902 resultados para distribution system operator
Resumo:
This paper analyzes the factors associated with the rejection of products at ports of importer countries and remedial actions taken by producers in China by taking as an example one of the most competitive agro-food products of China: frozen vegetables. This paper provides an overview of the vegetable production and distribution system in China and the way in which China has been participating in exports of these products. Later sections will examine in detail the frozen vegetable sector in China, identify the causes of port rejections, and the actions taken by the Chinese government and by producers, processors and exporters to improve the quality of frozen vegetable exports.
Resumo:
This paper discusses globalization’s impact on production and distribution systems in emerging economies. On one hand, globalization has resulted in an increasing number of multinational corporations to adopt a platform strategy for their customers in emerging markets. On the other hand, developing countries have witnessed the integration of an increasing number of traditional marketplaces into a powerful distribution system, characterized as a specialized market system. Consequently, an unique industrial organization has developed in emerging economies, regarded as emerging global value chains (EGVCs). They comprise a large number of small firms together with a small number of large platform providers and display the "market" type general governance patterns. Firms in EGVCs are more likely to realize functional upgrading and grow into strong lead firms.
Resumo:
In this paper, the dynamic response of a hydro power plant for providing secondary regulation reserve is studied in detail. Special emphasis is given to the elastic water column effects both in the penstock and the tailrace tunnel. For this purpose, a nonlinear model based on the analogy between mass and momentum conservation equations of a water conduit and those of wave propagation in transmission lines is used. The influence of the plant configuration and design parameters on the fulfilment of the Spanish Electrical System Operator requirements is analysed
Resumo:
Communications Based Train Control Systems require high quality radio data communications for train signaling and control. Actually most of these systems use 2.4GHz band with proprietary radio transceivers and leaky feeder as distribution system. All them demand a high QoS radio network to improve the efficiency of railway networks. We present narrow band, broad band and data correlated measurements taken in Madrid underground with a transmission system at 2.4 GHz in a test network of 2 km length in subway tunnels. The architecture proposed has a strong overlap in between cells to improve reliability and QoS. The radio planning of the network is carefully described and modeled with narrow band and broadband measurements and statistics. The result is a network with 99.7% of packets transmitted correctly and average propagation delay of 20ms. These results fulfill the specifications QoS of CBTC systems.
Resumo:
Un incremento de la demanda del agua, junto con el aumento de la contaminación, ha provocado que hoy en día la reutilización de las aguas depuradas sea necesaria, pero la reutilización de aguas debe garantizar y minimizar los posibles riesgos sanitarios y medioambientales que su práctica pueda provocar. En España estos parámetros se encuentran regulados por el RD 1620/2007 relativo al régimen jurídico de la reutilización de las aguas depuradas. Las aguas regeneradas son aguas que ya han sido sometidas a un tratamiento de depuración, y a las cuales se aplica un posterior tratamiento adicional o complementario que permita adecuar su calidad al uso al que vaya a destinarse. Siendo requeridos para los distintos reúsos procesos de desinfección, uno de los principales sistemas utilizados es el cloro, debido a su sencilla aplicación y costos bajos, sin tomar en cuenta la posible formación de compuestos organohalogenados potencialmente cancerígenos. Es por esto que surge la necesidad de aplicar distintos sistemas de oxidación objeto de estudio en esta tesis, como el dióxido de cloro estabilizado, ozono y los procesos avanzados de oxidación (Advanced Oxidation Processes, AOP), ozono/peróxido y uv/peróxido. En esta tesis se investiga los rendimientos que pueden alcanzar estos sistemas en la eliminación de los ácidos húmicos y los fenoles, siendo las principales sustancias formadoras de subproductos de la desinfección, así mismo, se considera necesario garantizar la desinfección del agua a través del estudio de tres grupos de microrganismos, los coliformes totales, e. coli y enterococos, siendo un punto importante el posible recrecimiento microbiológico debido a una desinfección escasa, por la permanencia en el agua de los compuestos antes mencionados, o por alguna fuente de alimento que pudieran encontrar en el sistema de distribución. Lo más importante será la calidad que se pueda alcanzar con estos desinfectantes, con el fin de obtener agua para los distintos reúsos que existen en la actualidad. Y así no limitar los alcances que puede tener la reutilización de las aguas residuales. Basándose en lo antes mencionado se procedió a realizar la caracterización del agua del rio Manzanares, con el fin de determinar la cantidad de ácidos húmicos disueltos y fenoles, obteniendo valores bajos, se decidió incorporar a las muestras de rio 5 mg/L de estos compuestos, con el fin de observar de que manera podrían interferir en la desinfección de esta agua. De esta forma se logran obtener resultados óptimos de los sistemas de desinfección estudiados, siendo el Ozono un oxidante eficiente en la desinfección de los microrganismos y en la eliminación de ácidos húmicos y fenoles con tiempos de contacto cortos, mostrando deficiencias al permitir el recrecimiento de los coliformes totales. Del sistema de oxidación avanzada UV/Peróxido se determino como un eficiente desinfectante para garantizar la inexistencia de rebrotes, al paso del tiempo. Así mismo se concluye que tiene buenos