848 resultados para parallel benchmarks
Resumo:
ABSTRACT: The thermal entry region in laminar forced convection of Herschel-Bulkley fluids is solved analytically through the integral transform technique, for both circular and parallel-plates ducts, which are maintained at a prescribed wall temperature or at a prescribed wall heat flux. The local Nusselt numbers are obtained with high accuracy in both developing and fully-developed thermal regions, and critical comparisons with previously reported numerical results are performed.
Stress analysis in oral obturator prostheses over parallel and tilted implants: photoelastic imaging
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The increasing amount of sequences stored in genomic databases has become unfeasible to the sequential analysis. Then, the parallel computing brought its power to the Bioinformatics through parallel algorithms to align and analyze the sequences, providing improvements mainly in the running time of these algorithms. In many situations, the parallel strategy contributes to reducing the computational complexity of the big problems. This work shows some results obtained by an implementation of a parallel score estimating technique for the score matrix calculation stage, which is the first stage of a progressive multiple sequence alignment. The performance and quality of the parallel score estimating are compared with the results of a dynamic programming approach also implemented in parallel. This comparison shows a significant reduction of running time. Moreover, the quality of the final alignment, using the new strategy, is analyzed and compared with the quality of the approach with dynamic programming.
Resumo:
This paper presents the design of a high-speed coprocessor for Elliptic Curve Cryptography over binary Galois Field (ECC- GF(2m)). The purpose of our coprocessor is to accelerate the scalar multiplication performed over elliptic curve points represented by affine coordinates in polynomial basis. Our method consists of using elliptic curve parameters over GF(2163) in accordance with international security requirements to implement a bit-parallel coprocessor on field-programmable gate-array (FPGA). Our coprocessor performs modular inversion by using a process based on the Stein's algorithm. Results are presented and compared to results of other related works. We conclude that our coprocessor is suitable for comparing with any other ECC-hardware proposal, since its speed is comparable to projective coordinate designs.
Resumo:
Sao Paulo State Research Foundation-FAPESP
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The resistive-type superconducting fault current limiters (RSFCL) prototypes using YBCO-coated conductors have shown current limitation for medium voltage class applications for acting time up to 80 ms. By connecting an air-core reactor in parallel with the RSFCL, thus making an hybrid current limiter, one can extend the acting time for up to 1 s. In this work, we report the performance of a hybrid current limiter subjected to an AC peak fault current of 2 kA during 1 s for which within the first 80 ms the SFCL limits the current concurrently with the air-core reactor, and for the remaining 920 ms, only the air-core reactor limits the current. In order to evaluate the actual conditions for subsequent reconnection of RSFCL to the power grid, the hybrid fault current limiter was tested varying the time interval for recovery from 900 ms and 1.2 s, followed again by the concurrent operation of the hybrid limiter during 1 s (SFCL during 80 ms). From this evaluation test, the recovery time can be measured and compared using the voltage peak generated in superconducting module from the first and second fault test. The recovery time was also determined through the pulsed current method (PCM) on short-length sample test. The results showed that the fault current was limited from 1.9 kA down to 514 A after 1 cycle of 60 Hz frequency, with recovery time lower than 1.2 s for two subsequent fault current tests.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We aimed to develop site-specific sediment quality guidelines (SQGs) for two estuarine and port zones in Southeastern Brazil (Santos Estuarine System and Paranagua Estuarine System) and three in Southern Spain (Ria of Huelva, Bay of Cadiz, and Bay of Algeciras), and compare these values against national and traditionally used international benchmark values. Site-specific SQGs were derived based on sediment physical-chemical, toxicological, and benthic community data integrated through multivariate analysis. This technique allowed the identification of chemicals of concern and the establishment of effects range correlatively to individual concentrations of contaminants for each site of study. The results revealed that sediments from Santos channel, as well as inner portions of the SES, are considered highly polluted (exceeding SQGs-high) by metals, PAHs and PCBs. High pollution by PAHs and some metals was found in Sao Vicente channel. In PES, sediments from inner portions (proximities of the Ponta do Mix port`s terminal and the Port of Paranagua) are highly polluted by metals and PAHs, including one zone inside the limits of an environmental protection area. In Gulf of Cadiz, SQGs exceedences were found in Ria of Huelva (all analysed metals and PAHs), in the surroundings of the Port of CAdiz (Bay of CAdiz) (metals), and in Bay of Algeciras (Ni and PAHs). The site-specific SQGs derived in this study are more restricted than national SQGs applied in Brazil and Spain, as well as international guidelines. This finding confirms the importance of the development of site-specific SQGs to support the characterisation of sediments and dredged material. The use of the same methodology to derive SQGs in Brazilian and Spanish port zones confirmed the applicability of this technique with an international scope and provided a harmonised methodology for site-specific SQGs derivation. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
This long-term extension of an 8-week randomized, naturalistic study in patients with panic disorder with or without agoraphobia compared the efficacy and safety of clonazepam (n = 47) and paroxetine (n = 37) over a 3-year total treatment duration. Target doses for all patients were 2 mg/d clonazepam and 40 mg/d paroxetine (both taken at bedtime). This study reports data from the long-term period (34 months), following the initial 8-week treatment phase. Thus, total treatment duration was 36 months. Patients with a good primary outcome during acute treatment continued monotherapy with clonazepam or paroxetine, but patients with partial primary treatment success were switched to the combination therapy. At initiation of the long-term study, the mean doses of clonazepam and paroxetine were 1.9 (SD, 0.30) and 38.4 (SD, 3.74) mg/d, respectively. These doses were maintained until month 36 (clonazepam 1.9 [ SD, 0.29] mg/d and paroxetine 38.2 [SD, 3.87] mg/d). Long-term treatment with clonazepam led to a small but significantly better Clinical Global Impression (CGI)-Improvement rating than treatment with paroxetine (mean difference: CGI-Severity scale -3.48 vs -3.24, respectively, P = 0.02; CGI-Improvement scale 1.06 vs 1.11, respectively, P = 0.04). Both treatments similarly reduced the number of panic attacks and severity of anxiety. Patients treated with clonazepam had significantly fewer adverse events than those treated with paroxetine (28.9% vs 70.6%, P < 0.001). The efficacy of clonazepam and paroxetine for the treatment of panic disorder was maintained over the long-term course. There was a significant advantage with clonazepam over paroxetine with respect to the frequency and nature of adverse events.
Resumo:
In this article, we introduce two new variants of the Assembly Line Worker Assignment and Balancing Problem (ALWABP) that allow parallelization of and collaboration between heterogeneous workers. These new approaches suppose an additional level of complexity in the Line Design and Assignment process, but also higher flexibility; which may be particularly useful in practical situations where the aim is to progressively integrate slow or limited workers in conventional assembly lines. We present linear models and heuristic procedures for these two new problems. Computational results show the efficiency of the proposed approaches and the efficacy of the studied layouts in different situations. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Data visualization techniques are powerful in the handling and analysis of multivariate systems. One such technique known as parallel coordinates was used to support the diagnosis of an event, detected by a neural network-based monitoring system, in a boiler at a Brazilian Kraft pulp mill. Its attractiveness is the possibility of the visualization of several variables simultaneously. The diagnostic procedure was carried out step-by-step going through exploratory, explanatory, confirmatory, and communicative goals. This tool allowed the visualization of the boiler dynamics in an easier way, compared to commonly used univariate trend plots. In addition it facilitated analysis of other aspects, namely relationships among process variables, distinct modes of operation and discrepant data. The whole analysis revealed firstly that the period involving the detected event was associated with a transition between two distinct normal modes of operation, and secondly the presence of unusual changes in process variables at this time.