992 resultados para mass determination


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nitrogen removal coupled with sulfide oxidation has potential for the treatment of effluents from anaerobic reactors because they contain sulfide, which can be used as an endogenous electron donor for denitrification. This work evaluated the intrinsic kinetics of sulfide-oxidizing autotrophic denitrification via nitrate and nitrite in systems containing attached cells. Differential reactors were fed with nitrified synthetic domestic sewage and different sulfide concentrations. The intrinsic kinetic parameters of nitrogen removal were determined when the mass transfer resistance was negligible. This bioprocess could be described by a half-order kinetic model for biofilms. The half-order kinetic coefficients ranged from 0.425 to 0.658 mg N-1/2 L-1/2 h(-1) for denitrification via nitrite and from 0.190 to 0.609 mg N-1/2 L-1/2 h(-1) for denitrification via nitrate. In this latter, the lower value was due to the use of electrons donated from intermediary sulfur compounds whose formation and subsequent consumption were detected. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Determination of chlorine using the molecular absorption of aluminum mono-chloride (AlCl) at the 261.418 nm wavelength was accomplished by high-resolution continuum source molecular absorption spectrometry using a transversely heated graphite tube furnace with an integrated platform. For the analysis. 10 mu L of the sample followed by 10 mu L of a solution containing Al-Ag-Sr modifier, (1 g L-1 each), were directly injected onto the platform. A spectral interference due to the use of Al-Ag-Sr as mixed modifier was easily corrected by the least-squares algorithm present in the spectrometer software. The pyrolysis and vaporization temperatures were 500 degrees C and 2200 degrees C, respectively. To evaluate the feasibility of a simple procedure for the determination of chlorine in food samples present in our daily lives, two different digestion methods were applied, namely (A) an acid digestion method using HNO3 only at room temperature, and (B) a digestion method with Ag, HNO3 and H2O2, where chlorine is precipitated as a low-solubility salt (AgCl), which is then dissolved with ammonia solution. The experimental results obtained with method B were in good agreement with the certified values and demonstrated that the proposed method is more accurate than method A. This is because the formation of silver chloride prevented analyte losses by volatilization. The limit of detection (LOD, 3 sigma/s) for Cl in methods A and B was 18 mu g g(-1) and 9 mu g g(-1), respectively, 1.7 and 3.3 times lower compared to published work using inductively coupled plasma optical emission spectrometry, and absolute LODs were 2.4 and 1.2 ng, respectively. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple and fast method for the determination of Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen by quadrupole inductively coupled plasma spectrometry (q-ICP-MS) is described. Prior to analysis, samples (200 µL) were diluted 1:50 in a solution containing 0.01% v/v Triton® X-100 and 0.5% v/v nitric acid and directly analyzed by ICP-MS. The limits of detection of the method are 0.3, 0.03, 0.2, 0.04, 0.04, 0.03 and 0.03 µg L-1 for 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 82Se and 55Mn, respectively. For purposes of comparison and method validation, four ordinary bovine semen samples were directly analyzed by ICP-MS and by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GF AAS), with no statistical difference between the techniques at the 95% level when applying the t-test. Then, the proposed method was applied in the determinations of Ca, Cu, Fe, Mg, Mn, Se and Zn in collected samples of bovine semen from different breeds, which are used in reproduction programs and artificial insemination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The two main tools to determine the dynamical and physical parameters of exoplanet systems are the radial velocity (RV) measurements and, when available, transit timings. The two techniques are complementary: The RV's allow us to know some of the orbital elements while the transit timings allow us to obtain the orbital inclination and planetary radius, impossible of obtain from the RV, and to resolve the indetermination in the determination of the planet mass from the RV's. The space observation of transiting planets is however not limited to transit times. They extend to long periods of time and are precise enough to provide information on variations along the orbit. Besides the effects of stellar rotation, deserve mention the Doppler