1000 resultados para free pulse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Article describing the design standards and their use for Paralympic facilities. This article was published in the book entitled Olympic Villages: a hundred years of urban planning and shared experiences compiling the papers given at the 1997 International Symposium on International Chair in Olympism (IOC-UAB).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Vegeu el resum a l'inici del document del fitxer adjunt."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Vegeu el resum a l'inici del document del fitxer adjunt."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serum-free aggregating cell cultures of fetal rat telencephalon were examined by a combined biochemical and double-labeling immunocytochemical study for the developmental expression of glial fibrillary acidic protein (GFAP) and glutamine synthetase (GS). It was found that these two astroglial markers are co-expressed at different developmental stages in vitro. During the phase of cellular maturation (i.e. between days 14 and 34), GFAP levels and GS activity increase rapidly and in parallel. At the same time, the number of immunoreactive cells increase while the long and thick processes staining in early cultures gradually disappear. The present results demonstrate that in this particular cell culture system only one type of astrocytes develops which expresses both GFAP and GS and which attains a relatively high degree of maturation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Auditory spatial functions, including the ability to discriminate between the positions of nearby sound sources, are subserved by a large temporo-parieto-frontal network. With the aim of determining whether and when the parietal contribution is critical for auditory spatial discrimination, we applied single pulse transcranial magnetic stimulation on the right parietal cortex 20, 80, 90 and 150 ms post-stimulus onset while participants completed a two-alternative forced choice auditory spatial discrimination task in the left or right hemispace. Our results reveal that transient TMS disruption of right parietal activity impairs spatial discrimination when applied at 20 ms post-stimulus onset for sounds presented in the left (controlateral) hemispace and at 80 ms for sounds presented in the right hemispace. We interpret our finding in terms of a critical role for controlateral temporo-parietal cortices over initial stages of the building-up of auditory spatial representation and for a right hemispheric specialization in integrating the whole auditory space over subsequent, higher-order processing stages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider a population of agents distributed on the unit interval. Agents form jurisdictions in order to provide a public facility and share its costs equally. This creates an incentive to form large entities. Individuals also incur a transportation cost depending on their location and that of the facility which makes small jurisdictions advantageous. We consider a fairly general class of distributions of agents and generalize previous versions of this model by allowing for non-linear transportation costs. We show that, in general, jurisdictions are not necessarily homogeneous. However, they are if facilities are always intraterritory and transportation costs are superadditive. Superadditivity can be weakened to strictly increasing and strictly concave when agents are uniformly distributed. Keywords: Consecutiveness, stratification, local public goods, coalition formation, country formation. JEL Classification: C71 (Cooperative Games), D71 (Social Choice; Clubs; Committees; Associations), H73 (Interjurisdictional Differentials and Their Effects).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To test the accuracy of a new pulse oximeter sensor based on transmittance and reflectance. This sensor makes transillumination of tissue unnecessary and allows measurements on the hand, forearm, foot, and lower limb. DESIGN: Prospective, open, nonrandomized criterion standard study. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 54 critically ill neonates (gestational age 27 to 42 wks; postnatal age 1 to 28 days) with arterial catheters in place. MEASUREMENTS AND MAIN RESULTS: A total of 99 comparisons between pulse oximetry and arterial saturation were obtained. Comparison of femoral or umbilical arterial blood with transcutaneous measurements on the lower limb (n = 66) demonstrated an excellent correlation (r2 = .96). The mean difference was +1.44% +/- 3.51 (SD) % (range -11% to +8%). Comparison of the transcutaneous values with the radial artery saturation from the corresponding upper limb (n = 33) revealed a correlation coefficient of 0.94 with a mean error of +0.66% +/- 3.34% (range -6% to +7%). The mean difference between noninvasive and invasive measurements was least with the test sensor on the hand, intermediate on the calf and arm, and greatest on the foot. The mean error and its standard deviation were slightly larger for arterial saturation values < 90% than for values > or = 90%. CONCLUSION: Accurate pulse oximetry saturation can be acquired from the hand, forearm, foot, and calf of critically ill newborns using this new sensor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Vegeu el resum a l'inici del document del fitxer adjunt."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyses intergenerational earnings mobility in Spain correcting for different selection biases. We address the co-residence selection problem by combining information from two samples and using the two-sample two-stage least square estimator. We find a small decrease in elasticity when we move to younger cohorts. Furthermore, we find a higher correlation in the case of daughters than in the case of sons; however, when we consider the employment selection in the case of daughters, by adopting a Heckman-type correction method, the diference between sons and daughters disappears. By decomposing the sources of earnings elasticity across generations, we find that the correlation between child's and father's occupation is the most important component. Finally, quantile regressions estimates show that the influence of the father's earnings is greater when we move to the lower tail of the offspring's earnings distribution, especially in the case of daughters' earnings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free amino acids (AAs) in human plasma are derivatized with 3-(4-carboxybenzoyl)quinoline-2-carboxaldehyde (CBQCA) and analyzed by capillary electrophoresis (CE) with laser induced fluorescence (LIF) detection. The labeling procedure is significantly improved over results reported previously. Derivatization can be completed in 40 min, with concentrations as low as 4 x 10(-8) M successfully labeled in favourable cases. Twenty-nine AAs (including 2 internal standards) are identified and can be reproducibly separated in 70 min. Migration time RSD values for 23 of these AAs were calculated and found in the range from 0.5 to 4%. The rapid derivatization procedure and the resolution obtained in the separation are sufficient for a semi-quantitative, emergency diagnosis of several inborn errors of metabolism (IEM). Amino acid profiles for both normal donor plasma samples and plasma samples of patients suffering from phenylketonuria, tyrosinemia, maple syrup urinary disease, hyperornithinemia, and citrullinemia are studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Reconstruction of the central aortic pressure wave from the noninvasive recording of the radial pulse with applanation tonometry has become a standard tool in the field of hypertension. It is not presently known whether recording the radial pulse on the dominant or the nondominant side has any effect on such reconstruction. METHOD: We carried out radial applanation tonometry on both forearms in young, healthy, male volunteers, who were either sedentary (n = 11) or high-level tennis players (n = 10). The purpose of including tennis players was to investigate individuals with extreme asymmetry between the dominant and nondominant upper limb. RESULTS: In the sedentary individuals, forearm circumference and handgrip strength were slightly larger on the dominant (mean +/- SD respectively 27.9 +/- 1.5 cm and 53.8 +/- 10 kg) than on nondominant side (27.3 +/- 1.6 cm, P < 0.001 vs. dominant, and 52.1 +/- 11 kg, P = NS). In the tennis players, differences between sides were more conspicuous (forearm circumference: dominant 28.0 +/- 1.7 cm nondominant 26.4 +/- 1.5 cm, P < 0.001; handgrip strength 61.4 +/- 10.8 vs. 53.4 +/- 9.7 kg, P < 0.001). We found that in both sedentary individuals and tennis players, the radial pulse had identical shape on both sides and, consequently, the reconstructed central aortic pressure waveforms, as well as derived indices of central pulsatility, were not dependent on the side where applanation tonometry was carried out. CONCLUSION: Evidence from individuals with maximal asymmetry of dominant vs. nondominant upper limb indicates that laterality of measurement is not a methodological issue for central pulse wave analysis carried out with radial applanation tonometry.