892 resultados para POST-OPERATIVE COMPLICATIONS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To assess comparatively the inflammatory response that follows CO2 or Ringer's lactate joint capsular distension of horses submitted to experimental arthroscopy METHODS: Each animal was submitted to a bilateral tarsocrural arthroscopy employing gas distention in one joint and fluid distention in the contralateral joint. Synovial fluid was evaluated at 0, six, 12, 24 and 48 hours post-operative. RESULTS: The use of CO2 for arthroscopy causes an acute and mild synovitis alike to the liquid capsular distension, showing similar synovial fluid increase of leukocytes, TP, and TNF-alpha. Although synovial fluid PGE(2) content was higher in joints submitted to CO2 distension, lower levels of hemoglobin and leukocytes oxidative burst after surgery indicates that CO2 arthroscopy decreased intra-articular bleeding and activation of infiltrating leukocytes. CONCLUSIONS: The use of CO2 for arthroscopic examination causes acute and mild synovitis that is similar to the effects caused by the liquid capsular distension. CO2 also seems to decrease intra-articular bleeding and activation of leukocytes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Serial C-reactive protein measurements have been used to diagnose and monitor the response to therapy in patients with pneumonia and other infectious diseases. Nonetheless, the role of C-reactive protein measurement after surgical treatment for pleural empyema is not well defined. The aim of this study is to describe the behavior of C-reactive protein levels after the surgical treatment of pleural empyema and to correlate this parameter with the patient's prognosis. METHODS: We retrospectively analyzed the records of patients with pleural empyema treated by either chest-tube drainage or surgery from January 2006 to December 2008. C-reactive protein levels were recorded preoperatively and 2 and 7 days postoperatively. The clinical outcome was binary: success or failure (mortality or the need for repeated pleural intervention). RESULTS: The study group comprised fifty-two patients. The median C-reactive protein values were as follows: 146 mg/L (pre-operative), 134 mg/L (post-operative day 2), and 116 mg/L (post-operative day 7). There was a trend toward a decrease in these values during the first week after surgery, but this difference was only statistically significant on day 7 after surgery. Over the first week after surgery, the C-reactive protein values decreased similarly in both groups (successful and failed treatment). No correlation between the preoperative C-reactive protein level and the clinical outcome was found. CONCLUSIONS: We observed that, in contrast to other medical conditions, C-reactive protein levels fall slowly during the first postoperative week in patients who have undergone surgical treatment for pleural empyema. No correlation between the perioperative C-reactive protein level and the clinical outcome was observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To evaluate the diagnostic accuracy of bronchoscopy in patients with clinical or radiological suspicion of tuberculosis who were unable to produce sputum or with negative sputum smear microscopy results. Methods: A prospective cross-sectional study involving 286 patients under clinical or radiological suspicion of having pulmonary tuberculosis and submitted to bronchoscopy-BAL and transbronchial biopsy (TBB). The BAL specimens were submitted to direct testing and culture for AFB and fungi, whereas the TBB specimens were submitted to histopathological examination. Results: Of the 286 patients studied, 225 (79%) were diagnosed on the basis of bronchoscopic findings, as follows: pulmonary tuberculosis, in 127 (44%); nonspecific chronic inflammation, in 51 (18%); pneumocystis, fungal infections, or nocardiosis, in 20 (7%); bronchiolitis obliterans organizing pneumonia, alveolites, or pneumoconiosis, in 14 (5%); lung or metastatic neoplasms, in 7 (2%); and nontuberculous mycobacterium infections, in 6 (2%). For the diagnosis of tuberculosis, BAL showed a sensitivity and a specificity of 60% and 100%, respectively. Adding the TBB findings significantly increased this sensitivity (to 84%), as did adding the post-bronchoscopy sputum smear microscopy results (total sensitivity, 94%). Minor post-procedure complications occurred in 5.6% of the cases. Conclusions: Bronchoscopy is a reliable method for the diagnosis of pulmonary tuberculosis, with low complication rates. The combination of TBB and BAL increases the sensitivity of the method and facilitates the differential diagnosis with other diseases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and objectives: Literature on preemptive analgesia is controversial. Reliability of results and difficult reproducibility of research contribute for non-elucidation of the subject. The aim of this study is to test the efficacy of oral ketoprofen (150 mg) preemptively administrated two days before third molar surgery, compared with postoperative administration in the same patient. Methods: Thirteen patients underwent surgical removal of bilateral third molar in two separate procedures. In a random and double blind procedure, oral ketoprofen 150 mg was administered every 12 hours two days before surgery and, after the procedure, the same drug was administered for three days. On the other side, a control (placebo) was used orally every 12 hours two days before surgery and, after the procedure, ketoprofen 150 mg was administered every 12 hours for three days. Postoperative pain was assessed by visual analogue scale, nominal scale, and amount of rescue analgesics consumed. Results: There was no statistically significant difference in postoperative pain between the preemptive treatment and control. Conclusion: In this experimental model, preemptive analgesia was not effective in reducing postoperative pain in surgical extraction of third molar compared with the postoperative administration of the same drug.