shift in the radiation flux, as consequence of stellar movement around the center of mass, or Beaming Effect (BE); the Ellipsoidal Variability (EV) due to the tidal deformation of the star due to the gravitation of its close companion; and the Reflection (ER) of the stellar radiation incident on the planet and re-emitted to the observer. In the case of large hot Jupiters, these effects are enhanced by the strong gravitational interaction and the analysis of the light variation allows us independent estimates of the mass and radius of planet. The planetary system CoRoT 3 is favorable for such analysis. In this case, the secondary is a brown dwarf whose mass is of the order of 22Mj. We show results obtained from the analysis of 35 RV measurements, 236999 photometric observations and 11 additional RV observations made during a transit to determine the star rotation via the Rossiter-McLaughlin effect. The results obtained from this determination are presented in this communication. The results are compared to those resulting from other determinations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a sample of planetary nebulae in the Galaxy's inner-disk and bulge is used to find the galactocentric distance that optimally separates these two populations in terms of their abundances. Statistical distance scales were used to investigate the distribution of abundances across the disk–bulge interface, while a Kolmogorov–Smirnov test was used to find the distance at which the chemical properties of these regions separate optimally. The statistical analysis indicates that, on average, the inner population is characterized by lower abundances than the outer component. Additionally, for the α-element abundances, the inner population does not follow the disk's radial gradient toward the Galactic Center. Based on our results, we suggest a bulge–disk interface at 1.5 kpc, marking the transition between the bulge and the inner disk of the Galaxy as defined by the intermediate-mass population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study of mass transport in polymeric membranes has grown in importance due to its potential application in many processes such as separation of gases and vapors, packaging, controlled drug release. The diffusion of a low molecular weight species in a polymer is often accompanied by other phenomena like swelling, reactions, stresses, that have not been investigated in all their aspects yet. Furthermore, novel materials have been developed that include inorganic fillers, reactive functional groups or ions, that make the scenery even more complicated. The present work focused on the experimental study of systems where the diffusion is accompanied by other processes; suitable models were also developed to describe the particular circumstances in order to understand the underlying concepts and be able to design the performances of the material. The effect of solvent-induced deformation in polymeric films during sorption processes was studied since the dilation, especially in constrained membranes, can cause the development of stresses and therefore early failures of the material. The bending beam technique was used to test the effects of the dilation and the stress induced in the polymer by penetrant diffusion. A model based on the laminate theory was developed that accounts for the swelling and is able to predict the stress that raise in the material. The addition of inorganic fillers affects the transport properties of polymeric films. Mixed matrix membranes based on fluorinated, high free volume matrices show attractive performances for separation purposes but there is a need for deeper investigation of the selectivity properties towards gases and vapors. A new procedure based on the NELF model was tested on the experimental data; it allows to predict solubility of every penetrant on the basis of data for one vapor. The method has proved to be useful also for the determination of the diffusion coefficient and for an estimation of the permeability in the composite materials. Oxygen scavenging systems can overcome lack of barrier properties in common polymers that forbids their application in sensitive applications as food packaging. The final goal of obtaining a membrane almost impermeable to oxygen leads to experimental times out of reach. Hence, a simple model was developed in order to describe the transport of oxygen in a membrane with also reactive groups and analyze the experimental data collected on SBS copolymers that show attractive scavenging capacity. Furthermore, a model for predicting the oxygen barrier behavior of a film formed as a blend of OSP in a common packaging material was built, considering