1000 resultados para mash-up
Resumo:
Tm3+/Yb3+-codoped gernianate-niobic (GN) and germanium-bismuth (GB) glasses have been synthesized by conventional ruching and quenching method. Intense blue and weak red emissions centered at 477 and 650 nm, corresponding to the transitions (1)G(4)->H-3(6) and (1)G(4)->H-3(4), respectively, were observed at room temperature. The possible Up-conversion mechanisms are discussed and estimated. GN glass showed a weaker up-conversion emission than GB glass, which is inconsistent with the prediction from the difference of maximum phonon energy between GN and GB glasses. In this paper, Raman spectroscopy was employed to investigate the origin of the difference in up-conversion luminescence in the two glasses. Compared with phonon side-band spectroscopy, Raman spectroscopy extracts more information including both phonon energy and phonon density. For the first time, our results reveal that, besides the maximum phonon energy, the phonon density of host glasses is also an important factor in determining the up-conversion efficiency. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Tm3+-doped oxide-chloride germanate and tellurite glasses have been synthesized by conventional melting method. Intense up-conversion luminescence emissions were simultaneously observed at room temperature in these glasses. The possible up-conversion mechanisms are discussed and estimated. However, in these Tm3+-doped glasses, tellurite glass showed weaker up-conversion emissions than germanate glass, which is inconsistent with the prediction from the difference of maximum phonon energy between tellurite and germanate glasses. In this paper, Raman spectroscopy was employed to investigate the origin of the difference in up-conversion luminescence in the two glasses. Our results confirm that, besides the maximum phonon energy, the phonon density of host glasses is also an important factor in determining the up-conversion efficiency. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Ytterbium-sensitized erbium-doped oxide-halide tellurite and germanate-niobic-lead glasses have been synthesized by conventional melting method. Intense green and red emissions centered at 525, 546 and 657 nm, corresponding to the transitions H-2(11/2) -> I-4(15/2), S-4(3/2) -> I-4(15/2) and F-4(9/2) -> I-4(15/2), respectively, were simultaneously observed at room temperature in these glasses. The quadratic dependence of the 525, 546 and 657 nm emissions on excitation power indicates that a two-photon absorption process occurs. Tellurite glass showed a weaker up-conversion emission than germanate-niobic-lead glass, which is inconsistent with the prediction from the difference of maximum phonon energy between tellurite and germanate-mobic-lead glasses. In this paper, Raman spectroscopy was employed to investigate the origin of the difference in up-conversion luminescence in the two glasses. Compared with phonon side-band spectroscopy, Raman spectroscopy extracts more information including both phonon energy and phonon density. Our results reveal that the phonon density and the maximum phonon energy of host glasses are both important factors in determining the up-conversion efficiency. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Up-converting phosphor technology (UPT)-based lateral-flow immunoassay has been developed for quantitative detection of Yersinia pestis rapidly and specifically. In this assay, 400 nm up-converting phosphor particles were used as the reporter. A sandwich immumoassay was employed by using a polyclonal antibody against F1 antigen of Y. pestis immobilized on the nitrocellulose membrane and the same antibody conjugated to the UPT particles. The signal detection of the strips was performed by the UPT-based biosensor that could provide a 980 nm IR laser to excite the phosphor particles, then collect the visible luminescence emitted by the UPT particles and finally convert it to the voltage as a signal. V-T and V-c stand for the multiplied voltage units for the test and the control line, respectively, and the ratio V-T/V-C is directly proportional to the number of Y pestis in a sample. We observed a good linearity between the ratio and log CFU/ml of Y pestis above the detection limit, which was approximately 10(4) CFU/mI. The precision of the intra- and inter-assay was below 15% (coefficient of variation, CV). Cross-reactivity with related Gram-negative enteric bacteria was not found. The UPT-LF immunoassay system presented here takes less than 30 min to perform from the sample treatment to the data analysis. The current paper includes only preliminary data concerning the biomedical aspects of the assay, but is more concentrated on the technical details of establishing a rapid manual assay using a state-of-the-art label chemistry. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
El proyecto consiste en un plan de empresa actualizado para la empresa Commercial Diving Activities, S.L . Es una empresa de obras y servicios integrales de buceo comercial que cuenta con una división dedicada a la formación de buceo profesional.
Resumo:
Aditu askoren arabera, milurteko berriaren atarian marketin filosofia berri bat hasi zen loratzen: Marketin Esperientziala. Filosofia berri horrek paradigma aldaketa bat suposatzen du, fokua bezeroek enpresekin bizi dituzten esperientzia gogoangarrietan jartzen duena. Gaur egun, produktu eta zerbitzuak geroz eta antzekoagoak dira, kalitate eta prezioan oinarritutako lehia ez da nahikoa eta bezeroa geroz eta zorrotzagoa da. Horrek guztiak desberdintzeko bide berriak bilatu beharra dakar eta, horregatik, produktu eta zerbitzuez gain esperientziak sortu eta eskaintzea aukera paregabea bilakatu da enpresentzat, hau da, faktore emozionala kontuan hartzea. Gradu Amaierako Lan honek filosofia berri horren nondik norakoak aztertzea bilatzen du eta baita erosketa puntuan nola aplikatzen den ikertzea ere; izan ere, erosketa puntuek bezeroa, produktu/zerbitzua eta langileak atmosfera bakar batean biltzen dituzte. Horretarako, erosketa puntuan parte-hartzen duten esperientzia-eragile nagusiak aztertuko dira: zentzumenak, estetika eta diseinua eta langileen portaera. Ondoren, adibide gisa kasu praktiko eta esanguratsu bat aztertuko da: Pop Up Storeak edo, beste era batera esanda, aldi baterako establezimenduak.
Resumo:
The up-conversion luminescence of Yb3+-doped yttriurn lanthanum oxide transparent ceramic was investigated. It was ascribed to cooperative luminescence originated from the coupled states of the Yb3+ ion pairs. The proper doping of La2O3 can remove the cooperative luminescence of Yb3+ ion. But excessive La2O3 (at least 10 at.%) the cooperative up-conversion of Yb3+:Y2O3 is obtained again, and the intensity of up-conversion luminescence strengthens with the increase of La2O3 content. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Pop-up satellite archival tags (PSATs) have been used to study movements, habitat use, and postrelease survival of large pelagic vertebrates, but the size of these tags has historically precluded their use on smaller coastal species. To evaluate a new generation of smaller PSATs for the study of postrelease survival and habitat use of coastal species, we attached Microwave Telemetry, Inc., X-tags to ten striped bass (Morone saxatilis) 94–112 cm total length (TL) caught on J hooks and circle hooks during the winter recreational fishery in Virginia. Tags collected temperature and depth information every five minutes and detached from the fish after 30 days. Nine of the ten tags released on schedule and eight transmitted 30% to 96% (mean 78.6%) of the archived data. Three tags were physically recovered during or after the transmission period, allowing retrieval of all archived data. All eight striped bass whose tags transmitted data survived for 30 days after release, including two fish that were hooked deeply with J hooks. The eight fish spent more than 90% of their time at depths less than 10 m and in temperatures of 6–9°C, demonstrated no significant diel differences in depth or temperature utilization (P>0.05), and exhibited weak periodicities in vertical movements consistent with daily and tidal cycles.