867 resultados para strengths-focused
Resumo:
Background During the few years that have passed since it became available, the Strengths and Difficulties Questionnaire (SDQ) has been extensively evaluated and widely applied to assess behaviour disorders of children and adolescents in European countries. In contrast, relatively few reports have published SDQ results obtained in other parts of the world, although its briefness and availability in over 40 languages make this instrument particularly attractive for international collaborations and cross-cultural comparisons concerning clinical and epidemiological issues. Objectives This initial overview summarises some of these non-European experiences with the SDQ by presenting a selection of projects that have either psychometrically evaluated this novel questionnaire, applied it to screen for behaviour disorders, or employed its parent-, teacher- or self-rated versions as research tools. Since a large part of the mentioned studies are ongoing or have only recently been completed, much of the work reported here is still unpublished. Conclusions Across a huge variety of cultures and languages, experience gained with the SDQ in other continents has supported European evidence of good psychometric properties and clinical utility of this questionnaire. Since worldwide usage of the SDQ can be expected to increase in the future, more international coordination is encouraged, in order to fully exploit the promising potentials of this versatile assessment tool and systematically investigate cross-cultural differences and similarities in child and adolescent behaviour.
Resumo:
Energies and wavefunctions are calculated for the bound states of the helium atom in the hyperspherical adiabatic approach by the full inclusion of nonadiabatic couplings. We show that the use of appropriate asymptotic radial boundary conditions not only allows the efficient calculation of energies accurate up to a few ppm for the ground state but also gives increasingly precise results for high-lying excited states with a unique set of equations. The accuracy of the wavefunctions is demonstrated by the calculation of oscillator strengths in the length form for transitions between stares ii S-1(e) and (n + 1) P-1(0) up to n = 29, in agreement with variational calculations.
Resumo:
The present study is aimed to diagnose the current public programs focused on herbal medicines in Brazil by means of in loco visits to 10 programs selected by means of questionnaires sent to 124 municipalities that count on herbal medicine services. The main purpose of the implementation of program programs is related to the development of medicinal herbs. 70% of them are intended for the production of herbal medicines and 50% are aimed to ensure the access of the population to medicinal plants and or herbal medicines. The initiative of the implementation of these programs was related to the managers (60%). The difficulties in this implementation were due to the lack of funding (100%) of the programs. In 60% of the programs, the physicians did not adhere to herbal medicine services due to the lack of knowledge of the subject. Training courses were proposed (80%) to increase the adhesion of prescribers to the system. Some municipalities use information obtained from patients to assess the therapeutic efficiency of medicinal plants and herbal medicines. of the programs underway, cultivation of medicinal plants was observed in 90% and 78% of them adopt quality control. In most programs, this control is not performed in accordance with the legal requirements. The programs focused on medicinal plants and herbal medicines implemented in Brazil face sonic chronic problems of infrastructure, management, operational capacity and self-sustainability, which can be directly related to the absence of a national policy on medicinal plants and herbal medicines.
Resumo:
Due to gradual resorption of the edentulous ridge bone, removable prostheses often require denture base relines to improve fit and stability. This research evaluated the bond strength between one heat-cured acrylic resin (Lucitone 550®) and two hard chairside reline resins, after two different periods of storage in water (50 h and 30 days). The bond strength was evaluated using a tensile test. The mode of failure, adhesive or cohesive, was also recorded. The results submitted to the Kruskal-Wallis test indicated that the highest tensile strengths were achieved with intact Lucitone 550® denture base resin in both periods of storage in water. After 50 h of storage in water, Duraliner II® reline material exhibited the highest bond strength to the denture base resin. After 30 days of storage in water, Duraliner II® reline resin demonstrated a significant reduction in adhesion, showing lower tensile bond strength than Kooliner® material. Both hard chairside reline materials failed adhesively across Lucitone 550® denture base resin, in both periods of time. © 1999 Blackwell Science Ltd.