particles capable of reactions with oxygen embedded in a non-reactive matrix. Perfluorosulphonic acid ionomers (PFSI) are capturing attention due to a high thermal and chemical resistance coupled with very peculiar transport properties, that make them appropriate to be used in fuel cells. The possible effect of different formation procedure was studied together with the swelling due to water sorption since both water uptake and dilation can dramatically affect the fuel cells performances. The water diffusion and sorption was studied with a FTIR-ATR spectrometer that can give deeper information on the bonds between water molecules and the sulphonic hydrophilic groups and, therefore, on the microstructure of the hydrated ionomer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

n this work, three Cypraea species (C. talpa, C. tigris and C. zebra) were exhaustively studied. The shells have been separated in the structural layers. The mineralogy, ultra- and micro-structure of each layer were analyzed by Confocal Laser Scanning Microscopy (CLSM), Scanning Electron Microscopy (SEM), X-Ray Diffractometry (XRD) and Raman Spectroscopy (RS). The presence of biologically relevant trace metals (Mn, Co, Fe, Zn, Cr, etc.) has been investigated using Instrumental Neutron Activation Analysis (INAA) and Inductively Coupled Plasma – Mass Spectrometry (ICP-MS) as detection tool. A new method has been developed and optimized to extract and analyze the soluble organic matrix (SOM) of the shell. Although the molecular nature of the SOM is not really known, it contains at least large protein fraction, if not only consists of proteins. The extracted matrices were compared between layers and species using Size Exclusion High Performance Liquid Chromatography coupled with Ultra Violet Spectrometry (SE-HPLC-UV), Gel electrophoresis (GE) and protein quantification tests. For the first time to our knowledge the association of trace elements to the protein in the SOM of the shell was studied using hyphenated on line as well as combined off line techniques and validated through inter-comparison tests between the different methods applied. Interesting correlations between the trace element concentration, the microstructure and the protein content were directly and indirectly detected. The metals Cu, Ni, Co and Zn have shown to bind to the SOM extracted from C. talpa, C. tigris and C. zebra shells. Within the conclusions of this work it was demonstrated that these protein-metal-complexes (or metal containing proteins) change from one layer to the other and are different between the three snails analyzed. In addition, the complexes are clearly related only to certain protein fractions of the SOM, and not to the whole SOM observed. These fractions and show not to be very metal-specific (i.e. some of these fractions bind two or three different metals).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drug abuse is a major global problem which has a strong impact not only on the single individual but also on the entire society. Among the different strategies that can be used to address this issue an important role is played by identification of abusers and proper medical treatment. This kind of therapy should be carefully monitored in order to discourage improper use of the medication and to tailor the dose according to the specific needs of the patient. Hence, reliable analytical methods are needed to reveal drug intake and to support physicians in the pharmacological management of drug dependence. In the present Ph.D. thesis original analytical methods for the determination of drugs with a potential for abuse and of substances used in the pharmacological treatment of drug addiction are presented. In particular, the work has been focused on the analysis of ketamine, naloxone and long-acting opioids (buprenorphine and methadone), oxycodone, disulfiram and bupropion in human plasma and in dried blood spots. The developed methods are based on the use of high performance liquid chromatography (HPLC) coupled to various kinds of detectors (mass spectrometer, coulometric detector, diode array detector). For biological sample pre-treatment different techniques have been exploited, namely solid phase extraction and microextraction by packed sorbent. All the presented methods have been validated according to official guidelines with good results and some of these have been successfully applied to the therapeutic drug monitoring of patients under treatment for drug abuse.