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To evaluate the growth of children after repair of Tetralogy of Fallot, as well as the influence of residual lesions and socio-economic status. Methods: A total of 17 children, including 10 boys with a median age of 16 months at surgery, were enrolled in a retrospective cohort, in a tertiary care university hospital. Anthropometric (as z-scores), clinical, nutritional, and social data were collected. Results: Weight-for-age and weight-for-height z-scores decreased pre-operatively and recovered post-operatively in almost all patients, most markedly weight for age. Weight-for-height z-scores improved, but were still lower than birth values in the long term. Long-term height-for-age z-scores were higher than those at birth, surgery, and 3 months post-operatively. Most patients showed catch-up growth for height for age (70%), weight for age (82%), and weight for height (70%). Post-operative residual lesions (76%) influenced weight-for-age z-scores. Despite the fact that most patients (70%) were from low-income families, energy intake was above the estimated requirement for age and gender in all but one patient. There was no influence of socio-economic status on pre- and post-operative growth. Bone age was delayed and long-term-predicted height was within mid-parental height limits in 16 children (93%). Conclusion: Children submitted to Tetralogy of Fallot repair had pre-operative acute growth restriction and showed post-operative catch-up growth for weight and height. Acute growth restriction could still be present in the long term.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract Background Measurement of vital capacity (VC) by spirometry is the most widely used technique for lung function evaluation, however, this form of assessment is costly and further investigation of other reliable methods at lower cost is necessary. Objective: To analyze the correlation between direct vital capacity measured with ventilometer and with incentive inspirometer in patients in pre and post cardiac surgery. Methodology Cross-sectional comparative study with patients undergoing cardiac surgery. Respiratory parameters were evaluated through the measurement of VC performed by ventilometer and inspirometer. To analyze data normality the Kolmogorov-Smirnov test was applied, for correlation the Pearson correlation coefficient was used and for comparison of variables in pre and post operative period Student's t test was adopted. We established a level of ignificance of 5%. Data was presented as an average, standard deviation and relative frequency when needed. The significance level was set at 5%. Results We studied 52 patients undergoing cardiac surgery, 20 patients in preoperative with VC-ventilometer: 32.95 ± 11.4 ml/kg and VC-inspirometer: 28.9 ± 11 ml/Kg, r = 0.7 p < 0.001. In the post operatory, 32 patients were evaluated with VC-ventilometer: 28.27 ± 12.48 ml/kg and VC-inspirometer: 26.98 ± 11 ml/Kg, r = 0.95 p < 0.001. Presenting a very high correlation between the evaluation forms studied. Conclusion There was a high correlation between DVC measures with ventilometer and incentive spirometer in pre and post CABG surgery. Despite this, arises the necessity of further studies to evaluate the repercussion of this method in lowering costs at hospitals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A literatura sobre analgesia preemptiva é controversa. A confiabilidade dos resultados e a dificuldade de reprodutibilidade das pesquisas contribuem para a não elucidação do tema. O objetivo desse estudo é testar a eficácia da administração preemptiva de Cetoprofeno 150 mg via oral dois dias antes da cirurgia de extração deterceiros molares, comparando no mesmo paciente com a administração pós-operatória. MÉTODO: Treze pacientes foram submetidos à cirurgia de extração bilateral de terceiros molares inferiores inclusos em dois procedimentos distintos. De forma randomizada e duplo cega, em um procedimento foi administrado Cetoprofeno 150 mg via oral a cada 12 horas dois dias antes da cirurgia e, após o procedimento, continuou-se o mesmo medicamento por mais três dias. De outro lado, foi utilizado um controle (placebo) via oral a cada 12 horas dois dias antes da cirurgia e, após o procedimento, continuou-se o Cetoprofeno 150 mg a cada 12 horas por mais três dias. A dor pós-operatória foi avaliada por meio da escala visual analógica, da escala nominal e da quantidade de consumo de analgésicos de resgate. RESULTADOS: Não foi observada diferença estatisticamente significante na dor pós-operatória entre o tratamento preemptivo e o controle. CONCLUSÃO: Neste modelo experimental, a analgesia preemptiva não se mostrou eficaz na redução da dor pós-operatória na cirurgia de extração de terceiros molares inclusos em comparação com a administração pós-operatória do mesmo medicamento.