Resumo:
Purpose: This study evaluated the potential effects of denture base resin water storage time and an effective denture disinfection method (microwave irradiation at 650 W for 6 minutes) on the torsional bond strength between two hard chairside reline resins (GC Reline and New Truliner) and one heat-polymerizing denture base acrylic resin (Lucitone 199). Materials and Methods: Cylindrical (30 x 3.9 mm) denture base specimens (n = 160) were stored in water at 37°C (2 or 30 days) before bonding. A section (3.0 mm) was removed from the center of the specimens, surfaces prepared, and the reline materials packed into the space. After polymerization, specimens were divided into four groups (n = 10): Group 1 (G1) - tests performed after bonding; Group 2 (G2) - specimens immersed in water (200 ml) and irradiated twice (650 W for 6 minutes); Group 3 (G3) - specimens irradiated daily until seven cycles of disinfection; Group 4 (G4) - specimens immersed in water (37°C) for 7 days. Specimens were submitted to a torsional test (0.1 Nm/min), and the torsional strengths (MPa) and the mode of failure were recorded. Data from each reline material were analyzed by a two-way analysis of variance, followed by Neuman-Keuls test (p = 0.05). Results: For both Lucitone 199 water storage periods, before bonding to GC Reline resin, the mean torsional strengths of G2 (2 days - 138 MPa; 30 days - 132 MPa), G3 (2 days - 126 MPa; 30 days - 130 MPa), and G4 (2 days - 130 MPa; 30 days - 137 MPa) were significantly higher (p < 0.05) than G1 (2 days - 108 MPa; 30 days - 115 MPa). Similar results were found for Lucitone 199 specimens bonded to New Truliner resin, with G1 specimens (2 days - 73 MPa; 30 days - 71 MPa) exhibiting significantly lower mean torsional bond strength (p < 0.05) than G2 (2 day - 86 MPa; 30 days - 90 MPa), G3 (2 days - 82 MPa; 30 days - 82 MPa), and G4 specimens (2 days - 78 MPa; 30 days - 79 MPa). The adhesion of both materials was not affected by water storage time of Lucitone 199 (p > 0.05). GC reline showed a mixed mode of failure (adhesive/cohesive) and New Truliner failed adhesively. Conclusions: Up to seven microwave disinfection cycles did not decrease the torsional bond strengths between the hard reline resins, GC Reline and New Truliner to the denture base resin Lucitone 199. The effect of additional disinfection cycles on reline material may be clinically significant and requires further study. Copyright © 2006 by The American College of Prosthodontists.
Resumo:
This study aimed to compare in vitro the shear bond strength between metallic brackets (Abzil) with conventional mesh bases and metallic brackets with bases industrially sandblasted with aluminum oxide using three adhesive systems, in order to assess the influence of sandblasting on adhesiveness and to compare 3 different bonding systems. Two hundred and forty bovine incisors were used and randomly divided into 6 groups (40 teeth in each group), according to the bracket base and to the bonding system. The brackets were direct-bonded in bovine teeth with 3 adhesive systems: System A - conventional Transbond™ XT (3M -Unitek); System B - Transbond™ Plus Self Etching Primer + Transbond™ XT (3M - Unitek) and System C - Fuji ORTHO LC resin-reinforced glass ionomer cement in capsules (GC Corp.). Shear bond strength tests were performed 24 hours after bonding, in a DL-3000 universal testing machine (EMIC), using a load cell of 200 kgf and a speed of 1 mm/min. The results were submitted to statistical analysis and showed no significant difference between conventional and sandblasted bracket bases. However, comparison between the bonding systems presented significantly different results. System A (14.92 MPa) and system C (13.24 MPa) presented statistically greater shear bond strength when compared to system B (10.66 MPa). There was no statistically significant difference between system A and system C.
Resumo:
Includes bibliography
Resumo:
Dengue virus is a mosquito-borne flavivirus that has a large impact in global health. It is considered as one of the medically important arboviruses, and developing a preventive or therapeutic solution remains a top priority in the medical and scientific community. Drug discovery programs for potential dengue antivirals have increased dramatically over the last decade, largely in part to the introduction of high-throughput assays. In this study, we have developed an image-based dengue high-throughput/high-content assay (HT/HCA) using an innovative computer vision approach to screen a kinase-focused library for anti-dengue compounds. Using this dengue HT/HCA, we identified a group of compounds with a 4-(1-aminoethyl)-N-methylthiazol-2-amine as a common core structure that inhibits dengue viral infection in a human liver-derived cell line (Huh-7.5 cells). Compounds CND1201, CND1203 and CND1243 exhibited strong antiviral activities against all four dengue serotypes. Plaque reduction and time-of-addition assays suggests that these compounds interfere with the late stage of viral infection cycle. These findings demonstrate that our image-based dengue HT/HCA is a reliable tool that can be used to screen various chemical libraries for potential dengue antiviral candidates. © 2013 Cruz et al.
Resumo:
Includes bibliography
Resumo:
Incluye Bibliografía
Resumo:
The major challenge for a greater dissemination of in vitro produced (IVP) bovine embryos is to improve embryonic survival after cryopreservation. The involvement of embryonic lipids on this issue is well documented. However, it has been recognized that not only the amount of lipids that affects embryo cryotolerance, but the embryo survival capacity after cryopreservation is a rather multifactorial event. In this review, some strategies to improve embryonic lipid composition and postcryopreservation survival by modifying the embryos themselves to make them more cryopreservable are overviewed. The use of semi-defined and defined serum-free culture media, the addition of some chemicals in the culture media to modify embryo lipid composition, and the modulation of embryo cell membrane fluidity by cholesterol or unsaturated fatty acids added to the culture media and oocyte/embryo donor nutritional management with a diet enriched in polyunsaturated fatty acids, were described as alternatives for the improvement of IVP embryo survival after cryopreservation.