692 resultados para hexagonal ferrites


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we obtain nickel ferrite by the combustion synthesis method whcih involves synthesising in an oven at temperatures of 750oC, 950oC and 125oC. The precursors oxidizing used were nickel nitrate, ferric as an oxidizing and reducing urea (fuel). After obtaining the mixture, the product was deagglomerated and past through a 270 mesh sieve. To assess the structure, morphology, particle size, magnetic and electrical properties of nanoparticles obtained the samples were sintered and characterized by x-ray distraction (XRD), x-ray fluorescence spectroscopy (FRX); scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), vibrating sample magnetometer (MAV ) and electrical permittivity. The results indicated the majority of phase inverse spinel ferrite and Hematite secondary phase nickel and nickel oxide. Through the intensity of the distraction, the average size of the crystallization peaks were half-height width which was calculated using the Scherrer equation. From observing the peaks of all the reflections, it appears that samples are crystal clear with the formation of nanoparticles. Morphologically, the nanoferritas sintered nickel pellet formation was observed with three systems of particle size below 100mn, which favored the formation of soft pellets. The average size of the grains in their micrometric scale. FRX and EDS showed qualitatively the presence of iron elements nickel and oxygen, where through quantitative data we can observe the presence of the secondary phase. The magnetic properties and the saturation magnetization and the coercive field are in accordance with the nickel, ferrite where the curve of hysteresis has aspects of a soft material. Dielectric constant values are below 10 and low tangent loss

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Observar os efeitos da aplicação tópica de 5-fluorouracil (5-FU) sobre o epitélio corneano íntegro. MÉTODOS: Foram utilizados 10 coelhos albinos (14 olhos), divididos em: grupo controle (GC), 4 olhos nos quais não se administraram drogas, grupo 1 (G1), 5 olhos que receberam 5-fluorouracil na concentração 1,25% e grupo 2 (G2), 5 olhos que receberam 5-fluorouracil na concentração de 2,5%. A droga foi instilada 4 vezes por dia, durante 7 dias, quando os animais foram sacrificados, os olhos removidos, separando-se a córnea que foi preparada de modo convencional para estudo em microscópico eletrônico de varredura. RESULTADOS: GC: observaram-se células de formato hexagonal, claras, escuras e intermediárias, compondo o epitélio corneano de coelhos. Presença de numerosas microplicas, principalmente nas células claras. Cada célula possui cerca de 1 a 3 criptas. Nos animais do G1, observou-se maior número de células escuras, regiões com diminuição no número de criptas; alterações da superfície celular, protusão na região do núcleo e descamação de células epiteliais. Os do G2 tiveram aumento de microprojeções na superfície celular, modificações nas junções intercelulares até separação de células adjacentes; diminuição do número e variabilidade no tamanho das criptas. As alterações mais freqüentes ocorreram nas células da periferia da córnea. CONCLUSÃO: O 5-fluorouracil teve efeitos deletérios no epitélio íntegro corneano de coelhos. As alterações observadas foram mais importantes nos animais que receberam a droga mais concentrada (G2) e mais freqüentes na periferia da córnea.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate, using three-dimensional finite element analysis (3D FEA), the stress distribution in peri-implant bone tissue, implants, and prosthetic components of implant-supported single crowns with the use of the platform-switching concept. Materials and Methods: Three 3D finite element models were created to replicate an external-hexagonal implant system with peri-implant bone tissue in which three different implant-abutment configurations were represented. In the regular platform (RP) group, a regular 4.1-mm-diameter abutment (UCLA) was connected to regular 4.1-mm-diameter implant. The platform-switching (PS) group was simulated by the connection of a wide implant (5.0 mm diameter) to a regular 4.1-mm-diameter UCLA abutment. In the wide-platform (WP) group, a 5.0-mm-diameter UCLA abutment was connected to a 5.0-mm-diameter implant. An occlusal load of 100 N was applied either axially or obliquely on the models using ANSYS software. Results: Both the increase in implant diameter and the use of platform switching played roles in stress reduction. The PS group presented lower stress values than the RP and WP groups for bone and implant. In the peri-implant area, cortical bone exhibited a higher stress concentration than the trabecular bone in all models and both loading situations. Under oblique loading, higher intensity and greater distribution of stress were observed than under axial loading. Platform switching reduced von Mises (17.5% and 9.3% for axial and oblique loads, respectively), minimum (compressive) (19.4% for axial load and 21.9% for oblique load), and maximum (tensile) principal stress values (46.6% for axial load and 26.7% for oblique load) in the peri-implant bone tissue. Conclusion: Platform switching led to improved biomechanical stress distribution in peri-implant bone tissue. Oblique loads resulted in higher stress concentrations than axial loads for all models. Wide-diameter implants had a large influence in reducing stress values in the implant system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:482-491