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Delirium is defined as an acute disorder of attention and cognition. Delirium is common in hospitalized elderly patient and is associated with increased morbidity, length of stay and patient care costs. Although Delirium can develop at any time during hospitalization, it typically presents early in the post-operative period (Post-Operative Delirium, POD) in the surgery context. The molecular mechanism and possible genetics basis of POD onset are not known, as well as all the risk factors are not completely defined. Our hypothesis is that genetic risk factor involving the inflammatory response could have possible effects on the immunoneuroendocrine system. Moreover, our previous data (inflamm-aging) suggest that aging is associated with an increase of inflammatory status, favouring age-related diseases such as neurodegenerative diseases, frailty, depression among other. Some pro-inflammatory or anti-inflammatory cytokines, seem to play a crucial role in increasing the inflammatory status and in the communication and regulation of immunoneuroendocrine system. Objective: this study evaluated the incidence of POD in elderly patients undergoing general surgery, clinical/physical and psychological risk factors of POD insurgency and investigated inflammatory and genetic risk factors. Moreover, this study evaluated the consequence of POD in terms of institutionalization, development of permanent cognitive dysfunction or dementia and mortality Methods: patients aged over 65 admitted for surgery at the Urgency Unit of S.Orsola-Malpighi Hospital were eligible for this case–control study. Risk factors significantly associated with POD in univariate analysis were entered into multivariate analysis to establish those independently associated with POD. Preoperative plasma level of 9 inflammatory markers were measured in 42 control subjects and 43 subjects who developed POD. Functional polymorphisms of IL-1 α , IL-2, IL-6, IL-8, IL-10 and TNF-alpha cytokine genes were determined in 176 control subjects and 27 POD subjects. Results: A total of 351 patients were enrolled in the study. The incidence of POD was 13•2 %. Independent variables associated with POD were: age, co-morbidity, preoperative cognitive impairment, glucose abnormalities. Median length of hospital stay was 21 days for patients with POD versus 8 days for control patients (P < 0•001). The hospital mortality rate was 19 and 8•4 % respectively (P = 0•021) and mortality rate after 1 year was also higher in POD (P= 0.0001). The baseline of IL-6 concentration was higher in POD patients than patients without POD, whereas IL-2 was lower in POD patients compared to patients without POD. In a multivariate analysis only IL-6 remained associated with POD. Moreover IL-6, IL-8 and IL-2 are associated with co-morbidity, intra-hospital mortality, compromised functional status and emergency admission. No significant differences in genotype distribution were found between POD subjects and controls for any SNP analyzed in this study. Conclusion: In this study we found older age, comorbidity, cognitive impairment, glucose abnormalities and baseline of IL-6 as independent risk factors for the development of POD. IL-6 could be proposed as marker of a trait that is associated with an increased risk of delirium; i.e. raised premorbid IL-6 level predict for the development of delirium.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tanchirasi (TNKS) è un membro della superfamiglia delle PARP (Poli ADP-Ribosio Polimerasi). TNKS è coinvolta nella stabilizzazione della subunità catalitca del complesso proteico DNA-PK (protein chinasi DNA-dipendente), la DNA-PKcs. Questa proteina è fondamentale per il corretto funzionamento del meccanismo di riparo del DNA chiamato "Saldatura Non Omologa delle Estremità" (NHEJ). La deplezione di TNKS induce una degradazione della DNA-PKcs e una maggiore sensibilità alle radiazioni ionizzanti (RI). TNKS è inoltre un regolatore negativo di axina e di conseguenza un attivatore del pathway di WNT; l'inibizione quindi di TNKS induce anche una inibizione del pathway di WNT. Alterazioni in questo signalling si riscontrano frequentemente nel Medulloblastoma (MB), il tumore cerebrale embrionale più comune dell'infanzia. La radioterapia post-operatoria risulta essere molto efficacia in questa neoplasia, ma causa gravi effetti collaterali e un terzo dei pazienti presenta radioresistenza intrinseca. Un'importante sfida per la ricerca è quindi l'aumento della radiosensibilità tumorale. In questo lavoro, abbiamo studiato gli effetti dell'inibizione farmacologica di TNKS in linee cellulari di MB umano, mediante la small molecule XAV939, potente e specifico inibitore di TNKS. Il trattamento con XAV939 induce una consistente inibizione della capacità proliferativa e clonogenica, non correlata ad un aumento della mortalità cellulare, indicando una bassa tossicità legata alla molecola. Il co-trattamento di XAV939 e RI (γ-ray, dose 2 Gy) causa una ulteriore inibizione della proliferazione cellulare e della capacità di formare colonie. Abbiamo inoltre constatato, mediante Neutral Comet Assay, una minore efficacia nel riparo del DNA in cellule irradiate trattate con XAV939, indicando un effettivo aumento della radiosensibilità in cellule di MB trattate con l'inibitore di TNKS. L'aumentata mortalità cellulare in cellule tumorali trattate con XAV939 e RI ha confermato la nostra ipotesi. Il nostro studio in vitro indica come TNKS possa essere un utile target terapeutico per rendere più efficace l'attuale terapia contro il MB.