978 resultados para Reliability management


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of the study was to evaluate clinical and laboratorial features of 1234 patients with different etiologies of hyper-prolactinemia, as well as the response of 388 patients with prolactinomas to dopamine agonists. Design, setting, and patients: A total of 1234 hyperprolactinemic patients from 10 Brazilian endocrine centers were enrolled in this retrospective study. Main outcome measure: PRL measurement, thyroid function tests, and screening for macroprolactin were conducted. Results: Patients were subdivided as follows: 56.2% had prolactinomas, 14.5% drug-induced hyperprolactinemia, 9.3% macroprolactinemia, 6.6% non-functioning pituitary adenomas, 6.3% primary hypothyroidism, 3.6% idiopathic hyperprolactinemia, and 3.2% acromegaly. Clinical manifestations were similar irrespective of the etiology of the hyperprolactinemia. The highest PRL levels were observed in patients with prolactinomas but there was a great overlap in PRL values between all groups. However, PRL>500 ng/ml allowed a clear distinction between prolactinomas and the other etiologies. Cabergoline (CAB) was more effective than bromocriptine (BCR) in normalizing PRL levels (81.9% vs 67.1%, p<0.0001) and in inducing significant tumor shrinkage and complete disappearance of tumor mass. Drug resistance was observed in 10% of patients treated with CAB and in 18.4% of those that used BCR (p=0.0006). Side-effects and intolerance were also more common in BCR-treated patients. Conclusion: Prolactinomas, drug-induced hyperprolactinemia, and macroprolactinemia were the 3 most common causes of hyperprolactinemia. Although PRL levels could not reliably define the etiology of hyperprolactinemia, PRL values >500 ng/ml were exclusively seen in patients with prolactinomas. CAB was significantly more effective than BCR in terms of prolactin normalization, tumor shrinkage, and tolerability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To develop a model to predict the bleeding source and identify the cohort amongst patients with acute gastrointestinal bleeding (GIB) who require urgent intervention, including endoscopy. Patients with acute GIB, an unpredictable event, are most commonly evaluated and managed by non-gastroenterologists. Rapid and consistently reliable risk stratification of patients with acute GIB for urgent endoscopy may potentially improve outcomes amongst such patients by targeting scarce health-care resources to those who need it the most. Design and methods: Using ICD-9 codes for acute GIB, 189 patients with acute GIB and all. available data variables required to develop and test models were identified from a hospital medical records database. Data on 122 patients was utilized for development of the model and on 67 patients utilized to perform comparative analysis of the models. Clinical data such as presenting signs and symptoms, demographic data, presence of co-morbidities, laboratory data and corresponding endoscopic diagnosis and outcomes were collected. Clinical data and endoscopic diagnosis collected for each patient was utilized to retrospectively ascertain optimal management for each patient. Clinical presentations and corresponding treatment was utilized as training examples. Eight mathematical models including artificial neural network (ANN), support vector machine (SVM), k-nearest neighbor, linear discriminant analysis (LDA), shrunken centroid (SC), random forest (RF), logistic regression, and boosting were trained and tested. The performance of these models was compared using standard statistical analysis and ROC curves. Results: Overall the random forest model best predicted the source, need for resuscitation, and disposition with accuracies of approximately 80% or higher (accuracy for endoscopy was greater than 75%). The area under ROC curve for RF was greater than 0.85, indicating excellent performance by the random forest model Conclusion: While most mathematical models are effective as a decision support system for evaluation and management of patients with acute GIB, in our testing, the RF model consistently demonstrated the best performance. Amongst patients presenting with acute GIB, mathematical models may facilitate the identification of the source of GIB, need for intervention and allow optimization of care and healthcare resource allocation; these however require further validation. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine whether peer-reviewed consensus statements have changed clinical practice, we surveyed acromegaly care in specialist centers across the globe, and determined the degree of adherence to published consensus guidelines on acromegaly management. Sixty-five acromegaly experts who participated in the 7th Acromegaly Consensus Workshop in March 2009 responded. Results indicated that the most common referring sources for acromegaly patients were other endocrinologists (in 26% of centers), neurosurgeons (25%) and primary care physicians (21%). In sixty-nine percent of patients, biochemical diagnoses were made by evaluating results of a combination of growth hormone (GH) nadir/basal GH and elevated insulin like growth factor-I (IGF-I) levels. In both Europe and the USA, neurosurgery was the treatment of choice for GH-secreting microadenomas and for macroadenomas with compromised visual function. The most widely used criteria for neurosurgical outcome assessment were combined measurements of IGF-I and GH levels after oral glucose tolerance test (OGTT) 3 months after surgery. Ninety-eight percent of respondents stated that primary treatment with somatostatin receptor ligands (SRLs) was indicated at least sometime during the management of acromegaly patients. In nearly all centers (96%), the use of pegvisomant monotherapy was restricted to patients who had failed to achieve biochemical control with SRL therapy. The observation that most centers followed consensus statement recommendations encourages the future utility of these workshops aimed to create uniform management standards for acromegaly.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Intervertebral cervical disc herniation (CDH) is a relatively common disorder that can coexist with degenerative changes to worsen cervicogenic myelopathy. Despite the frequent disc abnormalities found in asymptomatic populations, magnetic resonance imaging (MRI) is considered excellent at detecting cervical spine myelopathy (CSM) associated with disc abnormality. The objective of this study was to investigate the intra- and inter-observer reliability of MRI detection of CSM in subjects who also had co-existing intervertebral disc abnormalities. Materials and methods: Seven experienced radiologists reviewed twice the MRI of 10 patients with clinically and/or imaging determined myelopathy. MRI assessment was performed individually, with and without operational guidelines. A Fleiss Kappa statistic was used to evaluate the intra- and inter-observer agreement. Results: The study found high intra-observer percent agreement but relatively low Kappa values on selected variables. Inter-observer reliability was also low and neither observation was improved with operational guidelines. We believe that those low values may be associated with the base rate problem of Kappa. Conclusion: In conclusion, this study demonstrated high intra-observer percent agreement in MR examination for intervertebral disc abnormalities in patients with underlying cervical myelopathy, but differing levels of intra- and inter-observer Kappa agreement among seven radiologists. (c) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sporadic lymphangiectasias are commonly found throughout the small bowel and are considered to be normal. Not uncommonly, lymphangiectasias are pathologic and can lead to mid-gastrointestinal bleeding, abdominal pain and protein-losing enteropathy. Pathologic lymphangiectasias of the small bowel include primary lymphangiectasia, secondary lymphangiectasia and lymphaticovenous malformations. In this report we present three different cases of small bowel lymphangiectasia detected by double balloon enteroscopy. The patients were diagnosed with South American blastomycosis, tuberculosis and primary small bowel lymphangioma. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to assess the reliability of intra and inter-examiner subacromial impingement index (SII) measures obtained from radiographs. Thirty-six individuals were enrolled and divided into two groups: control group, composed of 18 volunteers in good general health without shoulder problems, and a group of 18 patients with subacromial impingement syndrome (SIS). Radiographic images were taken with the dominant upper limb in neutral rotation, while the volunteers held their arm at 90A degrees of abduction in the frontal plane. The beam of radiation at 30A degrees craniocaudal inclination was used to provide an antero-posterior image view. Three blinded examiners each performed three measurements from the subacromial space (SS) and the anatomical neck of the humerus (NH). The SII was calculated as the ratio of the SS and the NH measures. The mean values of SII were compared using t-tests. The intra-class correlation coefficient (ICC) was used to assess intra- and inter-examiner reliability of the measures. The mean values of SII were greater for the control group (0.12) than for the SIS group (0.08; p = 0.0071). SII measurements showed excellent intra (0.96-0.99) and inter-examiner reliability (0.94) for both the control and SIS group. The results of this study show the potential use of the SII; a greater mean value for the control group compared to the SIS group and excellent reliability for intra- and inter-examiner measurement. Validation studies of the index should be conducted to correlate the index with clinical findings from subacromial impingement syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.