993 resultados para SIMPLE ASSAY
Resumo:
A simple and rapid staphylococcal coagglutination test for the detection of Toxoplasma gondii antigens in mice urine is described. A suspension of protein-A containing Staphylococcus aureus coated with rabbit hyperimmune serum was used as reagent. The sensitivity of the antigen assay was found to be at least 118 ng of the antigen protein per ml. No coagglutination was observed when the reagent was challenged against antigenic solutions of other parasites. The suitability of the method for detecting antigens of T. gondii in urine samples was studied by experimental toxoplasma infection in mice. Before the staphylococcal test, the urine samples were double serially diluted in 0.1 M PBS. From the second day on all samples from infected mice were positive at 1/16 dilution. At this dilution, all samples from non infected mice were negative or did not produce coagglutination. This method might be used in the rapid etiological diagnosis also in human cases of acute toxoplasmosis.
Resumo:
This paper investigates dynamic completeness of financial markets in which the underlying risk process is a multi-dimensional Brownian motion and the risky securities dividends geometric Brownian motions. A sufficient condition, that the instantaneous dispersion matrix of the relative dividends is non-degenerate, was established recently in the literature for single-commodity, pure-exchange economies with many heterogenous agents, under the assumption that the intermediate flows of all dividends, utilities, and endowments are analytic functions. For the current setting, a different mathematical argument in which analyticity is not needed shows that a slightly weaker condition suffices for general pricing kernels. That is, dynamic completeness obtains irrespectively of preferences, endowments, and other structural elements (such as whether or not the budget constraints include only pure exchange, whether or not the time horizon is finite with lump-sum dividends available on the terminal date, etc.)
Resumo:
The assessment of yellow fever vaccine thermostability both in lyophilized form and after reconstitution were analyzed. Two commercial yellow fever vaccines were assayed for their thermal stability. Vaccines were exposed to test temperatures in the range of 8 (graus) C to 45 (graus) C. Residual infectivity was measured by a plaque assay using Vero cells. The titre values were used in an accelerated degradation test that follows the Arrhenius equation and the minimum immunizing dose was assumed to be 10 (ao cubo) particles forming unit (pfu)/dose. Some of the most relevant results include that (i) regular culture medium show the same degradation pattern of a reconstituted 17D-204 vaccine; (ii) reconstituted YF-17D-204 showed a predictable half life of more than six days if kept at 0 (graus) C; (iii) there are differences in thermostability between different products that are probably due to both presence of stabilizers in the preparation and the modernization in the vaccine production; (iv) it is important to establish a proper correlation between the mouse infectivity test and the plaque assay since the last appears to be more simple, economical, and practical for small laboratories to assess the potency of the vaccine, and (v) the accelerated degradation test appears to be the best procedure to quantify the thermostability of biological products.
Resumo:
BACKGROUND: Invasive fungal infections (IFIs) are life-threatening complications in patients with hemato-oncological malignancies, and early diagnosis is crucial for outcome. The compound 1,3-β-D-glucan (BG), a cell wall component of most fungal species, can be detected in blood during IFI. Four commercial BG antigenemia assays are available (Fungitell, Fungitec-G, Wako, and Maruha). This meta-analysis from the Third European Conference on Infections in Leukemia (ECIL-3) assessed the performance of BG assays for the diagnosis of IFI in hemato-oncological patients. METHODS: Studies reporting the performance of BG antigenemia assays for the diagnosis of IFI (European Organization for Research and Treatment of Cancer and Mycoses Study Group criteria) in hemato-oncological patients were identified. The analysis was focused on high-quality cohort studies with exclusion of case-control studies. Meta-analysis was performed by conventional meta-analytical pooling and bivariate analysis. RESULTS: Six cohort studies were included (1771 adult patients with 414 IFIs of which 215 were proven or probable). Similar performance was observed among the different BG assays. For the cutoff recommended by the manufacturer, the diagnostic performance of the BG assay in proven or probable IFI was better with 2 consecutive positive test results (diagnostic odds ratio for 2 consecutive vs one single positive results, 111.8 [95% confidence interval {CI}, 38.6-324.1] vs 16.3 [95% CI, 6.5-40.8], respectively; heterogeneity index for 2 consecutive vs one single positive results, 0% vs 72.6%, respectively). For 2 consecutive tests, sensitivity and specificity were 49.6% (95% CI, 34.0%-65.3%) and 98.9% (95% CI, 97.4%-99.5%), respectively. Estimated positive and negative predictive values for an IFI prevalence of 10% were 83.5% and 94.6%, respectively. CONCLUSIONS: Different BG assays have similar accuracy for the diagnosis of IFI in hemato-oncological patients. Two consecutive positive antigenemia assays have very high specificity, positive predictive value, and negative predictive value. Because sensitivity is low, the test needs to be combined with clinical, radiological, and microbiological findings.