rendimientos en la eliminación del ácido húmico y los fenoles. An increase in water demand, coupled with increasing pollution, has caused today reuse of treated water is necessary, but must ensure water reuse and minimize potential health and environmental risks that their practice is cause. In Spain these parameters are regulated by Royal Decree 1620/2007 on the legal regime of the reuse of treated water. The reclaimed water is water that has already been subjected to a depuration treatment, which is applied as a subsequent further treatment that will bring quality to the use to which is to be delivered. As required for various reuses disinfection processes, one of the main systems used is chlorine, due to its simple implementation and low costs, without taking into account the possible formation of potentially carcinogenic halogenated organic compounds. That is why there is a need to apply different oxidation systems studied in this thesis, as stabilized chlorine dioxide, ozone and advanced oxidation processes (AOP), ozone/peroxide and UV/peroxide. This thesis investigates the rates can reach these systems in removing humic acids and phenols, the main substances forming disinfection byproducts, likewise, it is considered necessary to ensure water disinfection through the study of three groups of microorganisms, total coliform, e. coli and enterococci, the important point being a possible regrowth due to microbiological disinfection scarce, the water remaining on the aforementioned compounds, or a food source which may be found in the distribution system. The most important quality is that achievable with these disinfectants, with the water to obtain various reuses that exist today. And thus not limit the scope that can be reuse of wastewater. Based on the above we proceeded to perform characterization Manzanares river water, in order to determine the quantity of dissolved humic acids and phenols, obtaining low values, it was decided to incorporate river samples 5 mg / L of these compounds, in order to observe how they might interfere with the disinfection of the water. Thus optimum results are achieved for disinfection systems studied, being efficient ozone oxidant in the disinfection of microorganisms and the removal of humic acids and phenols with short contact times, showing gaps to allow regrowth total coliforms. Advanced oxidation system UV / peroxide were determined as an efficient disinfectant to ensure the absence of volunteers, the passage of time. Also it is concluded that has good yields in removing humic acid and phenols.
Resumo:
In this paper, the dynamic response of a hydro power plant for providing secondary regulation reserve is studied in detail. S pecial emphasis is given to the elastic water column effects both in the penstock and the tailrace tunnel. For this purpose, a nonline ar model based on the analogy between mass and momentum conservation equations of a water conduit and those of wave propagation in transmission lines is used. The influence of the plant configuration and design parameters on the fulfilment of the Spanish Electrical System Operator requirem ents is analysed.
Resumo:
The ESS-Bilbao facility, hosted by the University of the Basque Country (UPV/EHU), envisages the operation of a high-current proton accelerator delivering beams with energies up to 50 MeV. The time-averaged proton current will be 2.25 mA, delivered by 1.5 ms proton pulses with a repetition rate of 20 Hz. This beam will feed a neutron source based upon the Be (p,n) reaction, which will enable the provision of relevant neutron experimentation capabilities. The neutron source baseline concept consists in a rotating beryllium target cooled by water. The target structure will comprise a rotatable disk made of 6061-T6 aluminium alloy holding 20 beryllium plates. Heat dissipation from the target relies upon a distribution of coolant-flow channels. The practical implementation of such a concept is here described with emphasis put on the beryllium plates thermo-mechanical optimization, the chosen coolant distribution system as well as the mechanical behavior of the assembly.
Resumo:
The main objective of this paper is the development and application of multivariate time series models for forecasting aggregated wind power production in a country or region. Nowadays, in Spain, Denmark or Germany there is an increasing penetration of this kind of renewable energy, somehow to reduce energy dependence on the exterior, but always linked with the increaseand uncertainty affecting the prices of fossil fuels. The disposal of accurate predictions of wind power generation is a crucial task both for the System Operator as well as for all the agents of the Market. However, the vast majority of works rarely onsider forecasting horizons longer than 48 hours, although they are of interest for the system planning and operation. In this paper we use Dynamic Factor Analysis, adapting and modifying it conveniently, to reach our aim: the computation of accurate forecasts for the aggregated wind power production in a country for a forecasting horizon as long as possible, particularly up to 60 days (2 months). We illustrate this methodology and the results obtained for real data in the leading country in wind power production: Denmark
Resumo:
In this paper, a hydroelectric power plant with long tail-race tunnel has been modelled for assessing its contribution to secondary regulation reserve. Cavitation problems, caused by the discharge conduit length, are expected downstream the turbine where low pressure appears during regulation manoeuvres. Therefore, governor's gains should be selected taking into account these phenomena. On the other hand, regulation services bidden by the plant operator should fulfil TSO (Transmission System Operator) quality requirements. A methodology for tuning governor PI gains is proposed and applied to a Hydro power plant in pre-design phase in northwest area of Spain. The PI gains adjustment proposed provides a proper plant response, according to some established indexes, while avoiding cavitation phenomena.