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The spinal column performs important functions in the body, including the support of the entire weight of the human body, the ability to orientate the head in space, bending, flexing and rotating the body. Diseases affecting the spine are manifold: the most frequent is scoliosis, which often affects the female population. It is often treated surgically with a very high percentage of failures. The aim of the thesis is to study the role of instrumentation in mechanical failures encountered 12 months after surgery in the treatment of scoliosis. For the purposes of the study, we analyzed specific biomechanical parameters. The pelvic angles determine the position of the pelvis, while the imbalance parameters the structure of the body. We infer other parameters by analyzing the characteristics of the implanted instrumentation. Initially, the anatomy is described of the spine and vertebrae, the equipment used and the possible failures that may occur after surgery. Subsequently, the materials and methods used for the analysis of the above-mentioned parameters for the 61 patients are reported. All data are obtained by the observation of pre and post-operative x-rays with a special program, by reading reports from operators and by medical records. In the fourth chapter, we report the results: the overall failure rate is 60.9%; the types of failures that occurred are rupture of bars and rupture of bars simultaneously to PJK. The most influential parameters on results of the progress of the surgery are the type of material used and the BMI. It is estimated a high percentage of failures in patients treated with implants of cobalt chromium alloys (90.0%). According to the results obtained, it is possible to understand the aspects that in the future should be studied, in order to find a solution to the most frequent surgical failures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Genital prolapse is frequent and can be found in about 50% of parous women. Its etiology is complex and multifactorial. Predisposing factors include: genetics (connective tissue disorders, family history); general state (age, parity, weight, smoking, obstructive pulmonary disease); trauma (carrying heavy loads, intense physical exercise); or iatrogenic (post hysterectomy). Treatment can be conservative or surgical and depends mainly on the severity of symptoms. Developments in surgical techniques and synthetic material in the last 20 years enabled us to use minimally invasive procedures with improved post operative course and decreased recurrence rates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Women with vulval neoplasia often experience severe post-surgical complications. This study focuses on symptom experience of women during the first 6 months following surgical treatment for vulval neoplasia considering their socio-cultural context. In this qualitative study using a critical hermeneutic approach, narrative interviews were conducted. A purposeful sample of 20 patients was recruited from one Swiss and two German university hospitals. Content analysis was employed to analyse the transcribed interviews considering women's experiences and social perceptions. Narratives showed eight interrelated themes: delayed diagnosis, disclosed disease, disturbed self-image, changed vulva care, experienced wound-related symptoms, evoked emotions, affected interpersonal interactions and feared illness progression. The women experienced a general lack of information pertaining to above themes and all described strategies used to handle their situation, which affected their distress. The communication, assessment and treatment of symptoms were hampered by the society's and the health system's tendency to overlook these symptoms and leave them in the realm of the unspeakable. Health professionals need new strategies to support these women to recognise, assess and evaluate the seriousness of symptoms, and to communicate their symptom experience so that timely medical treatment is sought. This support may minimise potentially preventable complications and symptom-related distress.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to describe the sciatic-femoral nerve block (SFNB) in goats and to evaluate the peri-operative analgesia when the goats underwent stifle arthrotomy. The animals were randomly assigned to one of four treatment groups: groups 0.25, 0.5 and 0.75 received 0.25%, 0.5% and 0.75% of bupivacaine, respectively, while group C (control group) received 0.9% NaCl. In all groups, the volume administered was 0.2 mL/kg. Intra-operatively, the proportion of animals receiving rescue propofol was significantly lower in groups 0.5 and 0.75, compared to group C. Post-operatively, the visual analogue scale (VAS) and total pain score were significantly higher in group C than in the other groups. Group 0.75 had the highest percentage of animals showing motor blockade. SFNB performed with bupivacaine resulted in better intra- and post-operative analgesia than SFNB performed with saline. Compared to the other concentrations, 0.5% bupivacaine resulted in satisfactory analgesia with acceptable side effects.