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of unilateral misfit at different levels on a crown-implant-retention screw system of implant-supported crowns. Hexagon castable UCLA abutments were cast in Co-Cr alloy to fabricate 48 metallic crowns divided into four groups (n = 12). Group A: crowns did not present misfit; Groups B, C and D: crowns were fabricated with unilateral misfit of 50, 100, and 200 mu m, respectively. The crowns were attached by titanium retention screw with 30 N/cm to external hexagonal osseointegrated implants embedded in acrylic resin. After 2 min, the retention screw of each replica was submitted to detorque evaluation by an analogic torque gauge. Three retention screws were used to perform detorque evaluation at each replica and the procedure was repeated twice with each screw. Each group was submitted to 72 detorque measurements. Data were evaluated by ANOVA and Tukey test (P < 0.05). All groups exhibited significant decrease (P < 0.05) in preload and the lowest decrease occurred in Group A. Groups B, C, and D were statistically significant different from Group A (P < 0.05), but there was no statistically significant difference between Groups B and D (P > 0.05). Crowns with unilateral misfit presented higher preload decrease than crowns completely fitted to osseointegrated implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Crotoxin, a potent neurotoxin from the venom of the South American rattlesnake Crotalus durissus terrificus, exists as a heterodimer formed between a phospholipase A(2) and a catalytically inactive acidic phospholipase A(2) analogue (crotapotin). Large single crystals of the crotoxin complex and of the isolated subunits have been obtained. The crotoxin complex crystal belongs to the orthorhombic space group P2(1)2(1)2, with unit-cell parameters a = 38.2, b = 68.7, c = 84.2 angstrom, and diffracted to 1.75 angstrom resolution. The crystal of the phospholipase A(2) domain belongs to the hexagonal space group P6(1)22 (or its enantiomorph P6(5)22), with unit-cell parameters a = b = 38.7, c = 286.7 angstrom, and diffracted to 2.6 angstrom resolution. The crotapotin crystal diffracted to 2.3 angstrom resolution; however, the highly diffuse diffraction pattern did not permit unambiguous assignment of the unit-cell parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SMase I, a 32 kDa sphingomyelinase found in Loxosceles laeta venom, is responsible for the major pathological effects of spider envenomation. This toxin has been cloned and functionally expressed as a fusion protein containing a 6 x His tag at its N-terminus to yield a 33 kDa protein [Fernandes-Pedrosa et al. (2002), Biochem. Biophys. Res. Commun. 298, 638 - 645]. The recombinant protein possesses all the biological properties ascribed to the whole L. laeta venom, including dermonecrotic and complement-dependent haemolytic activities. Dynamic light-scattering experiments conducted at 291 K demonstrate that the sample possesses a monomodal distribution, with a hydrodynamic radius of 3.57 nm. L. laeta SMase I was crystallized by the hanging-drop vapour-diffusion technique using the sparse-matrix method. Single crystals were obtained using a buffer solution consisting of 0.08 M HEPES and 0.9 M trisodium citrate, which was titrated to pH 7.5 using 0.25 M sodium hydroxide. Complete three-dimensional diffraction data were collected to 1.8 Angstrom at the Laboratorio Nacional de Luz Sincrotron (LNLS, Campinas, Brazil). The crystals belong to the hexagonal system ( space group P6(1) or P6(5)), with unit-cell parameters a = b = 140.6, c = 113.6 Angstrom. A search for heavy-atom derivatives has been initiated and elucidation of the crystal structure is currently in progress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foram estudados 20 olhos de 10 cães sem raça definida, machos e fêmeas com 6 anos de idade. A morfologia das células do endotélio da córnea foi analisada utilizando-se microscópio especular de contato. Foram estudadas as regiões central e periférica da córnea. de cada região da córnea foram realizadas três micrografias. de cada micrografia foram analisadas no mínimo 100 células endoteliais. Foram obtidos os valores do polimegatismo e pleomorfismo. O endotélio corneano de cães caracterizou-se por uma monocamada de células poligonais uniformes em tamanho e forma. A forma predominante das células endoteliais foi hexagonal. O índice de polimegatismo foi 0.22. Este estudo demonstrou que a morfologia das células do endotélio da córnea de cães é semelhante à observada em humanos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivou-se examinar a superfície posterior do endotélio corneano e realizar análise morfométrica das células endoteliais da córnea de avestruz (Struthio camelus) valendo-se da microscopia eletrônica de varredura. Avaliaram-se o número de lados, a área celular média, a densidade celular e o coeficiente de variação da área celular. O endotélio corneano de avestruz constitui-se de células poligonais uniformes em tamanho e forma, e com poucas interdigitações das bordas celulares. Visibilizaram-se microvilosidades na superfície celular. A área celular média foi de 269±18µm² e a densidade celular foi de 3717±240 células mm-2. O coeficiente de variação foi de 0,06 e o percentual de células hexagonais de 75%. Não foram observadas diferenças significativas entre os parâmetros avaliados entre os olhos esquerdo e direito. Este estudo demonstrou que o endotélio corneano de avestruz é semelhante ao descrito em outros vertebrados.