1000 resultados para RESONANCE INTEGRAL


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sección "Buenas prácticas en gestión clínica"

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Partiendo de un sistema SAP R/3 implantado en las áreas de financiera, comercial y recursos humanos de una empresa modelo llamada Aguama, se plantea su ampliación a las áreas de explotación, proyectos y planificación.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods are presented to map complex fiber architectures in tissues by imaging the 3D spectra of tissue water diffusion with MR. First, theoretical considerations show why and under what conditions diffusion contrast is positive. Using this result, spin displacement spectra that are conventionally phase-encoded can be accurately reconstructed by a Fourier transform of the measured signal's modulus. Second, studies of in vitro and in vivo samples demonstrate correspondence between the orientational maxima of the diffusion spectrum and those of the fiber orientation density at each location. In specimens with complex muscular tissue, such as the tongue, diffusion spectrum images show characteristic local heterogeneities of fiber architectures, including angular dispersion and intersection. Cerebral diffusion spectra acquired in normal human subjects resolve known white matter tracts and tract intersections. Finally, the relation between the presented model-free imaging technique and other available diffusion MRI schemes is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical use of the Stejskal-Tanner diffusion weighted images is hampered by the geometric distortions that result from the large residual 3-D eddy current field induced. In this work, we aimed to predict, using linear response theory, the residual 3-D eddy current field required for geometric distortion correction based on phantom eddy current field measurements. The predicted 3-D eddy current field induced by the diffusion-weighting gradients was able to reduce the root mean square error of the residual eddy current field to ~1 Hz. The model's performance was tested on diffusion weighted images of four normal volunteers, following distortion correction, the quality of the Stejskal-Tanner diffusion-weighted images was found to have comparable quality to image registration based corrections (FSL) at low b-values. Unlike registration techniques the correction was not hindered by low SNR at high b-values, and results in improved image quality relative to FSL. Characterization of the 3-D eddy current field with linear response theory enables the prediction of the 3-D eddy current field required to correct eddy current induced geometric distortions for a wide range of clinical and high b-value protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Publicado en la página web de la Consejería de Igualdad, Salud y Políticas Sociales: www.juntadeandalucia.es/salud (Consejería de Igualdad, Salud y Políticas Sociales / Ciudadanía / Quiénes somos / Planes y Estrategias)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El desenvolupament del càlcul diferencial i integral com a disciplina científica a Europa durant el segle XVIII no és un tema nou. Però s’ha acostumat a enfocar la visió d’aquesta formació molt sovint des del “centre” i a partir de les grans figures com Isaac Newton o Gottfried Wilhelm Leibniz. En el present treball el protagonista potser, per a molts, no és una figura de primera línia; Tomàs Cerdà, és un ensenyant a Barcelona i a Madrid durant la segona meitat del segle XVIII, que “tradueix” al castellà autors anglesos, però que amb la seva pràctica està realment introduint el nou càlcul a Espanya i donant, de fet, una orientació d’aquesta nova disciplina als seus deixebles. El com i per què Cerdà decideix quin serà el seu guia en la introducció del càlcul diferencial i integral i quines seran les seves pròpies aportacions en aquesta labor seran els temes centrals del nostre treball. La nostra tasca ha anat, així doncs, a entendre millor, el procés de divulgació del coneixement científic, veient-lo en tot moment com formant part activa del mateix procés de construcció d’aquest coneixement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After the landmark studies reporting changes in the cerebral metabolic rate of glucose (CMRGlc ) in excess of those in oxygen (CMRO2 ) during physiological stimulation, several studies have examined the fate of the extra carbon taken up by the brain, reporting a wide range of changes in brain lactate from 20% to 250%. The present study reports functional magnetic resonance spectroscopy measurements at 7 Tesla using the enhanced sensitivity to study a small cohort (n = 6). Small increases in lactate (19% ± 4%, P < 0.05) and glutamate (4% ± 1%, P < 0.001) were seen within the first 2 min of activation. With the exception of glucose (12% ± 5%, P < 0.001), no other metabolite concentration changes beyond experimental error were significantly observed. Therefore, the present study confirms that lactate and glutamate changes during physiological stimulation are small (i.e. below 20%) and shows that the increased sensitivity allows reproduction of previous results with fewer subjects. In addition, the initial rate of glutamate and lactate concentration increases implies an increase in CMRO2 that is slightly below that of CMRGlc