Resumo:
Dacron (polyethylenetherephthalate) is proposed as a matrix for dot-ELISA procedures, as an alternative to nitrocellulose. Plates of dacron were partially hydrazinolyzed and hydrazide groups introduced were converted to azide groups. The derivative dacron-antigen was covalently linked on to the plates through these azide groups. The derivative dacron-antigen was exaustively washed according to CROOK and antigen was still fixed onto the plates. Protein F1A purified from Yersinia pestis was used as a model. Triration of sera from immunized and non immunized rabbits against this protein was carried out by employing the dot-ELISA method. No significant difference was observed using dacron-antigen and nitrocellulose-antigen preparations. However, both procedures showed to have a significant better performance in comparasion with the passive hemagglutination method. The specificity and reproductibility of the dot-ELISA assay using both preparations showed a similar behaviour. Nitrocellulose preparation was stable at 4ºC, 28ºC and -20ºC for 90 days, whereas the dacron-antigen derivative was stable only when stored at 4ºC. Dacron-antigen derivative could be re-used when the spot developing was proceeded using 4-chloro-1-naphtol as substrate.
Resumo:
The ability to identify the species origin of an unknown biological sample is relevant in the fields of human and wildlife forensics. However, the detection of several species mixed in the same sample still remains a challenge. We developed and tested a new approach for mammal DNA identification in mixtures of two or three species, based on the analysis of mitochondrial DNA control region interspecific length polymorphism followed by direct sequencing. Contrary to other published methods dealing with species mixtures, our protocol requires a single universal primer pair and is not based on a pre-defined panel of species. Amplicons can be separated either on agarose gels or using CE. The advantages and limitations of the assay are discussed under different conditions, such as variable template concentration, amplicon sizes and size difference among the amplicons present in the mixture. For the first time, this protocol provides a simple, reliable and flexible method for simultaneous identification of multiple mammalian species from mixtures, without any prior knowledge of the species involved.
Resumo:
The passive haemagglutination (PHA) test, enzyme-linked immunosorbent assay (ELISA) and the dot enzyme-immunosorbent assay (DOT-ELISA) were used to detect the levels of IgG antibodies against the Fraction 1 (F1) antigen of Yersinia pestis in sera of plague-infected patients from Northeast Brazil. Twenty three selected PHA-positive sera of subjects with bacteriological confirmation of plague were also positive in the DOT-ELISA but only 19 were detected by the conventional ELISA technique. Another group of 186 serum samples from subjects diagnosed as plague-infected by clinical and epidemiological parameters, but PHA-negative, were screened with DOT-ELISA and 11 gave positive results. The specificity of the assays on the serological detection of plague was confirmed in inhibition tests using purified F1 antigen. These results suggest that DOT-ELISA can be an useful, simple and more sensitive alternative for the serodiagnosis of plague in Northeast Brazil.
Resumo:
Therapeutic drug monitoring (TDM) may contribute to optimizing the efficacy and safety of antifungal therapy because of the large variability in drug pharmacokinetics. Rapid, sensitive, and selective laboratory methods are needed for efficient TDM. Quantification of several antifungals in a single analytical run may best fulfill these requirements. We therefore developed a multiplex ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method requiring 100 μl of plasma for simultaneous quantification within 7 min of fluconazole, itraconazole, hydroxyitraconazole, posaconazole, voriconazole, voriconazole-N-oxide, caspofungin, and anidulafungin. Protein precipitation with acetonitrile was used in a single extraction procedure for eight analytes. After reverse-phase chromatographic separation, antifungals were quantified by electrospray ionization-triple-quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. Deuterated isotopic compounds of azole antifungals were used as internal standards. The method was validated based on FDA recommendations, including assessment of extraction yields, matrix effect variability (<9.2%), and analytical recovery (80.1 to 107%). The method is sensitive (lower limits of azole quantification, 0.01 to 0.1 μg/ml; those of echinocandin quantification, 0.06 to 0.1 μg/ml), accurate (intra- and interassay biases of -9.9 to +5% and -4.0 to +8.8%, respectively), and precise (intra- and interassay coefficients of variation of 1.2 to 11.1% and 1.2 to 8.9%, respectively) over clinical concentration ranges (upper limits of quantification, 5 to 50 μg/ml). Thus, we developed a simple, rapid, and robust multiplex UPLC-MS/MS assay for simultaneous quantification of plasma concentrations of six antifungals and two metabolites. This offers, by optimized and cost-effective lab resource utilization, an efficient tool for daily routine TDM aimed at maximizing the real-time efficacy and safety of different recommended single-drug antifungal regimens and combination salvage therapies, as well as a tool for clinical research.
