995 resultados para Thickness direction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuronal circuit asymmetries are important components of brain circuits, but the molecular pathways leading to their establishment remain unknown. Here we found that the mutation of FRMD7, a gene that is defective in human congenital nystagmus, leads to the selective loss of the horizontal optokinetic reflex in mice, as it does in humans. This is accompanied by the selective loss of horizontal direction selectivity in retinal ganglion cells and the transition from asymmetric to symmetric inhibitory input to horizontal direction-selective ganglion cells. In wild-type retinas, we found FRMD7 specifically expressed in starburst amacrine cells, the interneuron type that provides asymmetric inhibition to direction-selective retinal ganglion cells. This work identifies FRMD7 as a key regulator in establishing a neuronal circuit asymmetry, and it suggests the involvement of a specific inhibitory neuron type in the pathophysiology of a neurological disease. VIDEO ABSTRACT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid manufacturing is an advanced manufacturing technology based on layer-by-layer manufacturing to produce a part. This paper presents experimental work carried out to investigate the effects of scan speed, layer thickness, and building direction on the following part features: dimensional error, surface roughness, and mechanical properties for DMLS with DS H20 powder and SLM with CL 20 powder (1.4404/AISI 316L). Findings were evaluated using ANOVA analysis. According to the experimental results, build direction has a significant effect on part quality, in terms of dimensional error and surface roughness. For the SLM process, the build direction has no influence on mechanical properties. Results of this research support industry estimating part quality and mechanical properties before the production of parts with additive manufacturing, using iron-based powders

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Early Cretaceous has experienced the development of large shallow-water carbonate platform in tropical and subtropical regions, favoured by exceptionally warm climatic conditions, optimal trophic conditions and a suitable tectonic and paleogeographic context. This period was also characterized by shorter intervals, in which the widespread deposition of marine sediments enriched in organic matter occurred ("oceanic anoxic episodes": OAE). This study focuses on the Barremian- Aptian interval, during which the Urgonian platform developed throughout the northern Tethyan passive margin. Due to the Alpine orogeny, sediments belonging to this platform - named locally Schrattenkalk Formation, are presently outcropping in the Helvetic Alps. This study aims to reconstruct the paleogeographic evolution of the Helvetic platform, and to define the environmental and oceanographic factors, which influenced its development. Several key episodes in the life of this platform have been identified: - The installation of the platform, covering hemipelagic sediments of the Drusberg Member, near the limit between the early and late Barremian. - The temporary change of carbonate production type during the basal Aptian, with the deposition of the Rawil Member. - And finally the definitive interruption of photozoan carbonate platform sedimentation in the study area, during the early Aptian. The sedimentological, biostratigraphical and chemostratigraphic (8I3C) data lead to the sequential subdivision of eleven sections and one core, located throughout the different Helvetic nappes of Switzerland. The sequence stratigraphie framework, initially defined for the Urgonian carbonate platform of the Vercors area (SE France), is confirmed in the Helvetic nappes, where the same number of sequences was observed. Many similarities between these two areas are put forward in this work. The sequence stratigraphie framework helped to highlight the installation of a bioclastic body, included in the Schrattenkalk Formation, since the middle Early Barremian (sequence B2). The age of the installation of the rudist-rich limestone, which corresponds to the Urgonian facies sensu stricto, is attributed to the late Barremian (maximum flooding surface of the sequence B3). This age coincides with the one determined in other northern Tethyan areas for the installation of the Urgonian platform. The results of this study show a strong tectonic control of the platform architecture, with the presence of syn-sedimentary faults in a perpendicular position to the progradation direction of the platform. The presence of these faults was highlighted by the study of the evolution of the microfacies distribution and by thickness variations in different areas. Sea level fluctuations also played an important role in the various life phases of the platform. Three major falls in sea level have been identified. A significant emersion of the proximal domain has been observed, involving an important drop of the relative sea level, leading to the exposure of the Drusberg Member hemipelagic series. A second major drop in sea level is identified near the Barremian-Aptian boundary, and a third is registered on the top of the Upper Schrattenkalk Member on the whole platform; it is associated with a karst affecting the underlying limestones to a depth of over 20 meters. This observation sheds new light on the conditions linked to the demise of Urgonian platform, which was strongly influenced by this phase of emersion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Partial-thickness tears of the supraspinatus tendon frequently occur at its insertion on the greater tubercule of the humerus, causing pain and reduced strength and range of motion. The goal of this work was to quantify the loss of loading capacity due to tendon tears at the insertion area. A finite element model of the supraspinatus tendon was developed using in vivo magnetic resonance images data. The tendon was represented by an anisotropic hyperelastic constitutive law identified with experimental measurements. A failure criterion was proposed and calibrated with experimental data. A partial-thickness tear was gradually increased, starting from the deep articular-sided fibres. For different values of tendon tear thickness, the tendon was mechanically loaded up to failure. The numerical model predicted a loss in loading capacity of the tendon as the tear thickness progressed. Tendon failure was more likely when the tendon tear exceeded 20%. The predictions of the model were consistent with experimental studies. Partial-thickness tears below 40% tear are sufficiently stable to persist physiotherapeutic exercises. Above 60% tear surgery should be considered to restore shoulder strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the presence of linear relationship between renal cortical thickness, bipolar length, and parenchymal thickness in chronic kidney disease patients presenting with different estimated glomerular filtration rates (GFRs) and to assess the reproducibility of these measurements using ultrasonography. Materials and Methods: Ultrasonography was performed in 54 chronic renal failure patients. The scans were performed by two independent and blinded radiologists. The estimated GFR was calculated using the Cockcroft-Gault equation. Interobserver agreement was calculated and a linear correlation coefficient (r) was determined in order to establish the relationship between the different renal measurements and estimated GFR. Results: The correlation between GFR and measurements of renal cortical thickness, bipolar length, and parenchymal thickness was, respectively, moderate (r = 0.478; p < 0.001), poor (r = 0.380; p = 0.004), and poor (r = 0.277; p = 0.116). The interobserver agreement was considered excellent (0.754) for measurements of cortical thickness and bipolar length (0.833), and satisfactory for parenchymal thickness (0.523). Conclusion: The interobserver reproducibility for renal measurements obtained was good. A moderate correlation was observed between estimated GFR and cortical thickness, but bipolar length and parenchymal thickness were poorly correlated.