Resumo:
The proton–sucrose symporter mediates the key transport step in the resource distribution system that allows many plants to function as multicellular organisms. In the results reported here, we identify sucrose as a signaling molecule in a previously undescribed signal-transduction pathway that regulates the symporter. Sucrose symporter activity declined in plasma membrane vesicles isolated from leaves fed exogenous sucrose via the xylem transpiration stream. Symporter activity dropped to 35–50% of water controls when the leaves were fed 100 mM sucrose and to 20–25% of controls with 250 mM sucrose. In contrast, alanine symporter and glucose transporter activities did not change in response to sucrose treatments. Decreased sucrose symporter activity was detectable after 8 h and reached a maximum by 24 h. Kinetic analysis of transport activity showed a decrease in Vmax. RNA gel blot analysis revealed a decrease in symporter message levels, suggesting a drop in transcriptional activity or a decrease in mRNA stability. Control experiments showed that these responses were not the result of changing osmotic conditions. Equal molar concentrations of hexoses did not elicit the response, and mannoheptulose, a hexokinase inhibitor, did not block the sucrose effect. These data are consistent with a sucrose-specific response pathway that is not mediated by hexokinase as the sugar sensor. Sucrose-dependent changes in the sucrose symporter were reversible, suggesting this sucrose-sensing pathway can modulate transport activity as a function of changing sucrose concentrations in the leaf. These results demonstrate the existence of a signaling pathway that can control assimilate partitioning at the level of phloem translocation.
Resumo:
O problema de Planejamento da Expansão de Sistemas de Distribuição (PESD) visa determinar diretrizes para a expansão da rede considerando a crescente demanda dos consumidores. Nesse contexto, as empresas distribuidoras de energia elétrica têm o papel de propor ações no sistema de distribuição com o intuito de adequar o fornecimento da energia aos padrões exigidos pelos órgãos reguladores. Tradicionalmente considera-se apenas a minimização do custo global de investimento de planos de expansão, negligenciando-se questões de confiabilidade e robustez do sistema. Como consequência, os planos de expansão obtidos levam o sistema de distribuição a configurações que são vulneráveis a elevados cortes de carga na ocorrência de contingências na rede. Este trabalho busca a elaboração de uma metodologia para inserir questões de confiabilidade e risco ao problema PESD tradicional, com o intuito de escolher planos de expansão que maximizem a robustez da rede e, consequentemente, atenuar os danos causados pelas contingências no sistema. Formulou-se um modelo multiobjetivo do problema PESD em que se minimizam dois objetivos: o custo global (que incorpora custo de investimento, custo de manutenção, custo de operação e custo de produção de energia) e o risco de implantação de planos de expansão. Para ambos os objetivos, são formulados modelos lineares inteiros mistos que são resolvidos utilizando o solver CPLEX através do software GAMS. Para administrar a busca por soluções ótimas, optou-se por programar em linguagem C++ dois Algoritmos Evolutivos: Non-dominated Sorting Genetic Algorithm-2 (NSGA2) e Strength Pareto Evolutionary Algorithm-2 (SPEA2). Esses algoritmos mostraram-se eficazes nessa busca, o que foi constatado através de simulações do planejamento da expansão de dois sistemas testes adaptados da literatura. O conjunto de soluções encontradas nas simulações contém planos de expansão com diferentes níveis de custo global e de risco de implantação, destacando a diversidade das soluções propostas. Algumas dessas topologias são ilustradas para se evidenciar suas diferenças.