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the main goals of the COMPASS experiment at CERN is the determination of the gluon polarisation in the nucleon. It is determined from spin asymmetries in the scattering of 160 GeV/c polarised muons on a polarised LiD target. The gluon polarisation is accessed by the selection of photon-gluon fusion (PGF) events. The PGF-process can be tagged through hadrons with high transverse momenta or through charmed hadrons in the final state. The advantage of the open charm channel is that, in leading order, the PGF-process is the only process for charm production, thus no physical background contributes to the selected data sample. This thesis presents a measurement of the gluon polarisation from the COMPASS data taken in the years 2002-2004. In the analysis, charm production is tagged through a reconstructed D0-meson decaying in $D^{0}-> K^{-}pi^{+}$ (and charge conjugates). The reconstruction is done on a combinatorial basis. The background of wrong track pairs is reduced using kinematic cuts to the reconstructed D0-candidate and the information on particle identification from the Ring Imaging Cerenkov counter. In addition, the event sample is separated into D0-candidates, where a soft pion from the decay of the D*-meson to a D0-meson, is found, and the D0-candidates without this tag. Due to the small mass difference between D*-meson and D0-meson the signal purity of the D*-tagged sample is about 7 times higher than in the untagged sample. The gluon polarisation is measured from the event asymmetries for the for the different spin configurations of the COMPASS target. To improve the statistical precision of the final results, the events in the final sample are weighted. This method results in an average value of the gluon polarisation in the x-range covered by the data. For the COMPASS data from 2002-2004, the resulting value of the gluon polarisation is $=-0.47+-0.44 (stat)+-0.15(syst.)$. The result is statistically compatible with the existing measurements of $$ in the high-pT channel. Compared to these, the open charm measurement has the advantage of a considerably smaller model dependence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The only nuclear model independent method for the determination of nuclear charge radii of short-lived radioactive isotopes is the measurement of the isotope shift. For light elements (Z < 10) extremely high accuracy in experiment and theory is required and was only reached for He and Li so far. The nuclear charge radii of the lightest elements are of great interest because they have isotopes which exhibit so-called halo nuclei. Those nuclei are characterized by a a very exotic nuclear structure: They have a compact core and an area of less dense nuclear matter that extends far from this core. Examples for halo nuclei are 6^He, 8^He, 11^Li and 11^Be that is investigated in this thesis. Furthermore these isotopes are of interest because up to now only for such systems with a few nucleons the nuclear structure can be calculated ab-initio. In the Institut für Kernchemie at the Johannes Gutenberg-Universität Mainz two approaches with different accuracy were developed. The goal of these approaches was the measurement of the isotope shifts between (7,10,11)^Be^+ and 9^Be^+ in the D1 line. The …first approach is laser spectroscopy on laser cooled Be^+ ions that are trapped in a linear Paul trap. The accessible accuracy should be in the order of some 100 kHz. In this thesis two types of linear Paul traps were developed for this purpose. Moreover, the peripheral experimental setup was simulated and constructed. It allows the efficient deceleration of fast ions with an initial energy of 60 keV down to some eV and an effcient transport into the ion trap. For one of the Paul traps the ion trapping could already be demonstrated, while the optical detection of captured 9^Be^+ ions could not be completed, because the development work was delayed by the second approach. The second approach uses the technique of collinear laser spectroscopy that was already applied in the last 30 years for measuring isotope shifts of plenty of heavier isotopes. For light elements (Z < 10), it was so far not possible to reach the accuracy that is required to extract information about nuclear charge radii. The combination of collinear laser spectroscopy with the most modern methods of frequency metrology …finally permitted the …first-time determination of the nuclear charge radii of (7,10)^Be and the one neutron halo nucleus 11^Be at the COLLAPS experiment at ISOLDE/ CERN. In the course of the work reported in this thesis it was possible to measure the absolute transition frequencies and the isotope shifts in the D1 line for the Be isotopes mentioned above with an accuracy of better than 2 MHz. Combination with the most recent calculations of the mass effect allowed the extraction