Resumo:
The present report describes an alternative method for in vitro detection of HIV-1 -specific antibody secretion in 24h of culture employing as stimulant of peripheral blood mononuclear cells the disrupted inactivated whole virus adsorbed onto microwells in a commercial ELISA kit plates. The results obtained from this technique have showed high sensitivity and specificity since it was capable of detecting HIV-1 infection early after birth. There were neither false-positivity nor false-negativity when blood samples obtained from HIV-1 seronegative asymptomatic individuals, and HIV-1 seropositive adult patients were analized. This rapid, low cost, simple, highly sensitive and specific assay can be extremely useful for early diagnosis of pediatric HIV infection.
Resumo:
A consecutive series of 353 patients who underwent Lichtenstein mesh repair for inguinal hernia from the 1st of July 1994 to the 30th of July 1995 were studied. We analysed our indication, technique, complications, follow-up and outcome. Special consideration was given to the advantages and acceptance of day-case surgery. Our results suggest that the Lichtenstein repair should be considered as a new standard procedure, especially outside of hernia centres.
Resumo:
The few studies already published about phagocyte functions in Chediak-Higashi syndrome (CHS) has stated that neutrophils present slow rate of bacterial killing but normally ingest microorganisms. In the present study, both phagocytosis and killing of Staphylococcus aureus were verified to be in neutrophils from two patients with CHS when these functions were simultaneously evaluated by a fluorochrome phagocytosis assay. Electron microscopic examination showed morphologic differences among neutophils from CHS patients and normal neutrophils regarding the cytoplasmic structures and the aspects of the phagolysosomes. It was noteworthy the presence of giant phagolysosomes enclosing bacteria in active proliferation commonly observed in CHS neutrophils after 45 min of phagocytosis, wich corresponded with the impaired bactericidal activity of these leukocytes. The present results suggest that phagocytosis may also be defective in CHS, and point out to the sensitivity of the fluorochrome phagocytosis assay and its application in clinical laboratories.
Resumo:
The WHO criterion of defering any donation of blood by a confirmed case of malaria for three years after cessation of therapy can not be applied in areas where malaria in endemic. For this reason we developed an immunoenzymatic assay for the detection of plasmodial antigens for blood screening in malararial endemic areas. So, we tested sera from 191 individuals. Among patients with active disease 100% of the cases of Plasmodium falciparum or mixed infections and 91.7% of those with P. vivax were positive for the presence of plasmodial antigens. The lower parasitaemia detected was 0.0003% for P. vivax malária. When the frequency of positive circulating malarial antigens was evaluated among asymptomatic and symptomatic individuals with negative TBS, positive results were found in respectively 38.7% and 17.7% of the individuals studied in the 30 days after confirmed malaria attack. Data provide by these assays have shown that ELISA seemed to be more sensitive than parasitological examination for malaria diagnosis. This test by virtue of its high sensivity and the facilities in processing a large number of specimens, can prove to be useful in endemic areas for the recognition of asymptomatic malaria and screening of blood donors.
Resumo:
Schistosomiasis in Americawith the exception of Brazil, behaves as a chronic mild disease with few clinical manifestations due to low parasite burden. These features restrict the clinical and parasitological diagnosis. The most commonly used stool examination method, Kato-Katz, becomes intensitive when the majority of individuals excrete less than 100 eggs/g of feces. In view that antigen-detecting techniques have not been able to reveal light infections, the antibody detecting assays remain as a very valuable diagnostic tool for epidemiological surveillance. The Venezuelan Schistosomiasis Research group (CECOICE) has designed a mass chemotherapy strategy based on sero-diagnosis. Since blood sampling is one of the important limitating factors for large seroepidemiological trials we developed a simple capillary technique that sucessfully overcomed most of the limitations of blood drawing. In this sense, ELISA seems to be the most adecuate test for epidemiological studies. Soluble egg Schistosoma mansoni antigen (SEA) has been largely used in Venezuela. The sensitivity ELISA-SEA in our hands is 90% moreover its specific reach 92% when populations from non-endemic areas but heavily infected with other intestinal parasites are analyzed. The Schistosomiasis Control Program is currently carrying out the surveillance of endemic areas using ELISA-SEA as the first screening method, followed by the Circumoval Precipitin test for validation assay. The results with these two serological techniques allowed us to defined the criteria of chemotherapy in populations of the endemic areas. On the search of better diagnostic technique, Alkaline Phosphatase Immunoenzyme Assay (APIA) is being evaluated in field surveys.