Resumo:
This research proposes a methodology to improve computed individual prediction values provided by an existing regression model without having to change either its parameters or its architecture. In other words, we are interested in achieving more accurate results by adjusting the calculated regression prediction values, without modifying or rebuilding the original regression model. Our proposition is to adjust the regression prediction values using individual reliability estimates that indicate if a single regression prediction is likely to produce an error considered critical by the user of the regression. The proposed method was tested in three sets of experiments using three different types of data. The first set of experiments worked with synthetically produced data, the second with cross sectional data from the public data source UCI Machine Learning Repository and the third with time series data from ISO-NE (Independent System Operator in New England). The experiments with synthetic data were performed to verify how the method behaves in controlled situations. In this case, the outcomes of the experiments produced superior results with respect to predictions improvement for artificially produced cleaner datasets with progressive worsening with the addition of increased random elements. The experiments with real data extracted from UCI and ISO-NE were done to investigate the applicability of the methodology in the real world. The proposed method was able to improve regression prediction values by about 95% of the experiments with real data.
Resumo:
Os smart grids representam a nova geração dos sistemas elétricos de potência, combinando avanços em computação, sistemas de comunicação, processos distribuídos e inteligência artificial para prover novas funcionalidades quanto ao acompanhamento em tempo real da demanda e do consumo de energia elétrica, gerenciamento em larga escala de geradores distribuídos, entre outras, a partir de um sistema de controle distribuído sobre a rede elétrica. Esta estrutura modifica profundamente a maneira como se realiza o planejamento e a operação de sistemas elétricos nos dias de hoje, em especial os de distribuição, e há interessantes possibilidades de pesquisa e desenvolvimento possibilitada pela busca da implementação destas funcionalidades. Com esse cenário em vista, o presente trabalho utiliza uma abordagem baseada no uso de sistemas multiagentes para simular esse tipo de sistema de distribuição de energia elétrica, considerando opções de controle distintas. A utilização da tecnologia de sistemas multiagentes para a simulação é baseada na conceituação de smart grids como um sistema distribuído, algo também realizado nesse trabalho. Para validar a proposta, foram simuladas três funcionalidades esperadas dessas redes elétricas: classificação de cargas não-lineares; gerenciamento de perfil de tensão; e reconfiguração topológica com a finalidade de reduzir as perdas elétricas. Todas as modelagens e desenvolvimentos destes estudos estão aqui relatados. Por fim, o trabalho se propõe a identificar os sistemas multiagentes como uma tecnologia a ser empregada tanto para a pesquisa, quanto para implementação dessas redes elétricas.
Resumo:
A busca no aumento da vida útil dos transformadores de distribuição, redução dos custos de manutenção e mitigação de falhas, leva ao desenvolvimento de novos materiais e critérios de exploração diferenciados desses ativos. Esta pesquisa apresenta o desenvolvimento de um novo transformador de distribuição compacto e mais eficiente utilizando óleo vegetal isolante totalmente biodegradável. Além de biodegradável, o óleo vegetal utilizado possui menor agressividade ambiental e maior capacidade térmica aumentando, a capacidade de carregamento do transformador sem comprometer a sua vida útil. A fim de atestar essa menor agressividade em relação ao óleo mineral, ensaios foram efetuados em um equipamento que permaneceu 12 anos em operação. O equipamento foi totalmente desmontado para análise e coleta de amostras de papel e óleo vegetal isolante. As análises visam comprovar a menor agressividade em relação ao óleo mineral, apresentadas na revisão bibliográfica. A menor agressividade torna possível a proposição de uma nova filosofia de planejamento de redes de distribuição utilizando uma quantidade menor dos novos transformadores para uma mesma carga, tornando-a mais compacta e eficiente.
Resumo:
Hoje no mercado brasileiro de eletricidade, o preço da energia convencional é composto pela soma do valor do Preço de Liquidação das Diferenças (PLD) divulgado pela Câmara de Comercialização de Energia Elétrica (CCEE) semanalmente com o valor do Spread negociado bilateralmente no mercado à vista (mercado de curto prazo), resultante do equilíbrio entre oferta e demanda. Em alguns momentos, o valor do Spread chega a representar mais de 100% do custo total da energia. Este trabalho faz uma análise do mercado brasileiro, bem como, de alguns mercados no exterior de energia elétrica e destaca os pontos que tem influência direta, na formação do Spread da energia convencional e como isso afeta a decisão de contratação dos agentes. Além disso, o trabalho busca encontrar correlações entre dados divulgados, como carga e oferta de energia, com o ágio negociado no mercado de curto prazo, buscando entender o real impacto de cada um desses fatores e explicar as grandes variações já observadas. Sugere-se também um modelo de regressão linear múltipla para a projeção de valores do ágio. Para tanto, foram utilizadas informações proveniente de um banco de dados de cotações de negócios efetivamente realizados no curto prazo desde janeiro de 2011 até julho de 2014, bem como informações retiradas da CCEE e Operador Nacional do Sistema (ONS).