of the nuclear charge radii of (7,10,11)^Be with an relative accuracy better than 1%. The nuclear charge radius decreases from 7^Be continuously to 10^Be and increases again for 11^Be. This result is compared with predictions of ab-initio nuclear models which reproduce the observed trend. Particularly the "Greens Function Monte Carlo" and the "Fermionic Molecular Dynamic" model show very good agreement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Der Einsatz von Penningfallen in der Massenspektrometrie hat zu einem einmaligen Genauigkeitssprung geführt. Dadurch wurden Massenwerte verschiedenster Atome zu wichtigen Eingangsparametern bei immer mehr physikalischen Fragestellungen. Die Massenspektrometrie mit Hilfe von Penningfallen basiert auf der Bestimmung der freien Zyklotronfrequenz eines Ions in einem homogenen Magnetfeld νc=qB/(2πm). Sie wird mit Flugzeitmethode (TOF-ICR) bestimmt, wobei eine relative Massenungenauigkeit δm/m von wenigen 10^-9 bei Nukliden mit Lebensdauern von <500 ms erreicht wird. Dies wurde durch die im Rahmen dieser Arbeit erstmals in der Penningfallen-Massenspektrometrie eingesetzten Ramsey-Methode möglich. Dabei werden zeitlich separierte, oszillierenden Feldern zur resonanten Ionenanregung genutzt, um die Frequenzmessung durch die Flugzeitmethode zu verbessern. Damit wurden am Penningfallenmassenspektrometer ISOLTRAP an ISOLDE/CERN die Massen der Nuklide 26,27Al und 38,39Ca bestimmt. Alle Massen wurden in die „Atomic Mass Evaluation“ eingebettet. Die Massenwerte von 26Al und 38Ca dienten insbesondere zu Tests des Standardmodells. Um mit Massenwerten fundamentale Symmetrien oder die Quantenelektrodynamik (QED) in extremen Feldern zu testen wurde ein neues Penningfallenprojekt (PENTATRAP) für hochpräzise Massenmessungen an hochgeladenen Ionen konzipiert. In dieser Doktorarbeit wurde vornehmlich die Entwicklung der Penningfallen betrieben. Eine Neuerung bei Penningfallenexperimenten ist dabei die permanente Beobachtung des Magnetfeldes B und seiner zeitlichen Fluktuationen durch so genannte „Monitorfallen“.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Die Bor-Neuroneneinfang-Therapie (engl.: Boron Neutron Capture Therapy, BNCT) ist eine indirekte Strahlentherapie, welche durch die gezielte Freisetzung von dicht ionisierender Strahlung Tumorzellen zerstört. Die freigesetzten Ionen sind Spaltfragmente einer Kernreaktion, bei welcher das Isotop 10B ein niederenergetisches (thermisches) Neutron einfängt. Das 10B wird durch ein spezielles Borpräparat in den Tumorzellen angereichert, welches selbst nicht radioaktiv ist. rnAn der Johannes Gutenberg-Universität Mainz wurde die Forschung für die Anwendung eines klinischen Behandlungsprotokolls durch zwei Heilversuche bei Patienten mit kolorektalen Lebermetastasen an der Universität Pavia, Italien, angeregt, bei denen die Leber außerhalb des Körpers in einem Forschungsreaktor bestrahlt wurde. Als erster Schritt wurde in Kooperation verschiedener universitärer Institute eine klinische Studie zur Bestimmung klinisch relevanter Parameter wie der Borverteilung in verschiedenen Geweben und dem pharmakokinetischen Aufnahmeverhalten des Borpräparates initiiert.rnDie Borkonzentration in den Gewebeproben wurde hinsichtlich ihrer räumlichen Verteilung in verschiedenen Zellarealen bestimmt, um mehr über das Aufnahmeverhalten der Zellen für das BPA im Hinblick auf ihre biologischen Charakteristika zu erfahren. Die Borbestimung wurde per Quantitative Neutron Capture Radiography, Prompt Gamma Activation Analysis und Inductively Coupled Plasma Mass Spectroscopy parallel zur histologischen Analyse des Gewebes durchgeführt. Es war möglich zu zeigen, dass in Proben aus Tumorgewebe und aus tumorfreiem Gewebe mit unterschiedlichen morphologischen Eigenschaften eine sehr heterogene Borverteilung vorliegt. Die Ergebnisse der Blutproben werden für die Erstellung eines pharmakokinetischen Modells verwendet und sind in Übereinstimmung mit existierenden pharmakokinetische Modellen. Zusätzlich wurden die Methoden zur Borbestimmung über speziell hergestellte Referenzstandards untereinander verglichen. Dabei wurde eine gute Übereinstimmung der Ergebnisse festgestellt, ferner wurde für alle biologischen Proben Standardanalyseprotokolle erstellt.rnDie bisher erhaltenen Ergebnisse der klinischen Studie sind vielversprechend, lassen aber noch keine endgültigen Schlussfolgerungen hinsichtlich der Wirksamkeit von BNCT für maligne Lebererkrankungen zu. rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The most important property controlling the physicochemical behaviour of polyelectrolytes and their applicability in different fields is the charge density on the macromolecular chain. A