during the first 1-2 min of activation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: An accurate, noninvasive technique for the diagnosis of coronary disease would be an important advance. We investigated the accuracy of coronary magnetic resonance angiography among patients with suspected coronary disease in a prospective, multicenter study. METHODS: Coronary magnetic resonance angiography was performed during free breathing in 109 patients before elective x-ray coronary angiography, and the results of the two diagnostic procedures were compared. RESULTS: A total of 636 of 759 proximal and middle segments of coronary arteries (84 percent) were interpretable on magnetic resonance angiography. In these segments, 78 (83 percent) of 94 clinically significant lesions (those with a > or = 50 percent reduction in diameter on x-ray angiography) were also detected by magnetic resonance angiography. Overall, coronary magnetic resonance angiography had an accuracy of 72 percent (95 percent confidence interval, 63 to 81 percent) in diagnosing coronary artery disease. The sensitivity, specificity, and accuracy for patients with disease of the left main coronary artery or three-vessel disease were 100 percent (95 percent confidence interval, 97 to 100 percent), 85 percent (95 percent confidence interval, 78 to 92 percent), and 87 percent (95 percent confidence interval, 81 to 93 percent), respectively. The negative predictive values for any coronary artery disease and for left main artery or three-vessel disease were 81 percent (95 percent confidence interval, 73 to 89 percent) and 100 percent (95 percent confidence interval, 97 to 100 percent), respectively. CONCLUSIONS: Among patients referred for their first x-ray coronary angiogram, three-dimensional coronary magnetic resonance angiography allows for the accurate detection of coronary artery disease of the proximal and middle segments. This noninvasive approach reliably identifies (or rules out) left main coronary artery or three-vessel disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MRI tractography is the mapping of neural fiber pathways based on diffusion MRI of tissue diffusion anisotropy. Tractography based on diffusion tensor imaging (DTI) cannot directly image multiple fiber orientations within a single voxel. To address this limitation, diffusion spectrum MRI (DSI) and related methods were developed to image complex distributions of intravoxel fiber orientation. Here we demonstrate that tractography based on DSI has the capacity to image crossing fibers in neural tissue. DSI was performed in formalin-fixed brains of adult macaque and in the brains of healthy human subjects. Fiber tract solutions were constructed by a streamline procedure, following directions of maximum diffusion at every point, and analyzed in an interactive visualization environment (TrackVis). We report that DSI tractography accurately shows the known anatomic fiber crossings in optic chiasm, centrum semiovale, and brainstem; fiber intersections in gray matter, including cerebellar folia and the caudate nucleus; and radial fiber architecture in cerebral cortex. In contrast, none of these examples of fiber crossing and complex structure was identified by DTI analysis of the same data sets. These findings indicate that DSI tractography is able to image crossing fibers in neural tissue, an essential step toward non-invasive imaging of connectional neuroanatomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El proyecto surge con el fin de crear una aplicación que responda a las necesidades de gestión y control de las actividades que se desarrollan en empresas minoristas dedicadas al sector de la electrónica de consumo. Este tipo de establecimientos aunque están muy especializados y proporcionan un trato excelente al público, suelen tener deficiencias técnicas a la hora de gestionar y controlar su negocio. Muchos de ellos carecen de programas informáticos adaptados a sus necesidades, e incluso en algún caso no disponen de ninguno por el alto coste que les supone. Dicho software tiene dos objetivos: por un lado atender las necesidades de este sector y por otro que el desembolso de la adquisición e implantación del mismo sea asequible. Para conseguir este último objetivo se utilizará software libre.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El trabajo consiste en el desarrollo de una aplicación en .NET que gestiona los diferentes concesionarios que tiene un grupo automovilístico, sus departamentos y sus trabajadores. El resultado es una única aplicación de escritorio desarrollada en Windows Forms que integra las diferentes funcionalidades asociadas al departamento de ventas y taller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As autoras apresentam um relato de caso de recuperação nutricional de criança desnutrida, envolvida no Projeto de Recuperação Integral do Desnutrido implantado no Ambulatório de Pediatria do Hospital Universitário de Campo Grande, Mato Grosso do Sul. Mostram a importância da atuação do enfermeiro como membro da equipe multiprofissional em projetos dessa natureza.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste artigo, discutimos implicações políticas e práticas vinculadas a diferentes interpretações do conceito atenção integral à saúde da mulher, tomando por referência a multidimensionalidade humana/feminina.