/22) without any other organic lesions and 20 healthy volunteers (female/male ratio 10/10) were assessed. Clinical evaluation was performed using a modified version of semistructured interviews. Autonomic testing was performed by means of spectral analysis of heart rate and continuous blood pressure by sparse discrete Fourier transformation at rest and under mental stress. RESULTS: There were no significant difference between the two samples in age, sex distribution, BMI, resting systolic, or diastolic blood pressure, nor was there a difference in autonomic baseline functioning between the 40 patients with erythrophobia and the control subjects. On the other hand, patients with erythrophobia consistently showed higher pulse rates (88 +/- 20 vs. 78 +/- 9 bpm, p <.05), higher total heart rate power values (8.40 +/- 0.63 vs. 8.07 +/- 1.02 p <.05), higher midfrequency spectral values (7.38 +/- 0.66 vs. 7.02 +/- 1.18, p <.01), higher high-frequency spectral values (6.89 +/- 0.86 vs. 6.48 +/- 1.44, p <.05), and lower baroreceptor sensitivity (8.62 +/- 8.16 vs. 11.65 +/- 4.42, p <.005) than the healthy subjects. ANOVA showed a significant group interaction (p <.0001) between the samples. CONCLUSIONS: This study provides evidence for abnormal autonomic functioning in patients with erythrophobia when under mental stress.
Resumo:
INTRODUCTION: A multi-centre study has been conducted, during 2005, by means of a questionnaire posted on the Italian Society of Emergency Medicine (SIMEU) web page. Our intention was to carry out an organisational and functional analysis of Italian Emergency Departments (ED) in order to pick out some macro-indicators of the activities performed. Participation was good, in that 69 ED (3,285,440 admissions to emergency services) responded to the questionnaire. METHODS: The study was based on 18 questions: 3 regarding the personnel of the ED, 2 regarding organisational and functional aspects, 5 on the activity of the ED, 7 on triage and 1 on the assessment of the quality perceived by the users of the ED. RESULTS AND CONCLUSION: The replies revealed that 91.30% of the ED were equipped with data-processing software, which, in 96.83% of cases, tracked the entire itinerary of the patient. About 48,000 patients/year used the ED: 76.72% were discharged and 18.31% were hospitalised. Observation Units were active in 81.16% of the ED examined. Triage programmes were in place in 92.75% of ED: in 75.81% of these, triage was performed throughout the entire itinerary of the patient; in 16.13% it was performed only symptom-based, and in 8.06% only on-call. Of the patients arriving at the ED, 24.19% were assigned a non-urgent triage code, 60.01% a urgent code, 14.30% a emergent code and 1.49% a life-threatening code. Waiting times were: 52.39 min for non-urgent patients, 40.26 min for urgent, 12.08 for emergent, and 1.19 for life-threatening patients.
Resumo:
Auszug Im November 2006 stellten die Vereinten Nationen (UN) den jüngsten von einem unabhängigen Experten erstellten internationalen Bericht zu Gewalt an Kindern vor, wonach im Jahre 2002 weltweit schätzungsweise 53.000 Kinder durch Totschlag starben sowie 150 Mio. Mädchen und 73 Mio. Jungen unter 18 Jahren Opfer sexueller Misshandlungen wurden. In 31 von 200 Staaten sind körperliche Strafen von Auspeitschen bis Amputationen erlaubt und in knapp der Hälfte der Staaten ist die Körperstrafe an Schulen erlaubt (Pinheiro 2006). In Deutschland und Großbritannien sterben pro Woche zwei, in Frankreich drei, in Japan vier und in USA 27 Kinder an Misshandlung und Vernachlässigung. In einer vorangegangen Studie der UNICEF, dem Kinderhilfswerk der Vereinten Nationen, wurde festgestellt, dass in den reichen Ländern auf 100.000 Kinder jährlich zwischen 0, 1 und 3, 7 Kinder unter 15 Jahren als Folge von Misshandlung oder Vernachlässigung sterben (⊡ Abb. 48.1 ). Schätzungen gehen davon aus, dass auf einen Todesfall rund 150 Fälle von Kindesmisshandlung ohne Todesfolge kommen (UNICEF 2003).
Resumo:
In this paper we prove a Lions-type compactness embedding result for symmetric unbounded domains of the Heisenberg group. The natural group action on the Heisenberg group TeX is provided by the unitary group U(n) × {1} and its appropriate subgroups, which will be used to construct subspaces with specific symmetry and compactness properties in the Folland-Stein’s horizontal Sobolev space TeX. As an application, we study the multiplicity of solutions for a singular subelliptic problem by exploiting a technique of solving the Rubik-cube applied to subgroups of U(n) × {1}. In our approach we employ concentration compactness, group-theoretical arguments, and variational methods.
Resumo:
Key performance features of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations of the chemical composition of planetary surfaces are presented. This mass spectrometer is well suited for elemental and isotopic analysis of raw solid materials with high sensitivity and high spatial resolution. In this study, ultraviolet laser radiation with irradiances suitable for ablation (< 1 GW/cm2) is used to achieve stable ion formation and low sample consumption. In comparison to our previous laser ablation studies at infrared wavelengths, several improvements to the experimental setup have been made, which allow accurate control over the experimental conditions and good reproducibility of measurements. Current performance evaluations indicate significant improvements to several instrumental figures of merit. Calibration of the mass scale is performed within a mass accuracy (Δm/m) in the range of 100 ppm, and a typical mass resolution (m/Δm) ~600 is achieved at the lead mass peaks. At lower laser irradiances, the mass resolution is better, about (m/Δm) ~900 for lead, and limited by the laser pulse duration of 3 ns. The effective dynamic range of the instrument was enhanced from about 6 decades determined in previous study up to more than 8 decades at present. Current studies show high sensitivity in detection of both metallic and non-metallic elements. Their abundance down to tens of ppb can be measured together with their isotopic patterns. Due to strict control of the experimental parameters, e.g. laser characteristics, ion-optical parameters and sample position, by computer control, measurements can be performed with high reproducibility. Copyright © 2012 John Wiley & Sons, Ltd.