polyelectrolyte molecule in solution may have an effective charge density which is smaller than the actual charge density determined from its chemical structure. In the present work an attempt has been made to quantitatively determine this effective charge density of a model polyelectrolyte by using light scattering techniques. Flexible linear polyelectrolytes with a Poly(2-Vinylpyridine) (2-PVP) backbone are used in the present study. The polyelectrolytes are synthesized by quaternizing the pyridine groups of 2-PVP by ethyl bromide to different quaternization degrees. The effect of the molar mass, degree of quaternization and solvent polarity on the effective charge is studied. The results show that the effective charge does not vary much with the polymer molar mass or the degree of quaternization. But a significant increase in the effective charge is observed when the solvent polarity is increased. The results do not obey the counterion condensation theory proposed by Manning. Based on the very low effective charges determined in this study, a new mechanism for the counterion condensation phenomena from a specific polyelectrolyte-counterion interaction is proposed

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis work aims to develop original analytical methods for the determination of drugs with a potential for abuse, for the analysis of substances used in the pharmacological treatment of drug addiction in biological samples and for the monitoring of potentially toxic compounds added to street drugs. In fact reliable analytical techniques can play an important role in this setting. They can be employed to reveal drug intake, allowing the identification of drug users and to assess drug blood levels, assisting physicians in the management of the treatment. Pharmacological therapy needs to be carefully monitored indeed in order to optimize the dose scheduling according to the specific needs of the patient and to discourage improper use of the medication. In particular, different methods have been developed for the detection of gamma-hydroxybutiric acid (GHB), prescribed for the treatment of alcohol addiction, of glucocorticoids, one of the most abused pharmaceutical class to enhance sport performance and of adulterants, pharmacologically active compounds added to illicit drugs for recreational purposes. All the presented methods are based on capillary electrophoresis (CE) and high performance liquid chromatography (HPLC) coupled to various detectors (diode array detector, mass spectrometer). Biological samples pre-treatment was carried out using different extraction techniques, liquid-liquid extraction (LLE) and solid phase extraction (SPE). Different matrices have been considered: human plasma, dried blood spots, human urine, simulated street drugs. These developed analytical methods are individually described and discussed in this thesis work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eisbohrkerne stellen wertvolle Klimaarchive dar, da sie atmosphärisches Aerosol konservieren. Die Analyse chemischer Verbindungen als Bestandteil atmosphärischer Aerosole in Eisbohrkernen liefert wichtige Informationen über Umweltbedingungen und Klima der Vergangenheit. Zur Untersuchung der α-Dicarbonyle Glyoxal und Methylglyoxal in Eis- und Schneeproben wurde eine neue, sensitive Methode entwickelt, die die Stir Bar Sorptive Extraction (SBSE) mit der Hochleistungsflüssigchromatographie-Massenspektrometrie (HPLC-MS) kombiniert. Zur Analyse von Dicarbonsäuren in Eisbohrkernen wurde eine weitere Methode entwickelt, bei der die Festphasenextraktion mit starkem Anionenaustauscher zum Einsatz kommt. Die Methode erlaubt die Quantifizierung aliphatischer Dicarbonsäuren (≥ C6), einschließlich Pinsäure, sowie aromatischer Carbonsäuren (wie Phthalsäure und Vanillinsäure), wodurch die Bestimmung wichtiger Markerverbindungen für biogene und anthropogene Quellen ermöglicht wurde. Mit Hilfe der entwickelten Methoden wurde ein Eisbohrkern aus den Schweizer Alpen analysiert. Die ermittelten Konzentrationsverläufe der Analyten umfassen die Zeitspanne von 1942 bis 1993. Mittels einer Korrelations- und Hauptkomponentenanalyse konnte gezeigt werden, dass die organischen Verbindungen im Eis hauptsächlich durch Waldbrände und durch vom Menschen verursachte Schadstoffemissionen beeinflusst werden. Im Gegensatz dazu sind die Konzentrationsverläufe einiger Analyten auf den Mineralstaubtransport auf den Gletscher zurückzuführen. Zusätzlich wurde ein Screening der Eisbohrkernproben mittels ultrahochauflösender Massenspektrometrie durchgeführt. Zum ersten Mal wurden in diesem Rahmen auch Organosulfate und Nitrooxyorganosulfate in einem Eisbohrkern identifiziert.